• Title/Summary/Keyword: paper fire

Search Result 2,245, Processing Time 0.033 seconds

Temperature and Stress Analysis of Box Culvert in Fire (화재에 의한 지하공동구의 온도 및 응력해석)

  • Kim, Hyun-Jun;Im, Cho-Rong;Yoo, Hyeon-Kyeong;Chung, Chul-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.31-44
    • /
    • 2011
  • This paper has presented a finite element analysis of structural behaviour of box culvert during and after fires. The fire tests were carried out in a furnace on RC slabs using the ISO 834 standard fire curve. The load capacity after cooling of the RC slab that was not loaded during the fire tests was evaluated by means of additional 3 points bending tests. In the past, stress-strain models of concrete under fire loading have been proposed by several researchers. Comparisons are made with the load-displacement relations of RC slabs after fire loading using the existing stress-strain models with temperature, such as Schneider, EUROCODE 2, Lie, Shi and Nan model. By comparing the load-displacement relations, Lie model was found to result in a maximum load about 2.0% higher than that of test. Based on the fire test results of RC slabs, this paper presents an extensive analytical study on the fire response of box culvert during and after fires.

A Study on Authoritativeness of Electric Fire by Activating of Fire Damaged MCCB (소손된 배선용 차단기 동작상태에 의한 전기화재 규명의 신뢰성에 관한 연구)

  • Lee, Jong-Hwa;Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.

A Study on Fire Prevention Capability Performance Evaluation of the Phosphate Flame Retardant Honeycomb Core (인계 난연 허니컴 코아의 방화성능평가에 관한 연구)

  • Moon, Sung-Woong;Lim, Kyung-Bum;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.72-77
    • /
    • 2010
  • Honeycomb core structure with its excellent stiffness and strength is being utilized in many fields such as interior building material. Because it is inexpensive and renewable, honeycomb paper production is economically and environmentally helpful. However, the paper needs to be fireproofed because it is vulnerable to fire. In this study, we have undergone the performance evaluation process of the honeycomb paper which is widely used as interior material of a fire door and packing material. Four kinds of honeycomb (a honeycomb made of flame-resistant paper; a honeycomb attached with conventional flame-resistant film made in the laboratory; honeycomb impregnated with flame retardant; a honeycomb attached with flame-resistant film after impregnating fire retardant) were used in the study to compare the fire retardant performance. As a result, the honeycomb with impregnated flame retardant showed the highest performance. The flame-resistant film was effective in delaying the igniting time but had a negative effect on the rate of heat and smoke production.

A Survey Study on the Usage and Situation of Indoor Fire Hydrants (옥내소화전의 사용실태 및 현황에 관한 연구)

  • Lee, Wonjoo;Lee, Chang-Seop
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.141-146
    • /
    • 2016
  • The purpose of this paper is to investigate the basic data (e.g. education experience and awareness of the installation situation, and usage of indoor fire hydrants) for the effective planning, progress and improvement of fire safety education. For this purpose, we surveyed 198 participants and an analysis of the frequency and descriptive statistics based on the survey data was carried out using SPSS 20.0 for Windows. The analysis results showed that 87.9% of the research participants live in accommodation with indoor fire hydrants installed and that, among them, 17.7%, did not know their location. 63.6% of the research participants, had received fire safety education but, among them, 31.0% had never been educated about the use of indoor fire hydrants. The main type of fire education was instructor-led training, which represented 50.0% of the participants. We believe that the results of this paper will serve as a basis for efficient adult fire safety education.

The Application of Expert System in Fire Code Analysis (소방법규해석에 대한 EXPERT SYSTEM의 적용)

  • 김회천;손재열;김화중;박병윤
    • Fire Science and Engineering
    • /
    • v.3 no.3
    • /
    • pp.9-13
    • /
    • 1989
  • This paper realizers expert system which is searched most suitable system of the fire facilities by regulating of fire operating order And so, the user finds the inference, heuristic knowledge of the expert who has a mastery of application of the fire code objected protection, warning or extinguishing of fire. Although some expert systems utilize artificial intelligence such as LISP or PROLOG, this study utilizes M.1 that is available expert system development tool running with personal computer.

  • PDF

Synthetic Circumstantial Judgement System Applied Recognition of Fire Levels Model (화재 상황 인식 모델을 적용한 종합 상황 판단 시스템)

  • Song, Jae-Won;Lee, Se-Hee;An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1275-1281
    • /
    • 2011
  • This paper presents synthetic circumstantial judgement system that detects and predicts a fire in subway station. Unlike conventional fire surveillance systems that judge the fire or not through smoke, CO, temperature or variation of temperature, a proposed system discovers a fire more easily or gives the alarm high possibility of fire to operator through recognition of fire levels based on Fuzzy Inference System using by FCM and information of objects from video data.

  • PDF

Fire Detection System Using Arduino Sensor

  • Cheong, Ha-Young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.624-629
    • /
    • 2016
  • Recently various types of disaster monitoring system using smart-phones are under active studying. In this paper, we propose a system that automatically performs the disaster and fire detection. Additionally we implement the Arduino-based smart image sensor system in the web platform. When a fire is detected, an SMS is sent to the Fire and Disaster Management Agency. In order to improve fire detection probability, we proposed a smart Arduino fire detection sensor simulation which searches the smart sensor inference algorithm using fuzzy rules.

A practical approach for fire safety design of fire-resistant steel members

  • Li, Guo-Qiang;Ding, Jun;Sakumoto, Y.
    • Steel and Composite Structures
    • /
    • v.5 no.1
    • /
    • pp.71-86
    • /
    • 2005
  • Based on the test data of Nippon Steel Corporation, the formulas for calculating mechanical properties of fire-resistant (FR) steel at elevated temperatures have been established. A practical approach for fire safety design of FR steel members, including axially compressed members, flexural members and eccentrically compressed members, is developed in this paper. Compared with the full-scale specimen experiments and FEM numerical analysis, this practical approach for fire safety design of FR steel members is demonstrated to be effective and precise.

FIRE ENGINEERING IN EAST ASIA

  • Bressington, Peter
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.49-57
    • /
    • 1997
  • This paper examines the advantages of designing fire safety from first principles and the potential for this approach in East Asia. In order to show how this approach can be used, actual case studies are discussed. These studies demonstrate the way in which fire science and research can have a positive impact on fire safety design for buildings.

  • PDF

Evaluation of Salt Damage Resistance of Concrete according to Fire Control Time (화재진압시간에 따른 콘크리트의 염해저항성 평가)

  • Lee, Jun-Hae;Park, Dong-cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.109-110
    • /
    • 2020
  • In the event of a fire, fire engines usually arrive within 15 minutes and become a fire suppressor. In this paper, an analytical model was established to evaluate the salt damage resistance of concrete according to fire suppression time, and the concentration of salt inside the concrete after fire was measured and the time to reach the critical concentration was assessed by how short.

  • PDF