• Title/Summary/Keyword: ozone-water

Search Result 583, Processing Time 0.027 seconds

Ozone-Enhanced Remediation of Diesel-Contaminated Soil (II): A Column Study (Ozone에 의한 유류오염토양 복원 연구 (II) : 토양 컬럼상에서의 오존 산화)

  • Choi, Heechul;Heechul;Lim, Hyung-Nam;Kim, Kwang-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1825-1832
    • /
    • 2000
  • Column experiments were conducted by using soil columns, to investigate feasibility and efficiency of in-situ ozone enhanced remediation for diesel-contaminated soil. The injection of gaseous ozone into soil column revealed the enhanced decomposition of ozone due to the catalytic reaction between ozone and metal (e.g., Fe, Mn etc.) oxides as evidenced by as much as 25 times shorter half-life of ozone in a sand packed column than in a glass beads packed column. Substantial retardation in the transport of and the consumption of ozone were observed in the diesel contaminated field soil and sand packed columns. After 16 hrs ozonation, 80% of the initial mass of diesel (as diesel range organic) concentration of $800{\pm}50mg/kg$, was removed under the conditions of the flow rate of 50mL/min and $6mg-O_3/min$. Whereas, less than 30% of diesel was removed in the case of air injection. Analysis of the residual TPH(total petroleum hydrocarbon) and selected 8 aliphatics of diesel compounds in the inlet and the outlet of the column confirmed that diesel nonselectively reacted with ozone and then shifted to lower carbon numbered molecules. Water content also was found to be an important parameter in employing ozone to the hydrocarbon-contaminated soil.

  • PDF

Effects of Retention Time on the Simultaneous of Odor Removal and Sludge Solubilization Using a Non-Thermal Plasma System (저온 플라즈마와 활성슬러지 복합 공정에서 체류시간 변화가 악취 저감 및 슬러지 가용화에 미치는 영향)

  • NamGung, Hyeong-Gyu;Hwang, Hyun-Jung;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.815-824
    • /
    • 2011
  • In this study, a non-thermal plasma system was employed to simultaneously remove odorous compounds and organic sludge. The system consisted of two reactors; the first one was the non-thermal plasma reactor where ozone was produced by the plasma reaction and the ozone oxidized hydrogen sulfide, the model odorous compound, and then the ozone-laden gas stream was introduced to the second reactor where wasted sludge was disintegrated and solubilized by ozone oxidation. In this study, the gas retention time (GRT) and the hydraulic retention time (HRT) were changed in the two-reactor system, and the effects of GRT and HRT on reduction efficiencies of odor and sludge were determined. As the GRT increased, the ozone concentration increased resulting in an increasing efficiency of hydrogen sulfide removal. However, the overall ozone loading rate to the second sludge reactor was the same at any GRT, which resulted in an insignificant change in sludge reduction rate. When HRTs in the sludge reactor were 1, 2, 4 hours, the sludge reduction rates were approximately 30% during the four-hour operation, while the rate increased to 70% at the HRT of 6 hours. Nevertheless, at HRTs greater than 4 hours, the solubilization efficiency was not proportionally increased with increasing specific input energy, indicating that an appropriate sludge retention time needs to be applied to achieve effective solubilization efficiencies at a minimal power consumption for the non-thermal plasma reaction.

A Treatment Efficiency of Wastewater by using Sym-Bio Process and Dissolved Ozone flotation Process for Water Reuse (하수처리수 재이용을 위하여 Sym-bio공정과 용존 오존 부상공정을 이용한 하수처리의 효율 분석)

  • Park, Changyu;Park, Jaehan;Lee, Kyunghee;Ahn, Yoonhee;Ko, Kwangbaik;Jung, Hyuncheol
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.86-90
    • /
    • 2008
  • Water reuse of effluent is limited, due to bacteria and chromaticity or turbidity which may result in low perception of water quality. Consequently, this study showed a method in the reuse of treated wastewater by a diversified treatment method, with separation of centralized reformation of aeration tank into pre-treatment with minimum installation of facilities, and post-treatment, applying advanced oxidation treatment. A pilot plant experiment was performed using Sym-Bio process adopting an NADH Sensor without modification of the exiting aeration tank. The Dissolved Ozone Flotation process, which is an advanced oxidation process, to treat the remaining organics, nutrients, chromaticity, turbidity and bacteria. As a result in the Sym-Bio process, the biological treatment, even on the condition of single stage reaction tank, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS and T-N were 96.6%, 84.6%, 88.25%, 95.1% and 71.0%, respectively, while that for T-P was 25.0%, which required further treatment. In the Dissolved Ozone Flotation process, the advanced oxidation treatment, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS, T-N, T-P, chromaticity, turbidity, bacteria, coliforms were 78.9%, 34.6%, 28.7%, 48.0%, 70.4%, 82.4%, 84.0%, 74.5%, 99.8% and 99.4%, respectively.

A Study on the Development of Bleaching efficiency for flex fabrics by Using Ozone Treatment (오존을 이용한 마직물의 표백성 향상에 관한 연구)

  • Lee, Mun-Soo;Song, Kyong-Hun;Kim, Gyoung-A;Song, Bong-Keun;Lee, Rae-Yohn
    • The Journal of Natural Sciences
    • /
    • v.10 no.1
    • /
    • pp.93-102
    • /
    • 1998
  • In order to study on the bleaching efficiency of flex fabrics, ozone which has been produced by an ozone generator, has been contacted with flex fabrics in water at various conditions. The equipments used for the ozone reatment of flex fabrics were the ozone generator and a liquor/ozone contactor. For the study of the bleaching efficiency on flex fabrics, the Hunter's whiteness, tensile strength, microscopic properties of the ozone treated flex fabrics were measured. The concentration of generated ozone was increased, as the voltage increase, flow ratio decrease and oxygen amount increase. The bleaching efficiency of ozone treated fabrics was increased with increasing the net concentration of ozone. The whiteness ozone of treated fabrics was found to be best when treated temperature was $0-15^{\circ}C$ and treated time was 20 min. The tensile strength of treated fabrics decreased as the treating time increased, and as the temperature raised.

  • PDF

Removal of Odor and THM from the Raw Water of Daecheong Dam (대청호 원수내 냄새 및 THM 제거방안 연구)

  • Jeon, Hang-Bae;Yun, Gi-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.3
    • /
    • pp.235-245
    • /
    • 1997
  • A pilot scale study for removing odor and trihalomethane formation potential (THMFP) was investigated in the standard water treatment plant equipped with ozone oxidation and granular activated carbon (GAC) adsorption processes. The removal efficiency of dissolved organic carbon (DOC) in the pilot scale standard water treatment process (PSWTP) was about 25%, however, no more removal in the ozone oxidation process. On a GAC after 30 days operation, DOC removal efficiency was about 75%. Odor removal efficiency was about 30% in PSWTP, 60% in ozone oxidation, and almost complete in well as DOC. Mid-1 and 2 that showed breakthrough in odor inducing material as well as DOC. Mid-1 and 2 chlorination was able to reduce trihalomethanes (THM) by 25% compared to prechloringation, while postchlorination alone could reduce them by 30%.

  • PDF

Study On The Development of Mobile Shampoo Device Using Ozone Water For Good hair condition (모발에 좋은 오존수를 이용한 이동식 샴푸 장치 개발에 관한 연구)

  • Kim, Duck-Sool
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.394-399
    • /
    • 2017
  • The goal of this study is to suggest the technology and the way of developing ergonomic shampoo device, which is able to adjust the height and to be devided, and it uses ozone water. As a result of developing the device, it can complete better the effect of preventing water splash than existing devices by making neck holding part higher. And it is also made with ergonomic design, therefore, the head of shampoo candidate can be drawn into it more easily. By adjusting water temperature($38^{\circ}C$) to candidate's taste through water heater attached to water bucket, when a candidate is being shampooed, it can help keep warm shampooing without delaying. We could know the process through temperature sensor. And we could also know the utility of its own sterilization(1PPM) and purification. Finally, ozone water was measured for 20 minutes and the ozone concentration was measured to be less than 1 PPM to ensure stability. All parts of the mobile shampoo stand together with the hot water device and the ozonated water conversion device were designed so as not to be inconvenient for the user to use.

Sterilization Effects of $\gamma-ray$ and Ozone on Microoganisms Contaminated in Angelica keiskei Powde (신선초 분말에 오염시킨 미생물에 대한 감마선과 오존의 살균효과)

  • 권오진;박순연;김광훈;이현자;변명우
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.3
    • /
    • pp.221-225
    • /
    • 1996
  • For the purpose of improving hygienic quality of health-foods, sterilization effects of ${\gamma}$-ray and ozone on microoganisms associated with food cultured in the media and contaminated in Angelica keiskei powder were investigated. Ozone was immersed in water and sprayed in air, on the concentration of 3 mg liter-1 at an air flow rate of 5 liter min-3. Test strains cultured in the media completely inhibited by ${\gamma}$-ray at irradiation doses of 0.25~2 kGy. In the case of ozone, test bacteria inactivated after treatment of 10~20 minutes, but test mold, Aspergillus flavus was not effective. Strains contaminated in Angelica keiskei powder completely inhibited by ${\gamma}$-ray at irradiation doses of 2.5~7.5 kGy. However, when the powder was sprayed with ozonized air for 10hours, Bacillus subtilis and Staphylococcus aureus among five strains were eliminated.

  • PDF

Treatment Study of Textile Wastewater by Fenton's Oxidation (펜톤 산화반응에 의한 염색폐수처리 연구)

  • 박영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.20-25
    • /
    • 2000
  • The wastewater treatment for the purpose of water-recycling was performed using Fenton's & ozone's methods. These methods were used to increase the treatment efficiency of textile wastewater and to search for the optimal operating conditions. The optimal conditions by Fenton process were determined so that input amounts of $FeSO_4{\cdot}7H_2O$ and $H_2O_2$ were $7.2mM/{\;}{\ell}$ and $49.0m/{\;}{\ell}$ respectively, treatment by ozone process had 92% removal efficiency at ozone concentration of 9.73g/min and $130mM/{\;}{\ell}$ of $H_2O_2$.

  • PDF

A Study on the Bleaching of Cotton Fabrics by utilizing Ozone(($O_{3}$) (오존($O_{3}$)을 이용한 면직물의 표백에 관한 연구)

  • Cho, Hwan;Seo, Mal Young;Yu, Jae Sun;Lee, Byung Hyun;Huh, Man Woo;Lee, Kwang Woo;Cho, In Sul;Jong, Hee Cheon
    • Textile Coloration and Finishing
    • /
    • v.5 no.4
    • /
    • pp.49-59
    • /
    • 1993
  • In order to study the bleaching of cotton fabrics, ozone which has been produced by an ozone generator, has been contacted with cotton fabrics in water at various conditions. The equipments used for the ozone treatment of cotton fabrics were the ozone generator and a liquor/ozone contactor. For the examination of the ozone bleaching effect on cotton fabrics the whiteness, tensile strength, wettability and clark softness of the ozone treated cotton fabrics were measured. The conclusion obtained were, ozone concentration was increased, as the voltage was increased and flow rate was decreased and oxygen amount was increased. Bleaching effect of treated fabrics increased with increasing attributed more the net concentration of ozone rather than the total ozone amount of produced. The whiteness of treated fabrics was found to be best when treating temperature was 15~20<$^{\circ}C$, in acidic condition. The tensile strength of treated fabrics decreased as the treating time increased, and as the temperature raised, and the acidity increased. The wicking distance of treated fabrics increased slightly with increasing the treating time and the temperature. Clark softness of treated fabrics was not changed until passing 30min. of the treating time, then it decreasing linealy with increasing the treating time.

  • PDF

The Effects of Ozone on Photosynthesis, Antioxidative Enzyme Activity and Leaf Anatomical Response in the Indoor Plants and Japanese Red Pine (실내식물과 소나무의 오존에 대한 광합성 능력, 항산화 효소의 활성, 해부학적 반응)

  • Lee, Ju Young;Je, Sun Mi;Lee, Seoung Han;Woo, Su-Young
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.4
    • /
    • pp.601-607
    • /
    • 2013
  • The purpose of this study was to identify the effects of ozone pollution on the one woody species and two indoor plants in controlled environment. Pinus densiflora, Spathiphyllum patinii and Epipremnum aureum seedlings were exposed in both control and ozone chambers to investigate photosynthetic rate, water use efficiency, antioxidative enzyme activities such as GR(Glutathione reductase) and APX(Ascorbate peroxidase) activity and leaf anatomical response. Ozone was fumigated 8 hours for a day with 30 ppb concentration for 50 days. Pinus densiflora seedlings showed no significant difference on photosynthetic rate, water use efficiency, antioxidant enzyme activity during ozone exposure. Ozone concentration (30 ppb in this study) is not high enough to generate ozone damage on Pinus densiflora species. In contrast, ozone generally altered photosynthetic rate, antioxidant enzyme (especially GR) activity and leaf anatomy in two indoor species (Spathiphyllum patinii and Epipremnum aureum) exposed in ozone chamber were significantly differ from those of control in every measurement. These data suggest that two indoor species(Spathiphyllum patinii and Epipremnum aureum) are more sensitive to ozone than Pinus densiflora.