• 제목/요약/키워드: parallel-fed

검색결과 115건 처리시간 0.029초

3상 고역률 Flyback 컨버터를 이용한 전압형 인버터의 고조파 제거 (Elimination of Harmonics Voltage-fed Inverter using Flyback Converter with Three-Phase High Power Factor)

  • 서기영;권순걸;이현우;고태언;김영문;문상필;장우신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2695-2697
    • /
    • 1999
  • A new three-phase voltage-fed inverter using partial resonant converter with high power factor and high efficiency is proposed. The proposed Flyback converter is constructed by using a resonant network in parallel with the switch of the conventional converter. The devices are switched zero voltage or zero current eliminating the switching loss. This paper introduces elimination of harmonics compared with conventional SPWM inverter and three-phase voltage-fed inverter using Flyback converter.

  • PDF

플랜지된 평행평판도파관으로 급전된 슬릿의 등가 어드미턴스 및 좁은 슬릿을 통한 최대결합 메커니즘 (Equivalent Admittance of a Slit Fed by a Flanged Parallel-Plate Waveguide and Maximum Coupling Mechanism through a Narrow Slit)

  • 이종익;김강욱;조영기
    • 한국전자파학회논문지
    • /
    • 제15권11호
    • /
    • pp.1116-1122
    • /
    • 2004
  • 플랜지된 평행 평판 도파관의 슬릿을 통한 전자기적인 결합문제를 고려하였다. 결합 슬릿 근처 도파관 내 $.$외부의 무효전력을 반영한 슬릿의 등가 어드미턴스를 구하고, 슬릿의 폭이 매우 좁은 경우에서의 최대결합 메커니즘을 규명하였다. 도파관의 높이, 슬릿의 폭 및 슬릿의 변위 등과 같은 구조적인 파라미터들이 복사 특성에 미치는 영향을 관찰하였다.

주파수 추종과 정전력 제어가 가능한 고주파 유도가열기의 병렬 공진형 인버터에 대한 연구 (Study on the Parallel Resonant Inverter of an High Frequency Induction Heating System which the Frequency Tracking and the Power Regulation is possible)

  • 김남수;김태언;김승철;임영도
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.63-66
    • /
    • 2002
  • This paper has been studied the parallel resonant inverter which controlling the constant power and tracking the load resonant frequency with PLL is possible, in order to minimize switching losses. The current-fed full-bridge type parallel resonant inverter of an induction heating system was composed of IGBT in switching device. For regulating the output power of an induction heating system, the Fuzzy controller is used. The Fuzzy controller makes the control signal for a stable power regulating control and when reference is changed, it is superior to adaptability. It has been evaluated a stable behavior for a noise with switching and a load disturbance.

  • PDF

Fault Diagnosis of a Voltage-Fed PWM Inverter for a Three-parallel Power Conversion System in a Wind Turbine

  • Ko, Young-Jong;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.686-693
    • /
    • 2010
  • In this paper, a fault diagnosis method based on fuzzy logic for the three-parallel power converter in a wind turbine system is presented. The method can not only detect both open and short faults but can also identify faulty switching devices without additional voltage sensors or an analysis modeling of the system. The location of a faulty switch can be indicated by six-patterns of a stator current vector and the fault switching device detection is achieved by analyzing the current vector. A fault tolerant algorithm is also presented to maintain proper performance under faulty conditions. The reliability of the proposed fault detection technique has been proven by simulations and experiments with a 10kW simulator.

전철 간섭 대책용 분포형 외부전원시스템이 병행하는 배관에 미치는 영향 (Influence on Parallel Pipelines of Distributed ICCP Systems for Mitigation of DC Traction Interference)

  • 이현구;하윤철;하태현;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.285-287
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the influence on parallel pipelines of distributed ICCP(impressed current cathodic protection) systems for mitigation of DC traction interference using the simulation software CatPro.

  • PDF

생물학적 질소·인제거 공정에서 일차 침전지의 영향 (The Role of Primary Clarifier in Biological Processes for Nutrient Removal)

  • 황규대;김태경
    • 한국물환경학회지
    • /
    • 제23권1호
    • /
    • pp.19-26
    • /
    • 2007
  • The lab-scale BNR processes fed with Municipal Wastewater Before or After Primary Clarifier (MWBPC or MWAPC) were operated to observe the behavior of particle organic matter in terms of nitrification and denitrification efficiency. As a result of the fractionation of the COD from MWBPC or MWAPC using an aerobic respirometric serum bottle reactor, the total mass of biodegradable organic matter from MWBPC is about 52% greater than the mass from MWAPC. Batch reactors were operated to observe the effect of the Particulate Organic Matter (POM) on substrate utilization for denitrification. Although the consumption of POM for denitrification was observed, the increment of the Specific Denitrification Rate (SDNR) was not great. In terms of the effect of POM on nitrification at different HRTs, activate sludge reactors were operated to determine the optimal HRT when MWBPC and MWAPC were fed relatively. All reactors showed a great organic matter removal efficiency. Reactors fed with MWAPC had obtained the nitrification efficiency above 90% when the HRT of 4 hr, at least, was maintained, while reactors fed with MWBPC had same efficiency when the HRT longer than 5 hr was kept. Three parallel $A^2/O$ systems fed with MWBPC or MWAPC relatively were operated to investigate the effects of POM on BNR processes with varying the HRT of an anoxic reactor. For all systems, the efficiency of organic matter removal and denitrification, respectively, was great and about the same. In case of denitrification efficiency, system with MWAPC had 1.5% lower than system with MWBPC at the same HRT of anoxic reactor of 2 hr, and the increasing the HRT of the anoxic reactor by 1 hr in systems fed with MWBPC resulted in a 3.5% increment. The denitrification rate was similar while the consumption of organic matter in systems fed with MWBPC was higher than system fed with MWBPC. It suggests that POM in MWBPC was not be used significantly as a substrate for denitrification in system with the HRT of 3 hr of an anoxic reactor.

단일 인버터 기반 에어컨용 실외기 팬 모터 병렬운전에서의 무효전력보상기를 이용한 맥동저감 기법 (The Vibration Suppression using Reactive Power Compensator for Speed Control of Parallel Connected Dual Fan Motors fed by a Single Inverter)

  • 윤철;권우현;조내수
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2008-2013
    • /
    • 2016
  • This paper proposes analysis and suppression method for reactive power vibration of the slave motor caused by back-EMF mismatch between the master and the slave motor and stator resistance during middle-low speed operation. The master and slave motors are parallel connected dual SPMSMs(Surface mounted Permanent Magnet Synchronous Motors) fed by a single inverter. To suppress vibration of reactive power, RPC(Reactive Power Compensator) proposed in this paper analyzes flux-axis current vibration of the slave motor that occurs in middle-low speed operation using a mathematical model of the fan motor. And RPC adds vibration components detected from flux-axis current of the slave motor to flux-axis current of the master motor. The results of experiment conducted verify the efficacy of the proposed method.

Wax-Sealing용 전류형 고주파 공진 인버터의 특성해석에 관한 연구 (A Study on Characteristic Analysis of Current Fed High Frequency Resonant Inverter for Wax-Sealing)

  • 김동희;원재선
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권11호
    • /
    • pp.568-574
    • /
    • 2001
  • This paper describes a current fed high frequency resonant inverter can be used as the power supply for wax-sealing. This circuit configuration is composed of conventional two unit inverter of single ended current find type in parallel. The proposed inverter can realize ZVS operation by using resonant capacitor to ZVS capacitor and has merits not only reduction of switch current distribution but also extension of load range in comparison with the conventional single-ended current fed high frequency resonant inverter. This analysis of proposed circuit uses normalized parameter and characteristic estimation which is needed in each step before design is generally described according to normalized frequency($\mu$), normalized resistance(λ) and parameters. On the basis of characteristic values, a method of the circuit design is presented. Also, the theoretical analysis is proved through experiment and this proposed circuit shows that it can be practically used as the power supply system for wax-sealing and DC-DC converter.

  • PDF

용존산소 제한 또는 탄소원 제한 조건의 유가식배양에서의 Cyclosporin A 생합성 연구 (Studies of Cyclosporin A Biosynthesis under the Conditions of Limited Dissolved Oxygen or Carbon Source in Fed-batch Culture)

  • 전계택;박성관;권호균;정연호;정용섭;장용근;이영행
    • KSBB Journal
    • /
    • 제13권2호
    • /
    • pp.203-208
    • /
    • 1998
  • We investigated the effects of dissolved oxygen (D.O.) and fructose (C-source) on cell growth and biosynthesis of cyclosporin A (CyA) produced as a secondary metabolite by a wild-type filamentous fungus, Tolypocladium inflatum. This was performed by controlling the level of D.O. and the residual C-source, as required, through adjustment of medium flow rate, medium concentration and agitation rate in fed-batch cultures. CyA production was furned out to be maximal, when D.O. level was controlled around 10% saturated D.O. and concentration of the C-source was maintained sufficiently low (below 2 g/L) not to cause carbon catabolite repression. Under this culture condition, we obtained the highest values of CyA concentration (507.14 mg/L), Qp (2.11 mg CyA/L/hr), $Y_x/s$ (0.49 g DCW/g fructose), $Y_p/s$<(22.56 mg CyA/g fructose), and YTEX>$_p/x$ (48.31 mg CyA/g DCW), but relatively lower values of cell concentration (11.98 g DCW/L) and cell productivity (0.043 g DCW/L/hr), in comparison with other parallel fed-batch fermentation conditions. These results implied that, in the carbon-limited culture with 10% saturated D.O. level, the producer microorganism utilized the C-source more efficiently for secondary metabolism.

  • PDF

변조레벨 제어 다중반송파 CDMA 시스템 (Modulation Level-Controlled Multicarrier CDMA System)

  • 황봉준;박형근
    • 한국정보통신학회논문지
    • /
    • 제12권9호
    • /
    • pp.1646-1653
    • /
    • 2008
  • 본 논문에서는 전송 채널의 주파수 선택적 특성에 의한 전송 신호의 왜곡현상을 줄이며, 다양한 무선 전송 환경에 대해 일정한 전송 품질을 유지시키는 동시에 최대 데이터 전송률을 제공할 수 있는 다중 반송파 CDMA을 제안한다. 이 시스템은 채널 상태에 따라 작은 지연과 페이딩을 겪는 채널에서는 높은 데이터 전송률로 전송하고, 반면 빠른 페이딩과 긴 지연 성분을 갖는 채널에서는 낮은 전송률로 데이터를 전송한다. 두 경우 모두 다 송신기 구조에서 데이터 직병렬 변환 개수와 데이터 복사 개수를 조절함으로써 가능하다. 여기서, 제안한 시스템은 고정된 수의 부반송파를 갖는다. 따라서 위에서 언급한 직병렬 변화 개수와 데이터 복사 개수의 곱은 항상 일정하게 유지되므로 하드웨어의 변형 없이 구현될 수 있다. 제안한 시스템에서는 직병렬 변환 후 동일 데이터가 여러 다른 부반송파에 복사되어 전송되므로 주파수 다이버시티 이득을 얻을 수 있으며, 레이크(RAKE) 수신구조는 경로 다이버시티 이득도 얻을 수 있게 한다.