• 제목/요약/키워드: panel evaluation

검색결과 760건 처리시간 0.026초

휴대용 IT 기기의 디스플레이 내충격 설계를 위한 손상평가 연구 (Study on The Shock Damage Evaluation of TFT-LCD module for Mobile IT Devices)

  • 김병선;이덕진;구자춘;최재붕;김영진;주영비
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.489-493
    • /
    • 2005
  • TFT-LCD(Thin Film Transistor Liquid Crystal Display) module is representative commercial product of FPD(Flat Panel Display). Thickness of TFT-LCD module is very thin. It is adopted for major display unit for IT devices such as Cellular Phone, Camcorder, Digital camera and etc. Due to the harsh user environment of mobile IT devices, it requires complicated structure and tight assembly. And user requirements for the mechanical functionalities of TFT-LCD module become more strict. However, TFT-LCD module is normally weak to high level transient mechanical shock. Since it uses thin crystallized panel. Therefore, anti-shock performance is classified as one of the most important design specifications. Traditionally, the product reliability against mechanical shock is confirmed by empirical method in the design-prototype-drop/impact testredesign paradigm. The method is time-consuming and expensive process. It lacks scientific insight and quantitative evaluation. In this article, a systematic design evaluation of TFT-LCD module for mobile IT devices is presented with combinations of FEA and testing to support the optimal shock proof display design procedure.

  • PDF

델파이 기법을 이용한 정성적 공법 선정 요인의 정량적 평가 분석 (Quantified Evaluation on the Qualitative Criteria for the Selection of Appropriate Concrete Slab Form-works for Residential Buildings)

  • 이경석;이태희;신영근;김태형;한승우
    • 한국건축시공학회지
    • /
    • 제11권2호
    • /
    • pp.136-144
    • /
    • 2011
  • 콘크리트 구조물의 골조공사에서의 주요 공정 중 하나인 거푸집 공사는 전체 건축공사의 공사기간 및 공사비 측면에서 상당 부분을 차지하고 있다. 하지만 공사현장의 조건을 고려한 거푸집의 적정시스템 선정은 현재까지 현장실무자의 경험에만 의존하고 있는 실정이다. 본 논문에서는 거푸집 공법 선정 요인에 대한 정량화된 분석을 바탕으로 슬래브 거푸집 중 신공법과 기존 공법을 선정하여 각 공법의 성능을 정량화된 분석데이터를 바탕으로 평가했다. 이를 통하여 각 공법들의 정성적 항목에 대한 정량화된 평가점수를 산출하여 슬래브 거푸집의 현장 적용성에 대한 평가 방안을 제시하였다. 따라서 본 논문에서 사용된 델파이 기법의 방법론은 다른 공법들의 선정, 평가에도 사용될 것이라 사료된다.

가스크로마토그래피에 의한 식물성 기름의 향미품질의 분석 (Analyses of Flavor Qualities of Vegetable Oils by Gas Chromatography)

  • 윤석후;김종군;민병선
    • 한국식품과학회지
    • /
    • 제17권5호
    • /
    • pp.355-360
    • /
    • 1985
  • 콩기름, 경화콩기름 및 옥수수기름을 형광하에서 산화시켜. 향미품질을 관능검사및 가스크로마토 그라피(GC)로 분석하였다. 관능검사의 경우, 10점 Hedonic scale을 사용하여 8개의 각기 다른 연구소에서 시행하였는데, 총 평가원의 수는 95명이었다. 관능검사에 의한 기름의 향미 품질값과 GC에 의한 계산된 향미품질 값 사이치 상관계수는 0.10$\sim$0.99사이에 나타났으나. 대부분의 경우 상관계수 0.9이상의 높은 상관관계를 보였다. 총평가원의 관능검사에 의한 향미품질값과 GC에 의한 향미품질값의 상관계수는 콩기름 0.96, 경화콩기름 0.97 및 옥수수기름 0.97이었다 가스크로마토그래피에 의한 향미품질값의 계산은 2.4-decadienal 이성체의 합계를 근거로 하였다. 이 상관관계 연구는, 식용유의 향미성분에 의한 품질검사가 GC분석, 관능검사및 통계처리가 적합할 경우, 실제 공정에 필요한, 유용한 방법으로 쓰일 수 있음을 시사하였다.

  • PDF

비정형 건축곡면 패널분할 최적화를 위한 평가지표에 관한 연구 (A Study on Evaluation Index of the Panelizing Optimization for Architectural Freeform Surfaces)

  • 유정원
    • 한국산학기술학회논문지
    • /
    • 제14권7호
    • /
    • pp.3528-3537
    • /
    • 2013
  • 비정형 건축곡면의 패널분할 최적화 정도를 평가하기 위한 여러 가지 최적화 평가기법들이 개발되어 적용되고 있으나 이러한 평가기법과 평가지표들은 독립성, 보편성을 확보하고 있지 못하다. 그러므로 본 연구에서는 비정형곡면 패널분할 최적화 평가기법 및 평가지표에 관한 사례 및 선행연구 고찰을 통한 독립성 및 보편성이 확보되는 비정형 곡면 패널분할 최적화의 정량적 평가를 위한 평가항목 추출과 평가지표의 제안이 이루어진다. 제안된 세 가지 패널분할 최적화 평가항목은 원형 충실도, 생산 용이성, 연속성이며, 원형 충실도를 위한 평가지표로는 곡면 일치, 생산 용이성을 위한 평가지표로는 평면성, 평면 패널 비율, 연속성을 위한 평가지표로는 접선 연속성, 사이 간격이 제안되었으며 그 산출방법이 함께 제안되었다.

단열패널 종류별 이격거리에 따른 화재감식 평가 (Evaluation of Fire Investigation as the Separation Distances for Several Types of Insulation Panels)

  • 김정훈;김다슬
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.403-412
    • /
    • 2021
  • 단열패널(표면재, 심재, 마감재로 구성되어 있으며 경량성, 저가성 및 시공성 등의 장점)의 화재난연성과 적용건축물 강화에도 불구하고, 화재발생 건수와 피해 영향은 지속적으로 증가하고 있다. 본 연구에서는 단열패널 종류별이격거리에 따른 열영향(온도변화, 점화가능성, 내·외부 연소흔, 심재의 형상 변화)을 평가하고자 국내에서 사용빈도가 높은 EPS 패널, 글라스울 패널, 석고보드 패널의 3종을 선택하였다. 패널에는 지면으로부터 수직(30 cm, 90 cm, 150 cm)으로 온도센서를 설치하였고, 적층한 각목을 화원으로 패널로부터 각각 0 cm, 25 cm, 50 cm 이격거리를 변화시키면서 점화시켰다. 실험 결과, 최고온도는 EPS 패널에서 349 ℃를 나타내었고, 패널의 내·외부 형상변화는 이격거리 25 cm를 임계점으로 하부에서 중부까지 높이로 국한되었다. 또한 연소흔은 평균 500 s 이후에서 나타났고, 화재강도가 큰 EPS 패널에서는 광폭의 U자형 패턴, 글라스울과 석고보드 패널에서는 중폭 또는 협폭의 V자형 패널을 형성하였다. 도출된 정보를 통해 단열 패널로 구성된 건축물로부터 화재위험성 평가와 화재감식의 검증에 필요한 유용한 정보를 제공하고자 한다.

청소년의 자아존중감과 환경특성이 삶의 만족도에 미치는 영향 : 긍정적 자아평가와 부정적 자아평가의 조절효과 (An Influence of Adolescent's Self-Esteem and Environmental Characteristics on Life Satisfaction : Moderating Effect of Positive Self-Evaluation and Negative Self-Evaluation)

  • 이종석;정득
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6595-6603
    • /
    • 2015
  • 본 연구는 한국청소년정책연구원에서 제공하는 한국아동 청소년 패널조사(Korean Children and Youth Panel Survey) 3차년도(2012) 자료를 이용하여, 중학교 3학년 2,040명의 자아존중감과 환경변수들이 삶의 만족도에 미치는 영향을 분석하였다. 개인특성으로서 자아존중감을 긍정적 자아와 부정적 자아에 대한 평가라는 별개의 두 차원으로 구분하였을 때, 환경특성이 삶의 만족도에 미치는 영향에 대한 두 평가수준의 조절효과가 존재하였다. 자아존중감을 두 평가차원의 수준에 따라 4개의 집단으로 구분하여 환경특성(부모, 친구, 학교)이 삶의 만족도에 미치는 영향에 대한 경로분석을 수행한 결과, 긍정적 자아에 대한 평가가 높은 집단들은 그렇지 않은 집단에 비해 더 많은 경로에서 유기적인 관련성을 보였다. 또한 부정적 자아에 대한 평가가 높은 집단의 경우, 긍정적 자아에 대한 평가가 높을 때 부정적 자아가 삶의 만족도에 미치는 음(-)의 영향을 상쇄하였다. 이러한 결과는 청소년의 자아존중감을 단일 차원의 개념이 아닌, 긍정적 자아와 부정적 자아에 대한 평가라는 두 차원으로 구분하여 분석할 필요성을 제시한다. 부정적 자아에 대한 낮은 평가가 반드시 긍정적 자아에 대한 높은 평가를 의미하는 것은 아니기 때문에, 청소년 심리 상담에 있어 부정적 자아 형성의 문제 해결과 함께 긍정적 자아 형성을 위한 방안이 모색되어야 한다는 것을 시사한다.

하이브리드 샌드위치 복합재 초저상버스 구조물의 파손 평가 연구 (A Study on Failure Evaluation of Korean Low Floor Bus Structures Made of Hybrid Sandwich Composite)

  • 이재열;신광복;이상진
    • 한국자동차공학회논문집
    • /
    • 제15권6호
    • /
    • pp.50-61
    • /
    • 2007
  • The structural stiffness, strength and stability on the bodyshell and floor structures of the Korean Low Floor Bus composed of laminate, sandwich panels and metal reinforced frame were evaluated. The laminate composite panel and facesheet of sandwich panel were made of WR580/NF4000 glass fabric/epoxy laminate, while aluminum honeycomb or balsa was applied to the core materials of the sandwich panel. A finite element analysis was used to verify the basic design requirements of the bodyshell and the floor structure. The use of aluminum reinforced frame and honeycomb core was beneficial for weight saving and structural performance. The symmetry of the outer and inner facesheet thickness of sandwich panels did not affect the structural integrity. The structural strength of the panels was evaluated using Von-Mises criterion for metal structures and total laminate approach criterion for composite structures. All stress component of the bodyshell and floor structures were safely located below the failure stresses. The total laminate approach is recommended to predict the failure of hybrid sandwich composite structures at the stage of the basic design.

Experimental and analytical evaluation of a low-cost seismic retrofitting method for masonry-infilled non-ductile RC frames

  • Srechai, Jarun;Leelataviwat, Sutat;Wongkaew, Arnon;Lukkunaprasit, Panitan
    • Earthquakes and Structures
    • /
    • 제12권6호
    • /
    • pp.699-712
    • /
    • 2017
  • This study evaluates the effectiveness of a newly developed retrofitting scheme for masonry-infilled non-ductile RC frames experimentally and by numerical simulation. The technique focuses on modifying the load path and yield mechanism of the infilled frame to enhance the ductility. A vertical gap between the column and the infill panel was strategically introduced so that no shear force is directly transferred to the column. Steel brackets and small vertical steel members were then provided to transfer the interactive forces between the RC frame and the masonry panel. Wire meshes and high-strength mortar were provided in areas with high stress concentration and in the panel to further reduce damage. Cyclic load tests on a large-scale specimen of a single-bay, single-story, masonry-infilled RC frame were carried out. Based on those tests, the retrofitting scheme provided significant improvement, especially in terms of ductility enhancement. All retrofitted specimens clearly exhibited much better performances than those stipulated in building standards for masonry-infilled structures. A macro-scale computer model based on a diagonal-strut concept was also developed for predicting the global behavior of the retrofitted masonry-infilled frames. This proposed model was effectively used to evaluate the global responses of the test specimens with acceptable accuracy, especially in terms of strength, stiffness and damage condition.

패널자료를 이용한 사업의 효과성 분석 : 산업융합원천기술개발사업을 중심으로 (Evaluation of Program Effectiveness Using Panel Data : Focused on Fusion Technology Program)

  • 김흥규;강원진;배진희
    • 산업경영시스템학회지
    • /
    • 제37권3호
    • /
    • pp.122-128
    • /
    • 2014
  • When evaluating effectiveness of a program, there is a tendency to simply compare the performances of the treated before and after the program or to compare the differences in the performances of the treated and the untreated before-after the program. However, these ways of evaluating effectiveness have problems because they can't account for environmental changes affecting the treated and/or effects coming from the differences between the treated and the untreated. Therefore, in this paper, panel data analysis (fixed effects model) is suggested as a means to overcome these problems and is utilized to evaluate the effectiveness of fusion technology program conducted by Ministry of Trade, Industry and Energy, Korea. As a result, it turns out that the program has definitely positive impacts on the beneficiary in terms of sales, R&D expenditure, and employment.

태양에너지를 이용한 열-전기 동시생산을 위한 PV-Solarwall 단위모듈 성능평가 연구 (The Performance Evaluation Study of PV-Solarwall Unit Module Solar Thermal-Electric Energy)

  • 김용환;조일식;이의준;현명택;강은철
    • 한국태양에너지학회 논문집
    • /
    • 제25권3호
    • /
    • pp.69-75
    • /
    • 2005
  • The PV-Solarwall system has been introduced as a promising alternative to harness solar energy for both heating applications and electricity generation simultaneously. The system comprises a PV solar panel(for electricity generation). In addition, the solarwall incorporates a fan strategically located behind the PV panel to bring the warm and fresh air from the solarwall into the room. Because of its location and convective cooling principle, the fan also serves to reduce the operating temperature of the PV panel thereby increasing its efficiency. So this PV-Solarwall system holds much promise for saving heating and electricity costs compared with a PV system without solarwall. In particular, by controlling the tilt angle of the entire PV-Solarwall system between $0^{\circ}$(horizontal) and $90^{\circ}$(vertical), the performance of the system can be further evaluated. It is expected that the range of tilt angle PV-Solarwall between $40^{\circ}$ and $50^{\circ}$ will improve the output of the system.