• Title/Summary/Keyword: ozone-water

Search Result 583, Processing Time 0.027 seconds

Adsorption and catalytic ozonation of aquatic organic compound by acid-treated granular activated carbon (산 처리한 활성탄을 이용한 수중 유기물의 흡착 및 오존 분해)

  • Nam, Yun-Seon;Rhee, Dong-Seok
    • Journal of Industrial Technology
    • /
    • v.31 no.B
    • /
    • pp.127-132
    • /
    • 2011
  • Humic substances is accounted for for the largest proportion in natural organic matter(NOM) and NOM is widely distributed in varying concentration in all aquatic and soil. They can affect water quality adversely in several ways by contributing undesirable color, complexing with metal and yielding metal concentrations exceeding normal solubility. Ozonation is one of the efficient treatments for degradation of humic substances which cause some problems in water treatment. Especially, the combination of ozone and granular activated carbon was applied to degradation humic acid in aquatic system. The aim of this work to test the available of acid-treated granular activated carbon as catalyst in the ozonation of humic acid.

  • PDF

ATOSPHERIC CORRECTION FOR ASTER THERMAL RADIOMETRY USING MODIS ATMOSPHERIC PROFILES

  • Park, Wook;Choi, Jae-Won;Lee, Yoon-Kyung
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.305-308
    • /
    • 2008
  • The goal of this study is to retrieve ASTER thermal radiometry using a radiative transfer model. The MODTRAN is used for the model because it is easy to use with high spatial resolution and it is possible to specify input parameters such as profiles of temperature, water vapor density, ozone, aerosols and any of the other gasses. Most of parameters such as temperature and water vapor profiles were obtained from the Terra MODIS. The selected ASTER scene images land and coastal area. The surface radiance of ASTER TIR bands were retrieved by MODTRAN and extracted atmospheric profiles from MOD07 and US standard 76 models. Radiance estimated using MOD07 data was systematically lower by about 0.5-1.0 $W/m^2$ sr ${\mu}m$ than that by US standard 76 model between the two cases.

  • PDF

A Case Report on Fungal Contamination and Remediation in a Leakage-water Damaged Apartment

  • Cho, Jun-Ho;Paik, Nam-Won
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.418-423
    • /
    • 2006
  • 이 사례연구는 누수가 있었던 고층 아파트의 공기중 진균 오염 실태를 조사하고, 이를 개선하기 위해 취해진 복원방법의 효과를 평가하기 위해 실시하였다. 공기중 진균은 주로 엔더슨 샘플러를 사용하여 측정하였다. 누수가 있었던 아파트의 복원 전 공기중 진균 농도는 매우 높았다(평균: $51,000\;cfu/m^{3}$, 기하평균: $40,163\;cfu/m^{3}$). 고농도의 오존처리와 오염된 벽체 철거 후 공기중 진균 농도는 상대적으로 매우 낮아졌으며(평균: $1,118\;cfu/m^{3}$, 기하평균: $899\;cfu/m^{3}$), 제거효율은 96.3%로 나타났다. 철거되지 않고 남아 있던 인근 벽체의 벽지를 제거하고 살진균제 처리를 실시한 결과, 공기중 진균 농도는 상대적으로 안전한 수준까지 낮아졌으며(평균: $95\;cfu/m^{3}$, 기하평균: $88\;cfu/m^{3}$), 제거효율은 99.7 %로, 나타났다. 결론적으로, 누수가 있었던 아파트의 공기중 진균 농도는 매우 높은 상태로 오염이 심한 상태이었으나, 본 연구에서 적용한 복원방법들은 공기중 진균 농도 저감에 있어서 매우 높은 효율을 나타냈다.

Degradation of 1,4-Dioxane using $O_3$/$H_2O_2$

  • Suh, Jung-Ho;Mohseni, Madjld
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.139-144
    • /
    • 2003
  • 1, 4-dioxane is a recalcitrant pollutant found in contaminated ground waters and industrial effluents. Conventional water treatment techniques are limited to treat this compound effectively. In this study, $O_3$$H_2O_2$ oxidation process was used to eliminate 1, 4-dioxane in water and to enhance the biodegradability. Several factors affecting biodegradability enhancement were investigated. The relationship between initial oxidation rate of 1 A-dioxane and BOD enhancement rate has been determined, a kinetic model has been proposed. $H_2O_2$ concentration and pH had a proportional relation with biodegradability of 1, 4-dioxane, but in case of ozone, there was no relationship with biodegradability. 1, 4-Dioxane removal efficiencies had good agreement with the biodegradability.

  • PDF

A Study on the Removal of THM(trihalomethane) (THM(trihalomethane)제거(除去) 대책(對策)에 관(關)한 연구(硏究))

  • Lee, Seok Hun;Hwang, Sun Jin;Park, Chung Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.7 no.2
    • /
    • pp.34-38
    • /
    • 1993
  • An experimental study was conducted to investigate the effects of chlorine dioxide and ozone on reduction of THM(trihalomethane) formation. Precursor concentration, chlorine concentration, reaction time, pH, and temperature were governing compornents of THM formation. When other conditions are constant, THM formation increased linearly with precursor concentration increased. THM formation increased when pH increased from 5 to 9. In combined treatment with chlorine and chlorine dioxide, chlorine treatment after chlorine dioxide treatment made less THM than any other case does. Ozonation reduced THMFP(THM formation potential) of THM precursor. THMFP decreased exponentially with reaction time increased. Also biodegradability of humic acid was enhanced by ozonation.

  • PDF

Ozone disinfection criteria for contactor design (오존접촉조 설계를 위한 소독 기준)

  • Dumeau C;Boisdon V
    • 수도
    • /
    • v.24 no.6 s.87
    • /
    • pp.23-31
    • /
    • 1997
  • Ozonation is an effective process in providing microbiologically safe drinking water. The operation of the ozonation stage is often based on disinfection criteria which include security factors, such as the CT criterion. This type of ozonation management, which mat include large safety margins, will no longer be possible, since formation of ozonation byproducts has to be avoided. In order to reduce the security factor, a computerized tool to predict with more accuracy inactivation of micro-organisms in the ozonation process has been developed.

  • PDF

The Characteristics of Charging Water Spray at Electrostatic Precipitator

  • Chung, J.H.;Kanazawa, S.;Ohkubo, T.;Nomoto, Y.;Adachi, T.
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.132-136
    • /
    • 1994
  • The new spray system is proposed by using a pipe with hygroscopic needle electrode In order to develop an air-cleaning ESP with high collection efficiency for submicron particles and high removal efficiency for NOx, SO$_2$, NH$_3$. Fundamental characteristics of charging water spray, which is not an usual wet type, are investigated experimentally. As a result, corona discharging mode and ozone generation rate are significantly affected by the operational conditions, such as the applied voltage and wet condition of the needle electrode.

  • PDF

Changes in Water Quality and Bacterial Compositions in Culture Water of an Ozonated Flounder Farm (오존 처리한 넙치 양식장 사육수의 수질과 미생물 변동)

  • Park, Seongdeok;Kim, You Hee;Park, Jeonghwan;Kim, Pyong-Kih
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • This study assessed the effect of ozone to control pathogenic bacteria in inlet water flowing to flounder farms, establishing operational parameters of ozonation at seawater conditions. Hydraulic retention time in a reaction pipeline after ozonation was fixed at 3 minutes in a flow through system. Concentrations of total residual oxidant (TRO) by ozonation were measured according to different ozonation intensities. The oxidant reduction potential (ORP), which is indirect but enables real-time measurement, was measured in relation to TRO values. TRO values were $0.01{\pm}0.01mg\;L^{-1}$ at an ORP range of 320-410 mV, $0.07{\pm}0.02mg\;L^{-1}$ at 600 mV, and $0.16{\pm}0.03mg\;L^{-1}$ at 700 mV. A heterotrophic marine bacteria colony was reduced by 80.6-97.9%, showing the suppression effect of ozonation on total bacteria in inlet water. At an ORP range of 400-500 mV, colonies of heterotrophic marine bacteria, Vibrio spp., and gram negative bacteria were significantly reduced in outlet water from a culture tank with ongrowing flounder (230 g) at a stocking density of $8kg\;m^{-2}$. Especially, Vibrio spp. and gram negative bacteria were seldom found at 400-500 mV. The daily feeding rate was from over 0.7% to total body weight at 300-500 mV, showing better performance than that in the control. The pathogenic bacteria entering the flounder farm were effectively removed when the ORP range to 400 mV or less.

Assessment of Micro Organic Pollutants Removal Using Advanced Water Treatment Process and Nanofiltration Process (고도처리공정과 나노여과공정에서의 미량유해물질 제거 평가)

  • Kang, Joon-Seok;Choi, Yang-Hun;Kwon, Soon-Buhm;Yu, Young-Beom
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.579-587
    • /
    • 2014
  • Various kinds of micro organic pollutants have frequently been detected from a water system. Therefore, it is considered to be very important part in the drinking water treatment system. And the research about removal process and processing efficiency have been being conducted briskly. In this study, the removal efficiency was evaluated using advanced water treatment process and nanofiltration process. The removal efficiency of nanofiltration process was very different according to physical and chemical characteristics of materials. The molecular weight of cutoff was the most influential factor in the removal efficiency. And when pKa value was higher than pH of raw water or Log Kow value was below 2, the removal efficiency of material was decreased. In case of oxidation reaction, the bigger the molecular weight of material was and the more hydrophobic a material was, the less oxidation reaction occurred. And the removal efficiency was decreased. Most unoxidized materials were removed by absorption. And the more actively oxidation reaction occurred by $H_2O_2$, the more absorption reaction increased.

VOCs Removal in Drinking Water Treatment Process by Ozonation (오존산화에 의한 수처리공정에서 VOCs의 제거 특성)

  • Han, Myung-Ho;Choi, Joon-Ho;Lim, Hak-Sang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.65-75
    • /
    • 1997
  • Removal characteristics of volatile organic carbons(VOCs) by ozone oxidation and other processes in the raw water of the 1st Nakdong water treatment plant were investigated. Dichrolomethane, toluene and other 7 compounds were detected in the raw water. With regard to detected 4 compounds in finally treated water, it was found that VOCs could not be removed effectively by traditional water treatment process. Benzene, 1,2-dichlorobenzne were not detected in the raw water but they were detected in the process of treatment. The compound of highest detection frequency was dichloromethane. When the raw water was controlled at pH 7, temperature $20^{\circ}C$, 5 minutes as contact time, 10 minutes as reaction time, the removal rate of THMFP, $KMnO_4$ demand, TOC, $UV_{254nm}$ and $NH_3-N$ were 46.4%, 22%, 19.6%, 31% and 8%, respectively. From estimating the finally treated water qualities in 7 kinds of treatment processes, P-6 process(raw water-chlorination-coagulation-ozonation) was most effective for organics removal and THMs control. Removal efficiencies for $KMnO_4$ demand and TOC by the process which combined preozonation with coagulation was twice better than only preozonation. $NH_3-N$ removal rate was shown as 10% by P-3 process(raw water-coagulation-ozonation), but 83% of $NH_3-N$ was removed by P-4 process(raw water-coagulation-chlorination). It was found that the chlorination is more effective than the ozonation for the NH3-N removal as commonly known.

  • PDF