• Title/Summary/Keyword: pCR

Search Result 1,869, Processing Time 0.028 seconds

Performance Evaluation of Lab-scale High Rate Coagulation System for CSOs Treatment (강우유출수의 신속한 처리를 위한 고속응집시스템의 성능 평가 -실험실 규모 장치를 중심으로-)

  • Gwon, Eun-Mi;Oh, Seok-Jin;Cho, Seong-Ju;Lee, Seng-Chul;Ha, Sung-Ryong;Lim, Chea-Hoan;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.629-639
    • /
    • 2010
  • To evaluate the performance of high rate coagulation system(HRCS) for CSOs treatment, fundamental function of lab scale HRCS has been tested by using the Jar tester and lab scale HRCS. The optimum pH dose by Streaming Current value was found in the range of 5.3~6.0 in Fe(III), and in the range of 5.8~6.6 in Al(III) and the optimum chemical dose were 0.44mM of $Al_2(SO_4)_3$ and 0.93mM of $FeCl_3$. The removal efficiencies at optimum $Al_2(SO_4)_3$ dose were 75%($TCOD_{Cr}$), 97%(TP), 95%(SS) and 96%(turbidity), respectively. And the removal efficiency of particles with less than $5{\mu}m$ of diameter was 70% and that of particles with higher than $5{\mu}m$ of diameter was 90%. The optimum alum dose in lab scale HRCS was 150mg/L, and the treatment efficiency was the best with addition of 1.0mg/L polymer. The effect of Micro sand addition was not clear, because the depth of the sediment tank in lab scale HRCS was not long enough. But the HRT of this lab scale HRCS was able to be shorten less then 7 minutes by adding the micro sand. The surface loading rates with respect to using different chemicals were 0.43m/h with alum only, 5.78m/h with alum and polymer and 6.22m/h with alum, polymer and micro sand. As a result, HRCS using coagulant, polymer and micro sand developed in this study was evaluated to be very effective for CSOs treatment.

Morphologies of Brazed NiO-YSZ/316 Stainless Steel Using B-Ni2 Brazing Filler Alloy in a Solid Oxide Fuel Cell System

  • Lee, Sung-Kyu;Kang, Kyoung-Hoon;Hong, Hyun-Seon;Woo, Sang-Kook
    • Journal of Powder Materials
    • /
    • v.18 no.5
    • /
    • pp.430-436
    • /
    • 2011
  • Joining of NiO-YSZ to 316 stainless steel was carried out with B-Ni2 brazing alloy (3 wt% Fe, 4.5 wt% Si, 3.2 wt% B, 7 wt% Cr, Ni-balance, m.p. 971-$999^{\circ}C$) to seal the NiO-YSZ anode/316 stainless steel interconnect structure in a SOFC. In the present research, interfacial (chemical) reactions during brazing at the NiO-YSZ/316 stainless steel interconnect were enhanced by the two processing methods, a) addition of an electroless nickel plate to NiO-YSZ as a coating or b) deposition of titanium layer onto NiO-YSZ by magnetron plasma sputtering method, with process variables and procedures optimized during the pre-processing. Brazing was performed in a cold-wall vacuum furnace at $1080^{\circ}C$. Post-brazing interfacial morphologies between NiO-YSZ and 316 stainless steel were examined by SEM and EDS methods. The results indicate that B-Ni2 brazing filler alloy was fused fully during brazing and continuous interfacial layer formation depended on the method of pre-coating NiO-YSZ. The inter-diffusion of elements was promoted by titanium-deposition: the diffusion reaction thickness of the interfacial area was reduced to less than 5 ${\mu}m$ compared to 100 ${\mu}m$ for electroless nickel-deposited NiO-YSZ cermet.

RELATIONSHIPS BETWEEN BITEWING AND PERIAPICAL RADIOGRAPHS IN ASSESSING CRESTAL ALVEOLAR BONE LEVELS (치조골 높이 측정시 표준촬영과 교익촬영의 비교)

  • Cho Yong Jin;Park Tae Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.15 no.1
    • /
    • pp.75-83
    • /
    • 1985
  • Bitewing and periapical radiographic techniques are used in clinical and epidemiological studies to assess crestal alveolar bone levels. The purpose of the present study investigated relationships between these techniques by assessing alveolar crest location at the same site. Bitewing and periapical radiographs were available from posterior quadrants of 120 subjects. The distance from cemento-enamel junction to the alveolar crest (CEJ -CR) was measured for each proximal surface from the distal of the cuspid to the distal of the second molar. Data were arranged according to the proximal surface examined, and bitewing and periapical measurements were compared using paired tests. The obtained results were as follows; 1. In maxilla, a significant t ratio with a P value of 0.05 or less was reached for 78% and in mandible reached for 39%. 2. Pearson correlations were calculated 32 surfaces (89%) had values below 0.70 and so, data obtained by these techniques can not be used interchangeably on an individual or group basis. 3. In situations where the periapical measure was greater than the bitewing, it ranged up to 20.7% greater with a mean 9.8%. Where the bitewing was greater than periapical, it ranged up to 51. 9% greater, with a mean 18.2%. 4. The percentage difference was greater in maxillary posterior areas than in mandibular molar, premolar areas. A lower prevalence of significant differences was attributed to relatively more simple root and favorable radiographic conditions in mandibular molar and premolar areas. 5. The anatomical limitations imposed on periapical radiographic technique, most often result in somewhat foreshortened radiographic images. This situation would tend to be accentuated by the anatomical restrictions of the hard palate. 6. Consequently, since the significant differences frequently exist between measurements obtained from bitewing and periapical techniques, it is important to define which technique is used.

  • PDF

A fiber optic surface plasmon resonance (SPR) sensorusing cyclic olefin copolymer (COC) polymer prism (Cyclic olefin copolymer (COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명 (SPR) 바이오 센서)

  • Yun, Sung-Sik;Lee, Soo-Hyun;Ahn, Chong-H.;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.369-374
    • /
    • 2008
  • A novel fiber optic surface plasmon resonance (SPR) sensor using cyclic olefin copolymer (COC) prism with the spectral modulation is presented. The SPR sensor chip is fabricated using the SU-8 photolithography, Ni-electroplating and COC injection molding process. The sidewall of the COC prism is partially deposited with Au/Cr (45/2.nm thickness) by e-beam evaporator, and the thermal bonding process is conducted for micro fluidic channels and optical fibers alignment. The SPR spectrum for a phosphate buffered saline (0.1.M PBS, pH.7.2) solution shows a distinctive dip at 1300.nm wavelength, which shifts toward longer wavelength with respect to the bovine serum albumin (BSA)concentrations. The sensitivity of the wavelength shift is $1.16\;nm{\cdot}{\mu}g^{-1}{\cdot}{\mu}l^{-1}$. From the wavelength of SPR dips, the refractive indices (RI) of the BSA solutions can be theoretically calculated using Kretchmann configuration, and the change rate of the RI was found to be $2.3{\times}10^{-5}RI{\cdot}{\mu}g^{-1}{\cdot}l^{-1}$. The realized fiber optic SPR sensor with a COC prism has clearly shown the feasibility of a new disposable, low cost and miniaturized SPR biosensor for biochemical molecular analyses.

Absorption analysis of streptavidin-biotin complexes using AFM (AFM을 이용한 스트렙타비딘-바이오틴 단백질 복합체의 흡착 분석)

  • Park, Jee-Eun;Kim, Dong-Sun;Choi, Ho-Jin;Shin, Jang-Kyoo;Kim, Pan-Kyeom;Lim, Geun-Bae
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.237-244
    • /
    • 2006
  • Atomic force microscope (AFM) has become a common tool for the structural and physical studies of biological macromolecules, mainly because it provides the ability to perform experiments with samples in a buffer solution. In this study, structure of proteins and nucleic acids has been studied in their physiological environment that allows native intermolecular complexes to be formed. Cr and Au were deposited on p-Si (100) substrate by thermal evaporation method in sequence with the thickness of $200{\AA}$ and $500{\AA}$, respectively, since Au is adequate for immobilizing biomolecules by forming a self-assembled monolayer (SAM) with semiconductor-based biosensors. The SAM, streptavidin and biotin interacted each other with their specific binding energy and their adsorption was analyzed using the Bio-AFM both in a solution and under air environment. A silicon nitride tip was used as a contact tip of Bio-AFM measurement in a solution and an antimony doped silicon tip as a tapping tip under air environment. Actual morphology could also be obtained by 3-dimensional AFM images. The length and agglomerate size of biomolecules was measured in stages. Furthermore, $R_{a}$ (average of surface roughness) and $R_{ms}$ (mean square of surface roughness) and surface density for the adsorbed surface were also calculated from the AFM image.

A STUDY ON THE MARGINAL LEAKAGE OF CLASS II LIGHT CURING COMPOSITE RESIN RESTORATION ACCORDING TO FILLING METHODS (2급와동 광중합 복합레진의 충전방법에 따른 변연누출에 관한 실험적 연구)

  • Kim, Kyung-Hyun;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.55-72
    • /
    • 1993
  • The aim of this study was to compare the marginal leakage of class II light curing composite resin restoration according to filling methods. With using acid etching technique and dentin bonding agent, various methods were suggested to eliminate or reduce the marginal leakage. In this study, class II cavities were prepared in 100 extracted human premolars with cementum margin(1mm below the CEJ) and the teeth were randomly assigned to 5 groups of 20 teeth each. The teeth in group 1, 2, 3 and 4 were restored by direct filling methods using P-50 and Clearfil Photoposterior of 10 teeth each, but the method of insertion of the restorative materials varied with each group. And the teeth in group 5 were restored by inlay method using Kulzer Inlay and CR Inlay. Filling methods are as follows : Group 1 : The composite resin was inserted in one layer in the proximal box and one layer in the occlusal portion. Group 2 : Insertion was in two equally thick horizontal layers in the proximal box. Group 3 : Insertion was in two diagonally placed layers in the proximal box. Group 4 : The composite resin was inserted in the same way as in group 3 except that a glass ionomer liner was first placed on the axial wall and gingival floor. Group 5 : The teeth were restored by Inlay technique using dure cure resin cement. All the teeth were thermocycled, stained with 1 % methylene blue solution, sectioned mesiodistally, and scored for marginal leakage. To compare the marginal leakage, ANOVA and T-test were used in analysis. The following results were obtained : 1. In direct filling methods, there was no significant difference in marginal leakage at both occlusal and cervical margins. 2. In all groups, occlusal margin showed significantly less leakage than cervical margin. 3. In group using glass ionomer liner, there was no significant reduction of marginal leakage at the cervical margin. 4. The group restored by inlay method showed significantly less marginal leakage than groups restored by direct filling methods at both occlusal and gingival margins. 5. There was no significant difference in each group according to filling materials.

  • PDF

The Molecular Biomarker Genes Expressions of Rearing Species Chironomus riparious and Field Species Chironomus plumosus Exposure to Heavy Metals (실내종 Chironomus riparious와 야외종 Chironomus plumosus의 중금속 노출에 따른 분자지표 유전자 발현)

  • Kim, Won-Seok;Kim, Rosa;Park, Kiyun;Chamilani, Nikapitiya;Kwak, Ihn-Sil
    • Korean Journal of Ecology and Environment
    • /
    • v.48 no.2
    • /
    • pp.86-94
    • /
    • 2015
  • Chironomous is aquatic insect belonging to order Diptera, family Chironomidae. Their larval stage can be found mainly in aquatic benthic environment, hence good model organism to study environmental toxicology assessments and consider as useful bio indicators of contamination of the aquatic environment. In this study, Chironomus Heat Shock Proteins, Cytochrome 450, Glutathione S-transferase, Serine-type endopeptidase gene expressions were compared between polluted field areas (Chironomus plumosus) and under laboratory conditions (Chironomus riparious) to investigate molecular indicators for environmental contaminant stress assessment. Heavy metal (Al, Fe, Mn, Cu, Cr, Zn, Se, Pb, As, Cd) concentrations in sediments collected from three study areas exceeded the reference values. Moreover, HSPs, CYP450 and GST gene expression except SP for C. plumosus showed higher expression than C. riparious gene expression. Similar gene expression pattern was observed in C. riparious that exposed environment waters up to 96 h when compared to C. plumosus exposed to waters that grown in lab conditions. In summary, this comparative gene expression analysis in Chironomous between field and laboratory condition gave useful information to select candidate molecular indicators in heavy metal contaminations in the environment.

A Study on a KTP Crystal Laser System for a Cancer Using P.D.T. (KTP 크리스탈을 이용한 PDT용 레이저 시스템 개발)

  • Kim, Byoung-Mun;Nam, Hyo-Duk;Kim, Byoung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.631-634
    • /
    • 2004
  • The method that exists in Photodynamic Therapy uses Photosensibility drug strongly Influencing tumour accumulation together with photochemical laser effect and makes the structure of tumour be localized and become extinct. The intracavity transformation of the Nd :YAP main radiation 1079 nm was Raman converted in barium nitrate crystal and the Stokes frequency (1216 nm) was doubled using KTP or RTA crystals. The LiF or Cr:YAG crystals are used for the Q-switch. The radiation Parameters were obtained at 100 Hz pump repetition frequency. The average power at 608 nm radiation with LiF and KTP was 700 mW at multi-mode generation. The 3-6 single 10-15 ns pulses were generated during one cycle of pumping. The doubling efficiency with RTA was two times more than with KTP. The cells of Ehrlich adenocarcinoma (0.1 ml) were i.m. implanted in hind thighs of ICR white non-imbred mice. The cells were preliminarily diluted in medium 199 in the ratio of 1 to 5. HpD was intravenous administered in a dose of 10 mg/kg. The left clean-shaven hind leg was irradiated with laser light 21-27 hours after the administration of the preparation. The right non-Irradiated leg of each animal served as a control. The animals with the transplanted tumor that were not injected with HpD sewed as a control to estimate the complex effect (HpD+ irradiation). Before the administration of HpD and on 3 and 4 days after irradiation the tumor size was measured and the percent of the tumor growth inhibition was calculated. The results of animal treatments has shown high efficiency of PDT method for cancer treatment by means 0.608 m high power pulse solid state laser.

  • PDF

Dissemination Effectiveness Analysis of BMP for Paddy field spreading over wide area (논 지역 광역단위 BMP 보급 효과 분석)

  • Shin, Jae Young;Lee, Su In;Jang, Jung Ryeol;Ju, So Hee;Choi, Joong Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.565-565
    • /
    • 2016
  • 농림부는 농업지역에서 발생하는 비점오염원을 관리하기 위해 다양한 최적관리기법(BMP)에 대해 연구를 수행하여 효과를 검증하였으나 이를 광역 단위로 보급하여 실제 영농지역에서 BMP의 효과를 측정한 연구는 부족한 실정이다. 따라서 본 연구에서는 논 지역을 대상으로 물관리기술(물꼬)과 시비관리기술(완효성 비료) BMP를 보급하고 광역 단위로 BMP의 효과를 측정하고자 하였다. 연구대상지구는 새만금 지역에 위치한 전라북도 부안군 용계리 일대에 위치하고 있으며, 벼농사가 활발하게 이루어지고 있는 지역을 선정하였다. 논에 보급된 BMP의 효과를 측정하기 위해 BMP 참여 농가를 선정하여 물꼬와 완효성 비료를 보급하였으며, 용수로와 배출구 3지점을 선정하여 관개량을 측정하고 유출량을 측정하였다. 또한 관개수와 대조구, 처리구별(대조구, 물꼬, 완효성, 물꼬+완효성) 수질을 분석하여 배출구 별로 단위면적당 오염부하량을 산정하고 이를 통해 대조구 대비 처리구의 저감율을 분석하였다. 분석 결과, 대조구 대비 처리구의 단위면적당 오염부하량의 저감율은 SS 63.6%, BOD 45.5%, $COD_{Mn}$ 26.5%, $COD_{Cr}$ 40.1%, T-N 16.0%, T-P 12.9%, TOC 11.4%로 나타났다. 또한 연구대상지구를 SO#1(완효성 비료 95%, 비참여 농가 5%), SO#2(완효성 비료 2%, 물꼬 8%, 완효성 비료+물꼬 40%, 비참여 농가 40%), SO#M(완효성 비료 96%, 비참여 농가 4%) 3개의 배출구로 구분하여 BMP 보급 효과를 측정한 결과, 대조구 대비 SO#1에서는 수질항목별로 10.6 ~ 85.5%, SO#2는 8.1 ~ 45.9%, SO#M은 10.7 ~ 86.2%의 범위로 저감된 것으로 분석되었으며, 특히 SS의 단위면적당 오염부하 저감율이 가장 큰 것으로 나타났다. 하지만 본 연구는 7월부터 10월까지 측정된 데이터를 활용하여 산정하였기 때문에 써레질, 이앙기간에 발생한 단위면적당 오염부하량은 포함되지 않은 결과이며, 각 배수구역별 유입량의 경우 정확한 측정에 어려움이 있어 전체 관개량 대비 관개 면적을 이용하여 단위면적당 유입량을 산정하였기 때문에 추가적인 연구를 통해 효과를 검증할 필요가 있을 것으로 판단된다.

  • PDF

Chemical Composition and Heavy Metal Contents in Commercial Liquid Pig Manures (국내유통 돈분액비의 화학성 및 중금속 함량)

  • Lee, Ji-Ho;Go, Woo-Ri;Kunhikrishnan, Anitha;Yoo, Ji-Hyock;Kim, Ji-Young;Kim, Won-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1085-1088
    • /
    • 2011
  • Heavy metal concentration as well as chemical composition were surveyed in commercial liquid pig manure to provide the basic information for mitigation research of hazardous material to agro-product. Seventy-five samples of liquid pig manure were collected and analyzed from 2009 to 2010 nationwide. Average contents of T-N, $P_2O_5$, and $K_2O$ were 0.29%, 0.08%, and 0.11%, respectively. The contents of heavy metals ranged from 0.001~0.083 for As, 0.001~0.108 for Cd, 0.002~0.495 for Cr, 0.07~47.8 for Cu, ND~0.005 for Hg, 0.035~1.033 for Ni, ND~0.291 for Pb, and $0.75{\sim}342.4mg\;L^{-1}$ for Zn, respectively. It was noted that among 75 samples, only four samples exceeded the Zn guideline ($130mg\;L^{-1}$) of liquid fertilizer derived from livestock manure but others were not exceeded the regulation.