• 제목/요약/키워드: pCR

검색결과 1,869건 처리시간 0.028초

Adsorption Characteristics of Multi-Metal Ions by Red Mud, Zeolite, Limestone, and Oyster Shell

  • Shin, Woo-Seok;Kang, Ku;Kim, Young-Kee
    • Environmental Engineering Research
    • /
    • 제19권1호
    • /
    • pp.15-22
    • /
    • 2014
  • In this study, the performances of various adsorbents-red mud, zeolite, limestone, and oyster shell-were investigated for the adsorption of multi-metal ions ($Cr^{3+}$, $Ni^{2+}$, $Cu^{2+}$, $Zn^{2+}$, $As^{3+}$, $Cd^{2+}$, and $Pb^{2+}$) from aqueous solutions. The result of scanning electron microscopy analyses indicated that the some metal ions were adsorbed onto the surface of the media. Moreover, Fourier transform infrared spectroscopy analysis showed that the Si(Al)-O bond (red mud and zeolite) and C-O bond (limestone and oyster shell) might be involved in heavy metal adsorption. The changes in the pH of the aqueous solutions upon applying adsorbents were investigated and the adsorption kinetics of the metal ions on different adsorbents were simulated by pseudo-first-order and pseudo-second-order models. The sorption process was relatively fast and equilibrium was reached after about 60 min of contact (except for $As^{3+}$). From the maximum capacity of the adsorption kinetic model, the removal of $Pb^{2+}$ and $Cu^{2+}$ were higher than for the other metal ions. Meanwhile, the reaction rate constants ($k_{1,2}$) indicated the slowest sorption in $As^{3+}$. The adsorption mechanisms of heavy metal ions were not only surface adsorption and ion exchange, but also surface precipitation. Based on the metal ions' adsorption efficiencies, red mud was found to be the most efficient of all the tested adsorbents. In addition, impurities in seawater did not lead to a significant decrease in the adsorption performance. It is concluded that red mud is a more economic high-performance alternative than the other tested adsorption materials for applying a removal of multi-metal in seawater.

컬럼식 연속추출장치에 의한 산세폐액중 Ni의 회수 (Recovery of Nickel from Waste Pickling Solution with Column Extractor)

  • 김성규;이화영;오종기
    • 자원리싸이클링
    • /
    • 제7권1호
    • /
    • pp.27-33
    • /
    • 1998
  • 유리질산 및 불산이 제거된 산세폐액으로부터 Ni을 회수하기 위하여 컬럼식 연속추출장치에 의한 연속실험을 수행하였다. 먼저 Ni 회수 실험에 앞서 폐액중 다량 함유되어 있는 Fe나 Cr을 효과적으로 침전 제거하기 위해서는 중화제로 $CaCO_3$가 적절하며 이대 Ni은 전혀 침전되지 않는다. 한편 컬럼식 연속추출장치에 의한 No의 추출특성을 살펴보면 pulse velosity(Amplitude$\times$Frequency)가 증가함에 따라 수상과 유기상의 혼합효과가 증대되어 Ni의 추출율이 높아지고 이에 딸 HETS도 감소하고 있으나, pulse velosity가 임계치 이상으로 증가하게 되면 수상과 유기상의 강력한 혼합에 의해 원판과 원판사이에 분리층이 형성되지 못하고 컬럼 전체가 완전한 혼합 형태로 되어 추출율이 낮아지고 HETS도 길어지게 된다. 유기상에 추출된 Ni은 탈거시 탈거액으로 2M ${H}_{2}{SO}_{4}$액을 사용하면 효과적으로 농축 회수할 수 있다. 그리고 ${H}_{2}{SO}_{4}$용액중 $NiSO_4$의 용해도는 ${H}_{2}{SO}_{4}$ 농도가 증가함에 따라 감소하여 2M ${H}_{2}{SO}_{4}$ 용액에서는 55 gr/$\ell$ 정도로 나타나고 있으며, 이같은 $NiSO_4$의 과포화특성을 이용하면 탈거액의 증발과정을 거치지 않고 $NiSO_4$결정을 얻을 수 있다.

  • PDF

규사광산 지역의 강우시 비점오염원의 유출분석 (Analysis of NPS Pollution Loads over Rainfall-Runoff Events from the Silica Mine Site)

  • 최용훈;원철희;서지연;신민환;양희정;최중대
    • 한국물환경학회지
    • /
    • 제26권3호
    • /
    • pp.413-419
    • /
    • 2010
  • A silica mine monitoring was conducted from March to December in 2008 to measure rainfall, runoff amounts and pollution loads. A total of 13 rainfall-runoff events were measured and analyzed with respect to runoff ratio, pollutant concentration and load, and initial flush. Over rainfall-runoff events, 95% confidence range of SS concentration was 942.5~2,056.2 mg/L. Other measured water quality indices also showed relatively large variation. This wide concentration variation was thought to be caused by the bare working ground of the mine that was used to store, process and transport the mined silica. Total pollution load of the 13 rainfall-runoff events was SS 17,901 kg/ha, $COD_{Cr}$ 160.9 kg/ha, $COD_{Mn}$ 111.24 kg/ha, BOD 79.6 kg/ha, T-N 13.8 kg/ha, T-P 3.5 kg/ha, and TOC 39.3 kg/ha. Initial flush was not well observed except SS. Very high SS concentration and load was occurred when rainfall was large. Therefore, it was recommended to manage the bare ground not to discharge excessive pollutants during wet days by covering the ground or constructing runoff treatment systems such as a sediment basin.

원적외선 방사체 시설 내에 저장한 오이, 호박, 방울토마토의 선도유지효과

  • 정준호;조성환
    • 한국식품저장유통학회:학술대회논문집
    • /
    • 한국식품저장유통학회 2003년도 춘계총회 및 제22차 학술발표회
    • /
    • pp.134.2-135
    • /
    • 2003
  • 채소류는 생리적인 특성상 수확후 저장 및 유통되는 동안에 호흡작용, 증산작용 등의 작용이 활발해질 뿐만 아니라 곰팡이를 비롯한 식물병이 미생물의 오염 및 성장으로 부패현상을 일으키고 채소류 자체의 경도가 저하되며, 수분, 비타민, 유기산, 당분, 색소함량 등이 떨어져서 외관, 맛 신선도 등의 감소하게 된다. 본 연구에서는 채소류(오이, 호박, 방울토마토)의 선도를 연장하기 위한 저장조건을 실시하여 최적 습도 및 온도범위를 결정하였고, 이를 토대로 하여 시설채소산물을 습도조절이 가능한 원적외선 방사체 저장고(5~8$^{\circ}C$의 온도와 90% 습도유지)에 저장하면서 무처리구인 대조구와 비교하여 저장중 시료의 중량손실율, Ascorbic acid함량, 총균수(PCA사용법에 의거), pH의 변화를 측정하였고, 시료의 표면색도는 색도계(Minolta CR-300, Japan)를 사용하여 Hunter의 L, a, b값을 측정하였다. 이 결과, 채소류의 선도유지기간이 연장되는 것을 확인하였고, 중량손실율은 원적외선 방사체 저장고에 저장한 채소류가 중량손실율이 대조구에 비하여 낮게 나타났다. 따라서 습도조절이 가능한 원적외선 방사체 저장고에 채소류를 저장함으로서 채소류의 수분손실을 방지할 수 있음을 확인할 수 있었으며, 일정기간동안 원적외선 방사체 저장고에 저장함으로써 ascorbic acid함량의 감소를 대조구에 비하여 낮은 비율로 억제할 수 있었다. 총균수의 경우 채소류 시험구에서 원적외선 방사체 저장고에서 저장할수록 오염미생물의 총균수가 낮게 나타났다. 표면색도의 경우, a값은 모든 시험구에서 감소하였으며 원적외선 방사체 시험구에 비하여 대조구 저장시료의 표면색도가 청색도를 증가시키는 변화를 관찰할 수 있었고, b값은 시료간에 유의성 있는 차이없이 다소 증가하는 것으로 나타났다. 부패율은 수분 함유율이 높은 채소류일수록 원적외선 방사체 저장시설을 이용하는 경우, 부패율을 낮게 유지할 수 있었다. 따라서, 원적외선 방사체 저장시설내에 오이, 호박 및 방울토마토와 같은 채소류를 저온고습도상에서 저장할 경우, 채소류의 품질변화를 최소화 할 수 있어 갓 수확한 채소류의 선도유지기간을 연장할 수 있는 저장법이 될 수 있음을 확인하였다.

  • PDF

Predictive Value of Serum Insulin-like Growth Factor-1 in Hepatocellular Carcinoma

  • Elmashad, Nehal;Ibrahim, Wesam Salah;Mayah, Wael Wahid;Farouk, Mohamed;AboAli, Lobna;Taha, Atef;Elmashad, Wael
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권2호
    • /
    • pp.613-619
    • /
    • 2015
  • Background: Hepatocellular carcinoma (HCC) is the commonest primary malignant cancer of the liver in the world. Insulin-like growth factor-1 (IGF-1) levels reflect hepatic function and are inversely correlated with the severity of background chronic liver disease. Objective: This study evaluated whether basal serum IGF-1 levels can predict prognosis of HCC patients according to different risks of disease progression. Materials and Methods: A total of 89 patients with hepatocellular carcinoma (HCC) were recruited in 3 groups: Group I, 30 HCC patients receiving sorafinib; Group II, 30 HCC patients with best supportive care; and Group III include 29 patients undergoing transcatheter arterial chemoembolization (TACE). All patients were investigated for serum levels of AST, ALP, Bb, Cr, BUN, AFP and IGF-I. Results: Patients with disease control had significantly higher baseline IGF-1 levels 210 (185-232.5) ng/mL (p value<0.01) than did patients without disease control. Low basal IGF-1 levels were associated with advanced HCC, such as multiple tumors and advanced stage, and low IGF-1 levels predicted shorter TTP and overall survival in patients treated with TACE. Conclusions: The levels of serum IGF-1, expressed as continuous values, may be helpful for accurately assessing hepatic function and the prognostic stratification of patients with HCC.

In vitro study of fracture strength of provisional crown materials

  • Karaokutan, Isil;Sayin, Gulsum;Kara, Ozlem
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.27-31
    • /
    • 2015
  • PURPOSE. The purpose of this report was to evaluate the effect of the fabrication method and material type on the fracture strength of provisional crowns. MATERIALS AND METHODS. A master model with one crown (maxillary left second premolar) was manufactured from Cr-Co alloy. The master model was scanned, and the data set was transferred to a CAD/CAM unit (Yenamak D50, Yenadent Ltd, Istanbul, Turkey) for the Cercon Base group. For the other groups, temporary crowns were produced by direct fabrication methods (Imident, Temdent, Structur Premium, Takilon, Systemp c&b II, and Acrytemp). The specimens were subjected to water storage at $37^{\circ}C$ for 24 hours, and then they were thermocycled (TC, $5000{\times}$, $5-55^{\circ}C$) (n=10). The maximum force at fracture (Fmax) was measured in a universal test machine at 1 mm/min. Data was analyzed by non-parametric statistics (${\alpha}$=.05). RESULTS. Fmax values varied between 711.09-1392.1 N. In the PMMA groups, Takilon showed the lowest values (711.09 N), and Cercon Base showed the highest values (959.59 N). In the composite groups, Structur Premium showed the highest values (1392.1 N), and Acrytemp showed the lowest values (910.05 N). The composite groups showed significantly higher values than the PMMA groups (P=.01). CONCLUSION. Composite-based materials showed significantly higher fracture strengths than PMMA-based materials. The CADCAM technique offers more advantages than the direct technique.

The effect of thermocycling on the bonding of different restorative materials to access opening through porcelain fused to metal restorations

  • Al-Moaleem, Mohammed M.;Shah, Farhan Khalid;Khan, Nausheen Saied;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.186-189
    • /
    • 2011
  • PURPOSE. Porcelain fused to metal (PFM) crowns provide the best treatment option for teeth that have a large or defective restoration. More than 20% of teeth with PFM crowns or bridges require non-surgical root canal treatment (NSRCT). This may be due to the effect of restorative procedures and the possible leakage of bacteria and or their by-products, which leads to the demise of the tooth pulp. Thus, this study was planned to compare the ability of the restorative materials to seal perforated PFM specimens. MATERIALS AND METHODS. The study evaluates the ability of amalgam, composite or compomer restorative materials to close perforated PFM specimen's in-vitro. Ninety PFM specimens were constructed using Ni-Cr alloys and feldspathic porcelain, and then they were divided into 3 groups: amalgam (A), composite + Exite adhesive bond (B) and compomer + Syntac adhesive bond (C). All the PFM samples were embedded in an acrylic block to provide complete sealing of the hole from the bottom side. After the aging period, each group was further divided into 3 equal subgroups according to the thermocycling period (one week for 70 cycles, one month for 300 cycles and three months for 900 cycles). Each subgroup was put into containers containing dye (Pelikan INK), one maintained at $5^{\circ}C$ and the other at $55^{\circ}C$, each cycle for 30 sec time. The data obtained was analyzed by SPSS, 2006 using one way ANOVA test and student t-test and significant difference level at (P<.01). RESULTS. The depth of dye penetration was measured at the interfaces of PFM and filling materials using Co-ordinate Vernier Microscope. The lowest levels of the dye penetration for the three groups, as well as subgroups were during the first week. The values of dye leakage had significantly increased by time intervals in subgroups A and C. CONCLUSION. It was seen that amalgam showed higher leakage than composite while compomer showed the lowest level of leakage.

Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas

  • Yus, Estefania Aranda;Cantarell, Josep Maria Anglada;Alonso, Antonio Minarro
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.236-244
    • /
    • 2018
  • PURPOSE. To determine the discrepancy in monolithic zirconium dioxide crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems by comparing scans of silicone impressions and of master casts. MATERIALS AND METHODS. From a Cr-Co master die of a first upper left molar, 30 silicone impressions were taken. The 30 silicone impressions were scanned with the laboratory scanner, thus obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the silicone group). They were poured and the working models were scanned, obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the plaster group). Three predetermined points were analyzed in each side of the crown (Mesial, Distal, Vestibular and Palatal), and the marginal fit was evaluated with SEM (${\times}600$). The response variable is the discrepancy from the master model. A repeated measures ANOVA with two within subject factors was performed to study significance of main factors and interaction. RESULTS. Mean marginal discrepancy was $22.42{\pm}35.65{\mu}m$ in the silicone group and $8.94{\pm}14.69{\mu}m$ in the plaster group. The statistical analysis showed significant differences between the two groups and also among the four aspects. Interaction was also significant (P=.02). CONCLUSION. The mean marginal fit values of the two groups were within the clinically acceptable values. Significant differences were found between the groups according to the aspects studied. Various factors influenced the accuracy of digitizing, such as the design, the geometry, and the preparation guidance, as well as the texture, roughness and the color of the scanned material.

Myocardial Function and Metabolic Energetics in Low Flow Ischemia and with $\beta$-Adrenergic Stimulation in Spontaneously Hypertensive Rat Hearts

  • Kang, Young-Hee;Kang, Jung-Sook;Park, Han-Yoon
    • Preventive Nutrition and Food Science
    • /
    • 제6권1호
    • /
    • pp.43-50
    • /
    • 2001
  • The effects of cardiac ischemia-reperfusion and $\beta$-adrenergic stimulation on metabolic function and energetics were investigated in Lan gendorff-perfused spontaneously hypertensive rat (SHR) hearts. Sarcoplasmic reticulum {TEX}$Ca^{2+}${/TEX}-dependent ATPase and cardiac lactate dehydrogenase (LDH) are additionally studied. The perfusion medium (1.0 mM {TEX}$Ca^{2+}${/TEX}) contained 5 mM glucose(+5 U/L insulin) and 2 mM pyruvate as substrates. Global ischemia was induced by reducing perfusion pressure of 100 to 40 cm {TEX}$H_{2}${/TEX}O, followed by 20 min reperfusin. Isoproterenol (ISO, 1$\mu$M) was infused for 10 min. Coronary vascular resistance and myocardial oxygen consumption ({TEX}$MVO_{2}${/TEX}) of SHR were increased in parallel with enhanced venous lactate during ischemia and reperfusion compared to those of Sprague Dawley (SD) hearts. Although ischemia-induced increase in venous lactate and combined adenosine plus inosine was abolished, coronary vasodilation produced in SD during reperfusion. In SHR, depressed reactive hyperemia was associated with a fall in cardiac ATP and CrP/Pi ratio and a rise in intracellular lactate/Pyruvate ratio. On the other hand, ISO produced coronary functional hyperemia and an increase in {TEX}$MVO_{2}${/TEX}. However, these responses were less than those in SHR hearts. The ATPase activity of SHR was attenuated in free {TEX}$Ca^{2+}${/TEX} concentrations used under basal condition and with ISO compared to that of SD. Venous lactate output and cardiac LDH activity were augmented in SHR as influenced by ISO. These results demonstrate that coronary reactive and functional hyperemia was dpressed in SHR, which cold be explained by alterations in the cytosolic phosphorylation potential and the cytosolic redox state manipulated by LDH, and by abnormal free calcium handling.

  • PDF

Microshear bond strength according to dentin cleansing methods before recementation

  • Tasar, Simge;Ulusoy, Mutahhar Muhammed;Meric, Gokce
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.79-87
    • /
    • 2014
  • PURPOSE. The aim of this study was to determine the efficiency of Erbium, Chromium: Yttrium-Scandium-Gallium-Garnet laser in different output powers for removing permanent resin cement residues and therefore its influence on microshear bond strength compared to other cleaning methods. MATERIALS AND METHODS. 90 extracted human molars were sectioned in 1 mm thickness. Resin cement was applied to surface of sliced teeth. After the removal of initial cement, 6 test groups were prepared by various dentin surface treatment methods as follows: no treatment (Group 1), ethylene diamine tetra acetic acid application (Group 2), Endosolv R application (Group 3), 1.25 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 4), 2 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 5) and 3.5 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 6). The topography and morphology of the treated dentin surfaces were investigated by scanning electron microscopy (n=2 for each group). Following the repetitive cementation, microshear bond strength between dentin and cement (n=26 in per group) were measured with universal testing machine and the data were analyzed by Kruskal Wallis H Test with Bonferroni correction (P<.05). Fracture patterns were investigated by light microscope. RESULTS. Mean microshear bond strength ${\pm}$ SD (MPa) for each group was $34.9{\pm}17.7$, $32.1{\pm}15.8$, $37.8{\pm}19.3$, $31.3{\pm}12.7$, $44.4{\pm}13.6$, $40.2{\pm}13.2$ respectively. Group 5 showed significantly difference from Group 1, Group 2 and Group 4. Also, Group 6 was found statistically different from Group 4. CONCLUSION. 2 W and 3.5 W Erbium, Chromium: Yttrium-Scandium-Gallium-Garnet laser application were found efficient in removing resin residues.