• Title/Summary/Keyword: pH Sensor

Search Result 491, Processing Time 0.037 seconds

A Water Quality Control Model using Sensor System (센서 시스템을 이용한 수질 제어 모델)

  • Seo, Shin-Bae;Choi, Kyu-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.455-456
    • /
    • 2007
  • Nowaday it is main issues for us to protect from the polluted water which is flowing in streams and rivers simultaneously. This paper proposed a water maintenance control system using pH sensor. Also the work enables water analysis downloading VHDL coding to FPGA through Max+plus II simulation tool for display realization.

  • PDF

THE DEVELOPMENT OF INDWELLING WIRELESS PH TELEMETRY OF INTRAORAL ACIDITY (구강 내 산도의 생체 내 측정을 위한 wireless pH telemetry의 개발)

  • Kim, Hyung-Jun;Kim, Jae-Moon;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • The purpose of this study was to develop the wireless pH telemetry lasting longer than 24 hours in the mouth to overcome the limits of conventional wire telemetry previously used for salivary and plaque pH measurement, and to assess its effectiveness. We developed a wireless pH telemeter which can measure and store the pH profile data during more than 24 hours. It was composed of intraoral part; pH sensor of antimony electrode, battery and microprocessor for data storage, and extraoral part; control/data receiver and data analyzing software which was newly made for this device. After inspecting wireless electrode for accurate measurement, it was attached to the removable intraoral appliance and delivered to the volunteer who was told to wear except brushing time, retrieved after 24 hours and finally the pH profile data was extracted and analyzed. When compared with conventional wire telemetry, this device showed similar results and induced less discomfort to examinees. The data showed pH changes at same time when examinees ate various scheduled foods and beverages. With this method it became possible to accurately measure pH changes within mouth for long time in accordance with individual's lifestyle, definitely reducing the discomfort inflicted to the examinees' life.

  • PDF

Reduced Graphene Oxide Field Effect Transistor for Detection of H+ Ions and Their Bio-sensing Application

  • Sohn, Il-Yung;Kim, Duck-Jin;Yoon, Ok-Ja;Tien, N.T.;Trung, T.Q.;Lee, N.E.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.195-195
    • /
    • 2012
  • Recently, graphene based solution-gated field-effect transistors (SGFETs) have been received a great attention in biochemical sensing applications. Graphene and reduced graphene oxide (RGO) possess various advantages such as high sensitivity, low detection limit, label-free electrical detection, and ease of fabrication due to their 2D nature and large sensing area compared to 1D nanomaterials- based nanobiosensors. Therefore, graphene or RGO -based SGFET is a good potential candidate for sensitive detection of protons (H+ ions) which can be applied as the transducer in various enzymatic or cell-based biosensing applications. However, reports on detection of H+ ions using graphene or RGO based SGFETs have been still limited. According to recent reports, clean graphene grown by CVD or exfoliation is electrochemically insensitive to changes of H+ concentration in solution because its surface does not have terminal functional groups that can sense the chemical potential change induced by varying surface charges of H+ on CVD graphene surface. In this work, we used RGO -SGFETs having oxygen-containing functional groups such as hydroxyl (OH) groups that effectively interact with H+ ions for expectation of increasing pH sensitivity. Additionally, we also investigate RGO based SGFETs for bio-sensing applications. Hydroloytic enzymes were introduced for sensing of biomolecular interaction on the surface of RGO -SGFET in which enzyme and substrate are acetylcholinesterase (AchE) and acetylcholine (Ach), respectively. The increase in H+ generated through enzymatic reaction of hydrolysis of Ach by AchE immobilized on RGO channel in SGFET could be monitored by the change in the drain-source current (Ids).

  • PDF

A Solid-Contact Indium(III) Sensor based on a Thiosulfinate Ionophore Derived from Omeprazole

  • Abbas, Mohammad Nooredeen;Amer, Hend Samy
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1153-1159
    • /
    • 2013
  • A novel solid-contact indium(III)-selective sensor based on bis-(1H-benzimidazole-5-methoxy-2-[(4-methoxy-3, 5-dimethyl-1-pyridinyl) 2-methyl]) thiosulfinate, known as an omeprazole dimer (OD) and a neutral ionophore, was constructed, and its performance characteristics were evaluated. The sensor was prepared by applying a membrane cocktail containing the ionophore to a graphite rod pre-coated with polyethylene dioxythiophene (PEDOT) conducting polymer as the ion-to-electron transducer. The membrane contained 3.6% OD, 2.3% oleic acid (OA) and 62% dioctyl phthalate (DOP) as the solvent mediator in PVC and produced a good potentiometric response to indium(III) ions with a Nernstian slope of 19.09 mV/decade. The constructed sensor possessed a linear concentration range from $3{\times}10^{-7}$ to $1{\times}10^{-2}$ M and a lower detection limit (LDL) of $1{\times}10^{-7}$ M indium(III) over a pH range of 4.0-7.0. It also displayed a fast response time and good selectivity for indium(III) over several other ions. The sensor can be used for longer than three months without any considerable divergence in potential. The sensor was utilized for direct and flow injection potentiometric (FIP) determination of indium(III) in alloys. The parameters that control the flow injection method were optimized. Indium(III) was quantitatively recovered, and the results agreed with those obtained using atomic absorption spectrophotometry, as confirmed by the f and t values. The sensor was also utilized as an indicator electrode for the potentiometric titration of fluoride in the presence of chloride, bromide, iodide and thiocyanate ions using indium(III) nitrate as the titrant.

Highly Selective Triiodide Polymeric Membrane Electrode Based on Tetra(p-chlorophenyl)porphyrinato Manganese (Ⅲ) Acetate

  • Farhadi, Khalil;Shaikhlouei, Hossain;Maleki, Ramin;Sharghi, Hashem;Shamsipur, Mojtaba
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.11
    • /
    • pp.1635-1639
    • /
    • 2002
  • A new solvent polymeric membrane sensor based on tetra(p-chlorophenyl)porphyrinato manganese (III) acetate is described which demonstrates excellent selectivity toward the triiodide ion. The electrode has a linear dynamic range between 1.0 ${\times}$ $10^{-2}$ M and 7.0 ${\times}$$10^{-6}$M with a Nernstian slope of $-59.6{\pm}1$ mV per decade and a detection limit of 5.0 ${\times}$$10^{-6}$M. The proposed sensor revealed good selectivities for triiodide over a wide variety of other anions and could be used in a pH range 2-9. The electrode can be used for at least two months without any considerable divergence in potential. It was applied as indicator electrode in potentiometric titration of the triiodide and As(III) ions.

Highly Sensitive Colorimetric Formaldehyde Gas Sensors using Nylon Sheet and Dye (나일론 시트와 염료를 이용한 고감도 색변환 포름알데히드 가스 센서)

  • Jung, Suenghwa;Cho, Yeong Beom;Kim, Yong Shin
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.420-426
    • /
    • 2017
  • A colorimetric sensor was investigated to achieve a low-cost warning device for harmful gaseous formaldehyde (HCHO). The sensor is based on selective reactions between hydroxylamine sulfate and HCHO, leading to the production of sulfuric acid. The produced acid results in color-changing response through the acid-base reaction with dye molecules impregnated on a solid membrane substrate. For attaining this purpose, sensors were fabricated by drop-casting a dye solution prepared using different pH indicators on various commercially available polymer sheets, and their colorimetric responses were evaluated in terms of sensitivity and reliability. The colorimetric sensor using bromophenol blue (BPB) and nylon sheet was found to exhibit the best performance in HCHO detection. An initial bluish green of a sensor was changed to yellow when exposed to gaseous formaldehyde. The color change was recorded using an office scanner and further analyzed in term of RGB distance for quantifying sensor's response at different HCHO(g) concentrations. It exhibited a recognizable colorimetric response even at 50 ppb, being lower than WHO's standard of 80 ppb. In addition, the sensor was found to have quite good selectivity in HCHO detection under the presence of common volatile organic compounds such as ethanol, toluene, and hexane.

Electrochemical Analysis and Applications of Tetracycline Transfer Reaction Process at Liquid/liquid Interfaces (액체/액체 계면에서 테트라사이클린 전이반응의 전기화학적 분석 및 응용)

  • Liu, XiaoYun;Han, Hye Youn;Goh, Eunseo;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.506-512
    • /
    • 2017
  • The transfer reaction characteristics of tetracycline (TC) across a polarized water/1,2-dichloroethane (1,2-DCE) interface was studied via controlling both pH and ionic strength of the aqueous phase in conjunction with cyclic and differential pulse voltammetries. Formal transfer potential values of differently charged TC ionic species at the water/1,2-DCE interface were measured as a function of pH values of the aqueous solution, which led to establishing an ionic partition diagram for TC. As a result, we could identify which TC ionic species are more dominant in the aqueous or organic phase. Thermodynamic properties including the formal transfer potential, partition coefficient and Gibbs transfer energy of TC ionic species at the water/1,2-DCE interface were also estimated. In order to construct an electrochemical sensor for TC, a single microhole supported water/polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) gel interface was fabricated. A well-defined voltammetric response associated with the TC ion transfer process was achieved at pH 4.0 similar to that of using the water/1,2-DCE interface. Also the measured current increased proportionally with respect to the TC concentration. A $5{\mu}M$ of TC in pH 4.0 buffer solution with a dynamic range from $5{\mu}M$ to $30{\mu}M$ TC concentration could be analyzed when using differential pulse stripping voltammetry.

A Study on Optimal Design of Automotive Hydraulic Control System for Slip Ratio Control (슬립율 제어를 위한 자동차용 유압 조절시스템의 최적 설계에 관한 연구)

  • 김대원;김진한;최석창
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.41-50
    • /
    • 1998
  • In this study, to investigate a characteristics of slip ratio control of H.C.U for ABS, half car model tester were developed and a new H.C.U. was compactly designed comparing to the commercical H.C.U. for ABS. In half car model tester, variable inertia wheel has been used to load the car weights and braking forces according to the road surface conditions which were realized by pneumatic cylinder. And solenoid valves using P.W.M. (Pulse Width Modulation) method were installed in the new H.C.U The slip ratio characteristics of tire had been measured using half car model tester and the results were used in the control simulation for a new H.C.U.

  • PDF