• 제목/요약/키워드: parallel line

검색결과 952건 처리시간 0.029초

Fault Line Detection Methodology for Four Parallel Lines on the Same Tower

  • Li, Botong;Li, Yongli;Yao, Chuang
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1217-1228
    • /
    • 2014
  • A method for faulted line detection of four parallel lines on the same tower is presented, based on four-summing and double-differential sequences of one terminal current. Four-summing and double-differential sequences of fault current can be calculated using a certain transformation matrix for parameter decoupling of four parallel transmission lines. According to fault boundary conditions, the amplitude and phase characteristics of four-summing and double-differential sequences of fault current is studied under conditions of different types of fault. Through the analysis of the relationship of terminal current and fault current, a novel methodology for fault line detection of four parallel transmission line on the same tower is put forward, which can pick out the fault lines no matter the fault occurs in single line or cross double lines. Simulation results validate that the methodology is correct and reliable under conditions of different load currents, transient resistances and fault locations.

무 손실 2-포트 회로의 인버터를 사용한 등가회로 및 응용 (A Equivalent Circuit for Lossless 2-Port Using Inverter and Its Application)

  • 양승식;염경환
    • 한국전자파학회논문지
    • /
    • 제19권7호
    • /
    • pp.761-770
    • /
    • 2008
  • 임피던스 인버터 및 어드미턴스 인버터는 마이크로파 여파기 설계에 자주 사용되는 개념적인 소자이다. 본 논문에서는 일반적 무 손실 2-포트 회로의 인버터를 사용한 등가회로를 제시하였다 이 방법은 기존의 방법과 달리 무손실 2-포트 회로의 z- 또는 y-파라미터를 알 경우, 이를 이용하여 용이하게 나타낼 수 있다. 이 방법을 평행 결합 선로(parallel coupled line) 및 비평행 결한 선로(anti-parallel coupled line)에 적용하고, 기존의 등가회로에 대하여 비교 검토하였다. 또한, 마이크로스트립 평행 결합 선로 여파기는 설계된 여파기에 대해 주파수 응답의 왜곡을 발생시키게 되는데, 이를 보상하기 위하여 알려진 기존 결과들과 본 논문의 유도 결과를 비교 검토하였다. 평행 결합 선로 여파기 설계시 제시된 등가회로는 기존 등가회로와의 차이로 여파기 설계에 특이성을 보이게 된다. 본 논문에서는 제시된 등가회로에 대하여 설계 방법을 제시하고, 기존의 연구 결과와 비교하여 제시된 방법이 보다 정확한 결과를 주는 것을 보였다.

765kV 2회선 송전선로를 765kV 및 345kV로 병행운전시 유도현상 예측 (Analysis of the electrostatic induction voltage and electromagnetic induction current on the Parallel Circuit in 765kV Double Circuit Transmission Line)

  • 우정욱;심응보;곽주식;전명렬;김기일;김태옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.169-171
    • /
    • 2002
  • The western route of KEPCO's 765kV transmission line has been tentatively operating as 345kV voltage before commercial operation. After finishing the test operation of 765kV substation in 2002. KEPCO decided to operate the 765kV line for commercial operation. During the applying of 765kV voltage to the transmission line, double circuit transmission line will be operated with two voltage grades of 765kV and 345kV. Because the earthing switch is installed on both end of transmission line, we had estimated the electrostatic induction voltage and electromagnetic induction current before the line energizing in order to confirm the ratings of earthing switch. The induced voltage and current is very important for the maintenance of parallel circuit. This paper describes the simulation study of electrical phenomena such as electrostatic induction voltage from the parallel line and electromagnetic induction current from the parallel circuit. The transmission line model was developed by EMTP (Electro-Magnetic Transient Program).

  • PDF

AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 라인 인터렉티브 무정전전원장치 시스템 (A Novel Three-Phase Line-Interactive UPS System having AC Line Reactor and Parallel-Series Active Filters)

  • 지준근
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2004년도 춘계학술대회
    • /
    • pp.193-197
    • /
    • 2004
  • The four-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. In this paper a novel line interactive Uninterruptible Power Supply(UPS) using the two four-leg VSCs is proposed. One VSC is in parallel with the ac link reactor of the power source side, and the other is in series with the load. The parallel four-leg voltage source inverter controls the three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series four-leg voltage source inverter compensates the line voltage and allows it to be balanced and harmonic-free. Both of the parallel and series four-leg voltage source inverters always act as independently controllable voltage sources, so that the three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulations results.

  • PDF

AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식 (Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Series Active Filter)

  • 지준근;김장환;설승기
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.538-546
    • /
    • 2007
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently. In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state. Therefore the experimental results to prototype UPS system having power rating of 60kVA is shown to prove the verification of voltage control strategy.

Parallel processing in structural reliability

  • Pellissetti, M.F.
    • Structural Engineering and Mechanics
    • /
    • 제32권1호
    • /
    • pp.95-126
    • /
    • 2009
  • The present contribution addresses the parallelization of advanced simulation methods for structural reliability analysis, which have recently been developed for large-scale structures with a high number of uncertain parameters. In particular, the Line Sampling method and the Subset Simulation method are considered. The proposed parallel algorithms exploit the parallelism associated with the possibility to simultaneously perform independent FE analyses. For the Line Sampling method a parallelization scheme is proposed both for the actual sampling process, and for the statistical gradient estimation method used to identify the so-called important direction of the Line Sampling scheme. Two parallelization strategies are investigated for the Subset Simulation method: the first one consists in the embarrassingly parallel advancement of distinct Markov chains; in this case the speedup is bounded by the number of chains advanced simultaneously. The second parallel Subset Simulation algorithm utilizes the concept of speculative computing. Speedup measurements in context with the FE model of a multistory building (24,000 DOFs) show the reduction of the wall-clock time to a very viable amount (<10 minutes for Line Sampling and ${\approx}$ 1 hour for Subset Simulation). The measurements, conducted on clusters of multi-core nodes, also indicate a strong sensitivity of the parallel performance to the load level of the nodes, in terms of the number of simultaneously used cores. This performance degradation is related to memory bottlenecks during the modal analysis required during each FE analysis.

평행라인 피봇식 추력베어링의 동특성 해석 (Dynamic Characteristics of Parallel Line Pivoted Pad Thrust Bearing)

  • 이경우;김종수;제양규
    • Tribology and Lubricants
    • /
    • 제16권4호
    • /
    • pp.274-281
    • /
    • 2000
  • In this paper, linearized dynamic characteristics of parallel line pivoted pad thrust bearing (here-inafter refer to PLP thrust bearing) was analyzed by perturbation method with inlet pressure. Inlet pressure and excitation frequency influence dynamic characteristics of PLP thrust bearing at all operating conditions, such as angular pivot position, mass of pad. Therefore, the characteristics have to be analyzed with inlet pressure, excitation frequency, mass of pad and thickness of pad. Otherwise, the analysis may be over or under estimate.

Developing Noninformative Priors for Parallel-Line Bioassay

  • Kim, YeongHwa;Heo, JungEun
    • Communications for Statistical Applications and Methods
    • /
    • 제9권2호
    • /
    • pp.401-410
    • /
    • 2002
  • This paper revisits parallel-line bioassay problem, from a Bayesian point of view using noninformative priors such as Jeffreys' prior, reference priors, and probability matching priors. After finding the orthogonal transformation, the class of first order and second order probability matching priors are derived. Jeffreys' prior and reference priors are derived also. Numerical examples are given to show the effectiveness of noninformative priors.

개방 스터브를 갖는 평행결합선로의 해석과 응용 (The Analysis and Application of the Parallel Coupled Line with Open Stub)

  • 이원균;이홍섭;황희용
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.153-160
    • /
    • 2007
  • In this paper, the exact analysis of the parallel coupled line with open stub is presented. This structure shows LPF characteristics with broad stopband and sharp skirt characteristics. We derived the exact Z-matrix expression of the structure. In order to show the validation of the expression we designed $3^{th}$ order Chebyshev LPF using the structure. The simulated data excellently agreed with the predicted values by the calculation using the derived expression.

  • PDF

대지귀로 전류에 의한 전력선과 통신선의 상호임피던스 해석 (Calculating Mutual Impedance between Power-Line and Communication-Line with Earth Return Current)

  • 임용훈;현덕화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.269-271
    • /
    • 2003
  • A method for calculation of mutual inductance from the parallel power-line and earth conduct to communication-line is studied in the paper. The solution for the electromagnetic field produced by an overhead power-line is derived using Maxwell's equations and treating the as a boundary value problem. Total mutual inductance from direct current and image current to communication-line is used Carson's formula for infinitely long parallel conductors.

  • PDF