• 제목/요약/키워드: pCR

검색결과 1,873건 처리시간 0.032초

Gap comparison between single crown and three-unit bridge zirconia substructures

  • Anunmana, Chuchai;Charoenchitt, Masnisa;Asvanund, Chanavut
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.253-258
    • /
    • 2014
  • PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three-unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using $Lava^{TM}$ system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The $mean{\pm}SD$ of marginal gap in premolar was $43.6{\pm}0.4{\mu}m$ and $46.5{\pm}0.5{\mu}m$ for single crown and 3-unit bridge substructure respectively. For molar substructure the $mean{\pm}SD$ of marginal gap was $48.5{\pm}0.4{\mu}m$ and $52.6{\pm}0.4{\mu}m$ for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was $150.5{\pm}0.5{\mu}m$ and $154.5{\pm}0.4{\mu}m$ for single and 3-unit bridge premolar substructures respectively and $146.5{\pm}0.4{\mu}m$ and $211.5{\pm}0.4{\mu}m$ for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAM technique especially at the occlusal area.

Influence of Serum VEGF Levels on Therapeutic Outcome and Diagnosis/Prognostic Value in Patients with Cervical Cancer

  • Du, Ke;Gong, Hong-Ying;Gong, Zhi-Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권20호
    • /
    • pp.8793-8796
    • /
    • 2014
  • Objective: To explore the influence of serum vascular endothelial growth factor (VEGF) level on therapeutic outcome and diagnosis/prognostic value in patients with cervical cancer. Materials and Methods: A total of 37 patients diagnosed with cervical cancer by biopsy were selected and treated with concurrent chemoradiotherapy. Double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) was adopted before treatment to assess VEGF levels, and its relationships with clinicopathological features and short-term therapeutic effects were analyzed. Results: The median VEGF level in 37 patients before treatment was 647.15 (393.35~1125.16) pg/mL. Serum VEGF levels in patients aged <50 years, in International Federation of Gynecology and Obstetrics (FIGO) stage IIIa~IVa, with lymph node metastasis and tumor size >4 cm were significantly increased (P<0.05). The complete remission (CR) rate was 48.7% (18/37), partial remission (PR) rate was 35.1% (13/37), stable disease (SD) rate was 13.5% (5/37) and progressive disease (PD) rate was 2.70% (1/37), so the objective remission rate (ORR) after treatment was 83.8% (31/37). Logistic regression analysis showed that tumor size and serum VEGF level before treatment were independent risk factors affecting the therapeutic outcome, and the higher the level of serum VEGF, the worse the prognosis when tumor size>4 cm. Some 56.8% of patients manifested with myelosuppression, 37.8% with leucopenia, 24.3% with thrombocytopenia, 5.41% with diarrhea, 46.0% with nausea and vomiting, 21.6% with hair loss and 8.11% with hepatic and renal injury during the treatment. Conclusions: Serum VEGF level may reflect the degree of malignancy of cervical cancer and predict therapeutic effect, which is of great importance to cancer diagnosis and prognosis.

Inflammatory Breast Cancer in Tunisia from 2005 to 2010: Epidemiologic and Anatomoclinical Transitions from Published Data

  • Mejri, N.;Boussen, H.;Labidi, S.;Bouzaiene, H.;Afrit, M.;Benna, F.;Rahal, K.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권3호
    • /
    • pp.1277-1280
    • /
    • 2015
  • Aim: To report epidemiologic and anatomoclinical transitions of inflammatory breast cancer (IBC) in Tunisia. Materials and Methods: Data including clinico-pathological data for 208 cases of T4d or PEV 3 non-metastatic breast cancer diagnosed between 2005 and 2010 were collected from patient records. Chi2 and Z tests were used to compare variables with two Tunisian historical series and a series about Arab-American patients. Results: Thirty three percent of our patients had their first child before 23 years of age and 56% had their menarche before 12 years, 75% never receiving oral contraception. Obesity was observed in 42% of women and IBC occurred during pregnancy in 13% of cases. Tumor grade was II-III in 90% of cases, HR was negative in 52%, HER2 was over expressed in 31% and invasion of more than 3 axillary nodes occurred in 18% of patients. We observed a pCR rate of 19% after neoadjuvant treatment (anthracyline-taxane used in 79%, trastuzumab in 27% ). Compared to historical Tunisian series (since 1996), IBC epidemiology remained stable in terms of median age, menopausal status and obesity. However we observed a significant decrease in median clinical tumor size and number of positive axillary lymph nodes. Comparison to IBC in Arab-Americans showed a significant difference in terms of median age, menopausal status, positivity of hormonal receptors and educational level. Conclusions: Our assessment of epidemiologic transition showed a reduction of clinco-pathological stage of IBC, keeping the same characteristics as compared to Tunisian historical series over a period of 14 years. Features seem to be different in Arab-American patients, probably related to migration, "occidentalization" of life style and improvement in socio-economic level.

TIG용접한 저방사화 페라이트강(JLF-1)의 고온강도 및 피로수명특성 (High Fatigue Life and Tensile Strength Characteristics of Low Activation Ferritic Steel(JLE-1) by TIG Welding)

  • 윤한기;이상필;김사웅;박원조
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.181-186
    • /
    • 2001
  • JLF-1 steel (Fe-9Cr-2W-V-Ta), low activation ferritic steel, is one of the promising candidate materials fer fusion reactor applications. High temperature fatigue life and tensile strength of JLF-1 steel and its TIG welded joints were investigated at the room temperature and $400^{\circ}C$. The strength of base metal (JLF-1) is in between those of weld metal and the HAZ. When the test temperature was increased from room temperature to $400^{\circ}C$, both strength and ductility decreased for base metal, weld metal and the HAZ. The longitudinal specimens of base metal showed similar strength and ductility compared with those of the transverse specimens at room temperature and $400^{\circ}C$. Little anisotropy was observed in the JLF-1 steel base metal in terms of rolling direction. Fatigue limit of weld metal which was obtained from cross-weld specimen is 495MPa. Thus, the weld metal showed the higher fatigue limit than those of base metal at both room temperature and $400^{\circ}C$. Little anisotropy of fatigue properties was observed for JLF-1 base metal in terms of rolling direction. When the test temperature was increased from room temperature to $400^{\circ}C$, the fatigue limit of both base metal and weld metal decreased substantially.

  • PDF

우리 나라 황토(풍화토)의 구성광물 및 화학성분 (Mineralogy and Chemical Composition of the Residual Soils (Hwangto) from South Korea)

  • 황진연;장명익;김준식;조원모;안병석;강수원
    • 한국광물학회지
    • /
    • 제13권3호
    • /
    • pp.147-163
    • /
    • 2000
  • The mineralogy and chemical composition of reddish to brownish yellow residual soils, so called "Hwangto" have been examined according to representative host rocks. The result of the study indicates that Hwangto consists of 40-80% clay minerals and various minerals such as quartz, feldspar, hornblende, goethite, and gibbsite. Clay minerals include kaolinite, halloysite, illite, hydroxy interlayered vermiculite (HIV), mica/vermiculite interstratifield mineral and chlorite. The mineralogical constituents and contents of Hwangto were different depending on the types of host rocks. Moreover, the Jurassic granitic rocks contain relatively more kaolin minerals, whereas the Cretaceous granitic rocks contain more HIV and illite. In addition, reddish Hwangto contains relatively more kaolinite and HIV, and yellowish Hwangto contains more illite and halloysite. It is suggested that feldspars and micas of host rocks were chemically weathered into illite, halloysite, illite/vermiculite interstratified minerals, and HIV, and finally into kaolinite. Compared with their host rocks, the major chemical compositions of Hwangto tend to contain more $Al_2O_3,\;Fe_2O_3,\;H_2O$ in amount and less Ca, Mg, and Na. Hwangto contains relatively high amount of trace elements, P, S, Zr, Sr, Ba, Rb, and Ce including considerable amount of Li, V, Cr, Zn, Co, Ni, Cu, Y, Nb, La, Nd, Pb, Th in excess of 10 ppm. Relatively high amount of most trace elements were detected in the Hwangto. The major and minor chemical compositions of the Hwangto were different depending on the types of host rocks. However, their difference was in the similar range compared with the compositions of host rocks.

  • PDF

고성능 액체크로마토그래피를 이용한 식이보충제에서 크레아틴, 디시안디아마이드, 디하이드로트리아진의 동시분석 (Simultaneous Determination of Creatine, Dicyandiamide and Dihydrotriazine in Dietary Supplements by High Performance Liquid Chromatography)

  • 박상욱;유명상;이원재
    • KSBB Journal
    • /
    • 제29권4호
    • /
    • pp.232-238
    • /
    • 2014
  • The simultaneous determination of creatine monohydrate (CrM), dicyandiamide and dihydrotriazine in dietary supplements using reversed-phase high performance liquid chromatography (HPLC) was developed. Chromatography was performed on a Nuclosil 100-5 SA ($4.6{\times}250mm$) column with a mobile phase of 2.3% ammonium phosphate (pH 5.5), and UV detection at 224 nm, 212 nm, and 237 nm, respectively. The performance characteristics of HPLC were determined in terms of selectivity, linearity, precision, recovery, limit of detection (LOD), and limit of quantification (LOQ). The calibration curves were linear within the concentration range of $40.0{\sim}500.0{\mu}g/mL$ for creatine, $0.1{\sim}12.8{\mu}g/mL$ for dicyandiamide, and $0.05{\sim}6.4{\mu}g/mL$ for dihydrotriazine. The detection limits of the method were 1.09, 0.01, and $0.08{\mu}g/mL$ for creatine, dicyandiamide, and dihydrotriazine, respectively. The recoveries of creatine, dicyandiamide, and dihydrotriazine were 97.2~100.9, 92.3~106.5, and 97.2~105.5%, respectively. It is expected that the chromatographic analytical method developed in this study will be usefully applicable to simultaneous determination of creatine, dicyandiamide, and dihydrotriazine contained in dietary supplements.

전라북도 서부 해안지역과 동부 산악지역 농업용 지하수 수질 평가 (Water Quality of Agricultural Groundwater in Western Coast Area and Eastern Mountain Area of Jeollabuk-do)

  • 조재영
    • Journal of Applied Biological Chemistry
    • /
    • 제54권3호
    • /
    • pp.218-224
    • /
    • 2011
  • 전라북도 서부해안지역(부안군)과 동부 산악지역(진안군, 장수군, 순창군)을 대상으로 328 지점의 농업용 지하수 수질특성을 비교 검토하였다. 조사항목은 지하수법에서 규정하고 있는 농업용수 관리항목인 일반오염물질 4개 항목과 특정유해물질 10개 항목이었다. 전라북도 서부 해안지역에서 일반오염물질의 일종인 염소이온이 기준치를 초과한 지점이 나타났으나, 모든 조사지점에서 농업용 지하수 수질기준을 충족하였다. 특정유해 물질은 거의 모든 조사지점에서 검출한계미만 또는 자연함유량 수준으로 검출되어 안전성이 확보되었다. 농업활동이 활발하고 논과 밭의 경지면적이 상대적으로 넓은 해안 인접 평야지가 중 산간지대 보다 농업용 지하수중 오염물질의 농도가 더 높게 나타나는 경향이었다.

Hyper Duplex STS 중 Ce 첨가 시 비금속개재물 생성거동 (The Formation Behavior of Non-metallic Inclusion in the Ce-added Hyper Duplex STS)

  • 홍성훈;장필용;박영민;변선민;김광태;유병돈
    • 소성∙가공
    • /
    • 제19권5호
    • /
    • pp.311-319
    • /
    • 2010
  • Rare earth metal Ce has a relatively low melting point and high specific gravity. Because of its significantly high affinity to oxygen, nitrogen and sulfur, it is highly usable as a steel refining agent. However, because Ce compound has relatively high specific gravity, it is difficult to be separated from molten steel through floatation, and it degrades the purity of molten steel, or may clog the nozzle in continuous casting. Such problem may be solved by using an appropriate deoxidation agent together with Ce and settling molten steel sufficiently after refining. Thus a fundamental study in the formation behavior of non-metallic inclusion in Ce added Hyper Duplex STS melts was investigated. The addition amount of Ce, melt temperature were considered as experimental variables. A main non-metallic inclusion in mother alloy is 51(wt%MnO) - 27.6(wt%SiO$_2$)- 10.9(wt%$Cr_2O_3$). Non-metallic inclusion was dramatically decreased and the particle size was fined as the amount of Ce increased. Moreover (%MnO) and (%SiO$_2$) of non-metallic inclusion were decreased. But (%$Al_2O_3$)were relatively increased. The number of non-metallic inclusion were decreased and the large particle size were increased by increasing the temperature of molten steel.

Demonstration of Nonpolar a-plane Light Emitting Diodes on r-plane Sapphire Substrate by MOCVD

  • Son, Ji-Su;Baik, Kwang-Hyeon;Song, Hoo-Young;Kim, Ji-Hoon;Kim, Tae-Geun;Hwang, Sung-Min
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.147-147
    • /
    • 2011
  • High crystalline nonpolar a-plane (11-20) nitride light emitting diodes (LEDs) have been fabricated on r-plane (1-102) sapphire substrates by metalorganic chemical-vapor deposition (MOCVD). The multi-quantum wells (MQWs) active region is consists of 4 periods the nonpolar a-plane InGaN/GaN(a-InGaN/GaN) on a high quality a-plane GaN (a-GaN) template grown by using the multibuffer layer technique. The full widths at half maximum (FWHMs) of x-ray rocking curve (XRC) obtained from phiscan of the specimen that was grown up to nonpolar a-plane GaN LED layers with double crystal x-ray diffraction. The FWHM values were decreased down to 477 arc sec for $0^{\circ}$ and 505 arc sec for $-90^{\circ}$, respectively. After fabricating a conventional lateral LED chip which size was $300{\times}600{\mu}m^2$, we measured the optical output power by on-wafer measurements. N-electrode was made with Cr/Au contact, and ITO on p-GaN was formed with Ohmic contact using Ni/Au followed by inductively coupled plasma etching for mesa isolation. The optical output power of 1.08 mW was obtained at drive current of 20 mA with the peak emission wavelength of 502 nm.

  • PDF

수복에 따른 구치부 복합레진 수복물의 변연부 미세누출 및 적합도 (MICROLEAKAGE AND MARGINAL ADAPTATION OF POSTERIOR COMPOSITE RESIN RESTORATIONS ACCORDING TO RESTORATIVE TECHNIQUE)

  • 양인서;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.334-346
    • /
    • 1997
  • Incidence of using esthetic composite resin in the posterior area is increasing but there were lots of inconsistent reports about their microleakage and marginal adaptation. The purpose of this study was to evaluate the differences of microleakage and marginal adaptation according to restorative techniques. 30 cavities with enamel gingival margin were prepared and restored with 3 types of composite resin [Z-100($Scotchbond^{TM}$ MP), AELITEFIL ($Onestep^{TM}$), Her culite XRV(Fuji BOND LC)] in direct technique and another 30 cavities were restored with preformed CR inlays and 3 different modern resin and resin-modified GI cements (Superbond C&B, Choice, Fuji Duet). Samples were chemically stressed in 75% ethanol for 24 hours and were thermocycled (5-$55^{\circ}C$(500 times. The degree of microleakage through proximal and gingival margins was examined by 1 % MB dye and the degree of marginal adaptation by examining the margins via SEM. The following results were obtained ; 1. In direct groups, Herculite XRV [Fuji BOND LC, 35.13 (15.50) %] group showed statistically different, less microleakage than Z-100 [$Scotchbond^{TM}$ MP, 72.91 (16.91 %] group and AELITEFIL [One-step, 93.73 (13.66) %] group (p<0.05). 2. In indirect groups, the degree of microleakage in Mean(S.D.) were: Super bond C & B [39.00 (24.35) %], Choice [57.19 (33.80) %], Fuji Duet [58.22 (40.36) %]. But there was no significant difference. 3. There was no significant difference between resin cement and resin-modified GI cement. 4. There were gaps at the interface with the tooth structure, but no gap was seen at the interface with restoration in all specimens. 5. In direct groups, Herculite XRV(Fuji BOND LC) group made little gap compared with other groups, but 40-$50{\mu}m$ thickness of bonding agent, Fuji BOND LC, looked like a cement used in indirect technique. 6. All indirect groups showed a variety of cement thickness, from less than $20{\mu}m$ to over $100{\mu}m$ and that dimension of buccal/lingual margin was less than that of gingival margin.

  • PDF