Thermomechanical Properties of Thermal-Stress Relief Type of Functionally Gradient Materials

  • Watanabe, Ryuzo
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 1993년도 추계학술강연 및 발표대회강연 및 발표논문 초록집
    • /
    • pp.2-2
    • /
    • 1993
  • The present status of the thennomechanica1 evaluation of functionally gradient materials(FGMs) for space plane application was reviewed, in which research activities and the cooperation of the national project team organized to study FGM science were demonstrated. The project team was divided into three working groups; de singing, processing and evaluation, each of which had their own tasks in the project cooperation. The testings details of the various thennomechanical tests for the FGM samples fabricated by the processing groups were described, along with their corresponding heating conditions of the real environments in the space plane application. For small-sized samples, laser beam heating test and burner heating test were well applied to study the heat shielding and heat resisting properties. Arc-heated wind tunnel test and high temperature!high velocity gas flow test were used for large-sized panel assemblies having cooling structures. The criteria for the evaluation of the heat shielding and heat resisting properties of the FGMs, as well as a crack activation mechanism in their differential temperature heating, were proposed on the basis of the observation in the burner heating test.

  • PDF

이중금속융출형 온돌판넬을 이용한 바닥온수난방시스템의 난방성능과 에너지소비량에 관한 실험적 연구 (Experimental Study on Consumption of Energy and Heating Efficiency in Floor Water Heating System on Using Ondol Panel of Double Metal Rendering)

  • 배대권;김진봉;김환성
    • 한국산학기술학회논문지
    • /
    • 제13권12호
    • /
    • pp.6167-6175
    • /
    • 2012
  • 본 연구는 개발된 온돌판넬을 이용한 바닥난방공법의 품질검증을 위한 실험적 연구이다. 이를 위해 현행기술인 표준바닥구조에 의한 난방시스템과 본 개발기술의 난방성능을 측정비교 하였다. 그 결과, 온수온도 $45^{\circ}C$, 8시간 공급시 개발기술의 몰탈표면부 온도는 $49.4^{\circ}C$, 배관사이 중앙부는 $44.1^{\circ}C$, 공기층은 $25.3^{\circ}C$로 나타났다. 반면, 현행기술의 몰탈표면부는 $46.2^{\circ}C$, 배관사이 중앙부는 $37.7^{\circ}C$, 공기층은 $24.7^{\circ}C$로 나타났다. 한편, 온수온도 $45^{\circ}C$일 때 개발기술의 누적 에너지소비량은 4,646 kcal, 현행기술은 4,814 kcal로써 개발기술이 기존 기술보다 적게 나타났다.

경량칸막이 벽체재료의 수열온도에 따른 전도 열전달 특성 연구 (Study on the Conduction Heat Transfer Characteristics According to the Heating Temperature of Lightweight Panel Wall material)

  • 박상민;이호성;최수길;김시국
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.46-56
    • /
    • 2018
  • 본 논문은 경량칸막이 벽체재료의 수열온도에 따른 전도 열전달 특성에 관한 연구이다. 경량칸막이 벽체재료로 사용되고 있는 대표적인 소재인 일반석고보드, 방화석고보드를 포함하여 합판, 대리석, 내열유리를 실험시료로 선정하였고, 수열온도를 $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$로 설정하였다. 그 후 벽체재료 하단부에 각각의 수열온도를 30분 동안 인가하여 상단부인 이면부로의 전도 열전달 특성을 분석하였다. 실험결과 수열온도가 최대 $600^{\circ}C$로 인가됨에 따라 최대 이면온도는 일반석고보드 $190^{\circ}C$, 방화석고보드 $198^{\circ}C$, 합판 $189^{\circ}C$, 대리석 $321^{\circ}C$, 내열유리 $418^{\circ}C$까지 측정되었다. 또한, 수열온도가 최대 $600^{\circ}C$로 인가됨에 따라 전도 열전달율의 최대 변화폭은 일반석고보드 85 W, 방화 석고보드 95 W, 합판 67 W, 대리석 1686 W, 내열유리 3196 W 까지 측정되었다. 추가적으로 전도 열전달의 위험성을 가시적으로 확인하기 위해 벽지의 탄화특성 측정결과 수열온도 $600^{\circ}C$의 경우 부착된 벽지의 최초연기발생은 일반석고 보드 1021 s, 방화석고보드 978 s, 합판 1395 s, 대리석 167 s, 내열유리 20 s에 나타났고, 최초탄화발생은 일반석고보드 1115 s, 방화석고보드 1089 s, 합판 1489 s, 대리석 192 s, 내열유리 36 s에 나타났다.

Behavior of UHPC-RW-RC wall panel under various temperature and humidity conditions

  • Wu, Xiangguo;Yu, Shiyuan;Tao, Xiaokun;Chen, Baochun;Liu, Hui;Yang, Ming;Kang, Thomas H.K.
    • Advances in concrete construction
    • /
    • 제9권5호
    • /
    • pp.459-467
    • /
    • 2020
  • Mechanical and thermal properties of composite sandwich wall panels are affected by changes in their external environment. Humidity and temperature changes induce stress on wall panels and their core connectors. Under the action of ambient temperature, temperature on the outer layer of the wall panel changes greatly, while that on the inner layer only changes slightly. As a result, stress concentration exists at the intersection of the connector and the wall blade. In this paper, temperature field and stress field distribution of UHPC-RW-RC (Ultra-High Performance Concrete - Rock Wool - Reinforced Concrete) wall panel under high temperature-sprinkling and heating-freezing conditions were investigated by using the general finite element software ABAQUS. Additionally, design of the connection between the wall panel and the main structure is proposed. Findings may serve as a scientific reference for design of high performance composite sandwich wall panels.

TAP을 적용한 내단열과 외단열구조의 열성능 평가에 관한 연구 (A Study on Thermal Performance Evaluation with TAP (Thermosyphoning Air Panel) in Inside and Outside Insulated Constructions)

  • 이경회;유호천;홍영우;전채휘
    • 태양에너지
    • /
    • 제7권1호
    • /
    • pp.23-29
    • /
    • 1987
  • TAP system, a kind of natural convective space heating collector, has a good heat loss by night. The aim of this paper is to induce and to study an hourly heat flow theory by response factors analysis with TAP in inside and outside insulated construction, to compare and evaluate on thermal performance an hourly natural temperature, heated room temperature and heating load in aboved-mention constructions with computer simulation. The results of the study can be summarized as follows. According that there is no TAP and with TAP, it is inside insulated construction and outside insulated construction, daily natural range of temperature each shows $12.5^{\circ}C$ and $16.7^{\circ}C$, $2.7^{\circ}C$ and $3.7^{\circ}C$, daily heated range of temperature with noramal control heating system each shows $6.6^{\circ}C$ and $12.1^{\circ}C$, $1.7^{\circ}C$ and $3.1^{\circ}C$, heating hours each show 10 hr and 7 hr, 9 hr and 4 hr and heating energy saving percentage in january 123% and 79%, 100% and 40%. Therefore, energy saving percentage shows that outside insulated construction saves about 54% in comparision with inside insulated construction.

  • PDF

급기가 되는 이중바닥 구조체의 열 성능 평가 (Estimation of the thermal performance on the double slab floor with supplying air)

  • 차광석;박명식;이대우;남우동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

난방부하와 온수온돌의 방열성능을 고려한 적정 공급온수온도 산출방법에 관한 연구 (A Study on the Method of Estimating Optimum Supply Water Temperature Considering the Heating Load and the Heat Emission Performance of Radiant Floor Heating Panel)

  • 최정민;이규남;류성룡;김용이;여명석;김광우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.795-800
    • /
    • 2006
  • A common approach to achieve better thermal comfort with hydronic radiant floor heating system is supply water temperature control. This is the control method through which supply water temperature is varied with outdoor temperature. In this study, a comprehensive, yet simple calculation method to find optimum supply water temperature is evaluated by combining heat loss from the building and heat emission from the hydronic radiant floor heating system. And then the control performance of suggested calculation method is confirmed through experiment. It is shown that indoor air temperature is stably maintained around the set point.

  • PDF

The Outgasing characteristics of MgO film for protecting layer of plasma display panel

  • Song, Byoung-Kwan;Lee, Young-Joon;Lee, Chang-Heon;Hwang, Hyun-Ki;Yeom, Guen-Young
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.621-624
    • /
    • 2002
  • In this study, outgassing characteristics of MgO films, and the plasma cleaning effects of the deposited MgO films by atmospheric pressure plasma on outgassing rate were compared. The MgO layer was heated up to 350 $^{\circ}C$ and the outgassing characteristics were observed for the heated conditions. As the main impurity species $H_2,\;H_2O,\;N_2,\;CO_2,\;and\;H_2O$ were released from this panel. Impurity species of plasma treatment panel were lower than non-treated panels for the heating temperature

  • PDF

CFX를 이용한 내부순환모드에서의 자동차 내부 유동특성 연구 (A study on Flow Characteristic inside Passenger's Compartment under Recirculation Cool vent mode using CFX)

  • 김윤기;양장식;김경천;지호성
    • 한국가시화정보학회지
    • /
    • 제8권1호
    • /
    • pp.25-30
    • /
    • 2010
  • The flow characteristics under recirculation cool vent mode is numerically studied using commercial fluid dynamic code(CFX). For the reliable analysis, real vehicle and human FE model is employed in grid generation process. The geometrical location and shape of panel vent, and exhaust vent is set as that of real vehicle model. The flowrate of the working fluid is determined as 330CMH which is equivalent to 70 percent of maximum capacity of HVAC system. The high velocity regions are formed around 4 each panel vent. Because of the non-symmetrically located exhaust, non-uniform flow and partial backflow near the door trim is observed. Streaklines start from each panel vent show the flow pattern of the airflow in the passenger's compartment very well.

플라즈마 디스플레이 보호막으로 사용되는 마그네슘 산화막(MgO)의 내식각 특성 (The characteristics of anti-erosion for MgO protecting layer in plasma display panel)

  • 최훈영;이석현
    • 한국전기전자재료학회논문지
    • /
    • 제13권2호
    • /
    • pp.163-169
    • /
    • 2000
  • In this paper, we showed the erosion characteristic of MgO protector layer releated to lifetime of plasma display panel(PDP). We observed MgO erosion characteristic as a functions of deposition conditions, pressure and distance between electrodes. In RIE condition of Xe gas, the lowest erosion rate appears in the conditions of no heating bias voltage -30V and pressure 5mtorr. In general, as deposition rate increases, erosion rate decreases. In real panel, when the gap distance between electrodes is narrow and the pressure is low, the heavy plasma damage appears. Also, the surfaces between electrodes and on the bus electrode are extremely damaged.

  • PDF