• Title/Summary/Keyword: partial contact defect

Search Result 14, Processing Time 0.02 seconds

A STUDY ON SHEAR BOND STRENGTH OF INTERFACE BETWEEN BONE AND TITANIUM PLASMA SPRAYED IMZ IMPLANT IN RABBITS (가토에 이식된 Titanium plasma Sprayed IMZ 임프란트와 골의 계면 접촉 양상에 따른 결합력에 관한 연구)

  • Han, Chong-Hyun;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.225-243
    • /
    • 1991
  • In recent years immediate implantation has been tried by a few clinicians. This study placed IMZ implants in the rabbit femur with and without bony defects around the implant for simulating fresh extraction site. And one group with bony defects used porous hydroxyapatite ganules(HA) to fill if and the other group left the bony defects around the implant. The purpose of this study was to compare the shear bond strength and the bony contact and formation around the implant. Fifteen rabbits were divided into three groups and placed 10 IMZ implants to each group. Implant sites were surgically prepared with IMZ drills kit and implants were placed(Control), artificial bony defect was created with Apaceram drills kit around the implant sites and implants were placed(Experimental I), bony defect was filled with porous hydroxyapatite granules(Experimental II). Thereafter, rabbits were sacrificed at 8th week and specimens were prepared and pushout tested for shear bond strength of bone-implant interface immediately. Undecalcified and decalcified specimens were prepared with Vilanueva and hematoxylin-eosin stain for light microscopic finding. The results of this study were as follows. 1. In the control group, mean shear strength of bone-implant interface was $2.614{\pm}0.680$ MPa, experimental I was $0.664{\pm}0.322$ MPa, and experimental II was $2.281{\pm}0.606$ MPa. There was significant difference between control and experimental I, between experimental I and experimental II, but did not show significant difference between control and experimental II statistically. 2. In the bony formation surrounding IMZ implant of the three groups, that of cortical bone is more advanced than cancellous bone area. 3. In the histological findings of undecalcified specimens, control and experimental II showed more than 50% of bony or osteoid formation at the bony-implant interface. 4. In the histological findings of undecalcified specimens, experimental I showed less than 50% of bony or osteoid formation at the interface, and observed partial bony defect in the coronal zone. 5. In the experimental II group, were observed direct bony contact to hydroxyapatite granules, and infiltration of a few giant cells. 6. No inflammatory responses were seen around the titanium implants and the hydroxyapatite granules.

  • PDF

Arterialized Venous Free Flap at the Insufficient Vascular Recipient Bed in Finger Reconstruction (수지 재건시 불충분한 혈행상태의 수혜부에 시행한 동맥화 정맥 유리 피판술)

  • Lee, Young-Keun;Park, Ki-Tae;Lee, Jun-Mo;Park, Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.2
    • /
    • pp.131-136
    • /
    • 2012
  • Purpose: Arterialized venous flap is useful for reconstruction of the traumatic soft tissue defect in fingers, but insufficient circulation of the traumatic fingers makes surgeons annoying to use the flap. We have grafted flaps in 7 fingers with insufficient vascular bed hoping to expanded the category of the flap. Materials and Methods: Arterialized venous flap have transplanted in 7 fingers from March 2008 through February 2010 and followed up for 4 to 16 months(average 7.2 months). They were all male with a mean age at the time of surgery was 33. The main injury was crushing in 4 degloving, contact burn and saw injury was I respectively. Time interval from injury to flap transplantation was average 3.1. weeks(3 days to 6 weeks). Designed flap size ranges from $8cm{\times}3.5cm$to $4cm{\times}3cm$. Vessel type of flap was one artery with two veins were 5 cases and one artey with one vein 2. Flap type was cutaneous in 3, tendocutaneous 2, neurotendocutaneous 1 and neurocutaneous 1. The circulation state of recipient site was avascular in 2 cases, insufficiency 3 and tip avascular 2. Results: Arterialized venous flap was complete survived in 2 cases, partial necrosis(less than 10%) 3 and failed in 2. Conclusion: An arterialized venous free flap could be a useful procedure for reconstruction in soft tissue or combined defect of the finger despite an avascular or insufficient vascular beds if the recipient beds were free from infection.

  • PDF

Development of a process to apply uniform pressure to bond CFRP patches to the inner surface of undercut-shaped sheet metal parts (언더컷 형상의 판재 성형품에 보강용 CFRP 패치의 접합을 위한 공정기술 개발)

  • Lee, Hwan-Ju;Jeon, Yong-Jun;Cho, Hoon;Kim, Dong-Earn
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.65-70
    • /
    • 2020
  • Partial reinforcement of sheet metal parts with CFRP patch is a technology that can realize ultra-lightweight body parts while overcoming the high material cost of carbon fiber. Performing these patchworks with highly productive press equipment solves another issue of CFRP: high process costs. The A-pillar is the main body part and has an undercut shape for fastening with other parts such as roof panels and doors. Therefore, it is difficult to bond CFRP patches to the A-pillar with a general press forming tool. In this paper, a flexible system that applies uniform pressure to complex shapes using ceramic particles and silicone rubber is proposed. By benchmarking various A-pillars, a reference model with an undercut shape was designed, and the system was configured to realize a uniform pressure distribution in the model. The ceramic spherical particles failed to realize the uniform distribution of high pressure due to their high hardness and point contact characteristics, which caused damage to the CFRP patch. Compression equipment made of silicone rubber was able to achieve the required pressure level for curing the epoxy. Non-adhesion defects between the metal and the CFRP patch were confirmed in the area where the bending deformation occurred. This defect could be eliminated by optimizing the process conditions suitable for the newly developed flexible system.

Reconstruction of the Bone Exposed Soft Tissue Defects in Lower Extremities using Artificial dermis(AlloDerm®) (인공 진피(알로덤®)을 이용한 하지의 골이 노출된 연부 조직 결손의 재건)

  • Jeon, Man Kyung;Jang, Young Chul;Koh, Jang Hyu;Seo, Dong Kook;Lee, Jong Wook;Choi, Jai Koo
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.578-582
    • /
    • 2009
  • Purpose: In extensive deep burn of the lower limb, due to less amount of soft tissue, bone is easily exposed. When it happens, natural healing or reconstruction with skin graft only is not easy. Local flap is difficult to success, because adjacent skins are burnt or skin grafted tissues. Muscle flap or free flap are also limited and has high failure rate due to deep tissue damage. The authors acquired good outcome by performing one - stage operation on bone exposed soft tissue defect with AlloDerm$^{(R)}$(LifeCell, USA), an acellular dermal matrix producted from cadaveric skin. Methods: We studied 14 bone exposed soft tissue defect patients from March 2002 to March 2009. Average age, sex, cause of burn, location of wound, duration of admission period, and postoperative complications were studied. We removed bony cortex with burring, until conforming pinpoint bone bleeding. Then rehydrated AlloDerm$^{(R)}$(25 / 1000 inches, meshed type) was applicated on wound, and thin split thickness(6 ~ 8 / 1000 inches) skin graft was done at the immediately same operative time. Results: Average age of patients was 53.6 years(25 years ~ 80 years, SD = 16.8), and 13 patients were male(male : female = 13 : 1). Flame burn was the largest number. (Flame burn 6, electric burn 3, contact burn 4, and scalding burn 1). Tibia(8) was the most affected site. (tibia 8, toe 4, malleolus 1, and metatarsal bone 1). Thin STSC with AlloDerm$^{(R)}$ took without additional surgery in 12 of 14 patients. Partial graft loss was shown on four cases. Two cases were small in size under $1{\times}1cm$, easily healed with simple dressing, and other two cases needed additional surgery. But in case of additional surgery, granulation tissue has easily formed, and simple patch graft on AlloDerm$^{(R)}$ was enough. Average duration of admission period of patients without additional surgery was 15 days(13 ~ 19 days). Conclusion: AlloDerm$^{(R)}$ and thin split thickness skin graft give us an advantage in short surgery time and less limitations in donor site than flap surgery. Postoperative scar is less than in conventional skin graft because of more firm restoration of dermal structure with AlloDerm$^{(R)}$. We propose that AlloDerm$^{(R)}$ and thin split thickness skin graft could be a solution to bone exposured soft tissue defects in extensive deep burned patients on lower extremities, especially when adjacent tissue cannot be used for flap due to extensive burn.