• 제목/요약/키워드: pacemaker

검색결과 222건 처리시간 0.026초

생쥐 소장 및 대장 카할세포의 자발적 탈분극에서 택사의 효과에 관한 비교연구 (Effects of Alisma canaliculatum Extract in Pacemaker Potential of Intestinal Interstitial cells of Cajal in mice)

  • 권효은;박동석;김정남;김병주
    • 대한한의학방제학회지
    • /
    • 제30권2호
    • /
    • pp.37-44
    • /
    • 2022
  • Objectives : The purpose of this study was to examine the effects of Alisma canaliculatum Extract (ACE) on pacemaker potentials of small and large intestinal interstitial Cells of Cajal (ICC) in mice. Methods : We used enzymatic digestions to dissociate the ICC in the small and large intestine in mice. The whole-cell patch-clamp method was used to record pacemaker potentials in ICC. Results : 1. The ICC generated the pacemaker potentials in small intestine in mice. ACE (0.1-1mg/ml) induced membrane depolarization and decreased frequency with concentration-dependent manners. 2. Pretreatment with a Ca2+ free solution, Na+ 5 mM solution or 2-APB, a nonselective cation channel blocker, stopped the small intestinal ICC pacemaker potentials. In the case of Ca2+-free solution, Na+ 5 mM solution or 2-APB, ACE had no effects on the membrane depolarizations in small intestinal ICC. 3. The ICC generated the pacemaker potentials in large intestine in mice. Membrane depolarization appears regularly in the small intestine, but irregularly in the large intestine. ACE induced membrane depolarization (0.1-1mg/ml) and increased frequency (0.1-0.5mg/ml). 4. Pretreatment with a Ca2+ free solution, Na+ 5 mM solution or 2-APB, stopped the large intestinal ICC pacemaker potentials. In the case of Ca2+-free solution, Na+ 5 mM solution or 2-APB, ACE depolarized the membrane depolarizations in large intestinal ICC. 5. In mice, intestinal transit rate (ITR) values were dose-dependently decreased by the intragastric administration of ACE. Conclusions : These results suggest that ACE can regulate the pacemaker activity of ICC and the reaction by ACE is different from the small and large intestinal ICC, and the control of the intestinal motion by ACE may be caused by many complex processes.

Diversification of the molecular clockwork for tissue-specific function: insight from a novel Drosophila Clock mutant homologous to a mouse Clock allele

  • Cho, Eunjoo;Lee, Euna;Kim, Eun Young
    • BMB Reports
    • /
    • 제49권11호
    • /
    • pp.587-589
    • /
    • 2016
  • The circadian clock system enables organisms to anticipate the rhythmic environmental changes and to manifest behavior and physiology at advantageous times of the day. Transcriptional/translational feedback loop (TTFL) is the basic feature of the eukaryotic circadian clock and is based on the rhythmic association of circadian transcriptional activator and repressor. In Drosophila, repression of dCLOCK/CYCLE (dCLK/CYC) mediated transcription by PERIOD (PER) is critical for inducing circadian rhythms of gene expression. Pacemaker neurons in the brain control specific circadian behaviors upon environmental timing cues such as light and temperature cycle. We show that amino acids 657-707 of dCLK are important for the transcriptional activation and the association with PER both in vitro and in vivo. Flies expressing dCLK lacking AA657-707 in $Clk^{out}$ genetic background, homologous to the mouse Clock allele where exon 19 region is deleted, display pacemaker-neuron-dependent perturbation of the molecular clockwork. The molecular rhythms in light-cycle-sensitive pacemaker neurons such as ventral lateral neurons ($LN_vs$) were significantly disrupted, but those in temperature-cycle-sensitive pacemaker neurons such as dorsal neurons (DNs) were robust. Our results suggest that the dCLK-controlled TTFL diversify in a pacemaker-neuron-dependent manner which may contribute to specific functions such as different sensitivities to entraining cues.

Effects of Samchulkunbi-tang in Cultured Interstitial Cells of Cajal of Murine Small Intestine

  • Kim, Jung Nam;Kwon, Young Kyu;Kim, Byung Joo
    • 동의생리병리학회지
    • /
    • 제27권1호
    • /
    • pp.112-117
    • /
    • 2013
  • We studied the modulation of pacemaker activities by Samchulkunbi-tang (SCKB) in cultured interstitial cells of Cajal (ICC) from murine small intestine with the whole-cell patch-clamp technique. Externally applied SCKB produced membrane depolarization in the current-clamp mode. The pretreatment with $Ca^{2+}$-free solution and thapsigargin, a $Ca^{2+}$-ATPase inhibitor in endoplasmic reticulum, abolished the generation of pacemaker potentials and suppressed the SCKB-induced action. The application of flufenamic acid (a nonselective cation channel blocker) abolished the generation of pacemaker potentials by SCKB. However, the application of niflumic acid (a chloride channel blocker) did not inhibit the generation of pacemaker potentials by SCKB. In addition, the membrane depolarizations were inhibited by not only GDP-${\beta}$-S, which permanently binds G-binding proteins, but also U-73122, an active phospholipase C inhibitor. These results suggest that SCKB modulates the pacemaker activities by nonselective cation channels and external $Ca^{2+}$ influx and internal $Ca^{2+}$ release via G-protein and phospholipase C-dependent mechanism. Therefore, the ICC are targets for SCKB and their interaction can affect intestinal motility.

개심술을 통한 심박동기 와이어의 제거: 관상동맥 치환술을 받은 환자에서 심박동기 삽입 후 발생한 국소 감염의 치료 - 1예 보고 - (Pacing Wire Removal Via a Right Atriotomy: A Patient with Infected Permanent Pacemaker and Who Previously Underwent CABG - A case report -)

  • 김윤석;송현;유양기;정성호
    • Journal of Chest Surgery
    • /
    • 제42권2호
    • /
    • pp.256-258
    • /
    • 2009
  • 17년 전에 관상동맥 우회술을 시술 받은 63세 환자가 인공 심박동기 삽입 후 발생한 국소 감염으로 입원하였다. 피부 절개 후 심박동기를 견인하여 제거하려 하였으나 와이어가 뽑히지 않았고, 와이어는 절단하여 체내에 남겨둔 채로 치료를 종료하였다. 그러나 반복적으로 국소 감염이 재발하였고, 이에 우측 개흉술로 접근하여 인공 심폐 순환 후, 순환 정지 하에 우심방을 열고 와이어를 제거하였다.

정보제공이 영구형 심박조율기 이식환자의 불안, 지식 및 치료지시이행에 미치는 효과 (Effect of Providing Information on Anxiety, Knowledge and Compliance of Patients with a Permanent Pacemaker)

  • 이선경;유양숙
    • 성인간호학회지
    • /
    • 제17권3호
    • /
    • pp.484-492
    • /
    • 2005
  • Purpose: This study was undertaken to identify the effect of providing information on anxiety, knowledge and compliance in permanent pacemaker patients. Method: A quasi experimental design with non-equivalent control group and non-synchronized design was used. The subjects of this study were 50 patients who had received permanent pacemaker implantation at a university hospital in Seoul. They were divided into an experimental group of 22 patients who received education and a control group of 28 patients. The education was composed of group education(twice) and individualized reinforcement education(once) using an education booklet. Results: Anxiety decreased in the experimental group. Knowledge significantly increased in the experimental group compared to that in the control group. Compliance significantly increased in the experimental group. Conclusion: It can be concluded that providing information is effective for reducing anxiety, increasing knowledge and improving compliance of the permanent pacemaker patients.

  • PDF

영구적 인공심박동기 이식자의 적응 경험 (Study on Recipients' Experience of Adapting to Permanent Pacemakers)

  • 한순희;강정희
    • 중환자간호학회지
    • /
    • 제11권3호
    • /
    • pp.23-34
    • /
    • 2018
  • Purpose : This study develops a substantive theory on the recipients' experience of adapting to a permanent pacemaker. Method : The study used the grounded theory method developed by Strauss and Corbin (1998). The participants of the study were 13 adults who had received a permanent pacemaker during the previous year. The study addressed the research question "what is the experience of adaptation in people who had received permanent pacemakers?" From October 2016 to March 2017, data were collected from the participants through in-depth interviews. Results : The core category indicating the essence of the adaptation experience was shown to be "accepting the pacemaker as part of my body and living in line with it." Conclusions : In nursing practice, the results of this study will assist nurses in improving their communications with and developing guidelines or interventions for their clients who have received permanent pacemakers. In the field of nursing education, this study is expected to provide a framework to understand the experiences of future nurses and other healthcare workers working with permanent pacemaker recipients.

올가미를 이용한 영구 심박조율기 유도전극의 제거 -1 례 보고- (Removal of Entrapped Pacemaker Electrode - One Case Report -)

  • 이인규;성시찬;우종수
    • Journal of Chest Surgery
    • /
    • 제32권7호
    • /
    • pp.668-670
    • /
    • 1999
  • 심박조율기 제거의 가장 주요한 적응증은 감염이며. 감염이 발생하였을 경우, 흥분파 발생기와 유도전극 장치을 포함한 모든 심박조율기 하드웨어를 제거하는 것이 치료의 원칙으로 알려져 있다. 제거방법에는 지 속적 견인법, 겸자와 올가미 또는 바구니 사용법, locking stylet과 dilator sheath 사용법, 수술에 의한 방법등이 있다. 본원은 올가미 사용법으로 포착된 유도전극를 제거하였기에 이를 보고하는 바이다.

  • PDF

두개의 전극도자를 사용하게 된 Permanent Transvenous Pacemaker Implantation: 1례 보고 (Permanent Transvenous Endocardial Pacemaker Inevitably Implanted Two Electrode Leads)

  • 곽문섭;이홍균
    • Journal of Chest Surgery
    • /
    • 제14권2호
    • /
    • pp.168-174
    • /
    • 1981
  • Since cardiac pacemaker was first totally implanted by Chardack, Gage and Greatbatch [1966], the electrical circuity of the cardiac pacemaker has been improved, modified, and refined. The problem of transvenous electrodes, however, is still remained; this may be due to electrode displacement, exit and/or entrance block, lead fracture and insulation defects. In permanent cardiac pacing, Irreversible loss of function of the transvenous electrode catheter eventually requires insertion of new lead. Authors now report one case that disclosed easy displacement of electrode tip in early phase of implantation and then two years and five months later, malfunctioning electrode could not be withdrawn from the cardiovascular system because it has become firmly enclosed by fibrous tissue along its course from the vein tract to the right ventricle. Under such circumstances, the electrode catheter tip was left in tricuspid annulus after being sutured at its entrance and burying the loop of lead in generator pocket. New other one electrode was then reimplantation through left external jugular vein.

  • PDF

A Case Report of Rare Complications after Epicardial Permanent Pacemaker Implantation in an Infant: Airway Compression, Skin Necrosis, and Bowel Perforation

  • Kim, Woojung;Kwak, Jae Gun;Min, Jooncheol;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • 제53권2호
    • /
    • pp.82-85
    • /
    • 2020
  • Insertion of an epicardial pacemaker is a useful treatment for pediatric patients with an abnormal heart rhythm. However, there are limitations and concerns when implanting epicardial pacemakers in infants and neonates due to their small body size. We report a patient who experienced rare complications after implantation of a permanent pacemaker.

An Implantable Antenna for Wireless Body Area Network Application

  • Kim, Ui-Sheon;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • 제10권4호
    • /
    • pp.206-211
    • /
    • 2010
  • In this paper, an implantable planar inverted-F antenna (PIFA) for an artificial cardiac pacemaker is proposed. The antenna has a simple structure with a low profile and is placed on the top side of the pacemaker. The dimensions of the pacemaker system, including the antenna element, are $42{\times}43.6{\times}11$ mm. When the antenna is embedded in pig tissue, its $S_{11}$ value is -10.94 dB at 403 MHz and the -10 dB impedance bandwidth of the antenna is 6 MHz (399~406 MHz). The proposed PIFA in tissue has a peak gain of -20.19 dBi and a radiation efficiency of 1.12 % at 403 MHz. When the proposed antenna is placed in a flat phantom, its specific absorption ratio (SAR) value is 0.038 W/kg (1 g tissue). Performances of the proposed PIFA is sufficient to operate at the MICS band (402 ~ 405 MHz).