• Title/Summary/Keyword: pH titration

Search Result 192, Processing Time 0.023 seconds

Automatic Titration Using Micro pH Electrode in Volatile Basic Nitrogen Analysis (마이크로 pH전극을 이용한 휘발성염기질소의 자동적정)

  • Lee, Hyeong-Choon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.4
    • /
    • pp.507-509
    • /
    • 2006
  • An automatic titration was performed by a home-made automatic control system adopting a micro pH electrode as its sensing part in microdiffusion-based volatile basic nitrogen (VBN) analysis. The micro electrode was considered to be adequate for automatic VBN analysis because of its small sensor size, low immersion depth and unbreakable body. Six pork samples in different degree of freshness were analyzed both manually and automatically. The data from automatic titration were not significantly different from those taken by manual titration even at 15% significance level. The correlation coefficient was 1.000.

Comparison of Titration Curve Estimation Methods for pH Neutralization Processes

  • Park, Ho-Cheol;Lee, Jie-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.124.1-124
    • /
    • 2001
  • Control of pH neutralization process plays a very important role in some chemical process. Because of their high nonlinearity, frequent disturbance, and time-varying characteristics, it is difficult to control and estimate pH processes. For the adaptive control of pH processes, a lot of researchers have made an efforts in the modeling and control of pH processes. It is very difficult to obtain information of influent stream such as concentrations and dissociation constants and the titration curve equation is very complex. Therefore, several simple models, which hate small number of unknown parameters and estimate the titration curve, have been available, These models were considered here and were transformed into forms that can applied the linear least square method.

  • PDF

A Review on Alkalinity Analysis Methods Suitable for Korean Groundwater (우리나라 지하수에 적합한 알칼리도 분석법에 대한 고찰)

  • Kim, Kangjoo;Hamm, Se-Yeong;Kim, Rak-Hyeon;Kim, Hyunkoo
    • Economic and Environmental Geology
    • /
    • v.51 no.6
    • /
    • pp.509-520
    • /
    • 2018
  • Alkalinity is one of the basic variables, which determine geochemical characteristics of natural waters and participate in processes changing concentrations of various contaminants either directly or indirectly. However, not a few laboratories and researchers of Korea still use alkalinity-measurement methods not appropriate for groundwaters, and which becomes one of the major reasons for the poor ion balance errors of the geochemical analysis. This study was performed to review alkalinity-measurement methods, to discuss their advantages and disadvantages, and, thus, to help researchers and analytical specialists in analyzing alkalinity of groundwaters. The pH-titration-curve-inflection-point (PTC-IP) methods, which finds the alkalinity end point from the inflection point of the pH titration curve are revealed to be most accurate. Gran titration technique among them are likely to be most appropriate for accurate estimation of titrant volume to the end point. In contrast, other titration methods such as pH indicator method and pre-selected pH method, which are still commonly being used, are likely to cause erroneous results especially for groundwaters of low ionic strength and alkalinity.

Characterization of Poly(styrene-b-vinylbenzylphosphonic acid) Copolymer by Titration and Thermal Analysis

  • Kim, Sang-Hun;Park, Young-Chul;Jung, Gui-Hyun;Cho, Chang-Gi
    • Macromolecular Research
    • /
    • v.15 no.6
    • /
    • pp.587-594
    • /
    • 2007
  • Well defined amphiphilic diblock copolymers of poly(styrene-b-vinylbenzylphosphonic acid) (PS-b-PVBPA) were prepared by controlled radical polymerization technique, two-step hydrolysis reactions using trime-thylsilyl bromide from the corresponding phosphonic ethyl ester. By indirect, backward pH titration of the block copolymer, a good titration curve of a dibasic acid was observed. The IEC values obtained from both backward pH titration and volumetric back titration were almost identical. Thermal gravimetric analysis (TGA) of the phosphonic acid containing block copolymer showed a high thermal stability up to $400^{\circ}C$.

Comparison for the Optimal Pressure between Manual CPAP and APAP Titration with Obstructive Sleep Apnea Patients (한국인 폐쇄성 수면 무호흡 환자의 적정 양압을 위한 수동화 양압 측정법과 자동화 양압 측정법의 비교)

  • Kim, Dae Jin;Choi, Byoung Geol;Cho, Jae Wook;Mun, Sue Jean;Lee, Min Woo;Kim, Hyun-Woo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.191-197
    • /
    • 2019
  • Although auto-adjusting positive airway pressure (APAP) titration at home has several advantages over a CPAP titration in terms of convenience and time saving, there are still concerns as to whether it will show corresponding accuracy when compared to laboratory-based polysomnography (PSG) and CPAP titration. To obtain more evidence supporting home-based auto-titration, APAP titration was performed at home for patients who were presented with OSA on laboratory-based diagnostic PSG followed by CPAP titration. A total of 79 patients were included in the study. They all underwent split-night PSG with CPAP titration, and APAP titration for more than 7 days. The patients with successful titration at both situations were selected. The optimal pressure and apnea-hypopnea index (AHI) of CPAP and APAP titration were compared. The optimal pressure for CPAP and APAP titration were $7.0{\pm}1.8cmH_2O$ and $7.6{\pm}1.6cmH_2O$ (P<0.001), whereas the corresponding AHI were $1.3{\pm}1.5/h$ and $3.0{\pm}1.7/h$ (P<0.001). As a result, the achievement rates of optimal pressure for CPAP and APAP titration were 96.2% and 94.9% (r=-0.045, P=0.688), respectively. The results of this study did not differ with regard to the optimal pressure between CPAP and APAP titration. Overall, CPAP and APAP titrations should be chosen depending on a required situation.

Influence of pH on Chelation of BaCl2 and EDTA Using Isothermal Titration Calorimetry (등온적정열량계를 이용한 BaCl2와 EDTA 킬레이션 결합 반응의 pH 영향)

  • Ga Eun Yuk;Ji Woong Chang
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.279-284
    • /
    • 2023
  • Isothermal titration calorimetry (ITC) is a useful technique to obtain thermodynamic binding properties such as enthalpy, Gibbs free energy, entropy, and stoichiometry of the chelation reaction. A single independent binding site model was used to evaluate the thermodynamic binding properties in BaCl2 and ethylenediaminetetraacetic acid (EDTA) in Trince and HEPES buffers. ITC enables us to elucidate the binding mechanism and find an optimal chelation condition for BaCl2 and EDTA in the pH range of 7~11. Chelation of BaCl2 and EDTA is a spontaneous endothermic reaction. As pH increased, entropic contributions dominated. The optimal pH range is narrow around pH 9.0, where 1:1 binding between BaCl2 and EDTA occurs.

The Potentiometric Titration Curves on Ammonia Absorption of Carboxylic Ion Exchanger (카르복실 이온교환수지의 암모니아 흡착에 대한 전위차 적정곡선)

  • Kim, T.I.;Son, W.K.
    • Applied Chemistry for Engineering
    • /
    • v.10 no.7
    • /
    • pp.969-973
    • /
    • 1999
  • In this work, we studied the degree of hydrolysis of ion exchanger in $NH_4OH$ solution and sorption characteristics of $NH_3$ by potentiometric titration curves with using carboxylic acid ion exchanger Fiban K-4. We knew that the theoretical pH values agreed with the experimental pH values on the $NH_4OH$ concentrations in various concentrations of supporting electrolyte $(NH_4)_2SO_4$. The sorption values of $NH_3$ using the ion exchanger can be calculated from equivalent sorption curves for various pH. Also, the degree of hydrolysis increased with decreasing concentration of supporting electrolyte and pH. In order to obtain the mono ion form below 0.01 M as the decreasing concentration of supporting electrolyte, the pH values should be increased. From these results, therefore, the concentrations of supporting electrolyte and pH values were determined.

  • PDF

A Modified Back-Titration Method to Measure Soil Titration Curves Minimizing Exchange Acidity and Dilution Effects (토양 적정곡선 측정을 위하여 교환산도와 희석효과를 최소화한 수정역적정법 제안)

  • Jozefaciuk, G.;Shin, Jae Sung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.4
    • /
    • pp.321-327
    • /
    • 1996
  • A back titration method was suggested to determine the exchangeable acidity of soil originated from exchangeable aluminum and adsorbed hydrogen ion in relation to minimizing its titration error. In this method. soils are treated by neutral salt solution whose concentration is the same as soil solution suspended by distilled water. And then. its pH is adjusted at 3, using 1 N HCl solution and back-titrated by 0.1 N NaOH solution containing 1 N NaCl. The results of the suggested back-titration showed the possibility of practical application with linear relationship to that of standard method.

  • PDF

An Isothermal Titration Microcalorimetric Study on the Interaction of Three Water-Soluble Porphyrins with Histone H2B

  • Bordbar, A.K.;Ghaderi, A.R.;Safaei, E.;Tangestaninejad, S.;Eslami, A.;Saboury, A.A.;Moosavi Movahedi, A.A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.5
    • /
    • pp.547-551
    • /
    • 2003
  • In the present work, the interaction of three water soluble porphyrins, tetra(p-trimethyle) ammonium phenyl porphyrin iodide (TAPP) as a cationic porphyrin, tetra sodium meso-tetrakis (p-sulphonato phenyle) porphyrin (TSPP) as an anionic porphyrin and manganese tetrakis (p-sulphonato phenyl) porphinato acetate (MnTSPP) as a metal porphyrin, with histone H₂B have been studied by isothermal titration microcalorimetry at 8 mM phosphate buffer, pH 6.8 and 27 °C. The values of binding constant, entropy, enthalpy and Gibbs free energy changes for binding of the first MnTSPP, and first and second TSPP and TAPP molecules were estimated from microcalorimetric data analysis. The results represent that the process is both entropy and enthalpy driven and histone induces self-aggregation of the porphyrins. The results indicate that both columbic and hydrophobic interactions act as self-aggregation driving forces for the formation of aggregates around histone.

Effects of Ionizable Groups on the Redox Potentials of Cytochrome c₃from D. vulgaris Miyazaki F

  • 박장수;강신원
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.9
    • /
    • pp.820-826
    • /
    • 1996
  • The p2H dependence of the NMR chemical shifts of the proton signals of heme methyl groups and ionizable groups in the vicinity of the heme were investigated. The p2H titration of heme methyl signals in four macroscopic oxidation states by saturation tranfer method was performed in the range between p2H 5.2 and 9.0. While the p2H dependence of the heme methyl resonance in fully oxidized state was small, most resonances in the intermediate oxidation states showed certain shifts. Particularly, methyl resonances of heme 1 (sequential heme numbering) exhibited sharp p2H dependence in acidic range. β-CH2 of the propionate of hemes 1 and 4 were titrated in the range of p2H 4.5-9.0. Only the 6-propionate group of heme 1 was protonated in this p2H range and its titration curve was similar to those of methyl resonances of heme 1 in intermediate oxidation states. Analysis of the microscopic redox potentials showed that they change depending on p2H. The ionizable groups responsible for the p2H dependence of these potentials are 6-propionate of heme 1 in acidic range and His 67 in basic range.