• Title/Summary/Keyword: paper fire

Search Result 2,237, Processing Time 0.037 seconds

A FORECASTING METHOD FOR FOREST FIRES BASED ON THE TOPOGRAPHICAL CLASSIFICATION SYSTEM AND SPREADING SPEED OF FIRE

  • Koizumi, Toshio
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.311-318
    • /
    • 1997
  • On April 27,1993, a forest fire occurred in Morito-area, Manba-city, Gunma-prefecture Japan. Under the prevailing strong winds, the fire spread and extended to the largest scale ever in Gunma-prefecture. The author chartered a helicopter on May 5, one week after the fire was extinguished, and took aerial photos of tile damaged area, and investigated the condition. of the fire through field survey and data collection. The burnt area extended. over about 100 hectares, and the damage amounted to about 190 million yen (about two million dollar). The fire occurred at a steep mountainous area and under strong winds, therefore, md and topography strongly facilitated the spreading, It is the purpose of this paper to report a damage investigation of the fire and to develop the forecasting method of forest fires based on the topographical analysis and spreading speed of fire. In the first place, I analyze the topographical structure of the regions which became the bject of this study with some topographical factors, and construct a land form classification ap. Secondly, I decide the dangerous condition of each region in the land form classification map according to the direction of the wind and spreading speed of f'kre. In the present paper, I try to forecast forest fires in Morito area, and the basic results for the forecasting method of forest fires were obtained with the topographical classification system and spreading speed of fire.

  • PDF

A Study on the Characteristics of Fire Service Organization Structure (소방조직의 구조적 특성에 관한 연구)

  • Lee, Wonjoo
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.164-170
    • /
    • 2019
  • This paper discusses the characteristics of the fire service organization structure in the Republic of Korea. The subjects of the study were selected by the fire service organization consisting of public firefighters in the Republic of Korea. The characteristics of the fire service organization structure (complexity, centrality, and officiality) were confirmed by various articles and previous references. The fire service organization showed a mechanical structure and bureaucratic organization. The levels of complexity, centrality, and officiality in the characteristics of fire service organization structure were higher than those of a general administration organization or company organization. In conclusion, this paper contributes to the development of fire service organization theory by confirming the characteristics of fire service organization structure.

A Study on the Fire Resisting Properties of Reinforced Concrete Structures (철근콘크리트 구조물의 내화성능에 관한 연구)

  • 김무한;송하영
    • Fire Science and Engineering
    • /
    • v.2 no.1
    • /
    • pp.3-10
    • /
    • 1988
  • Concrete is incombustible and has good fire resisting properties, i. e. when exposed to fire it continues to perform satisfactorily for a reasonable period of time. Nevertheless, with time and high temperature gradient, brought about the fire, causes cracking and spatting. Further deterioration and loss of strength are caused by gradual dehydration of concrete paste. This paper is aimed to make a proposal for the design and construction of reinforced concrete structures with more sufficent resistance to fire by the theoritical analysis, which is base4 on investigation of general damages by the fire and change of properties on concrete influenced by high temperature.

  • PDF

조사연구-선박용 소화기에 관한 지침

  • Park, Yeong-Geun
    • Fire Protection Technology
    • /
    • s.18
    • /
    • pp.21-27
    • /
    • 1995
  • This paper is aimed to introduce the related marine type fire extinguishers standards between the domestic and the abroad. This is based on the fire extinguishers at chapter 2 -2 Regulation 6. of the International Convention for the Safety of Life at Sea. 1974, and Guidelines for Marine Portable Fire Extinguishers at Internation-al Maritime Organization Annexed Resolution A. 602 (15)

  • PDF

The variation of droplet velocity in a fire plume (플룸을 통과하는 수적의 속도변화)

  • Kim, Jin-Guk
    • Fire Protection Technology
    • /
    • s.23
    • /
    • pp.15-19
    • /
    • 1997
  • The objective of this paper is to present a equation which can give some insight of the behavior of droplet in a fire plume. The equation is derived with a number of engineering relations drawn from the literature for calculating properties of fire plume. Plume properties considered here include temperatures, velocities and virtual origin. In addition, the drag force for a sphere and the energy equation are considered.

  • PDF

An Experimental Study on the Fire Hazards in Electric Heater (전기히터의 화재위험성에 관한 실험연구)

  • Hong, Sung-Ho;Lee, Bock-Young;Park, Sang-Tae;Yu, Hyun-Jong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.2 s.80
    • /
    • pp.36-40
    • /
    • 2007
  • This study presents on the analysis fire hazards of electric heater. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate normal condition and abnormal condition. The abnormal condition experiment is simulated in which combustibles are placed near by electric heater. Vertical burning test(UL 94) is conducted for the fire retardant experiment. The results show that fire hazard is high in case of abnormal condition. And Material of electric heater has not fire retardant performance. In this paper, we suggest to add temperature fuse in electric heater for reducing fire hazard.

Analysis for the Thermal Properties of the Electrical Wire according to Overload and Disconnection (과부하 및 물리적 손상(반단선)에 의한 전선의 열적특성 해석)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.26-31
    • /
    • 2007
  • According to the statistical analysis on the electrical fire of 2005 years, most of electrical fire is generated from short circuit(4,985 cases), overcurrent(755 cases) leakage current(391 cases), poor contact(378 cases), disconnection(36 cases) on the electrical wiring device. The researches for the fire hazard about normal electric wiring have already been progressing in the advanced country such as USA and Japan, but Comparative study of the disconnection has not been conducted. Therefore, in this paper, we have simulated the thermal analysis for electrical wire according to deteriorating time in a normal state and disconnection with electrical wire using the electrical-thermal finite element method(Flux 3D). This paper acquire basis data of electricity fire signal by disconnection and wish to help for electrical fire cause diagnosis business.

A Study on the Unique point about the Tracking at Electrical fire spot (화재현장에서 분석 절차에 따른 전기화재 조사기법 개발)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2130-2131
    • /
    • 2011
  • Electric fire breaks out by various causes such as electric short, overload(over current), leakage current, poor contact, static electricity, insulation deterioration, partial disconnection and etc. In this paper, we studied analysis technique for scientific and systematic judgment for distinction of electricity fire existence and nonexistence, and described about electricity fire cause analysis process for collecting physical evidences. We handled external form analysis, Substance extension analysis, X-ray transmission analysis, cross-section analysis, thermal analysis, chemical structure analysis, surface structure analysis, component analysis, electrical properties analysis, and circuit analysis by analysis technique for electricity fire cause judgment. We expect that analysis technic elevation and correct cause of fire analysis of scene of a fire investigators and analysts through this paper which see help.

  • PDF

Performance Based Fire Engineering in Japan

  • Kohno, Mamoru;Okazaki, Tomohito
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.23-30
    • /
    • 2013
  • This paper explains the Japanese present situations relevant to the fire resistance performance. Performance-based fire provisions was introduced in 1998 for the first time when the Building Standard Law was amended. However, performance-based fire resistance design had been used since long before the official introduction of performance-based provisions. A Comprehensive Technology Development Project of Ministry of Construction from 1982 to 1986 established a technical basis for performance-based fire safety engineering in Japan. A system of calculation methods for fire resistance verification was prescribed in the Ministry Notification in 2000 utilizing the results of this project as a background. This method, referred to as the Fire Resistance Verification Method (FRVM), is the standard method to verify the fire resistance performance of principal building parts such as columns, beams, and walls of steel, concrete, or wood structured buildings. For tall buildings, however, more advanced method for performance verification is often necessary because new building materials or structural systems are often used for these buildings. An example project of tall building owned by a major newspaper company is presented in this paper. Advanced thermal deformation analysis is executed to secure the fire resistance of the building.