• 제목/요약/키워드: p-th moment

검색결과 21건 처리시간 0.026초

Tutorial: Methodologies for sufficient dimension reduction in regression

  • Yoo, Jae Keun
    • Communications for Statistical Applications and Methods
    • /
    • 제23권2호
    • /
    • pp.105-117
    • /
    • 2016
  • In the paper, as a sequence of the first tutorial, we discuss sufficient dimension reduction methodologies used to estimate central subspace (sliced inverse regression, sliced average variance estimation), central mean subspace (ordinary least square, principal Hessian direction, iterative Hessian transformation), and central $k^{th}$-moment subspace (covariance method). Large-sample tests to determine the structural dimensions of the three target subspaces are well derived in most of the methodologies; however, a permutation test (which does not require large-sample distributions) is introduced. The test can be applied to the methodologies discussed in the paper. Theoretical relationships among the sufficient dimension reduction methodologies are also investigated and real data analysis is presented for illustration purposes. A seeded dimension reduction approach is then introduced for the methodologies to apply to large p small n regressions.

Genetic Trend for Growth in a Closed Indian Herd of Landrace × Desi Crossbreds

  • Gaur, G.K.;Ahlawat, S.P.S.;Chhabra, A.K.;Paul, Satya
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제11권4호
    • /
    • pp.363-367
    • /
    • 1998
  • This study has objectives of to estimate the genetic and phenotypic trend for growth in a closed herd of Landrace $\times$ desi crossbreds. The possibility of early selection of boars was also investigated in order to reduce generation interval and thus, to enhance response per year in selection programmes. The data originated from Livestock Production Research (Pigs), Indian Veterinary Research Institute (IVRI), Izatnagar (UP), India - a unit of All India Coordinated research Project on Pigs (AICRP on Pigs). Data consisted of 891 crossbred piglets, progeny of 29 boars. The piglets were born in 132 parities of 72 sows between 8 years from 1987 to 1994. Records on weight at birth, at 2 weeks interval upto 8 weeks of age (Wl, W2, ${\cdots}\;{\cdots}$ W8) and at 16th week (W16) were used in this investigation. BLLTP estimates of the sires were computed. Breeding value of each sire was estimated as twice of sire and sire group solutions. Phenotypic trend was estimated as regression of weight performance on year. Genetic trend was computed by estimating regression of breeding value of sires on time. Average body weights ranged from 0.92 kg (W1) to 18.95 kg (W16) and showed a continuous increase over age. Heritabilities of the weight at 4th and 6th week were medium (0.29 and 0.14). Rest of the weights were highly heritable. The product moment and rank, both correlations were high between breeding value for W6 and W16 (0.68 and 0.70). This shows that sire selection for W6 can be successfully implemented in order to achieve sufficient genetic improvement in growth. Phenotypic trend was positive at all ages. The phenotypic regression coefficient ranged from 0.02 kg at birth to 0.40 kg at 16 weeks. Genetic trend was also positive. The regression coefficients of average breeding value of sires on time showed a range of 1.471 kg (0.021 to 1.492 kg) for different weights. These coefficients were significant and higher than their corresponding phenotypic regression coefficient.

일부 노인들의 수치료에 의한 통증경감과 만족도 조사 (Pain Relief and Satisfaction by Hydrotherapy among Urban Elderly)

  • 이인학;윤정인;문성기
    • The Journal of Korean Physical Therapy
    • /
    • 제14권3호
    • /
    • pp.273-296
    • /
    • 2002
  • This study was conducted to investigate the pain relief score and the degree of satisfaction among elderly people. This study has done from July 11th, 2001 to August 31st, 2001 at Hydrotherapy Facility in the College of Bogun(Taejon Health Sciences College) located in Taejeon, Korea. Eighty-eight patients were participated to the questionnaire. The results were as follow. 1. The mean value of the pain relief score in the female group was higher than the mean value of the pain relief score in the male group(p<0.05). The mean value of the pain relief score in the group having religion was higher than the group not having religion(p<0.05). The pain relief score was not significantly different in age, presence of spouse, the way of housing, and academic background. The degree of satisfaction was not significantly different in sex, age, presence of spouse, the way of housing, religion, and academic background. 2. The pain relief score and the degree of satisfaction were not significantly different in the presence of comorbidity, going with the hydrotherapy, and the moment of diagnosis. 3. According to the ADL, the mean value of the pain relief score in the Independent was higher than the mean value in maximal assistance and minimal assistance(p<0.05). Independent, maximal assistance and minimal assistance were not significantly different in the degree of satisfaction (p<0.05). 4. The pain relief score and the degree of satisfaction were not significantly different in the legion of pain.

  • PDF

뇌졸중 후 강직(spasticity) 평가를 위한 Tone Assessment Scale의 신뢰도 (Reliability of the Tone Assessment Scale for Poststroke Spasticity)

  • 김태호;정이정
    • 한국전문물리치료학회지
    • /
    • 제9권2호
    • /
    • pp.133-144
    • /
    • 2002
  • The purpose of this study was to establish reliability of the Tone Assessment Scale (TAS) translated into Korean in patients with stroke. The TAS consists of resting posture, response to passive movement, and associated reaction to active effort. Fifteen patients (14 males, 1 female) were examined by two raters. Surface electromyography (EMG) data at elbow flexor muscle and joint excursion were collected from 6 patients. To identify the correlation between muscle activity and angular changes of elbow muscle, Pearson product moment correlation was used. The inter-rater and intra-rater reliability of the TAS ranged from very good to good (K/Kw=.61~1.00 for intra-rater and K/Kw=.73~1.00 for intra-rater comparisons) in the sections of resting posture and associated reaction. However, in the section of response to passive movement, the reliability coefficients ranged from very good to fair (Kw=.29~1.00). In the 11th item, correlation between EMG ratio of elbow flexor and angular changes of elbow joint showed statistically strong positive relationship (r=.94, p<.05). These results indicate that the TAS is selectively reliable in the sections of resting posture and associated reaction.

  • PDF

방사오리의 접촉자극이 벼 생육, 내도복성 및 수량에 미치는 영향 (Effect of Physical Stimulation by Free-Ranging Ducks on Growth, Lodging Resistance and Yield of Paddy Rice)

  • 고병대;중서양효;만전정치;송영한
    • 한국환경농학회지
    • /
    • 제20권4호
    • /
    • pp.232-237
    • /
    • 2001
  • 이상의 결과에서, 방사오리의 벼 접촉자극에 의해 줄기를 포함한 지상부 및 지하부의 건물중량은 유의적으로 증가하고, 벼초장, 간장 및 하위절간의 신장생장은 현저하게 억제되는 것이 인정되었다. 또한 오리 접촉자극에 의해 줄기의 좌절저항력은 크게 증가하는 반면, 휨 모멘트는 감소함을 보여 벼 도복억제 또는 도복경감의 효과가 시사되었다. 수량형질에 있어서 오리의 접촉자극에 의해 1이삭당 평균영화수, 등숙율 및 천립중은 대차 없었으나 유효분얼경수 및 포기당 이삭수의 현저한 증가가 인정되어 최종적으로 벼 수량의 증가를 볼 수 있었다. 금후, 본 연구에서 얻어진 결과를 바탕으로 방사오리의 접촉자극과 벼 생장과의 메커니즘을 보다 과학적으로 해명할 필요가 있고, 이를 위해서는 오리행동을 모방한 인위적인 접촉자극에 의한 영향 및 식물의 생장 반응에 영향하는 것으로 알려진 메치오닌, 에칠렌, 지베렐린 등의 식물생장호르몬과 접촉자극과의 관련성에 대한 추가적인 검증과정이 필요할 것으로 사료된다.

  • PDF

병아리에서 인산칼슘 첨가제의 생물학적 이용성 (Biological Availability of Various Sources of Ca and P Supplements in Young Chicks)

  • 이재호;지규만
    • 한국가금학회지
    • /
    • 제15권3호
    • /
    • pp.219-227
    • /
    • 1988
  • 본 실험은 사료첨가제로 사용되는 인산칼슘제에 들어있는 Ca과 P의 생물학적 이용성을 측정 비교하고자 실시하였다. 5일령의 수평아리를 사용하여 12 일간의 실험기간 후에 경골의 회분함량율 기준으로 하여 표준계선에 의한 least square방식으로 측정한 이용성의 결과는 다음과 같다. 1. P의 이용성은 DiCa-P첨가제가 각각 77.1, 91.0, 96.4 그리고 95.5%를 나타냈고 TriCa-P첨가제는 각각 94.1, 95.0 및 99.5%를 나타냈다. 2. Ca의 이용성은 DiCa-P 첨가제에서 각각 78.3, 234.1, 87.6 그리고 244.5%였고 TriCa-P첨가제는 각각 99.5, 84.0 및 101.5 %였다. 3. 전반적으로 TriCa-P첨가제가 DiCa-P첨가제보다 이용성이 약간 높게 나타났다. 4. 국산과 외국산 인산칼슘제의 이용성의 차이는 없었다.

  • PDF

오미자 추출물을 첨가한 두부의 품질특성 (Quality Characteristics of Soybean Curd With Omija Extract)

  • 김좌숙;최선영
    • 한국식품영양학회지
    • /
    • 제21권1호
    • /
    • pp.43-50
    • /
    • 2008
  • This study used Omija extract as a natural congelation to compare and analyze soybean curd's physicochemical and sensory quality characteristics in order to improve functional benefits and taste of soybean curd. When Omija extract concentration increased, protein content went up considerably while crude fat and yield significantly decreased. In the pH change, the group with Omija extract were lower than control and the change was not much noticeable but slightly checked as the storage period was extended. The turbidity tended to increase as the storage period was longer. In the acidity change, the group with 0.5% Omija extract showed rapid increase on the 4th day after starting storage, and it can be interpreted that decomposition started at the moment. As the storage period was extended, brightness and yellowness remarkably decreased and redness considerably enhanced: higher concentration Omija extract worked to decreased brightness and to increase yellowness and redness. In accordance with the storage period, hardness, brittleness and gumminess increased and springness decreased, but there was no considerable change in cohesiveness: in accordance with the concentration, hardness, brittleness and gumminess significantly increased, but there was no considerable change in cohesiveness. In terms of sensory quality, the group with 1% of Omija extract showed the best appearance, flavor, taste and after swallowing results. The group with 1% Omija extract was the most preferred, $4.89{\pm}0.32$ in the overall preference. In conclusion, adding Omija extract can improve soybean curd's physicochemical and sensory quality characteristics. Moreover, the extracts can be expected to play an important role in encouraging Omija's value and widening its appliances to various food.

C자형 영상증강장치를 사용한 방사선 투시하에 피부로부터 대요근 근구까지의 깊이에 대한 연구 (A Study of the Depth from the Skin to the Psoas Compartment under C-arm Guidance)

  • 우승훈;강정권;오완수;홍기혁
    • The Korean Journal of Pain
    • /
    • 제13권1호
    • /
    • pp.93-96
    • /
    • 2000
  • Background: Psoas compartment block with local anesthetics and corticosteroids is one of the treatments which provides long term analgesia of the lower back and anterior thigh unilaterally, and its technical easiness and safety allows blind application without C-arm guidance in the out-patient clinic. This study aimed to evaluate the mean of the depth from the skin to the psoas compartment, and its correlation to the following attributes: age, weight, height and PI (Ponderal Index). Methods: We investigated 28 patients who underwent psoas compartment block. All blocks were performed using Chayen's method (punctured at the point of 3 cm caudally and 5 cm laterally from the 4th lumbar vertebral spinous process) with a 22 G, 8 cm Tuohy needle under C-arm guidance. We recorded the depth from skin to the psoas compartment, height, weight and PI (weight (kg)/height (cm)$\times100$ (%)). Data were analyzed using the Pearson product-moment correlation coefficients. The correlations between the depth and other attributes identified by p-value of less than 0.05 were considered statistically significant. Results: The mean depths from skin to the psoas compartment were $6.02{\pm}0.28$ cm in men, $5.44{\pm}0.22$ cm in women. There is no significant correlation between the depth and other patient's attributes. Conclusions: The mean depths from skin to the psoas compartment may be one of the guide for psoas compartment block in outpatient clinics without C-arm guidance.

  • PDF

부분 무치악 고정성 임플랜트 보철하에서 교합접촉정도에 관한 연구 (A STUDY ON THE DEGREE OF OCCLUSAL CONTACT UNDER THE FIXEDIMPLANT PROSTHESIS OF PARTIALLY DENTULOUS PATIENTS)

  • 송금영;계기성;정재헌
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.281-299
    • /
    • 1995
  • The purpose of this study was to evaluate the degree of occlusal contact under the fixed implant prosthesis of partially edentulous patients which was hased on occlusal concept of implant prosthesis. From the patients who have free-standing implant supported prosthesis of unilateral partially edentulous area, occlusal and occlusal contact point of th enatural tooth side and implant side of light closure and heavy closure were analyzed by T-scan system throuht pre-and post-adjustment and the degree of occlusal contact was estimated by Shimstock. The following results were obtained : 1. The occlusal force of natural tooth side(NF) from mid-sagittal axis was relatively constant at light and heavy closure through pre-and post-adjustment, but the occlusal force of implant side(IF) was decreased significantly at light closure(P<0.01) and heavy closure(P<0.05) of post-adjustment. 2. Natural tooth side-implant side moment(MIMoment) fo occlusal force from mid-sagittal axis was significant(p<0.05) through pre-and post-adjustment and the deviation from mid-sagittal axis was increased at light closure of post-adjustment, but was decreased at heavy closure of post-adjustment. 3. Comparing the NF and IF, IF was greater at heavy closure of pre-adjustment, and NF was greater at light closure of post-adjustment, and the NF and IF was relatively equally distributed at light closure of pre-adjustment and at heavy closure of post-adjustment. 4. The number of occlusal contact point of natural tooth side(NC) was relatively constant through pre-and post-adjustment, but the number of occlusal contact point of implant side(IC) was significantly decreased(P<0.05) at light closure of post-adjustment, and was not significant but was lesser at heavy closure of post-adjustment. 5. Difference of the NC and IC was greater at light closure of post-adjustment, but it was less at heavy closure of post-adjustment, and therefore occlusal contact point of natural tooth side and implant side was relatively equally distributed at heavy closure of postadjustment. 6. When bilaterally distribution of occlusal force and occlusal contact point was established, degree of occlusal contact of implant suporoted prosthesis with opoosing teeth at light clousre was $34.13{\pm}21.69{\mu}m$.

  • PDF

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.