• Title/Summary/Keyword: pH 검출

Search Result 1,365, Processing Time 0.026 seconds

Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (Ⅳ). Continuous-Automated Determination of Sulfide Ion Using Tubular PVC Membrane Type pH Electrode (용해기체 분석용 기체감응막 이온선택성 전극 (제 4 보) 관형 PVC막 pH전극을 이용한 황화이온의 연속 · 자동화 정량)

  • Lee Heung Lark;Bae Zun Ung;Oh Sang-Hyub
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.638-643
    • /
    • 1992
  • The analytical response properties of two types of continuous flow-through electrode system as fulfide ion detectors are examined and directly compared their reponse characteristics under the optimal conditions. In both detection systems, observed peak potentials are logarithmically related to the sulfide ion concentration and at least twenty samples per hour can be determined. In the pH electrode method, the pH of the flowing recipient stream leaving the dialyzer was monitored. The designed system involves the use of continuous flow gas dialyzer in conjunction with the tubular polymer membrane electrode. In this method, optimal experimental conditions are recipient of mixture of $5.0 {\times} 10^{-5} M NaOH + 5.0 {\times} 10^{-3} M$ NaCl and diluent of 0.10 M $H_2SO_4$, and all flow rates of recipient stream, diluent stream, and sample are 1.0 ml/min. In the sulfide ion electrode method, a commercially available sulfide ion-selective electrode was used to detect sulfide ion in the flow-through cell. The optimal flow rates of sulfide anti-oxidant buffer (3.5 g ascorbic acid and 7.6 g $Na_2EDTA$ dissolved in 1.0 M NaOH solution 1 l) and sample were 1.4 ml/min and 1.0 ml/min, respectively.

  • PDF

A Study of Liquid Chromatographic Detection Method for Thiocarbamates by Using Photochemical Reaction (광화학 반응을 이용한 티오카바메이트류의 액체 크로마토그래피 검출법에 관한 연구)

  • Dai Woon Lee;Young Hun Park;Yong Wook Choi
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.4
    • /
    • pp.453-461
    • /
    • 1993
  • Detection method was developed using a simply designed photochemical reactor made of teflon coil and low pressure mercury lamp. This method of UV photolysis of analytes followed by UV, fluorescence and electrochemical detection was found to be useful for four thiocarbamates. Analytes eluting from the column are irradiated with a high flux of 254 nm UV light, so that they change to either fluorescent active forms or highly electrochemically sensitive products. Appling this technique to the UV detection, thiocarbamates were converted into long wavelength absorbing products upon UV irradiation. In fluorescence detector four thiocarbamates are not detected at nonirradiated condition but fluorescence signals of MPTC, CPTC photolysates are appeared after irradiation with UV light. The electrochemical detection for the determination of thiocarbamates was enhanced up to 5∼20 fold signal after UV irradiation, compared to that of the nonirradiated. The detection limit of thiocarbamates on electrochemical detector was 13.3∼0.02 ng under pH 7.0, ionic strength $0.5{\times}10^{-2}$ M, phosphate buffer solution. Adducts produced by reaction of photolysates and OPA-MERC in the reaction coil were monitored at 425 nm with fluorescence detector, and one of the photolysates was primary amine.

  • PDF

Changes in pH, Sensory Properties and Volatile Odor Components of Kimchi by Heating (가열에 의한 김치의 pH, 관능성 및 휘발성냄새성분의 변화)

  • Ko, Young-Tae;Baik, In-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.1123-1126
    • /
    • 2002
  • Kimchi was ripened at $25^{\circ}C$ for 4 days and heated at $100^{\circ}C$ for 10 or 40 min. pH of the ripened kimchi was not changed by heating, whereas sensory properties of kimchi, including overall acceptability, acidity, taste, odor, and texture, were improved, particularly by $100^{\circ}C/40$ min-heating. Allyl mercaptan, methyl allyl sulfide, dimethyl disulfide, diallyl sulfide, diallyl disulfide, and ethanol were detected in the ripened kimchi. Volatile odor components except ethanol and methyl allyl sulfide were removed by heating at $100^{\circ}C/10$ min, and the ethanol content was further reduced by heating at $100^{\circ}C/40$ min.

Quality Characteristics of Commercial Korean Types of Fermented Soybean Sauces in China (중국 내 시판 한식 장류의 품질특성)

  • Lee, Sun Young;Baik, Soo Hwa;Ahn, Yu Jin;Song, Jin;Kim, Jae Hyun;Choi, Hye Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.796-800
    • /
    • 2013
  • Soybean-based fermented foods have been used as traditional condiments in Korea, Japan and China. Thirteen Korean types of soybean sauce that had been manufactured and sold in China were examined to evaluate their quality. The pH, salinity, and moisture content of the samples were pH 5.17-6.86, 8.0%-23.0%, and 46.446-70.40%, respectively. The amino-type nitrogen content was in the range of 199.18 to 736.46 mg%. The total aerobic bacterial counts were 4.83-7.89 Log CFU/g. The coliform count of gochujang (CNH-2) was 2.31 Log CFU/g, but none were detected in the other samples. Moreover, Bacillus cereus counts from samples of doenjang and gochujang were in the range 2.00-4.09 Log CFU/g. The protease and amylase activity of samples were 379.02-781.36 unit/g and 5.29-63.27 unit/g, respectively.

Purification and N-Terminal Study of Bence Jones Proteins (Bence Jones 단백질(蛋白質)의 정제(精製) 및 N-말단검출(末端檢出))

  • Kim, Jun-Pyong
    • Applied Biological Chemistry
    • /
    • v.13 no.1
    • /
    • pp.59-64
    • /
    • 1970
  • Human Bence Jones Protein could be purified by DEAF-Sephadex A-50 column $(2{\times}37cm)$ with 0.02M phosphate Buffer (pH 8.0) and gradient increasing with NaCl concentration as in Fig. 2-4. Sample As (K-type Bence Jones Protein) had two component, F-I was major component and its dried weight was 350mg. of starting material of 500mg. Other Sample Im and Ik (${\lambda}$-type Bence Jones Protein) was purified by DEAE-Sephadex A-50 with 0.02M phosphate Buffer(pH 8.0)too. F-I (major component) of Im and F-I of Ik were 242mg and 146mg. its dried weight respectively. K-type of Bence Jones Protein's(As, Ko, Ta.) N-terminal amino acid residue was determined by method of DNP,. K-type of Bence Jones Protein's amino acid residue were either glutamic acid or aspartic acid. Sample Ta was confirmed as glutamic acid its N-Terminal. As and Ko were aspartic acid. Each yellowish spot (DNP-amino acids) were extracted with 4ml. of pH 8.05% $NaHCO_3$ solution and calculated its recovery by O.D. $(360m{\mu}$ using the ${\varepsilon}=18.1{\times}10^3DNP$ $Asp\;{\varepsilon}=17.41{\times}10^(3)\;DNP\;Glu$ considering 50% lose during; the acid (6N-HCI) hydrolysis. Recovery of ko and As were 54.3% and 65% of its starting materials (DNP-Protein). Sample Ta's recovery was 85% of its DNP-protein. ${\lambda}$-type of Bence Jones Protein was rot investigated its N-terminal amino acid residue by DNP-method, probably it was blocked its N-terminal residue with glutamic acid.

  • PDF

Elution Buffers for Human Enteric Viruses in Vegetables with Applications to Norovirus Detection

  • Moon, Aerie;Ahn, Jaehyun;Choi, Weon Sang
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.4
    • /
    • pp.287-292
    • /
    • 2013
  • The efficient elution of viruses from contaminated food is a critical step for its detection. In this study, conditions optimal for enteric viral recovery from three leafy vegetables (cabbage, lettuce, sesame leaf) and three root vegetables (carrot, onion, mooli) were analyzed to find common buffers (statistically not different) applicable to the leafy and root vegetables. Viral recovery varied depending on the food matrices or elution buffers. Buffer solutions containing 0.25M threonine / 0.3M NaCl (pH 9.5) or 0.25M glycine / 0.14M NaCl (pH 9.5) could efficiently recover poliovirus from five out of six vegetables. The threonine buffer was applied to one leafy vegetable (sesame) and one root vegetable (carrot) for genogroup II norovirus (NoV) detection. The detection sensitivity was significantly higher from the leafy vegetable compared to the root vegetable. The use of these common elution buffers should facilitate the detection of low levels of NoV and other enteric viruses in a wide range of vegetables.

Effect of Whey Brew Cultured by Lactobacillus helveticus ATCC 55163 and Propionibacterium acidipropionici 5020 on Quality Characteristics of Bread (Lactobacillus helveticus ATCC 55163과 Propionibacterium acidipropionici 5020로 배양한 유청발효물이 빵의 품질특성에 미치는 영향)

  • Yun, Mi-Sug;Lee, Jeong-Hoon;Lee, Si-Kyung
    • Food Science of Animal Resources
    • /
    • v.30 no.3
    • /
    • pp.458-465
    • /
    • 2010
  • This study evaluated the effect of whey brew cultured by Lactobacillus helveticus ATCC 55163 and Propionibacterium acidipropionici 5020 on bread quality characteristics. Ten and 15% whey brew were added to flour-based bread, after which bread volume, pH, total titratable acidity (TTA), moisture content, water activity, texture, organic acid content, and sensory evaluation were analyzed. The bread volume and TTA of control were the largest among the samples, whereas pH was the lowest. Moisture content did not significantly differ depending on the amount of whey brew added, though water activity was highest in the bread with 10% whey brew. However, hardness was the lowest in bread with 10% whey brew. Propionic acid was not detected while succinic acid, lactic acid, and acetic acid were detected in small amounts in the control compared to the test samples. Succinic acid, acetic acid, and lactic acid content was high in bread with 15% whey brew, with propionic acid present at a very high amount. In terms of sensory evaluation, bread with 10% whey brew had the highest score. As a result, high quality characteristics were associated with the bread with 10% whey brew, whereas long preservation was a characteristic of the bread with 15% whey brew.

Effect of Pediocin Treatment on Soybean curd Quality during Storage (Pediocin 용액침지가 두부의 저장성에 미치는 영향)

  • Park, Su-Jung;Park, Kee-Jai;Jeong, Seong-Weon;Kim, Seok-Joong;Youn, Kwang-Sup
    • Food Science and Preservation
    • /
    • v.14 no.2
    • /
    • pp.131-135
    • /
    • 2007
  • We investigated the effects of pediocin on physicochemical and microbial changes in soybean cut 9 days of storage at $10^{\circ}C$, in order to improve shelf-life. As the storage time of curd increased the pH of solutions treated by pediocin immersion did not vary greatly, whereas the pH of control curd decreased after 5 days of storage. Titratable acidity increased in non-treated curd after 5 days of storage, and also in cud immersed in pediocin solutions of 300 and 500 ppm, after 6 and 7 days of storage, respectively. A pediocin solution of 1,000 ppm the development of titratable acidity. Also, turbidity did not increase during storage of curd treated with a pediocin solution of 1,000 ppm. The bacterial count of the immersion solution was $10^{2.5}$ CFU/mL at the commencement of storage, remained stable for 5 days of storage, and then increased rapidly. Coliforms were detected in untreated curd after 2.5days of storage. In curd treated with 300, 500 or 1,000ppm of pediocin, the elapsed times to coliform detection were 3.5 days, 5 days and 7 days, respectively, It is thus possible to prevent the deterioration of soybean curd with pediocin treatment.

Simultaneous Purification of Enterotoxin A and C by Fast Protein Liquid Chromatography (FPLC에 의한 Staphylococcal Enterotoxin A와 C의 동시분리)

  • Lee, Jung-Hee;Kim, Jong-Bae;Shin, Heuyn-Kil
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.856-861
    • /
    • 1988
  • A new method developed for simultaneous purification of enterotoxin A and C from Staphylococcus aureus strain L 350/1 consisted of chromatography on carboxymethyl (CM)-cellulose using a buffer of variable pH, gel filtration on Ultro gel, and fast protein liquid chromatography(FPLC) using a buffer of variable pH. The enterotoxin A and C were purified by three steps: batchwise adsorption from culture supernatant on Amberlite CG-50; chromatography on CM-cellulose using a buffer of constant pH and molarity; and gel filtration on Sephadex G-75. The purified enterotoxin appeared homogeneous by gel diffusion and polyacrylamide gel electrophoresis. Upon treatment with CM-cellulose using a elution of variable pH, enterotoxin A and C were so close that they were not separated completely. After elution from gels, the enterotoxins appeared as a single peak at the same position. Gel filtration gave a reaction of complete identity to enterotoxin A and C in Ouchterlony immunodiffusion. In FPLC using a CM-cellulose, enterotoxin A and C were simultaneously separated at pH 8.6 and 6.8. When each fraction was performed to gel immunodiffusion, at peak of enterotoxin A and C were not detected each other. In a method of elution by pH-gradient was to be more efficient as a simultaneous separation method in terms of speed, yields and simplicity. The purified toxin A and C were identical to type A and C reference enterotoxin on both disc electrophoresis and Ouchterlony gel diffusion.

  • PDF

Increased Sensitivity in Cyanide Measurement by Differential-Pulse Cathodic Stripping Voltammetry (시차펄스 음극벗김 전압전류법에 의한 시안이온 측정의 감도향상)

  • Na, Moon-Son;Kwon, Young-Soon;Czae, Myung-Zoon
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.130-134
    • /
    • 1988
  • Direct differential-pulse cathodic stripping voltammetry on mercury electrode (HMDE) provides a sensitive technique for low level cyanide measurement in distilled and sulfide free solution. Cyclic voltammetry revealed the forming and redissolution reactions were reversible at pH 7 in 0.1M KCl-0.01M phosphate supporting electrolyte. The analytical conditions have been optimized. With deposition time of 3 min at deposition potential 0.00V(vs. Ag/AgCl) in this medium of pH7, quite reproducible and linear calibration curve was obtained down to $3{\times}10^{-7}M$ (8ppb) $CN^-$ which was the detection limit.

  • PDF