• Title/Summary/Keyword: panel evaluation

Search Result 762, Processing Time 0.023 seconds

Elastic-plastic Finite Element Analysis of Drawbead Forming for Evaluation of Equivalent Boundary Conditions in Sheet Metal Forming - Part II : Application to the front Door Panel Forming Process (박판 성형공정에서의 등가 경계조건 계산을 위한 드로우비드 성형의 탄소성 유한요소 해석 - Part II : 프런트 도어 판넬 성형공정에서의 적용)

  • Park, J.S.;Kim, S.H.;Huh, H.
    • Transactions of Materials Processing
    • /
    • v.11 no.6
    • /
    • pp.513-518
    • /
    • 2002
  • The equivalent boundary conditions have been applied to the front door panel forming process, in order to demonstrate its reliability and validity. The elongation in the bead forming process is applied to the binder wrap process as the equivalent displacement boundary condition and the restraining force in the drawing process is applied to stamping process as the equivalent force boundary condition. The result calculated with the equivalent boundary conditions shows closer coincidence with the experimental result than simulation with different boundary conditions. The numerical result fully demonstrates that drawbead forming simulation for calculation of equivalent boundary conditions is necessary and effective.

Flow Analysis and Evaluation of Injection-Molded Front Panel (백라이트 패널(back light panel)의 유동해석 및 평가)

  • 강성남;허용정
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.11a
    • /
    • pp.144-146
    • /
    • 2001
  • The synthesis of injection-molded parts has been done empirically, since it requires profound knowledge about injection molding which is not available to designers through current CAD systems. Appropriate U3 programs for mold design analysis to an existing geometric modeler is used to provide designers, at the initial stage, with comprehensive process knowledge for synthesis, performance analysis and feature-based geometric modeling.

Development of and Evaluation Tool for the Quality of Patient Care in Musculo-skeletal Disorder (${\cdot}$ 골격장애 환자의 간호질 평가 도구 개발)

  • Choi, Soon-Ook;Kim, Moon-Sil
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.1 no.2
    • /
    • pp.338-348
    • /
    • 1995
  • We need to continuously evaluate for nursing quality and the outcome to reflect nursing, to repair and improve of nursing. The first problem for nursing quality improvement is development of evaluation tool for the quality of nursing care. We need a system for quality assurance evaluation that is, development and framework of evaluation tool for nursing care quality. The purpose of this study was attempted to develop an evaluation tool for the quality of nursing care in musculoskeletal disorder patients. The approach method of nursing quality for the development of the tool in this study was process evaluation framework. The study were devided dvelopment process and reliability, validity verification process. The subjects of development process of this tool are three nursing export groups, and the subject of reliability, validity verification process are 20 samples of two university hospital in seoul, who were within discharge 3 months after admission treatment in musculo-skeletal disorder. Data for this study was collected from March 10 to April 13, 1995. The development process of the tool were as follows : 1. Make preliminary list of the tool by focal group were constituted 12 clinical nurses. 2. Modify and add preliminary list by 4 nursing expert panel. 3. Calculate content validity of the tool by 25 nursing expert panel of judge. 4. Verify reliability and validity of the tool. 5. Finalize an evaluation tool for the quality of the nursing care in musculo-skeletal disorder. The results of this study were as follows : 1) Development an evaluation tool for the quality of nursing care in musculo-skeletal disorder. (1) The evalution tool of this study was developed 5 standards, 33 criterias and 133 indicators. (2) 5 standards were divided according to Nursing Process. from standard 1 to standard 5, involved criterias were each 6(18%), 3(9%), 3(9%), 15(46%), 6(18%). 2) Verify reliability and validity of the tool. (1) Score of adequate degree for content validity of 33 criterias and 133 indicators were every average 2.82. (2) Inter-rater reliabilities(consentaneity score) of the tool by pearson correlation coefficient between three raters were : r=.7506, r=.8934, r=.6695. and Inter-rater reliabilities by single-facet crossed design were : r=.7464. (3) The alpha coefficient relating to internal consistency was .8524 over all 30 items of 33 criterias of developed tool. (4) Score of the quality of nursing care following to generaal characteristics of this study subjects were stastically significant differences according to educational level (F=2.93, p=.029)and diagnosing classification (F=2.50, p=.042). Through this study, I'm sure that the developed tool for the quality of patient care in musculo-skeletal disorder will show the way of more improvement of the quality of nursing care and effective nursing interventions.

  • PDF

The Effect of Having Usual Source of Care on the Choice among Different Types of Medical Facilities (상용치료원 보유가 의료기관 종별 선택에 미치는 영향: 대형병원 환자집중현상 완화방안을 중심으로)

  • Kim, Doo Ri
    • Health Policy and Management
    • /
    • v.26 no.3
    • /
    • pp.195-206
    • /
    • 2016
  • Background: Concentration of patients to large hospitals is serious problem in Korea. The purpose of this paper is to propose appropriate policy direction to relieve concentration of patients to large hospitals. It is focused on evaluation of the possibility of family doctor system as a policy alternative to relieve concentration of patients to large hospital by empirically analyzing the effect of usual source of care (USC) on large hospitals medical care use. Methods: Korea Health Panel conducted 2009, 2012, 2013 by KIHASA (Korea Institute for Health and Social Affairs) and NHIS (National Health Insurance Service) was used for analysis. For dependent variables, first, the ratio of the amount of using large hospital to total amount of using medical care, and second, the amount of using large hospital are estimated. Independent variables are having an USC and type of USC. Panel analysis was done with above variables. Results: Main results are as follows. First, having an USC increases using large hospital. Second, having a domestic clinic type USC decreases using large hospital and ratio of using large hospital. Third, the effect of domestic clinic type USC is greater in older group, less income group, worse health status group, not having private insurance group, and having chronic disease group. Conclusion: These results show that family doctor program can be a policy alternative to relieve concentration of patients to large hospital. Nonetheless, primary care system in Korea is unsatisfied. It is recommended to reinforce primary care system and family doctor system to relieve concentration of patients to large hospitals.

A Study on the Evaluation of Mechanical Characteristics for Tailor Welded Blank Panel (TWB 판넬의 기계적특성 평가에 관한 연구)

  • Chun, Chang-Hwan;Han, Chang-Suk
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.4
    • /
    • pp.183-190
    • /
    • 2010
  • There are many methods to reduce the weight and the cost of the automobile body, among them, Tailor Welded Blank (TWB) is new welding method applied to body structure. It is necessary to evaluate mechanical properties of TWB structures or sheets for the application to automobile body parts. In this study, the stiffness of T-type and L-type joint structures, composite of TWB panel, which simplified two portions of side structure in automobile body were investigated. Additionally, the fatigue properties of TWB panels were obtained. Two types of welding technologies, laser and mash seam welding, were used to join mild panels with different thickness. This results are compared with conventional structures. The results are as follows: 1) The stiffness of joint structures, composite of TWB panel, is approximately 17% higher than that of conventional ones. 2) The location of welding line in TWB had a effect on the in plane bending stiffness, but not on the out of plane bending stiffness. 3) In terms of welding technology type, the mash seam welding show higher stiffness than the laser welding for in plane bending stiffness. But minimal differences in both types are revealed for out of plane bending stiffness. 4) The fatigue strength, composite of TWB panel, is lower than that of base steel. It is thought that defects in the welding zone had the action of notch in the fatigue test.

Experimental and numerical investigation on in-plane behaviour of hollow concrete block masonry panels

  • Murthy, A. Rama Chandra;Ganapathi, S. Chitra;Iyer, Nagesh R.;Lakshmanan, N.;Bhagavan, N.G.
    • Computers and Concrete
    • /
    • v.10 no.1
    • /
    • pp.1-18
    • /
    • 2012
  • This paper presents the details of studies conducted on hollow concrete block masonry (HCBM) units and wall panels. This study includes, compressive strength of unit block, ungrouted and grouted HCB prisms, flexural strength evaluation, testing of HCBM panels with and without opening. Non-linear finite element (FE) analysis of HCBM panels with and without opening has been carried out by simulating the actual test conditions. Constant vertical load is applied on the top of the wall panel and then lateral load is applied in incremental manner. The in-plane deformation is recorded under each incremental lateral load. Displacement ductility factors and response reduction factors have been evaluated based on experimental results. From the study, it is observed that fully grouted and partially reinforced HCBM panel without opening performed well compared to other types of wall panels in lateral load resistance and displacement ductility. In all the wall panels, shear cracks originated at loading point and moved towards the compression toe of the wall. The force reduction factor of a wall panel with opening is much less when compared with fully reinforced wall panel with no opening. The displacement values obtained by non-linear FE analysis are found to be in good agreement with the corresponding experimental values. The influence of mortar joint has been included in the stress-strain behaviour as a monolith with HCBM and not considered separately. The derived response reduction factors will be useful for the design of reinforced HCBM wall panels subjected to lateral forces generated due to earthquakes.

The Study of Long-Term Performance Evaluation of Vacuum Insulation Panel(VIP) with Accelerated Aging Test (가속노화 시험을 통한 진공단열패널(VIP)의 장기성능 평가 연구)

  • Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.35-47
    • /
    • 2017
  • Energy efficiency solutions are being pursued as a sustainable approach to reducing energy consumption and related gas emissions across various sectors of the economy. Vacuum Insulation Panel (VIP) is an energy efficient advanced insulation system that facilitates slim but high-performance insulation, based on a porous core material evacuated and encapsulated in a barrier envelope. Although VIP has been applied in buildings for over a decade, it wasn't until recently that efforts have been initiated to propose and adopt a global standard on characterization and testing of VIP. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time; more so in building applications. In this paper, the aging of commercially available VIP was investigated experimentally; thermal conductivity was tested in accordance with ISO 8302 standard (guarded hot box method) and long-term durability was estimated based on a non-linear pressure-humidity dependent equation based on study of IEA/ECBCS Annex 39, with the aim of assessing durability of VIP for use in buildings. The center-of-panel thermal conductivity after 25 years based on initial 90% fractile with a confidence level of 90 % for the thermal conductivity (${\lambda}90/90$) ranged from 0.00726-0.00814 (W/m K) for silica core VIP. Significant differences between manufacturer-provided data and measurements of thermal conductivity and internal pressure were observed.

Integrity Evaluation of Railway Bogie Using Infrared Thermography Technique (적외선 열화상 기술을 이용한 철도차량 대차 건전성 평가)

  • Kim, Jeong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.144-149
    • /
    • 2011
  • The lock-in thermography was employed to evaluate the integrity of railway bogies. Prior to the actual application on railway bogies, in order to assess the detectability of known flaws, the calibration reference panel was prepared with various dimensions of artificial flaws. The panel was composed of structural steel, which was the same material with actual bogies. Through lock-in thermography evaluation, the optimal frequency of heat source was determined for the best flaw detection. Based on the defects information, the actual defect assessments on railway bogie were conducted with different types of railway bogies, which were used for the current operation. In summary, the defect assessment results with thermography method showed a good agreement as compared with the conventional inspection techniques. Moreover, it was found that the novel infrared thermography technique could be an effective way for the inspection and the detection of surface defects on bogies since the infrared thermography method provided rapid and non-contact mode for the investigation of railway bogies.

Effects of Cooking End-point Temperature and Muscle Part on Sensory 'Hardness' and 'Chewiness' Assessed Using Scales Presented in ISO11036:1994

  • Sasaki, Keisuke;Motoyama, Michiyo;Narita, Takumi;Chikuni, Koichi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.10
    • /
    • pp.1490-1495
    • /
    • 2013
  • Texture and 'tenderness' in particular, is an important sensory characteristic for consumers' satisfaction of beef. Objective and detailed sensory measurements of beef texture have been needed for the evaluation and management of beef quality. This study aimed to apply the sensory scales defined in ISO11036:1994 to evaluate the texture of beef. Longissimus and Semitendinosus muscles of three Holstein steers cooked to end-point temperatures of $60^{\circ}C$ and $72^{\circ}C$ were subjected to sensory analyses by a sensory panel with expertise regarding the ISO11036 scales. For the sensory analysis, standard scales of 'chewiness' (9-points) and 'hardness' (7-points) were presented to the sensory panel with reference materials defined in ISO11036. As a result, both 'chewiness' and 'hardness' assessed according to the ISO11036 scales increased by increasing the cooking end-point temperature, and were different between Longissimus and Semitendinosus muscles. The sensory results were in good agreement with instrumental texture measurements. However, both texture ratings in this study were in a narrower range than the full ISO scales. For beef texture, ISO11036 scales for 'chewiness' and 'hardness' are useful for basic studies, but some alterations are needed for practical evaluation of muscle foods.

Analysis of Characteristics and User's Evaluation for Lightweight Panel in Apartment (공동주택 경량칸막이 벽체구성재 분류별 사용자 평가 및 특성 분석)

  • Park, Hyeon-Ku
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.1
    • /
    • pp.181-191
    • /
    • 2010
  • Lightweight panels are currently used in many ways, such as inner walls of the skyscrapers and residential buildings in Korea. Moreover there has been an increasing of interest in developing construction method and quality improvement as many buildings became higher, because there are more advantages like constructability, finishability, and economic efficiency, etc. than previous heavy weight concrete wall. It is necessary to analyze the characteristics and evaluate the performance of lightweight panels when selecting proper methods and materials to building characteristics and builder's demand. However, there doesn't exist systematic data with a classification of lightweight panels' type and performance. The purpose of this study is to classify domestic lightweight panels by both type of exterior board and construction method, and also to evaluate each performance by surveying user's opinion.