• 제목/요약/키워드: parallel plate test

검색결과 91건 처리시간 0.039초

Assembling and Insulation Test of 1MVA Single Phase HTS Transformer for Power Distribution

  • Kim, S. H.;Kim, W. S.;Kim, J. T.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Lee, S. J.;S. Hahn
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권3호
    • /
    • pp.30-33
    • /
    • 2003
  • 1MVA high temperature superconducting (HTS) transformer with double pancake windings made of BSCCO-2223 HTS tapes was designed and manufactured. And prototype transformer with the same capacity was manufactured also. The each rated voltage of the HTS transformer is 22.9 kV and 6.6 kV. Four parallel BSCCO-2223 HTS tapes were wound in the double pancake windings of low voltage side. In order to distribute the currents equally in each HTS tapes, the three times transposition was performed between the double pancake windings. The windings of prototype transformer were wound using copper tape with the same size as BSCCO-2223 HTS tape. The core of the transformer was designed and manufactured as a shell type core made of laminated silicon steel plate. The several characteristics tests for the prototype transformer were performed in liquid nitrogen and insulation tests were accomplished also.

평형평판 간극사이에서 PIV를 이용한 ER유체의 유동특성에 관한연구 (A Study on Flow Characteristics of ERF Between Two Parallel-Plate by Using PlV)

  • 정완보;박영석
    • 한국공작기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.56-62
    • /
    • 2006
  • An experimental investigation was performed to study the characteristics of ER(Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF are clearly strong along the test tube and the flow rate decreased. In this study, the rheology of ER fluid stagnating or flowing through a dispersion meter will be investigated by PIV method. And then the ER effect, which appears at the ER valves and their appliance will be visualized.

경계요소법을 이용한 방음벽의 삽입손실 해석 (Analysis on the Insertion Loss of a Noise Barrier by the Boundary Element Method)

  • 이우섭;정성수;황철호
    • 소음진동
    • /
    • 제10권3호
    • /
    • pp.423-429
    • /
    • 2000
  • This paper investigates the use of boundary element method(BEM) to analyze the insertion loss of a noise barrier. To begin with the validity of the BEm for the analysis of noise barrier insertion loss in checked by both Lam's theoretical method and the measurements in the anechoic chamber for the scale-down models. Through simulation it is shown that using 2D BEM model is sufficient to the analysis for the barrier with large ratio of length to height. By using 2D BEM model the insertion loses are predicted for the real noise barriers in several cases which are the case that they are built parallel on both roadsides the one that there are multiple sound sources and the one that there is a gap between a concrete structure and a barrier plate.

  • PDF

지수형 온도변화를 이용한 표면 열전달의 측정 (Measurement of Surface Heat Transfer Using Exponential Temperature Variations)

  • 박병규;홍택;박상희
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1121-1128
    • /
    • 1999
  • A single blow, transient testing method for determining the heat transfer characteristics of heat exchanger surfaces are presented. The exponential inlet temperature variations were made using screen mesh with small time constant and frontal velocities of the test section. The system is used to investigate the usefulness of a model with exponential inlet temperature variations. A data reduction program is developed to calculate the temporally and spatially averaged heat transfer coefficient using the measured disturbance and response of the fluid temperature. The results are compared with the existing theoretical and experimental data for parallel plate stacks. It was recommended to take an average for the time greater than the 99% of the final temperature had reached in order to obtain fairly good results.

평행평판 전극사이에서 PIV 기법을 이용한 ER 유체의 유동특성에 관한 실험적 연구 (Experimental Study on Flow Characteristics of ERF Between Two Parallel-Plate Electrodes by using PIV Technique)

  • 장태현;장기원
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.103-106
    • /
    • 2003
  • An experimental investigation was peformed to study the characteristics of ER(Electro-Rheological) fluid water flow in a horizontal rectangular tube with or without D.C volatage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0 kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the claster of ERF are clearly strong along the test tube and the flow rate decreased.

  • PDF

An Experimental Study on Flow Characteristics of ERF Between Two Parallel-Plate Electrodes by Using PIV Technique

  • Chang, Tae-Hyun;Jang, Sung-Cheol
    • Journal of Mechanical Science and Technology
    • /
    • 제18권10호
    • /
    • pp.1763-1771
    • /
    • 2004
  • An experimental investigation was performed to study the characteristics of ER (Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D. C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique was employed for velocity measurements. This research found the mean velocity distributions with 0kV /mm, l.0kV /mm and l.5kV /mm for Re=0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF was clearly strong along the test tube and the flow rate decreased. The present results will contribute to the economical and compact design of ER fluids system.

Ozone Asher용(用) Ozone Generator 개발연구(開發硏究) (A Study of Electrolytic Ozone Generator for Ozone Asher)

  • 문재덕;우정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.648-651
    • /
    • 1993
  • A parallel plate type electrolytic ozone generator for ozone asher has been fabricated and studied, and 4 kinds of ozone generation anode electrode having different slits have also been investigated. It is found that there were optimum conditions for the slits of electrode, which, however, controls the field in the interelectrode spacing, and allows sideflow waterpaths through the slits in the electrode. As a result, the generated ozone concentrations of A, B, C and D type electrode showed 2.2, 1.3, 1.5 and 3.0 ppm for 400 ml/min flowrate tap water test, and, ozone yields of 11, 13, 15 and 30 $mg/kWhcm^2$ respectively.

  • PDF

회절격자와 층밀리기 간섭기술을 이용한 렌즈 굴절률 측정 (Use of a grating and a plane parallel glass plate for determinimg the refractive index of a lens)

  • 이윤우;조현모;이인원
    • 한국광학회지
    • /
    • 제3권1호
    • /
    • pp.16-19
    • /
    • 1992
  • 회절격자와 굴절률을 알고있는 액체내에 있는 렌즈사이의 퓨리에 변환관계를 이용하여 렌즈 굴절률에 대한 수식을 유도하였다. 층밀리기 간섭기술을 이용하여 정확한 렌즈의 후면촛평면의 위치를 결정하였으며 슬릿을 스텝핑 모터로 구동하는 이동장치에 부착시켜 회절격자의 퓨리에 변환 스펙트럼 간격을 축정하였다. 세가지 액체를 사용하여 얇은 렌즈의 굴절률을 측정하였으며 높은 측정정확도를 확인하였다.

  • PDF

모재의 두께와 용접치수에 따른 필릿용접부의 강도 (Effects of Plate Thickness and Weld Size on the Strength of Fillet Welded Lap Joints)

  • 조재병;정경섭;이정우
    • 한국강구조학회 논문집
    • /
    • 제18권3호
    • /
    • pp.331-337
    • /
    • 2006
  • 최근 고성능 대형 강구조물에 많이 적용되고 있는 TMC 강재에 대해 두께 20m, 60m, 82m의 후판을 6m~16mm의여러 용접치수로 필릿용접하여 겹이음부가 있는 시험체를 제작하고, 인장시험을 통하여 필릿용접부의 강도를 측정하였다. 측정된 필릿용접부의 강도는 모재의 두께, 용접 치수, 용접축에 대한 힘의 작용방향 등을 달리한 모든 경우에 설계기준에서 적용하고 있는 강도 계산식에 의한 공칭강도의 값보다 더 큰 것으로 나타났다. 특히 60mm와 82mm 두께의 모재에 대해 국내도 로교설계기준에서 요구하고 있는 최소 용접치수보다 더 작은 용접치수를 적용한 경우에도 시험체 제작과정에 용접의 어려움이나 용접부의 결함, 균열 등이 발견되지 않았으며, 용접부의 강도도 다른 경우와 거의 동일한 수준인 것으로 나타났다.

지능형 로봇 발을 위한 6 축 힘/모멘트센서 개발 (Development of 6-axis force/moment sensor for an intelligent robot's foot)

  • 김갑순;신희준;허덕찬;윤정원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1097-1102
    • /
    • 2007
  • This paper describes the development of 6-axis force/moment sensor for an intelligent robot's foot. In order to walk on uneven terrain safely, the foot should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz to itself. The applied forces and moments should be measured from a 6-axis force/moment sensor attached to a humanoid robot's foot(ankle). They in the published paper already have some disadvantage in the size of the sensor, the rated output and so on. The rated output of each component sensor (6-axis force/moment sensor) is very important to design the 6-axis force/moment sensor for precision measurement. Therefore, each sensor should be designed to be gotten similar the rated output under each rated load. So, the sensing elements of the 6-axis force/moment sensor should get lots of design variables. Also, the size of 6- axis force/moment sensor is very important for mounting to robot's foot. In this paper, a 6-axis force/moment sensor for perceiving forces and moments in a humanoid robot's foot was developed using many PPBs (parallel plate-beams). The structure of the sensor was newly modeled, and the sensing elements (plate-beams) of the sensor were designed using FEM (Finite Element Method) analysis. Then, the 6-axis force/moment sensor was fabricated by attaching strain-gages on the sensing elements, and the characteristic test of the developed sensor was carried out. The rated outputs from FEM analysis agree well with that from the characteristic test.

  • PDF