• Title/Summary/Keyword: panel evaluation

Search Result 766, Processing Time 0.029 seconds

Evaluation on the Formability of Corrugated Membrane panels of a LNG Storage Tank (LNG 저장탱크용 멤브레인의 성형성 평가)

  • 박구환;변상규;김성원;강범수
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.10a
    • /
    • pp.98-101
    • /
    • 1997
  • Membrane panels for LNG(Liquid Natural Gas) tank are formed to corrugared ones by press forming. The environment of LNG tank is so severe that the service temperature is -162$^{\circ}C$ and the room temperature is 20$^{\circ}C$. The thermal deformation derived by the severe temperature change is absorbed by the corrugations of the membrane panels. In this paper the formability of stainless steel membrane panel is examined by the finite element analysis. Two corrugated shapes are suggested, and analyzed to obtain a sound absorption performance of the thermal distortion. Also the design considers forming characteristics and economy of production.

  • PDF

Explosion Proof of Fiber Reinforced Cement Composite Panel subjected to Contact Explosion (접촉폭발에 의한 섬유보강 시멘트 복합체의 방폭성능)

  • Kim, Yun-Hwan;Kim, Gyu-Yong;Kim, Hong-Seop;Lee, Bo-Kyeong;Lee, Sang-Gyu;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.128-129
    • /
    • 2016
  • This paper evaluates experimentally the explosion proof of fiber reinforced cement composite(FRCC) panels with various fibers of 2 % volume fraction subjected to contact explosions using an emulsion explosive. As a results, the proportion of the total damage in FRCC panels is not biased scabbing on the rear side with contrast to plain panels, which means that the local damage of FRCC panels was significantly controlled. The experimental results presented useful information for prediction of limited thickness on the local damage subjected to contact explosions through comparison with existing damage evaluation prediction equations.

  • PDF

An Experimental Study on Thermal and Environmental Characteristics of Various Heating Systems in the Residential House (주거용 건물의 난방 방식별 열적성능 및 실내환경 특성 평가를 위한 실험적 연구)

  • Lee, Choong-Kook;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.121-128
    • /
    • 2005
  • This is about experimental comparison study between convective heating and radiation heating system to use the design criteria for residential house. Experiment was done in EC(environment chamber) under simultaneous outdoor condition for 4 kinds of heating system such as CRHP(Ceiling Radiant Heating Panel), BEHC( Bottom Electric Heating Coil Mat), EFCU( Electric Fan Coil Unit) and CEHU( Convective Electric Heating Unit). Result show that CRHP ,which is radiation heating system, can consume more 23% energy than convective heating system when it is operated by dry bulb temperature but can save 1 ${\sim}$ 10% when operated by glove temperature and 27% when operated by MRT.

  • PDF

An Evaluation of Seismicity Parameters in the Korean Peninsula Using EQHAZARD (EQHAZARD를 이용한 한반도 지진 파라미터 추정)

  • 연관희
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.31-38
    • /
    • 1998
  • In this study, statistical analyses implemented in the EPRI EQHAZARD programs were employed to estimate the sismicity parameters in the Korean peninsula based upon an combined Korean earthquake catalog. The combined earthquake catalog was prepared by performing earthquake clustering analysis on the collected earthquake catalogs provided by experts of the seismic panel during the PSA for Yonggwang Units 1 & 2. The duplicate earthquake events and secondary events in earthquake clusters have been successfully screened. The resultant earthquake catalog was analyzed to quantitatively assess the incompleteness of the earthquake catalog for specified earthquake magnitudes and time periods. The result shows that the earthquake catalog of the Korean peninsula is complete for the times periods of 1392 ~ 1750 and 1905 ~ 1989 (AD) and earthquake magnitude above 4.5. The PSHA methodology of EQHAZARD features the estimation of inhomogeneous a-and b-values within a seismic source. This study shows various results of a-and b-value is well constrained lying between o.6 and 1.0. Also the confidence of estimated a-and b-value for a specifed location was assessed by quantifing the uncertainty of these parameters using bootstrap simulation.

  • PDF

Some Thoughts on LCCO2 of the Railway Track System (철도 궤도시스템의 LCCO2에 관한 소고)

  • Minnu, Tian;Lee, Woo-Chul;Choi, Sang-Hyun;Lim, Nam-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.548-551
    • /
    • 2009
  • The report of the intergovernment panel on climate change(IPCC) concluded that the global warning due to Green-house Gas(GHGs) will be accelerated in the 21th century. The railroad construction sector consumes a great deal of natural resources and energy in construction. maintenance, and demolition stage. In order to establish and perform reducing plan of GHGs of railway track system for effective corresponding the Climate Change Agreement, the evaluation method of the lifecycle CO2 emission if needed. In this research, it was investigates that the research trend for the LCCO2 and the method to estimate the lifecycle carbon dioxide emission amount of the railway track system as quantitative.

  • PDF

Forming Limit Diagram of Laser Welded Blank and Its Application to Forming Analysis of Stamping Dies (레이저 용접 합체박판의 성형한계도와 스탬핑 금형 성형해석에 적용)

  • 금영탁;구본영;박승우;유석종;이경남
    • Transactions of Materials Processing
    • /
    • v.9 no.1
    • /
    • pp.3-9
    • /
    • 2000
  • The new FLD of the laser welded blank, which includes FLCs of welded zone and base metals, is introduced. For the forming limits of welded zone, the hemispherical dome punch tests were performed with various widths of asymmetric specimen. The FLC0 as well as the dome height at fracture associated with various specimen widths in the same and different thickness combinations were found to see the formability depending on thickness combinations. In order to show the application of the new FLD, the measured strains of squared cup drawing and simulated strains of door inner panel stamping were compared with those of FLCs. The successful prediction of fracture in the applications reveals that the forming limits of welded zone and base metals should be separately found for more accurate evaluation of the formability and workability of the laser welded blank.

  • PDF

Improvement and Evaluation of Earthquake Resistant Retrofit Techiques for Remodeling of Structural Performance in Existing Reinforced Concrete Frames (기존 철근콘크리트 골조의 리모델링을 위한 내진보강 기술의 구조성능 평가 및 개선)

  • Ha, Gee-Joo;Shin, Jong-Hack;Lee, Sang-Mog
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.175-182
    • /
    • 2001
  • Five reinforced concrete frames were constructed and tested to study the structural performance of retrofitting effect reinforced concrete frame during and load revesals simultaneously. All specimens were modeling in one-third scale size. Experimental research was carried out to develop and evaluate the hysteretic behavior of reinforced concrete frame designed by high performance techniques, using carbon fiber plate, ALC panel, steel plate system with or without stiffener. Experimental programs wore carried to evaluate the structural performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. Specimens(RFCP, RFAR, RFSR, RFSR-S), designed by the improvement of earthquake-resistant performance, were attained more load-carrying capacity, energy dissipation capacity, and stable hysteretic behavior.

  • PDF

Fabrication and Evaluation of Composite Panel with L-shaped Stiffeners (L-형 보강재를 가진 복합재 패널의 제작과 평가)

  • Yun, Jong-Hwa;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.26 no.2
    • /
    • pp.99-104
    • /
    • 2013
  • The design of composite joint is important research area because they are often the weakest areas in composite structures. In this paper, the specimens with three paste thickness (0.2 mm, 0.6 mm, 4 mm) were manufactured in secondary bonding method and tested in two different loading direction condition. Also, the failure index of the L-type stiffener was calculated by the finite element method and compared with experimental results.

High Optical Performance of 7" Mini-monitor Based on 2D-3D Convertible Autostereoscopic Display

  • Kim, Sun-Kyung;Park, Sang-Hyun;Kim, You-Jin;Min, Kwan-Sik;Park, Seo-Kyu;Jhun, Chul-Gyu;Kwon, Soon-Bum
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1367-1370
    • /
    • 2009
  • We have developed a 2D-3D convertible 7" autostereoscopic mini-monitor with high 3D quality, in which the parallax barrier LCD is attached on the TFTLCD. The excellent optical performance was achieved by design of the ghost free barrier and precise assembly between the barrier layer and the TFT-LCD panel. Our design principle and fabrication technology suppressed 3D cross-talk and improved viewing angle. In this paper, the design and fabrication process of the 3D mini-monitor are described. The evaluation for the 3D performance is also discussed.

  • PDF

Secondary Electron Emission Characteristics of Functional Layer in AC-PDP

  • Son, Chang-Gil;Han, Young-Gyu;Kim, Yong-Hee;Cho, Byeong-Seong;Hong, Young-Jun;Song, Ki-Baek;Bae, Young-Joo;Kim, In-Tae;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.736-739
    • /
    • 2009
  • We have studied that the secondary electron emission characteristics of functional layers which have different kinds of MgO sub-micrometer size powder in AC-PDP. We used cathodoluminescence(CL) and gamma focused ion beam (${\gamma}$-FIB) system for measurement of secondary electron emission characteristics. Also we made 6 inch test panel which applied functional layers for evaluation of discharge characteristics.

  • PDF