• Title/Summary/Keyword: parallel-connected battery

Search Result 59, Processing Time 0.026 seconds

Development of Activation Battery for Space Launch Vehicle (우주발사체 탑재용 기동배터리 개발)

  • Kim, Myung-Hwan;Ma, Keun-Su;Lim, You-Chol;Lee, Jae-Deuk
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1949-1950
    • /
    • 2008
  • Activation battery that are required to deliver short pulses to power, for instance, pyrotechnic devices required during jettison payload separation. Activation battery contains 24 Sony US18650 cells configured as 3 strings in parallel, with each string containing 8 series connected cells. This allows to meet voltage and capacity requirements specified for the mission. In this paper design description and specifications of Activation battery are presented. Qualification test flow and results are also shown to make sure the performance in the predicted space environment. Electrical performance was proven on real equipment load assembly.

  • PDF

Applications of Current Limiting Diode to Chip on Board Type Light Source and Lighting Equipment Circuits (정전류다이오드를 이용한 COB 타입 LED 광원 및 조명기기 회로)

  • Park, Hwa Jin;Yu, S.J.;Park, Jong Min;Kim, Y.J.
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.488-492
    • /
    • 2013
  • Current limiting diode (CLD) was fabricated using junction field effect transistor (JFET) structured two small cells and eight large cells. Two small cells and eight large cells were connected in parallel and the obtained constant current was 110 mA. The application of CLD in each of the parallel circuits on chip on board (COB) type LED lighting source, could significantly reduce the current deviation within the parallel circuits. The applications of CLD on AC power small lighting source, battery power low voltage parallel lighting source and AC flat lighting source were investigated.

Variable Output and Parallel Operation Control of EV Charger (전기자동차용 충전기의 가변출력 및 병렬운전 제어)

  • Lee, Sang-Hyeok;Kang, Seong-Gu;Awasthi, Prakash;Hwang, Jung-Goo;Lee, Seung-Yul;Wi, Han-Byul;Park, Sung-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.153-160
    • /
    • 2013
  • This research paper describes the development of battery charger with a variable output voltage capacity for charging the batteries used in electrical vehicles. The voltage and current accordingly is control via the buck converter that receives three phase current at primary side and fed to bridge rectifier which is comprised of full bridge converter and HFTR(High Frequency Transformer) for isolation and a square wave AC output. The transformer primary side is in series to divide certain charging current and the secondary side is comprised of six fix transformers so that they can generate certain amount of power and various output voltage through relay connection using 6 DC outputs. Moreover, all parallel connected full bridge serial resonant converter communicate together with upper(main) controller. The constructed structure is verified by conducting the test on PSIM as well as experimentally.

The Development and Experimental Evaluation of 100kVA Unified Power Quality Conditioner interconnected to the Li-Battery System (리튬 배터리를 연계한 100kVA UPQC 개발 및 성능시험)

  • Lee, Hak-Ju;Chae, Woo-Kyu;Park, Jung-Sung;Sohn, Jin-Man;Choi, Eun-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.102-110
    • /
    • 2012
  • This paper propose the advanced topology of UPQC, its DC link is connected with Lithium battery, to compensate the momentary interruptions. The proposed system can be operated as UPS mode using the parallel inverter, which control the charge or discharge of battery, in case of the interruption. We dvelop 100kVA UPQC using the proposed topology to rise the power quality and the reliability of Microgrid. We verify its usefulness through voltage compensation test, UPS operation test and etc. using Microgrid test facility.

Development of the TVC Battery for High Voltage Loads in KSLV-I Upper Stage (KSLV-I 상단부 고전압 부하용 TVC 배터리 개발)

  • Kim, Myung-Hwan;Ma, Keun-Sum;Lim, You-Chol;Lee, Jae-Deuk
    • Aerospace Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.110-116
    • /
    • 2008
  • This paper gives a brief summary of the TVC battery design description, specifications and test results. The TVC battery for KSLV-I upper stage contains 168 Sony l8650VT high power lithium-ion cells. It configured as 2 strings in parallel, with each string containing 84 series connected cells. This allows to meet nominal 270V voltage and capacity requirements specified for the mission of the Thrust Vector Control(TVC) system. The loads profile of the TVC system has short duration, high current pulse. To power such a system with minimal mass, the battery employed l8650VT Cells. This cell is specifically designed for high rate applications and is capable of a 10C continuous discharge.

  • PDF

Seamless Transfer Method of BESS Connected by Engine Generator (엔진발전기와 연계된 BESS의 무순단 모드 전환 기법)

  • Shin, Eun-Suk;Kim, Hyun-Jun;Kim, Kyo-Min;Yu, Seung-Yeong;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1709-1717
    • /
    • 2015
  • In remote islands PV (Photo Voltaic) panel with BESS (Battery Energy Storage System) supplies electric power to the customers in parallel operation with EG (Engine Generator) to save fuel consumption and to mitigate environmental load. BESS operates in voltage control mode when it supplies power to the load alone, while it operates in current control mode when it supplies power to the load in parallel with EG. This paper proposes a smooth mode change scheme from current control to voltage control of BESS by adding proper initial value to the integral part of voltage control, and a smooth mode change scheme from voltage control to current control by tracking the EG output voltage to the BESS output voltage using PLL (Phase-Locked Loop). The feasibility of proposed schemes was verified through computer simulations with PSCAD/EMTDC, and the feasibility of actual hardware system was verified by experiments with scaled prototype. It was confirmed that the proposed schemes offer a seamless operation in the stand-alone power system in remote islands.

High Power Density and Low Cost Photovoltaic Power Conditioning System with Energy Storage System (에너지 저장장치를 갖는 고 전력밀도 및 저가격형 태양광 인버터 시스템)

  • Keum, Moon-Hwan;Jang, Du-Hee;Hong, Sung-Soo;Han, Sang-Kyoo;SaKong, Suk-Chin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.587-593
    • /
    • 2011
  • A new high power density and low cost Photovoltaic Power Conditioning System (PV PCS) with energy storage system is proposed. Its high power density and cost effectiveness can be achieved through the unification of the maximum power point tracker and battery charger/discharger. Despite of the reduced power stage, the proposed system can achieve the same performances of maximum power point tracking and battery charging/discharging as the conventional system. Moreover, the high voltage stress across the link-capacitor can be relieved through the series-connected link-capacitor with the battery. Therefore, a large number of series/parallel-connected link-capacitors can be reduced by 4-times. Especially, when the utility power failure happens, both photovoltaic and battery energies can be supplied to the load with only one power stage. Therefore, it features a simpler structure, less mass, lower cost, and fewer devices. Finally, to confirm the operation, validity, and features of the proposed system, theoretical analysis and experimental results from a single phase AC 220Vrms/1.5kW prototype are presented.

Reconstruction of Current Waveform for Traction Control of Battery Car using Parallel-connected MOSFET's On-Voltage (배터리차 추진제어를 위한 병렬 MOSFET의 도통전압을 이용한 전류파형 검출)

  • 장성동;김성중;정재호;신휘범
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.197-200
    • /
    • 1999
  • In this paper, an algorithm of reconstructing the armature current of the battery car is presented by using MOSFET's on-voltage of the dc chopper and a corresponding circuit is developed with the low-cost analog multiplexer. For driving comfort, the armature current of the motor or the traction force should be properly controlled when the car changes the direction and is accelerated or decelerated and climbs up or down the hill. Therefore, an information of the current is needed for the traction control. The proposed reconstruction algorithm is experimentally verified.

  • PDF

Selection of Coupling Factor for Minimum Inductor Current Ripple in Multi-winding Coupled Inductor Used in Bidirectional DC-DC Converters

  • Kang, Taewon;Suh, Yongsug
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.879-891
    • /
    • 2018
  • A bidirectional dc-dc converter is used in battery energy storage systems owing to the growing requirements of a charging and discharging mode of battery. The magnetic coupling of output or input inductors in parallel-connected multi modules of a bidirectional dc-dc converter is often utilized to reduce the peak-to-peak ripple size of the inductor current. This study proposes a novel design guideline to achieve minimal ripple size of the inductor current under bidirectional power flow. The newly proposed design guideline of optimized coupling factor is applicable to the buck and boost operation modes of a bidirectional dc-dc converter. Therefore, the coupling factor value of the coupled inductor does not have to be optimized separately for buck and boost operation modes. This new observation is explained using the theoretical model of coupled inductor and confirmed through simulation and experimental test.

A study on scalable battery architectures for hot-swap facilitation (핫 스왑 촉진을 위한 확장 가능한 배터리 아키텍처에 관한 연구)

  • Abbas, Mazhar;Cho, Inho;Kim, Jonghoon
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.212-213
    • /
    • 2019
  • High power and energy applications of battery require a large number of batteries to be connected in series, parallel or mixed configurations. The reliability or these batteries is improved by making them tolerant to faults i.e. by bypassing the fault cells and adding new cells to compensate the voltage and current requirement. The addition or removal or cells may cause the current stress on other healthy cells. The estimation and control or this current stress is one or the technique proposed by other researchers. This study intends to identify a suitable scalable configuration which can either avoid or reduce the efforts on the estimation and control of stress current. In addition, this paper will explore the issues associated with hot-swap.

  • PDF