MONNTORING AIR QUALITY AND ACIDDEPOSITION IN SOUTHERN U.S.

  • Allen, Eric R.
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1997.10a
    • /
    • pp.1.1-32
    • /
    • 1997
  • Atmospheric monitoring capabilities were established in 1988 by the University of Florida at Duke forest, near Durham. NC: Cary forest, near Gainesville, FL: and Austin forest, near Nacogdoches, TX. Continuous (hourly averaged) measurements of air quality (ozone, nitrogen oxides and sulfur dioxide) and meteorological variables were made at these three low elevation (< 200 meters), rural locations in the southeastern U.S. for more than three years. During the same period at these sites wet and dry acid deposition samples were collected and analyzed on an event and weekly basis, respectively The monitoring locations were selected to determine actual atmospheric exposure indices for southern pine species in support of on-site surrogate exposure chamber studies conducted by Southern Commercial Forest Research Cooperative (SCFRC) investigators. Daily and quarterly averaged ozone maxima were higher (55 ppb) at the northernmost site in the network (Duke forest) in the second and third quarters (spring and summer seasons) and lower (35 ppb) in the first and fourth quarters (winter and fall seasons), when compared to ozone levels at the two southernmost sites (Cary and Austin forests). Seasonal ozone levels at the latter two sites were similar Nitrogen oxieds and sulfur dioxide levels were insignificant (< 5 ppb) most of the time at all sites, although soil emissions of NO at two sites were found to influence nighttime ozone concentrations. Typical maximum quarterly and annual aggregate ozone exposure indices were significantly higher at Duke forest (92.5/259 ppm-hr) than those values observed at the two southern sites (65.6/210 ppm-hr). Acid deposition (wet and dry) components concentrations and deposition fluxes observed at the Duke forest, NC piedmont site, were generally greater, dependent on site and season, than corresponding variables measured at either of the two southern coastal plain sites (Cary and Austin forests). Acid deposition variables observed at the latter two sites were remarkably similar, both qualitatively and quantitatively, although the sites were located 1300 km apart. A comparison of deposition fluxes of elemental nitrogen (NO3, NH4') and sulfur (5042-, SO3) components in wet and dry forms indicated that wet deposition accounts for approximately 70% of the total nitrogen and 73% of the total sulfur input on an annual equivalent basis at all sites.

  • PDF

Analyses of the OMI Cloud Retrieval Data and Evaluation of Its Impact on Ozone Retrieval (OMI 구름 측정 자료들의 비교 분석과 그에 따른 오존 측정에 미치는 영향 평가)

  • Choi, Suhwan;Bak, Juseon;Kim, JaeHwan;Baek, KangHyun
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.117-127
    • /
    • 2015
  • The presences of clouds significantly influence the accuracy of ozone retrievals from satellite measurements. This study focuses on the influence of clouds on Ozone Monitoring instrument (OMI) ozone profile retrieval based on an optimal estimation. There are two operational OMI cloud products; OMCLDO2, based on absorption in $O_2-O_2$ at 477 nm, and OMCLDRR, based on filling in Fraunhofer lines by rotational Raman scattering (RRS) at 350 nm. Firstly, we characterize differences between $O_2-O_2$ and RRS effective cloud pressures using MODIS cloud optical thickness (COT), and then compare ozone profile retrievals with different cloud input data. $O_2-O_2$ cloud pressures are significantly smaller than RRS by ~200 hPa in thin clouds, which corresponds to either low COT or cloud fraction (CF). On the other hand, the effect of Optical centroid pressure (OCP) on ozone retrievals becomes significant at high CF. Tropospheric ozone retrievals could differ by up to ${\pm}10$ DU with the different cloud inputs. The layer column ozone below 300 hPa shows the cloud-induced ozone retrieval error of more than 20%. Finally, OMI total ozone is validated with respect to Brewer ground-based total ozone. A better agreement is observed when $O_2-O_2$ cloud data are used in OMI ozone profile retrieval algorithm. This is distinctly observed at low OCP and high CF.

Inter-comparison of Total Ozone from the Ground-based and Satellite Measurements at Seoul (지상과 위성으로부터 측정된 서울시 대기 중 오존 전량의 상호 비교)

  • Hong, Hyunkee;Kim, Jhoon;Lee, Hanlim;Cho, Hi Ku
    • Atmosphere
    • /
    • v.23 no.2
    • /
    • pp.123-130
    • /
    • 2013
  • Despite the extensive investigations to understand the difference between ground-based and space-borne measurements, there still exist differences in total ozone (TO) measured at those two different platforms. Comparisons were carried out for the first time between TO data obtaiend from the ground based Dobson and Brewer spectrophotometers, and the Ozone Monitoring Instrument (OMI) on board EOS-Aura satellite in a megacity site in Northeast Asia. The TO values retrieved by the OMI-DOAS (Differential optical absorption spectroscopy) algorithm tend to be lower than those measured by the ground based sensors in spring and summer as well as the low solar zenith angle condition. We found that such underestimation of the OMI-DOAS TO is caused by tropospheric ozone underestimated by the OMI-DOAS algorithm when tropospheric ozone are significantly enhanced.

The Influences of 5ea Breeze on Surface Ozone Concentration in Pusan Coastal Area, Korea (부산 연안역의 오존 농도에 미치는 해풍의 영향)

  • 김유근;이화운
    • Journal of Environmental Science International
    • /
    • v.5 no.3
    • /
    • pp.265-275
    • /
    • 1996
  • Air pollution characteristics and the influence of sea breeze on surface ozone concentration were studied using the data measured at 7 air quality continuous monitoring stations from June to September using 3 years (1990, 1993, 1994) in Pusan coastal area. Among the 246 sea breeze days for research Period, there were approximately 89 sea breeze days (36%) from lune to September, And there were 120 the episode days (68%) of ozone greater than or equal to 60 ppb in summer season. In 89 sea breeze days, the episode day was highly marked as 56 days (63%). So, we knew that the sea breeze greatly affects the occurence of ozone episode day. the ozone concentration under the condition of the sea breeze increase about 40% in the daytime. Frequencies distribution of $O_3$ concentration for sea breeze moved toward high concentration class. The characteristics of ozone concentration in relation to meteorological conditions of sea breeze is significant because we can discover major weather factors for eastablishing an air pollution- weather forecast system. For further. study about meterological approach method for photochemical air pollution, it is necessary to explain the characteristics of atmosphere below 1, 000 m, especially concerning the formation mechanism of inversion layers. And finally, we will study the relationships to synoptic weather conditions and vertical structure and diurnal variation of local wind systems including sea breeze, and the vertical movements of atmosphere in the city.

  • PDF

Development of a Passive Sampler using a Fluorescence Material for the Ambient Ozone (형광물질을 이용한 대기 중 오존 Passive Sampler의 개발)

  • 임봉빈;정의석;김선태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.483-491
    • /
    • 2004
  • The purpose of this study is to develop an ozone passive sampler and to evaluate its performance p-Acetamidophenol using as the reagent for ozone reacts specifically with the ambient ozone to produce a fluorescence material (p-acetamidopheonl dimer). The volume of absorbent solution and the extraction time determined at suitable conditions for measuring ozone were 100$\mu$L and 60 min, respectively. The changes of fluorescence were observed with incresing the storage period of passive samplers in ambient air. but the cool storage in a refrigerator did not remarkably influence the increase of fluorescence. The measurement for the precision oi the passive sampling was carried out with duplicate measurement of passive samplers. The intra-class correlation coefficients of passive samplers using dry and wet filters were 0.992 and 0.962, respectively The results from field validation tests indicated practical agreement (dry filter: r=0.963, wet filter: r=0.995) between the passive sampler and an UV photometric $O_3$ analyzer. The limit of quantification of ozone passive samplers with sampling time of 8 hr (wet filter) and 24 hr (dry filter) were 8.0 ppb and 2.7 ppb, respectively.

A Study on the Characteristics of Antecedent Meteorologic Conditions on High Ozone Days in Busan (부산지역 고농도 오존일의 선행 기상 특성 연구)

  • Do, Woo-Gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.24 no.8
    • /
    • pp.993-1001
    • /
    • 2015
  • Comparing to the other air pollutants like $SO_2$, CO, the number of exceedance of the ozone national ambient air quality standard(NAAQS) and the ozone warning increased recently in Busan. The purpose of this study is to find out the preliminary symptoms for high ozone days in Busan area. In order to find out the preliminary symptoms, the hourly ozone data at air quality monitoring stations and the hourly meterological parameters at Busan regional meteorological 2007 to 2013 were used for the analysis. Averaged daily max ozone concentration was the highest(0.055 ppm) at Noksan and Youngsuri in the ozone season from 2007 to 2013. The horizontal distributions of daily max. ozone including all stations in Busan at high ozone days(the day exceeding 0.1 ppm of ozone concentration at least one station) were classified from two to five clusters by hierarchial cluster analysis. The meteorological variables showing strong correlation with daily max. ozone were the daily mean dew point temperature, averaged total insolation, the daily mean relative humidity and the daily mean cloud amount. And the most frequent levels were $19-23^{\circ}C$ in dew point temperature, $21-24 MJ/m^2$ in total insolation on the day before, $2.6-3.0 MJ/m^2$ on the very day, 67-80% in relative humidity and 0-3 in cloud amount.

Studies on the Behaviour of Ozone Concentration and the Influencing Factors (오존농도의 動態 및 影響因子에 關한 硏究)

  • 金旻永;姜熙坤;李完宗;李相七;張鳳勳;朴聖培
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.55-71
    • /
    • 1989
  • This study was carried out to determine the ozone concentration to behaviour and the factors to be influenced the variation of its concentration in the ambient air in Seoul. Measurements of ozone concentrations were made at 10 monitoring station to take care of SIHE (Seoul Institute of Health & Environment) during December 1987 to November 1988, also measured the hourly average concentration of sulfur dioxide, total suspended particulate, nitrogen oxide $(NO & NO_2)$, carbon monoxide, hydro carbon $(n-CH_4 & THC)$ and meteorological factors, that is, temperature, humidity, wind velocity wind direction and ultraviolet intensity etc, for the same period at same place. The basis of the data obtained were analyzed statistically along with the various data. The results were as follows; 1. The annually arithmetic mean concentration of ozone for the 10 sites during one years was 10.0 ppb and ranged from 3.1 $\pm$ 4.5ppb at the Kuro industrial complex to 17.2 $\pm$ 18.7 ppb at the Ssangmun site. 2. The frequency of hours on which oxidant concentrations exceeded the present short term standard of ozone (100 ppb) were 78 times. 3. The diurnal patterns of hourly ozone concentrations in Seoul area was a typical bi-modal variation which have 4 to 5 a.m. peak and 3. to 4 p.m peak. 4. The time ozone of highest ozone concentration in a whole day and hight was 1 to 5 p.m and 90.9 percent of appearence rate. 5. The diurnal patterns of hourly ozone concentrations in Seoul were on the whole the order of daytime from 5.8ppb to 28.7 ppb evening from 1.7 to 18.7 ppb night time from 1.9 to 9.3 ppb daybreak from 1.4ppb according to measuring sites, and the highest that observed at the Ssangmun area while the lowest was the Kuro industrial complex monitor sites. 6. The weekly variation of ozone concentration was the higher level ozone concentration in the day of the week occured sunday-monday and weekend but the decrease were observed from wednesday to thursday.

  • PDF

The Characteristics of Temporal and Spatial Distribution of Surface Ozone Concentration in Jeju Island (제주지역 지표 오존 농도의 시.공간적 분포 특성)

  • Lee, Gi Ho;Kim, Dae Jun;Heo, Cheol Gu
    • Journal of Environmental Science International
    • /
    • v.13 no.4
    • /
    • pp.377-387
    • /
    • 2004
  • This study has been performed to clarify the characteristics of temporal and spatial distribution of surface ozone concentration over Jeju Island, one of the cleanest areas in Korea with low emissions of air pollutants. Ozone data are monitored at four sites in Jeju Island. These monitoring sites are located at two urban area(referred to Ido and Donghong), coastal area(Gosan site) and forest site(Chuna site). Ozone data has been routinely collected at these sites for the late four years. The patterns of seasonal cycle of ozone concentrations at all stations show the bimodal with the peaks on spring and autumn and a significant summer minimum. However, the patterns of diurnal variations at rural station, i.e., Gosan and Chuna sites are considerably different to those at urban stations such as Ido and Donghong sites. The patterns of $\DeltaO_3$ variations are very similar with those of monthly mean ozone concentrations and $\DeltaO_3$ values are exceeded 30 ppb, at urban stations. This may be that urban stations are more influenced by local photochemical reactions rather than rural stations. In order to assess the potential roles of meteorological parameters on ozone formation, the meteorological parameters, such as radiation, temperature, and wind are monitored together with ozone concentrations at all stations. The relationships of meteorological parameters to the corresponding ozone concentration are found to be insignificant in Jeju Island. However, at Gosan and Donghong stations, when the sea breeze blew toward the station, the ozone concentration is considerably increased.

Study on the Characteristics of Surface Ozone Distributions and the Ozone Critical Levels to Vegetation in the South Korea (남한 지역의 지면 오존 농도 특성과 식생에 대한 임계값 적용 연구)

  • Koo, Hae-Jung;Park, Soon-Ung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2008
  • Concentration of tropospheric ozone ($O_3$) was investigated for the South Korea. And then the critical ozone levels, expressed as AOT40 (Accumulated exposure over a threshold of 40 ppb) to vegetation have been used in this region within the UNECE (United Nations Economic Commission for Europe) Convention on Long-Range Trans-boundary Air Pollution (CLRTAP). Hourly ozone concentration data from 1996 to 2001 at 26 air monitoring stations was used to estimate the exceedance of the critical levels. It was calculated for daylight hours for each station, and mapped using surface interpolation over the South Korea. The critical levels of ozone have shown the highly exceeded value in the Gyeonggi region, southern coastal region and central inland of the South Korea. It was some different from the typical ozone distribution which represented highly in the western inland and coastal regions. The area exceeding the critical level for crops was founded to be more than 40% of the whole South Korean territory. While that for trees was to be about 17% of the South Korea. The critical ozone critical level was based upon data from experiments on specific species, and thus may not be fully representative for all types of vegetation. Nevertheless, the critical level and its exceedance of the ozone concentration would be one of the useful tools for international agreements on abatement strategies to prevent ecosystem damage.

Spatial-temporal variations in surface ozone concentrations in Busan metropolitan area (부산지역 오존농도의 시·공간 분포 변화)

  • Kang, Yoon-Hee;Kim, Yoo-Keun;Hwang, Mi-Kyeong;Jeong, Ju-Hee;Kim, Hyunsu;Kang, Min-Seong
    • Journal of Environmental Science International
    • /
    • v.28 no.2
    • /
    • pp.169-182
    • /
    • 2019
  • Temporal and spatial variations in surface ozone concentrations in Busan were investigated by using observation data from urban air quality sites during 2001-2016. The annual ozone concentrations showed a significant increasing trend of $+0.40ppb\;yr^{-1}$ in this period, with a more rapid increase of $+0.81ppb\;yr-1$ since 2010. For the monthly analysis, the increase in ozone concentration was the greatest in August ($+0.68ppb\;yr-1$). These ozone trends were due mainly to rising temperature ($+0.05^{\circ}C\;yr^{-1}$) and weak decreasing precipitation ($-6.42mm\;yr^{-1}$). However, the extreme weather events (heat wave, localized heavy rain, etc.) lead to an increase in short-term variability of ozone since 2010. The relatively low ozone concentrations in the downtown area were caused by high NOx emissions from mobile sources. The increases in ozone concentrations were observed at most of the air quality monitoring sites due to the reductions in anthropogenic emissions of NOx during 2001-2015. However, in the southern coastal area, lower rates of increase in ozone concentrations were observed by $-0.10{\sim}0.25ppb\;yr^{-1}$ due to the significant NOx emitted by ships in the Busan port and Busan new port.