FSIG 풍력발전의 특성개선을 위한 DFIG의 협조 전압제어 (Coordinated Voltage Control of DFIG to Overcome Shortcomings of FSIG in Wind Turbine System)

  • 드옹 민콴;노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.704-705
    • /
    • 2011
  • At present, the widely used wind power generators in the whole world are fixed speed induction generator (FSIG) and doubly fed induction generator (DFIG). The models of FSIG and DFIG wind power generation system connected with the grid are built, and their steady-state and transient characteristics are studied. A new coordinated control strategy using both the grid and rotor side converters of DFIG for voltage regultation and reactive power support is put forword to improve the steady-state and transient performance of the FSIG in the case of DFIG in parallel with FSIG.

  • PDF

Optimal Design of a DC-DC Converter for Photovoltaic Generation

  • Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제25권3호
    • /
    • pp.40-49
    • /
    • 2011
  • This paper presents novel circuit topology of half-bridge soft-switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed, half-bridge high frequency PWM inverter with a high frequency planar transformer link PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode-equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC bus lines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, high switching frequency IGBTs can actually be selected in the frequency range of 40[kHz] under the principle of soft-switching. The performance evaluations of the experimental setup are illustrated practically.

SIMULTANEOUS SPEED AND ROTOR TIME CONSTANT IDENTIFICATION OF AN INDUCTION MOTOR DRIVE BASED ON THE MODEL REFERENCE ADAPTIVE SYSTEM COMBINED WITH A FUZZY RESISTANCE ESTIMATOR

  • Soltani, Jafar;Mizaeian, Behzad
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.11-16
    • /
    • 1998
  • In this paper, simultaneous estimation of rotor speed and time constant for a voltage source inverter (VSI) fed induction motor drive are disccussed. The theory is based on the Model Reference Adaptive System (MRAS). The identifier executes Simultaneous rotor speed and time constant so that vector control of the induction may be achieved in the rotor-flux oriented reference frame. Furthermore, to eliminate the offset error caused by the change in the stator resistance, a fuzzy resistance regulator is also designed which operates in parallel with the rotor speed and time constant identifier

  • PDF

지하철 누설전류가 도시가스 배관에 미치는 영향 해석 (Analysis of DC Traction Stray Current Interference on Buried Pipelines)

  • 이현구;하태현;하윤철;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1376-1378
    • /
    • 2004
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the cathodic protection systems of buried pipelines and DC traction stray current influence on it using the simulation software CatPro. We can discuss the problems and mitigation of DC traction interference for protected pipeline.

  • PDF

능동클램프회로를 갖는 병렬공전 인버터 링크형 DC-DC 컨버터 (A Parallel Resonant inverter linked type DC-DC Converter with active-c1amp circuits)

  • 오경섭;남승식;김동희;김희대;선우영호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.311-314
    • /
    • 2003
  • In this paper, proposed circuit proposes that Active-Clamp-Circuits basis of a current-fed inverter linked type high frequency resonant dc-dc converter of conventional. and the paper the most of characteristics of the reduced high voltage stress main switches with active clamp circuits and output current constant with the resonant part consists of L, C resonant tank circuit. Also, the capacitor (C$_1$, C$_2$) connected in switches are a common using by resonance capacitor and ZVS capacitor. and circuit analysis used state equation of each part modes. Also we conform a rightfulness theoretical analysis by comparing a parameters values and simulation values obtained from simulation using Power MOS-FET as switching devices.

  • PDF

전철 간섭 대책용 분포형 외부전원시스템의 배관인출 방법에 따른 영향 (Influence on Lead Wire Method of Distributed ICCP Systems for Mitigation of DC Traction Interference)

  • 이현구;하윤철;하태현;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.282-284
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the influence on lead wire method of distributed ICCP(impressed current cathodic protection) systems for mitigation of DC traction interference using the simulation software CatPro.

  • PDF

전철 간섭 대책용 분포형 외부전원시스템의 양극위치 (Anode Location of Distributed ICCP Systems for Mitigation of DC Traction Interference on Buried Pipelines)

  • 이현구;하태현;하윤철;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1660-1662
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the anode location of distributed impressed current cathodic protection systems for the mitigation of DC traction interference on buried pipelines using the simulation software CatPro. We can get a fix on the anode location.

  • PDF

전류원 PWM 컨버터 / 인버터를 이용한 새로운 단조용 유도가열 전원장치의 설계 (Design of New Induction Heating Power Supply for Forging Applications Using Current-Source PWM Converter and Inverter)

  • 최승수;이창우;김인동
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1602-1610
    • /
    • 2018
  • Induction heating can convert electrical energy to thermal energy with high conversion efficiency and quick heating. Currently, a current source rectifier/inverter-fed parallel resonant circuit is widely used as an induction heating power supply for forging applications. However, the conventional induction heating power supplies composed of phase-controlled rectifier and SCR inverter have low efficiency and low power factor at input side, and require additional starting circuitry. So this paper proposes new induction heating power supply topologies for forging applications which have high power factor, high efficiency, and large output power. It also suggests detailed design guideline.

배수관망에서 수처리에 의한 AOC, BDOC및 세균성장의 특성 (Characterizations of Assimilable Organic Carbon, Biodegradable Dissolved Organic Carbon, and Bacterial Regrowth in Distribution Systems by Water Treatment)

  • Chang, Young-Cheol;Kweon Jung;Yoo, Young-Sik;Kang, Mi-Hye;Andrew A. Randall
    • 한국환경보건학회지
    • /
    • 제28권5호
    • /
    • pp.42-52
    • /
    • 2002
  • 배수관망에서의 박테리아 재 증식은 큰 현안문제로 대두되고 있으며 이를 억제하기 위한 염소소독 또한 발암성의 부산물인 THMs(trihalomethanes)등을 생성시킬 우려 때문에 미국에서는 오존살균처리 또는 나노여과 (nanofiltration) 법으로 대체해 오고 있다. 그러나 종래의 많은 bench scale 실험결과를 통해 이러한 처리 이후에 잔존하는 미량의 유기물(assimilable organic carbon)이 박테리아 재 증식에 계속하여 영향을 주고 있다는 결과가 AOC(assimilable organic carbon)와 박테리아 재증식의 상관관계를 통하여 밝혀지고 있다. 그러나 현재까지 이러한 연구결과를 full-scale규모의 현장시설에서 직접 검토한 예는 없다. 따라서 본 실험은 미국플로리다주에 위치한 두 지역의 full-scale배수관망 시설을 선정하여 실시하였다. 첫 번째 시설은 오존 살균처리를 그리고 다른 한곳은 나노여과와 석회 연수법 (lime softening)을 병행한 처리법을 사용하고 있다. 박테리아 증식은 R2A 배지를 사용하는 HPC(heterotrophic plate counts)법으로 평가했으며 오존이 공급된 배수관망에서의 HPC 는 각 셈플링 지점의 AOC값을 이용한 지수모델과 높은 상관관계가 있음이 판명되었다($R^2$=0.97). 또한 오존처리는 100%이상의 AOC 농도증가를 나타냈다. 나노여과법과 석회연수법을 병행하고 있는 시설에서도 AOC에 근거한 지수모델과 상관관계를 나타냈다($R^2$=0.75). 그러나 BDOC(biodegradable dissolved organic carbon)는 박테리아 증식에 있어 매우 낮은 상관관계 값을 표시했다($R^2$=0.11). 결과적으로 종래의 많은 bench scale실험결과와 같이 AOC는 배수관망에서의 박테리아 증식과 크게 상관관계를 갖고 있는 것으로 밝혀졌다.

자외선 조사와 병행된 녹차추출물 식이공급이 무모생쥐의 표피보습 개선 및 유리아미노산 생성 관련 대사에 미치는 영향 (Dietary effect of green tea extract on hydration improvement and metabolism of free amino acid generation in epidermis of UV-irradiated hairless mice)

  • 최수민;신지혜;이보민;조윤희
    • Journal of Nutrition and Health
    • /
    • 제49권5호
    • /
    • pp.269-276
    • /
    • 2016
  • 본 연구에서는 자외선 조사를 병행하여 녹차 추출물의 식이공급을 10주간 공급한 무모생쥐 (UV+1%GTE군)의 표피 보습과 filaggrin 의 대사물질 및 관련 효소인 PAD3의 발현 및 함량 변화를 정상대조군 (UV-군) 및 자외선 조사군 (UV+군)과 비교 분석하였으며 결과는 다음과 같다. UV+군의 피부 보습은 UV-군보다 유의적으로 낮은 반면 UV+1%GTE군 의 피부 보습은 UV+군에 비해 유의적으로 높았고, UV-군에는 미치지 못하였다. UV+군의 profilaggrin 함량은 UV-군과 유의적인 차이가 없었으나, filaggrin의 함량은 UV-군에 비해 유의적으로 낮았다. UV+1%GTE군 에서 profilaggrin은 UV- 및 UV+에비해 현저히 높았고, filaggrin은 UV-군과 유사한 수준으로 높았다. UV+군의 PAD3 효소 발현은 UV-군에 비해 유의적으로 낮았다. UV+1%GTE군은 UV+군에 비해 유의적으로 높았으며, UV-군에 비해 높았다. 자연보습인자의 주요 아미노산인 serine 및 glycine, alanine의 함량은 UV-군과 UV+군간 유사하였으나 UV+1%GTE군에서는 UV- 및 UV+군에 비해 현저히 높았다. UV-군과 비교하여 UV+군의 피부 보습함량이 낮게 측정된 것에 비해 유리아미노산 함량에는 변화가 없어 자외선에 따른 피부 보습에 관여되는 또 다른 메커니즘인 표피 지질함량 분석과 함께 녹차추출물의 효과에 대한 연구가 추후 이루어질 필요성이 있다. 그러나, 결론적으로 자외선 조사와 병행된 녹차 추출물 식이 공급은 (pro)filaggrin의 함량 및 PAD3의 발현이 높게 나타남에 의한 표피 유리아미노산의 함량이 높아 궁극적으로 자외선 조사에 의해 야기된 피부건조를 완화시켰다.