• 제목/요약/키워드: ozone level

검색결과 198건 처리시간 0.024초

서울시 대기오염과 일별 사망의 상관성에 관한 시계열적 연구 (1998∼2001년) (A Time-Series Study of Ambient Air Pollution in Relation to Daily Mortality in Seoul, 1998∼2001)

  • 조용성;이종태;김윤신;홍승철;김호;하은희;박혜숙;이보은
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.625-637
    • /
    • 2003
  • This study was performed to examine the relationship between air pollution exposure and mortality in Seoul for the years of 1998∼2001. Daily counts of death were analyzed by general additive Poisson model, with adjustment for effects of seasonal trend, air temperature, humidity, and day of the week as confounders in a nonparametric approach. Daily death counts were associated with CO (current day),O$_3$ (current day), PM$_{10}$ (current day), NO$_2$ (1 day before), SO$_2$ (1 day before). Increase of 41.71 $\mu\textrm{g}$/㎥ (interquartile range) in PM$_{10}$ was associated with 1.3% (95% CI = 0.7∼1.9%) increase in the daily number of death. $O_3$ concentrations resulted in an increased risk of 1.3% for 23.86 ppb in all-aged mortality [RR = 1.013 (1.004-1.023)1. This effect was greater in children (less than 15 aged) and elderly (more than 65 aged). After ozone level exceeds 25 ppb, the dose-response relationship between mortality and ozone was almost linear. We concluded that Seoul had 1∼5% increase in mortality in association with IQR (interquartile range) in air pollutants. Daily variations in air pollution within the range currently occurring in Seoul might have an adverse effect on daily mortality. These findings also support the hypothesis that air pollution, at levels below the current ambient air quality standards of Korea, is harmful to sensitive subjects, such as children or elderly.rly.

산악연안지역에서 내부중력파와 해륙풍순환 영향하의 대기오염농도 (Atmospheric Pollutant Concentrations under the Influences of Internal Gravity Wave and Sea-Land Breeze Circulations in the Mountainous Coastal Regions)

  • Hyo Choi;Joon Choi
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제23권1호
    • /
    • pp.18-33
    • /
    • 1995
  • 동쪽 연안지역에서 큰 경사를 갖인 산맥위를 흘러가는 종관규모의 서풍하에서 내부 중력파와 같은 강한 하강폭풍이 산의 후면에서 발생되어 진다. 주간에 해양에서 내륙으로 향하는 중규모의 열적 강화에 의해 유도되는 해풍순환이 동쪽으로 향하는 내부중력파에 기인하여 연안의 앞바다까지만 국한된다. 따라서 연안해 근처의 표층풍은 외해나 내륙의 위치에서보다 상대적으로 더 약하다. 명백하게 서풍의 내부중력파순환파 해면 근처에서 동풍 및 상층에서 서풍을 갖는 해풍순환과 같은 두개의 상이한 종류의 대기순환이 뚜렷하게 나타났다. 이런 상황에서 강릉시에서의 대기오염물질은 반대 방향의 두개의 상이한 순환에 의해 갇히게 되고 부유분진과 오존의 고농도가 초래되었다. 야간에 육지에서 연안해로 향하는 중규모의 육풍은 기존의 동쪽으로 향하는 하강풍과 협력하여 연안지역에서 서풍의 더욱 강화를 유도할 수 있었다. 산쪽에서 연안해로 향하여 부는 강한 표층풍에 의해 조절되는 부유분진의 농도는 추간의 경우보다 야간에 비교적 더 높았으며, 상층대기로 부터 지표면으로 오존의 하양수송에 기인하여 오존의 농도가 주간보다 야간에 매우 높았다. 결과로 바람폭풍하의 산악연안지역에서 대기오염농도는 바람푹풍 전.후보다 더 높았다.

  • PDF

Assessment of Embryotoxicity of 2-Bromopropane in ICR Mice

  • Kim, Jong-Choon;Shin, Dong-Ho;Kim, Sung-Ho;Oh, Ki-Seok;Kim, Hyeon-Yeong;Her, Jeong-Doo;Jiang, Cheng-Zhe;Chung, Moon-Koo
    • Toxicological Research
    • /
    • 제19권3호
    • /
    • pp.227-234
    • /
    • 2003
  • 2-Bromopropane (2-BP), a halogenated propane analogue, is a substitute for chlorofluorocarbones (CFCs) which have a great potential to destroy the ozone layer and to warm the earth's environment. The present study was undertaken to evaluate the potential adverse effects of 2-BP on pregnant dams and embryo-fetal development after maternal exposure during the gestational days (GD) 6 through 17 in ICR mice. The test chemical was administered subcutaneously to pregnant mice at dose levels of 0, 313, 625 or 1,250 mg/kg/day. All dams were subjected to caesarean section on GD 18 and their fetuses were examined for external, visceral and skeletal abnormalities. In the 1,250 mg/kg group, maternal toxicity included an increase in the incidence of abnormal clinical signs and a decrease in the maternal body weight, body weight gain, and corrected body weight. Developmental toxicity included a decrease in the fetal body weight, a reduction in the placental weight, an increase in the fetal skeletal variation and ossification delay. There were no adverse effects on either pregnant dams or embryo-fetal development in the 313 and 625 mg/kg groups. These results suggest that a 12-day subcutaneous dose of 2-BP is embryotoxic at a maternally toxic dose (i.e., 1,250 mg/kg/day) in ICR mice. In the present experimental condition, the no-observed-adverse-effect level of 2-BP is considered to be 625 mg/kg/day for dams and embryo-fetuses, respectively.

일부 업종의 용접흄 분석 및 폭로농도에 관한 연구 (A study on the airborne concentration of welding fume for some manufacturing industries)

  • 변상훈;박승현;김창일;박인정;양정선;오세민;문영한
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.172-183
    • /
    • 1995
  • The airborne concentrations of the welding fumes produced during $CO_2$ arcwelding process at shipbuilding, shiprepairing, container manufacturing and car accessary manufacturing industry were investigated. The effects how much reduced the welding fume were checked when the portable fan was used. The results were as follows; 1.The geometric mean of welding fume concentration in shipbuilding factory was $10.05mg/m^3$. This exposure concentration was higher than other 3 manufacturing industries at 95% confidence level. 2. The sampling filters for welding fume could be digested with acid within 1 hour by microwave oven. The recoveries for investigated metal elements were all over 95%. 3. The optimal wavelength could be selected for the simultaneous analysis of 8 metal elements by ICP(Inductively Coupled Plasma). 4. Noxious gases($O_1,NO_2$) produced during $CO_1$ gas arc welding process were detected that the concentration of ozone($O_1$) was less than 0.01 ppm and that of nitrogen dioxide($NO_2$) was 0.01-0.03 ppm. 5. The geometric mean of welding fume particle diameter was $1.26{\mu}m$ and geometric standard deviation was 1.51 for the counts when particle an analyzer(ELZONE) had been used. 6. When the portable fan had been used,the reduced percent of total welding fume for workers was about 47.8% when portable fan was applied to blow and 71.7% when to exhaust.

  • PDF

PM10과 오존이 연령군별 천식 입원에 미치는 영향 (Age Dependencies in Air Pollution-associated Asthma Hospitalization)

  • 배현주;하종식;이애경;박정임
    • 한국환경보건학회지
    • /
    • 제34권2호
    • /
    • pp.124-130
    • /
    • 2008
  • This study investigated the age dependencies in ambient air pollution-associated asthma hospitalization from 2003 to 2005 in Seoul. For all ages and the age groups of 0-14, 15-64, and 65+years, the Generalized Additive Model (GAM) was used to estimate the relative risks of daily asthma hospitalization associated with changes in particulate matter and ozone. The time-trends, seasonal variances, day effects, temperature, humidity, and pressure at sea level were controlled in the models. Significant associations were observed between asthma hospitalization and the levels of $PM_{10}$ and $O_3$. The relative risks (RRs) of asthma hospitalization for every 10 unit increases in $PM_{10}({\mu}g/m^3)$ and $O_3$(ppb) were 1.008 (95% CI 1.005-1.012), and 1.012 (95% CI 1.003-1.020), respectively. Evaluated over $10\;{\mu}g/m^3$ increase in $PM_{10}$, we found the relative risks of asthma hospitalization to be 1.009 (95% CI 1.004-1.014) in 0-14 age group, and 1.015 (95% CI 1.008-1.022) in 65+ age group. Considering 10 ppb increase in $O_3$, those were 1.014 (95% CI 1.003-1.024) in 0-14 age group, and 1.025 (95% CI 1.009-1.041) in 65+ age group. It was concluded that current levels of ambient air pollution in Seoul make a significant contribution to the variation in daily asthma hospitalization. Further reduction in air pollution is necessary to protect the health of the community, especially that of the higher risky groups including children and elderly population.

Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템 (Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode)

  • 이인제;강치중;김용상;김주호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.

막결합형 생물반응조에서 슬러지 전처리가 잉여슬러지 발생량에 미치는 영향 (Effects of Sludge Pre-Treatment on the Excess Sludge Production in a Membrane-Coupled Bioreactor)

  • 이강훈;김주현;;염익태
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.565-572
    • /
    • 2011
  • The effects of chemical pretreatments on the excess sludge production in the membrane-coupled bioreactor were investigated. In addition, their effects on membrane fouling were also evaluated. Two membrane bioreactors were operated. In one reactor, a part of the mixed liquor was t reated with NaOH and ozone gas consecutively and was returned to the reactor. T he f lowrate of the chemical pretreatment stream was 1.5% of the influent flowrate. During the 200days of operation, the MLSS level in the bioreactor with mixed liquor pretreatment was maintained relatively constant at the range of 8,000 ~ 10,000$mg/{\ell}$ while it increased steadily up to 26,000 $mg/{\ell}$ in the absence of the pretreatment. Each reactor was equipped with two laboratory membrane modules where the flux for each module was 20, and 30 ${\ell}/m^2{\cdot}h$, respectively. With pretreatment, almost constant transmembrane pressure(TMP) was observed throughout the operation at the flux of 20 ${\ell}/m^2{\cdot}h$. Without pretreatment the membrane module at the same flux could also be operated at relatively stable condition. However, as the MLSS increases up to 25,000 $mg/{\ell}$, a fast TMP increase was observed. In conclusion, a complete control of excess sludge production in the membrane-coupled bioreactor was possible without significant deterioration of the treated water quality. In addition, it was shown that stable operation in terms of TMP is possible with sludge pretreatment and recirculation.

삼상 유동층 반응조를 이용한 해수 순환 여과 시설의 수처리 (Water Treatment of Seawater Recirculating Aquaculture System by Using Three Phase Fluidized Bed Reactor)

  • 이병헌;최혁;류종수
    • 한국양식학회지
    • /
    • 제13권2호
    • /
    • pp.137-145
    • /
    • 2000
  • 삼상 유동층 반응조의 수처리 효율을 검토하기 위해 해수 순환여과 시설을 운전하였다. 수처리 시스템은 유동층 반응조, 카트리지 필터, 오존접촉조로 구성되어 있고, 전체 운전기간동안 사육조내 수질인자별 평균농도는 각각 COD 9mg/L, 총암모니아(TAN) 0.22mg/L, 아질산성 질소 0.05mg/L, 질산성 질소 20mg/L, 탁도 3.64 NTU, SS 9.5mg/L, pH 7.6, 알칼리도 70mg/L 등으로 나타나 양호한 수질조건을 유지할 수 있었다. 유동층 반응조의 TAN 부하량 범위는 4.3~32.9 g/$m^3$/day였고, 평균 제거율은 20 g/$m^3$/day으로 나타났다. 각 반응조의 TAN 제거율은 47~60%로 나타나 해수에서도 효과적인 암모니아 제거 특성을 나타내었다. 또한 유출수의 비이온성 암모니아 농도는 0.002 mg/L이하로 유지 할 수 있었다

  • PDF

청정지역과 도시지역에서 $NO_2$ 광분해율이 오존농도에 미치는 영향에 관한 연구 (A Study on Effect of $NO_2$ Photodissociation rate on Ozone concentration from Rural and Urban Area in the Winter)

  • 이정주;이동범;윤중섭
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.141-147
    • /
    • 2000
  • Due to a rapid in automobiles since the 1980’s, the concentration of NO, and HC has also increased along with cases of VOCs. These air pollutants have created $O_3$ concentration, which cause a harmful effect to the human health. This issue has become a subject of great public interest. For this paper, to compare the concentration of $O_3$, NO, N $O_2$ between the rural and urban area in the winter, the concentrations of each have been measuredevery hour during Jan.~Feb. 2000, 1998, respectively. To calculate the Photochemical Steady State, $\Phi$= $J_{N O_2}$[N $O_2$]/ $k_1$[NO][ $O_3$], temperature and $J_{ N O_2}$ has been determined. The NO concentration in the rural are showed at below 10 ppb while the NO concentration in the urban area showed maximum value of 90~120 ppb. But the $O_3$ concentration in both areas showed less than 30 ppb. The reason is that the N $O_2$ photodissiciation rate is low due to the temperature being below 2$^{\circ}C$ and less than 60 degrees in the solar zenith angle during the winter time, which makes the $O_3$ concentration in both areas, similar in the concentration level. N $O_2$ photodissociation rate in both ares showed maximum value of 3.0mW/$\textrm{cm}^2$. Values of $\Phi$ determined from the rural area was consistently the unity, approaching 1. But values of $\Phi$ determined from the urban was roughly higher than unity, approaching above 1or 2 for clear sky-high sun(10:00~16:00).

  • PDF

BIM 기반 에너지성능분석을 통한 공동주택의 주동 설계 전략개발 - 주동타입 및 층수 변화를 중심으로 - (Multi-Family Housing Block Design Strategy Development by BIM-based Energy Performance Analysis - focusing on the Block Types and the Variations in Stories -)

  • 전재홍;박혜진;이권형;추승연
    • 대한건축학회논문집:계획계
    • /
    • 제34권2호
    • /
    • pp.3-11
    • /
    • 2018
  • Korea has achieved a rapid economic development and with the increase in population and national income and the expansion of social and economic activities, energy consumption has rapidly increased too. Energy consumption per head has constantly increased and currently, power consumption per head is 7.5 times bigger than in 1985. Buildings occupy 25% of total energy consumption and especially, 50% of total energy is consumed for heating and cooling. In this situation, multi-family housing, which has constantly been increased, has an energy saving rate of 1.9%, which is the lowest level and this makes the government's energy policy for sustainable energy system development useless. Besides, energy consumption leads to secondary problems, such as air, water and marine pollution and heat pollution and wastewater/drainage and the increased use of fossil fuel is a fundamental reason for ozone layer destruction and global warming. Therefore, efficient energy consumption plans are required. This study aims to analyze energy performance in each block type of high-rise and diversified multi-family housing that accounts for 60% of all the housing forms, depending on the variations in stories through BIM-based energy simulation. For this study, four representative block types were selected, based on the multi-family floor plan, which is certified for energy performance evaluation and they were applied to the floor plan of a multi-family house that is scheduled to be built. Then BIM modeling was conducted from the fifth story to the 40th story at an intervals of 5 stories and based on the finding, energy characteristics of each block type and energy performance depending on the variations in stories were analyzed. It is considered that this would serve as objective data for block type and block story decision of energy performance-based multi-family housing.