• Title/Summary/Keyword: panels

Search Result 2,707, Processing Time 0.03 seconds

A Study on the functional pattern design for brassiere-focusing on large-breasted women- (기능성 브래지어 패턴디자인 연구 -돌출.하수 유방유형을 중심으로-)

  • Park, Eun-Mi;Im, Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.3_4
    • /
    • pp.407-417
    • /
    • 2003
  • The purpose of this study is to develop designs and patterns of a functional brassiere. For this purpose, women who have protruding and drooping breasts with 75B for their brassiere size were sampled. The fitting test for the fitness and function of test brassiere and control brassiere were carried out twice and compared the results from the both in terms of front, rear and side looks. The results of this study can be summarized as follows; 1. The results from measuring the level of sag and spread, and volume and protrusion of breasts shows that there are some distinctive differences in the measurements before and after wearing the test brassiere and the test brassiere is proved to be very effective in correcting breasts' shapes. 2. Front look: Since the two front cutting lines of the test brassiere served to have the curved main part pressing against the breasts, it could support breasts to more than satisfactory level. In addition, upperline panel and side panels of the test brassiere were found to have the upperline of the upper cup pressed against the breasts and at the same time it pressed and gathered the flab around upper part of the breasts and armpits that helped to rearrange the shape of the breasts. It is also proved that the two-pieced test brassier was found to be more functional in supporting the lower cup of the breasts. 3. Rear look: The test brassier was made up of two wide U-shaped wings with 2.5cm tape on its lower sides. Each wing has 4 lines and 3 hems (5.5cm). For this reason, the test brassiere was tighter and better fitted on its back. 4. Side look and entire look: The wings of the test brassiere might look wider than that of the control brassier which has conventional straight-shaped wings, but it was analyzed that the test brassiere held the upper and lower sides of the wings more effectively to be more pressed against the breast. Therefore, the test brassiere scored higher in terms of adjusting to body movements, while the control brassiere looked better in overall terms. 5. The functional brassier fur protruding and drooping breasts developed from the experiments of this study is a full side stretch brassiere which covers the entire breasts satisfactorily. The pattern drafting methods are suggested in to .

Design of a Prototype System for Graft-Taking Enhancement of Grafted Seedlings Using Artificial Lighting - Effect of air current speed on the distribution of air temperature and relative humidity in a graft-taking enhancement system (인공광을 이용한 접목표 활착촉진 시스템의 시작품 설계 - 활착촉진 시스템 내의 기온과 상대습도 분포에 미치는 기류속도의 효과)

  • 김용현
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.213-220
    • /
    • 2000
  • Grafting of fruit-bearing vegetables has been widely used to increase the resistance to soil-borne diseases, to increase the tolerance to low temperature or to soil salinity, to increase the plant vigor, and to extend the duration of economic harvest time. After grafting, it is important to control the environment around grafted seedlings for the robust joining of a scion and rootstock. Usually the shading materials and plastic films are used to keep the high relative humidity and low light intensity in greenhouse or tunnel. It is quite difficult to optimally control the environment for healing and acclimation of grafted seedlings under natural light. So the farmers or growers rely on their experience for the production of grafted seedling with high quality. If artificial light is used as a lighting source for graft-taking of grafted seedlings, the light intensity and photoperiod can be easily controlled. The purpose of this study was to develop a prototype system for the graft-taking enhancement of grafted seedlings using artificial lighting and to investigate the effect of air current speed on the distribution of air temperature and relative humidity in a graft-taking enhancement system. A prototype graft-taking system was consisted by polyurethane panels, air-conditioning unit, system controller and lighting unit. Three band fluorescent lamps (FL20SEX-D/18, Kumho Electric, Inc.) were used as a lighting source. Anemometer (Climomaster 6521, KANOMAX), T-type thermocouples and humidity sensors (CHS-UPS, TDK) were used to measure the air current speed, air temperature and relative humidity in a graft-taking system. In this system, air flow acted as a driving force for the diffusion of heat and water vapor. Air current speed, air temperature and relative humidity controlled by a programmable logic controller (UP750, Yokogawa Electric Co) and an inverter (MOSCON-G3, SAMSUNG) had an even distribution. Distribution of air temperature and relative humidity in a graft-taking enhancement system was fairly affected by air current speed. Air current speed higher than 0.1m/s was required to obtain the even distribution of environmental factors in this system. At low air current speed of 0.1m/s, the evapotranspiration rate of grafted seedlings would be suppressed and thus graft-taking would be enhanced. This system could be used to investigate the effects of air temperature, relative humidity, air current speed and light intensity on the evaportranspiration rate of grafted seedlings.

  • PDF

Effects of Addition of Mugwort Powder on the Quality Characteristics of Emulsion-type Sausage (쑥 분말 첨가가 유화형 소시지의 품질특성에 미치는 영향)

  • Lee, J.R.;Hah, Y.J.;Lee, J.W.;Kim, K.S,;Lee, J.D.;Kim, K.S.;Lee, J.D.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.209-216
    • /
    • 2004
  • This study was carried out to investigate the effects of addition of mugwort powder 0.7%, 10/0, 2%) on the quality characteristics of emulsion-type sausages. The pH, color, TBARS, textural properties, minerals content and sensory evaluation were evaluated. The pH values of sausage containing mugwort powder were significantly lower as compared to control during 20 days of storage, but there were higher than those of control at 40 days of storage. The $L^*$ and $a^*$ values of sausage containing mugwort powder were significantly lower as compared to control, but the $b^*$ values were significantly higher in the sausage containing mugwort powder. The TBARS values of sausage containing mugwort powder were significantly lower than those of control at 20 and 45 days of storage. The hardness values of sausage containing mugwort powder were significantly lower than those of control. The Na content of sausage containing mugwort powder were significantly lower as compared to control, but Mg, Ca, Mn and Fe contents were significantly higher in the sausage containing 2%l mugwort powder. Sensory panels evaluated that sausage containing mugwort powder had the higher preference scores in mugwort flavor.

Analysis of visible light communication system using 15 watt LED and 40 watt solar panel (소형 창고형 공장 적용을 고려한 15와트 LED 조명과 40와트 태양광 패널을 활용한 가시광통신 송수신 시스템 분석)

  • Woo, Deok Gun;Mariappan, Vinayagam;Park, Jong Yong;Lee, Jong Hyeok;Kim, Young Min;Cha, Jae Sang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.5
    • /
    • pp.608-614
    • /
    • 2018
  • In addition to the diffusion of ICT technology, various protocols of short range wireless communication technology are being applied for efficient information operation. However, due to limitations of short-range wireless communication, communication is not smooth in places where frequency environment is poor, such as frequency confusion and warehouse type factory. When an alternative is needed. The development of LED technology and expansion of infrastructure through LED based visible light communication is attracting attention as an alternative and spreading the usage in wide range now a days. In addition, the infrastructure has been expanded with solar panels in response to the development of smarthome built-in with renewable energy. In this situation, visible light communication using PD has been limitedly applied in a near environment where the receiving angle of the PD and the ambient light ensure the LoS and the influence of the ambient light is small. In order to solve this problem, we have implemented visible light communication using LED lighting with large current infrastructure and solar panel with large receiving area, and proposed a circuit for restoring accurate data even in ambient light. Through this study results, it is expected that visible light communication can be more widely used and this result used as the base data for visible light communication research using the solar panel as the receiver.

Estimation of buckling and collapse behaviour for continuous stiffened plate under combined transverse axial compression and lateral pressure (조합하중을 받는 연속보강판의 좌굴 및 붕괴거동 평가)

  • Park, Joo-Shin;Choi, Joung-Hwan;Hong, Kwan-Young;Lee, Gyoung-Woo
    • Journal of Navigation and Port Research
    • /
    • v.33 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • Estimation of the buckling and ultimate strength of a continuous stiffened plate subjected to combined transverse compression and lateral pressure is of high importance to ensure the safety of ship structures, particularly for the bottom plating under a deep draft condition For example, bottom plating of bulk carriers is subjected to transverse thrust caused by the bending of double bottom structure and the direct action of pressure on the side shells. Most of experimental tests, theoretical approach and numerical researches have been performed on the buckling and ultimate strength behaviour of plates or stiffened plates under combined compression and lateral pressure. With regard to stiffened panels, however, most of studies have been concerned with the load conditions of combined longitudinal thrust and lateral pressure, while fewer studies have been performed for the combined transverse thrust and lateral pressure. In addition, the previous researches are mainly concerned with an isolated rectangular plate simply supported along the all edges, whereas actual ship plating is continuous across the transverse frames and heavy girders. In the present paper, a series of elastoplastic large deflection FEA on a continuous stiffened plate is performed and then clarify the characteristic of collapse mode and explain the effect of transverse compression.

Seismic Performance Assessment of a Composite Modular System Considering Stiffness of Connections (접합부 강성을 고려한 합성 모듈러 시스템의 내진 성능평가)

  • Choi, Young-Hoo;Lee, Ho-Chan;Kim, Jin-Koo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.105-114
    • /
    • 2018
  • Modular system can be divided into two types based on the methods of resisting load. The one is the open-sided modular system composed of beams and columns. The other is the enclosed modular system composed of panels and studs. Of the Modular systems, the use of open-sided modular system is limited because it consists of closed member sections. In order to solve this problem, Choi et al.(2017) proposed a composite modular system with folded steel members filled with concrete. However, it was assumed in the previous study that the connections between modules are composed of rigid joint. Therefore it didn't identify the effect of connection behavior in structure. This study used finite element analysis to calculate stiffness of the connections in the proposed modular system. The linearization method presented in FEMA 440 is used for seismic performance assessment of structures, considering the connection stiffness computed in this study. The result of analysis shows that the capacity and story drift ratio obtained in the model considering stiffness of connection are less than those in the model not considering connection stiffness. Based on this observation, it is concluded that the stiffness of connection has a considerable effect on structural behavior.

An Experimental Study on the Behavior of Small Scale Curved Panel Using Composite Materials (복합소재를 활용한 곡면 패널 축소형 실험체의 구조 성능 평가)

  • Park, Hee Beom;Park, Jong-Sup;Kang, Jae-Yoon;Jung, Woo-Tai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2018
  • FRP is a new material that is light, has high strength and high durability, and is emerging as a third construction material inside and outside of countries. However, very few studies have been done on curved FRP construction materials that can be used for tunnels or arched bridges. Because a small composite panel specimen is smaller than a full-size specimen, it can be used in a variety of experiments under different conditions. Therefore, in this study, experiments were performed on a void section, a solid section, a connected solid section, and a sand-coating solid section. The results of the experiment show that the connection of composite curved panels with longitudinal connections provides almost equivalent performance to that of a single panel. However, it is necessary to strengthen the connections, since the connections that are most susceptible to damage will break first.

Experimental validations of fire-resistant materials for protecting LPG small storage tank from building fires (건물 화재 시 LPG소형저장탱크 보호용 화재 저항 재료 성능 실증)

  • Kim, Seung-Hwan;Kim, Kyung-Sik;Heo, Seung-Geon;Lee, Jae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.18-24
    • /
    • 2020
  • The purpose of this study is to validate thermal hinderance effects, i.e., feasibilities, of fire-proof structure for LPG tank exposed to fire from adjacent burning building. The panel materials suggested for the fire-proof structure are (1) 10 mm-thick wood, (2) wood with fireproof coating, (3) 75 mm-thick Expanded Polystyrene, (4) 75 mm-thick glass wool filled sandwich panel, and (5) 75 mm-thick autoclaved lightweight concrete. The square planar fire source of 1 ㎡, a matrix of nozzles releasing 120-140 g/s of LPG, is used to heat up the wall and the tank beyond, mimicking heat transfer from burning exterior wall finishes. The feasibility is tested by inspecting structural integrity after test, and then by examining temperatures at both sides of panels and tank's front surface as well as heat fluxes. As a result, it can be concluded that, among the suggested sample materials, fire-proof wall with ALC panel only showed the feasibility for explosion prevention with the proven evidences of structural integrity and least increase in temperature of tank.

Three-dimensional measurement of electron temperature and plasma density in coplanar AC plasma display panels (면방전 AC-PDP에서의 전자온도와 플라스마 밀도의 3차원 진단)

  • Jeong, S.H.;Moon, M.W.;Park, W.B.;Lee, J.H.;Lim, J.E.;Lee, H.J.;Son, C.G.;Lee, S.B.;Yoo, N.L.;Han, Y.G.;Oh, P.Y.;Ko, B.D.;Jeoung, J.M.;Seo, Yoon-Ho;Cho, Guang-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.139-141
    • /
    • 2005
  • 이번 실험에서는 변방전형 교류 PDP에서의 3차원적인 전자온도와 이온밀도의 측정을 마이크로 랑뮈르 탐침법을 통해 실험적으로 연구하였다. 스테핑 모터에 연결된 마이크로 랑뮈르 탐침은 20um씩 움직이며 탐침에 인가하는 플러스와 마이너스의 직류전압을 통해 I-V곡선을 구할 수 있고 이를 통해서 전자온도와 플라스마 밀도를 구할 수 있다. Ne+Xe(4%) 200Torr의 혼합가스에서 전극의 테두리를 따라(X축) 전자온도 및 플라스마 밀도를 측정한 결과 중앙지점에서와 전극의 경계지역에서 이온밀도는 $7.69{\sim}11.1{\times}10^{11}cm^{-3}$ 까지 측정되었다. 또한 전자온도는 플라스마 밀도와 균형적인 관계에 있다는 것은 주목할 만하다. 전자온도는 전극 사이의 중심에서 가장 적게 1.3 ~ 3.15eV까지 측정되었다. Y축으로 측정했을 경우 이온 밀도와 전자온도는 전극 갭 중앙에서부터 약 80um 떨어진 지점에서 서로 교차하며 증가 및 감소였으며 이온밀도는 $8.3{\sim}11.1{\times}10^{11}cm^{-3}$로 측정되었고 전자온도는 이와 균형적인 관계를 가지고 1.2~1.6eV로 측정되었다. 또한 이러한 특성은 AC PDP 에서 나타나는 줄무늬 현상과 관련이 있는 것으로 보인다. Z축으로 측정했을 경우 약 125um높이에서 가장 높게 측정되었으며 $1.1{\times}10^{12}cm^{-3}$정도로 측정되었다.

  • PDF

High rate deposition of poly-si thin films using new magnetron sputtering source

  • Boo, Jin-Hyo;Park, Heon-Kyu;Nam, Kyung-Hoon;Han, Jeon-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.186-186
    • /
    • 2000
  • After LeComber et al. reported the first amorphous hydrogenated silicon (a-Si: H) TFT, many laboratories started the development of an active matrix LCDs using a-Si:H TFTs formed on glass substrate. With increasing the display area and pixel density of TFT-LCD, however, high mobility TFTs are required for pixel driver of TF-LCD in order to shorten the charging time of the pixel electrodes. The most important of these drawbacks is a-Si's electron mobiliy, which is the speed at which electrons can move through each transistor. The problem of low carier mobility for the a-Si:H TFTs can be overcome by introducing polycrystalline silicon (poly-Si) thin film instead of a-Si:H as a semiconductor layer of TFTs. Therefore, poly-Si has gained increasing interest and has been investigated by many researchers. Recnetly, fabrication of such poly-Si TFT-LCD panels with VGA pixel size and monolithic drivers has been reported, . Especially, fabricating poly-Si TFTs at a temperature mach lower than the strain point of glass is needed in order to have high mobility TFTs on large-size glass substrate, and the monolithic drivers will reduce the cost of TFT-LCDs. The conventional methods to fabricate poly-Si films are low pressure chemical vapor deposition (LPCVD0 as well as solid phase crystallization (SPC), pulsed rapid thermal annealing(PRTA), and eximer laser annealing (ELA). However, these methods have some disadvantages such as high deposition temperature over $600^{\circ}C$, small grain size (<50nm), poor crystallinity, and high grain boundary states. Therefore the low temperature and large area processes using a cheap glass substrate are impossible because of high temperature process. In this study, therefore, we have deposited poly-Si thin films on si(100) and glass substrates at growth temperature of below 40$0^{\circ}C$ using newly developed high rate magnetron sputtering method. To improve the sputtering yield and the growth rate, a high power (10~30 W/cm2) sputtering source with unbalanced magnetron and Si ion extraction grid was designed and constructed based on the results of computer simulation. The maximum deposition rate could be reached to be 0.35$\mu$m/min due to a high ion bombardment. This is 5 times higher than that of conventional sputtering method, and the sputtering yield was also increased up to 80%. The best film was obtained on Si(100) using Si ion extraction grid under 9.0$\times$10-3Torr of working pressure and 11 W/cm2 of the target power density. The electron mobility of the poly-si film grown on Si(100) at 40$0^{\circ}C$ with ion extraction grid shows 96 cm2/V sec. During sputtering, moreover, the characteristics of si source were also analyzed with in situ Langmuir probe method and optical emission spectroscopy.

  • PDF