• Title/Summary/Keyword: panel evaluation

Search Result 760, Processing Time 0.028 seconds

Formability of Aluminum 5182-Polypropylene Sandwich Panel for Automotive Application (자동차용 알루미늄 5185-폴리프로필렌 샌드위치 판재의 성형성)

  • Kim, Kee-Joo;Jeong, Hyo-Tae;Sohn, Il-Seon;Kim, Cheol-Woong;Kim, Joong-Bae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.175-181
    • /
    • 2007
  • The objective of this study was to develop formability evaluation techniques in order to apply aluminum sandwich panel for automotive body parts. For this purpose, newly adopting formability evaluation (using limit dome height and plane strain test) was carried out in order to secure the fundamental data for the measurement of sheet metal forming and the establishment of optimum forming conditions of the aluminum sandwich panel. The results showed that there were good agreements between the old formability evaluation method and the new method which was more simplified than that of old one. From the results of these formability evaluation, the formability of sandwich panel was higher than that of aluminum alloy sheet alone which was the skin component for the sandwich panel. Also, it was found that sandwich panel could reduce the weight and could have the same flexural rigidity simultaneously when it was compared to the automotive steel sheet.

High vacuum packaging and vacuum evaluation for field emission display

  • Jung, S.J.;Woo, K.J.;Lee, N.Y.;Ahn, S.;Moon, G.J.;Kim, K.S.;Kim, M.S.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.3 no.1
    • /
    • pp.95-97
    • /
    • 1999
  • A 3.12" FED panel was packaged successfully using the anode plate on which phosphors and black matrix were coated and cathode plate containing emitter arrays. The vacuum level of the panel was investigated during panel evacuation, tip-off and getter activation process. The packaged panel exhibited vacuum level below 2${\times}$10-6 Torr. Similar experiments were carried out for 10" panel made of bare plates. In addition, the vacuum level of two panels was compared continuously after tip off process; one with the getter and the other without it.

  • PDF

Toughness Evaluation of Steel Fiber Reinforced Concrete to Spiecimen Types (시편형상에 따른 강섬유보강 콘크리트의 휨인성평가방법)

  • 류종현;김진철;한승환;이상돈;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.341-344
    • /
    • 2001
  • Fiber reinforced shotcrete(FRS) is widely used in tunnel linings, which strengthen the rock surface and reduce the loosening of the rock strata. The advantages of FRS in tunnel linings are the unsusceptibility to crack, the benefit of shotcrete strength, and the superiority of toughness. In this study, the several evaluation methods of FRS toughness were investgated experimentally, which included the ASTM beam test, EFNARC square panel test and RTA round panel test. Especially, it was examined that the round panel test could fulfill the toughness evaluation of FRS.

  • PDF

Rubbing Process Evaluation Method for The LCD Panel

  • Honoki, Hideyuki;Sakai, Kaoru;Kawabe, Shun'Ichi;Nakasu, Nobuaki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.115-117
    • /
    • 2002
  • In order to realize a stable rubbing process for the liquid crystal panel, the authors investigated the quantitative evaluation method of rubbing process uniformity. The proposed method focuses on the relationship between the image quality of the LCD panel for gray scale images and the rubbing uniformity. The proposed method indicates rubbing uniformity using quantitative parameters of spots and hairlines on the LCD panel.

  • PDF

Understanding and Attitude to Sustainable Development of College Students for a Nuclear Power Plant Construction in Education for Sustainable Development through Panel Discussion (패널토론을 적용한 지속가능발전교육에서 대학생의 원자력발전소 건립에 대한 지속가능발전 인식과 태도)

  • MOON, Sungchae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.5
    • /
    • pp.1236-1251
    • /
    • 2015
  • This study examined understanding and attitude of sustainable development(SD) of 38 college students in a nuclear power plant construction after education for sustainable development(ESD) through panel discussion. The results were as follows: First, after lesson 66% of students were expected that SD is possible if scientific technology is developed and a frugal life for the protection of environment is carried out. However, the remaining students regarded SD as an ideal concept, because they thought it is not possible to pursue environmental sustainability and socio-economic development simultaneously. Second, students' opinions in the evaluation of constructing a nuclear power plant in three aspects(environment, society and economy) before and after panel discussion were changed as follows; 1) After panel discussion, the objectors increased to 21% in economic evaluation, while the supporters increased to 11% in environmental evaluation. 2) Students majoring in engineering or natural sciences changed their opinions to agree in environmental evaluation because they considered a nuclear power plant safe and eco-energy. However students majoring in social science/business or liberal arts/arts changed their opinions to disagree in economic evaluation because they considered a nuclear power plant as high-cost energy when assessing danger-accidents cost, public consensus cost, operation and maintenance cost, and waste disposal cost. 3) This change of decision-making in students majoring in social science/business or liberal arts/arts after panel discussion was statistically significant(p<0.05). Implications of panel discussion as a teaching and learning method in ESD are also discussed.

An Experimental Study to Determine Proper Lighting Conditions in Powder Rooms

  • Kim, Hyun-Ji;Lim, Jang-Hyeon;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.54-62
    • /
    • 2013
  • In this study, a mock powder room was installed with variable LED lighting environments in order to conduct the experiments. The experimental conditions include luminaire type, illuminance ratio, vertical illuminance and color temperatures. The evaluation methods used were the Semantic Differential Method and a subjective evaluation on activities through observation. The SD evaluation result factor analysis categorizes ideas into three factors: brightness, emotion, and glare. The vertical bracket or the combined luminaire (luminous panel+ Vertical bracket) has better brightness than luminous panel. A vertical illuminance of 500lx is not significantly difference as compared to 600lx, allowing 500lx to be considered standard. The emotional atmosphere is evaluated as being better at lower color temperature. The luminous panel is the best for reducing glare while the vertical bracket is the worst. The best conditions differ according to the illuminance ratio of the luminous panel and vertical bracket. In the subjective evaluation (satisfaction with lighting environment, suitability to activity) the combined luminaire and 4000K received the best evaluation.

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Ceramic Panel and Painting Materials for Humidity Control (습도조절용 세라믹패널 및 도료의 흡·방습성능 평가)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.43-52
    • /
    • 2018
  • This study is conducted to evaluate the performance of ceramic panels and painting materials for humidity control which are developed in non-plastic room temperature hardening structure as part of a project to improve a residential environment for the low-income class, rather than the performance of high-priced humidity control materials that are produced with the existing plasticity processing. The testing methods included the measurements of absorption & desoprtion of humidity per material; Mock-up Testing; an evaluation method of comparing the absorption & desoprtion performances of Ecocarat, ceramic panels and painting materials through Living Lab. According to the measurements of absorption & desoprtion per material, ceramic panels, E panel, and ceramic painting material showed 73.3g/m2, 96.6g/m2, and 111.1g/m2, respectively. That is, the performance of humidity control of each material was found to be good in the order of: Ceramic Paint > E panel > Ceramic Panel. According to performance evaluation testing with Mock-up test and Living Lab, Ceramic Paint, Ecocarat, and Ceramic Panels showed better absorption & desoprtion performances in the order.

Development and Evaluation of a Next-Generation Sequencing Panel for the Multiple Detection and Identification of Pathogens in Fermented Foods

  • Dong-Geun Park;Eun-Su Ha;Byungcheol Kang;Iseul Choi;Jeong-Eun Kwak;Jinho Choi;Jeongwoong Park;Woojung Lee;Seung Hwan Kim;Soon Han Kim;Ju-Hoon Lee
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.1
    • /
    • pp.83-95
    • /
    • 2023
  • These days, bacterial detection methods have some limitations in sensitivity, specificity, and multiple detection. To overcome these, novel detection and identification method is necessary to be developed. Recently, NGS panel method has been suggested to screen, detect, and even identify specific foodborne pathogens in one reaction. In this study, new NGS panel primer sets were developed to target 13 specific virulence factor genes from five types of pathogenic Escherichia coli, Listeria monocytogenes, and Salmonella enterica serovar Typhimurium, respectively. Evaluation of the primer sets using singleplex PCR, crosscheck PCR and multiplex PCR revealed high specificity and selectivity without interference of primers or genomic DNAs. Subsequent NGS panel analysis with six artificially contaminated food samples using those primer sets showed that all target genes were multi-detected in one reaction at 108-105 CFU of target strains. However, a few false-positive results were shown at 106-105 CFU. To validate this NGS panel analysis, three sets of qPCR analyses were independently performed with the same contaminated food samples, showing the similar specificity and selectivity for detection and identification. While this NGS panel still has some issues for detection and identification of specific foodborne pathogens, it has much more advantages, especially multiple detection and identification in one reaction, and it could be improved by further optimized NGS panel primer sets and even by application of a new real-time NGS sequencing technology. Therefore, this study suggests the efficiency and usability of NGS panel for rapid determination of origin strain in various foodborne outbreaks in one reaction.

Effects of Design Factors of the Instrument Cluster Panel on Consumers' Affection Applying Robust Design (강건 설계기법을 이용한 자동차 게이지 클러스터의 디자인 요소와 고객 감성에 관한 연구)

  • Jung, Ga-Hun;Park, Sung-Joon;Kim, Seong-M.;Jung, Eui-S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.25-31
    • /
    • 2010
  • It is known from consumer surveys that the interior design of cars greatly influences on consumers' affection. Most notably, the instrument panel which occupies the driver's attention while driving would be one of the main components that affect consumer's affection, but the designer does not often put due importance to this design component. The purpose of this study is to define consumers' affection on the instrument cluster panel in terms of its design factors: color of panel lighting and layout of meters as independent factors. Semantic differentials or affective adjectives that are related to the instrument panel were first derived from surveys, existing studies and the available literature. Then, representative affective factors were drawn using factor analysis and multi-dimensional scaling (MDS). Evaluation of the instrument panel was performed and analyzed by Taguchi's robust design to provide more robust results under various noise factors which are color and material of car interior. Experiment revealed that consumers had five affective factors on the instrument panel and luxurious, charming, and visible affections are grouped into a factor and unique and dynamic affections in another factor. Evaluation of the instrument panel by Taguchi's robust design found that the white color of panel lighting and the panel with four meters was the most preferred design in terms of both the affection of luxury and uniqueness.

A Study on the development and application of air-passing soundproofing wall (통풍형 방음벽 개발 및 적용에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Kim, Keum-Mo;Jang, Kang-Seok;Ku, Bon-Sung;Eom, Joo-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.658-663
    • /
    • 2011
  • The purpose of this study is to develop an air-passing soundproofing panel with more improved structure to reduce the $CO_2$ emission and installation cost. To reduce the emission of $CO_2$ ; it is suggested to choose low $CO_2$ emission material relative to the aluminum and to reduce the materials by developing a specially designed air-passing soundproofing panel structure. First of all, we performed the flow analysis to predict the wind pressure according to the open angle of the air-passing soundproofing panel and the noise level analysis at the receiver point. To verify the simulation, a prototype of the soundproofing panel was made. The flow test in the wind tunnel and load test were performed. The economic evaluation for the installation of the air-passing soundproofing panel was performed and specifications of the installation was prepared. As the results of this research, it was verified that the wind load was reduced about 40% to that of the conventional one at 25m/s wind speed in the wind tunnel test. By applying the 4m span soundproofing wall with air-passing soundproofing panel and under the cost of 250 thousand $won/m^2$ instead of the conventional 2m span panel, the installation cost will always be lowered than the conventional one in the combination of (60:40~50:50) conventional to air-passing soundproofing panel from the economic evaluation. The 20% reduction of $CO_2$ was found by changing the 50% of aluminum soundproof panel to air-passing soundproofing panel.

  • PDF