• Title/Summary/Keyword: ozone generation rate

Search Result 66, Processing Time 0.593 seconds

중첩방전 반응기에 의한 오존의 생성 (Ozone Generation by Superimposing Discharge Reactor)

  • 우인성;황명환;조정국;이영희;목연수
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.63-68
    • /
    • 1999
  • In this paper, characteristics of ozone generation by using coil and SPCP + DC corona reactor was studied. The ceramic-based surface discharge electrode, which was first invented as a high-efficiency ozonizer, has been used as an experimental plasma chemical reactor.(Surface Induced Plasma Chemical Processing, SPCP.) The electrode, however, has a structural disadvantage that a highly energetic plasma region is localized near the electrode surface, which may make it impossible for higher efficiency to realize. In an attempt to overcome this advantage, we have developed a hybrid reactor which employs a corona discharge unit together with the surface discharge unit. Experimental results suggest that the efficiency of the ozone production rate is improved when positive corona discharge is added.

  • PDF

평판형 오존발생기의 방전면적에 따른 방전 및 오존생성특성 (The Characteristics of Discharge and Ozone Concentration for plate type ozonizer with Discharge Area variation)

  • 이창호;이상근;송현직;김종현;윤병한;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.346-349
    • /
    • 2007
  • In this paper, the ozonizer is equipped with three electrodes ( two external electrodes, central electrode ), and AC high voltage which has 180[$180^{circ}C$] phase difference is applied to two H V. Ozone discharge and generation charactristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power. Ozone concentration, generation and yield were proportionally increased with increasing discharge area size.

  • PDF

Effect of Temperature on the Performance Characteristics of a Pin-Cylinder Discharge Type Ozonizer

  • Md. Fayzur Rahman;Chun, Byung-Joon;Lee, Kwang-Sik;Lee, Dong-In
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제12C권4호
    • /
    • pp.201-207
    • /
    • 2002
  • A Pin-Cylinder discharge type ozonizer was designed and manufactured. The increase or decrease of temperature greatly influences on the characteristics of ozone generation of a discharge type ozonizer. The characteristics of ozone concentration ( $O_{3con}$), ozone generation ($_{3g}$) and ozone yield .ate ($_{3Y}$) of the ozonizer were investigated by varying the gas flow rate (Q), the discharge power ($_{Wd}$ ) and the temperature (T). At T = 20($^{\circ}C$), the values of ( $O_{3con}$) were found as 7800,5300,3000 and 2300(ppm) at Q=1,2,4 and 6(1/min) respectively. The corresponding values of ( $O_{3g}$) were found as 917, l247,1411 and 1623(mg/h) and those of ( $O_{3Y}$) were 93,126,143 and 164(g/kWh) respectively. When the temperature is decreased to -50($^{\circ}C$), the values of ( $O_{3con}$) became 12000,8000,5200 and 3600(ppm) at Q=1,2,4 and 6(1/min) respectively. The corresponding values of 0,9 were obtained as 1411,1882,2446 and 2600(mg/h) and those of ($O_{3Y}$) were 143,190,247 and 2631g/kWh] respectively. Hence as the temperature was decreased from 20 to -50[。C], the efficiencies of ozone generation were increased by 54,51,73 and 60[%] at Q=1,2,4 and 6(1/min) respectively.ctively.

다중 펄스 방식에 의한 고성능 오존발생 제어장치 개발 (Development of High Performance Ozone Generating Controller)

  • 이홍희;김형준
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권5호
    • /
    • pp.226-226
    • /
    • 2003
  • When an excessive voltage is applied to the discharge gap in ozone generator, the discharge room temperature becomes higher. As is well own, the efficiency of the ozone generation is deteriorated by the excessively hot temperature because of the decomposition reaction. In this paper, the simple small capacity ozone generating controller has been introduced, which provides effective and stable silent discharge characteristics over wide range input power. The proposed power controller has two important advantages, which imply that the production rate of ozone can be controlled linearly according to the delivered power and the surplus energy is recovered to the source. The experimental results are given to verify the performance of the pre proposed controller.

다중 펄스 방식에 의한 고성능 오존발생 제어장치 개발 (Development of High Performance Ozone Generating Controller)

  • 이홍희;김형준
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권5호
    • /
    • pp.226-230
    • /
    • 2003
  • When an excessive voltage is applied to the discharge gap in ozone generator, the discharge room temperature becomes higher. As is well own, the efficiency of the ozone generation is deteriorated by the excessively hot temperature because of the decomposition reaction. In this paper, the simple small capacity ozone generating controller has been introduced, which provides effective and stable silent discharge characteristics over wide range input power. The proposed power controller has two important advantages, which imply that the production rate of ozone can be controlled linearly according to the delivered power and the surplus energy is recovered to the source. The experimental results are given to verify the performance of the pre proposed controller.

환경개선을 위한 형광방전등형 오존발생기의 특성 (Characteristics of Fluorescent Discharge Lamp Type Ozonizer for Environment Improvement)

  • 박용권;이상근;전병준;송현직;이광식;하장호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.500-505
    • /
    • 2002
  • In this paper, fluorescent discharge type ozonizer has been designed and manufactured. Ozone discharge and generation characteristics have been investigated in accordance with a sort of internal electrodes, output voltage of power supply, air flow rate and discharge power. Air has been used as the supplied gas of the ozonizer In this paper, when disuse fluorescent lamp was used as an internal electrode. Air flow rate was varied from 2[1/min] to 10[1/min]. The maximum ozone concentration and yield were 3495[ppm] and 23.4[g/kWh] respectively at 2[1/min] air flow rate and 35.2[W] input power. Illumination was appeared as 5[lx] within 15[cm] from external electrode. Whorl fluorescent discharge type ozonizer was used, air flow rate was also varied from 2[1/min] to 10[1/min]. At this moment, the maximum ozone concentration and yield were 2824[ppm] and 21.7[g/kWh] respectively at 2[1/min] air flow rate and 30.5[W] input power. Illumination was also appeared as 5[lx] within 15[cm] from external electrode like used fluorescent lamp.

살균과 탈취를 위한 오존 발생장치의 설계

  • 김현종;윤영미;한지혜;김영란;이은미;이현철;정봉우
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.509-512
    • /
    • 2001
  • Recently, our country's piggery has been becoming large-sized and crowded gradually in scale. Thus, the environment in a piggery is getting worse, which leads to a drop in livestock's immunoactivity. Therefore, livestocks are exposured to many diseases(stress, hypertension, stomach ulcer etc.). In this paper, our intention is to design a low cost ozone-generating device with high capacity to maintain a reasonable ozone level, that is necessary for cleaning the environment in a piggery, but is not too high to cause any harmful influence to human beings and livestock. The results showed that the UV-lamp tube with baffle has an increase of 25% in ozone generation efficiency compared to without baffle and the short retention time of air or high inlet air rate shows high level of ozone.

  • PDF

지하철 역사 내 코로나 바이러스 저감을 위한 이온풍 집진기 개발 (Development of an ionic wind dust collector towards coronavirus reduction in subway stations)

  • 신동호;김영훈;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2022
  • Since 2019, the corona virus has been continuously affect human life. In particular, in the indoor space where people live, infection by airborne transmission of viruses is a problem. Among them, the spread in the subway, which is the main mode of transport for humans, can be serious. To solve this problem, our research team developed an ionic wind collector to collect and remove corona virus using an ionic wind collector and ozone. In order to apply the ionic wind collector to the subway, it must operate in two modes. Because large amounts of ozone are harmful to the human body. There is a mode that collects bio-aerosol from the air using ionic wind and a mode that inactivates viruses floating in the air by generating a large amount of ozone. As the applied voltage increased, the cleaning ability of the ionic wind collector increased, and the farther the distance between the discharge electrode and the ground plate, the higher the cleaning ability even at low current. In addition, clean air delivery rate (CADR) of an ionic wind collector was up to 5.5 m3/min. As a result of measuring the amount of ozone generated, it was confirmed that 50 ppb to 250 ppb was generated, and it was confirmed that ozone generation was controllable in the ionic wind dust collector.

오존 발생기용 전원 장치 개발 및 특성에 관한 연구 (A Study on the characteristics and Development of Power supply for ozonizer)

  • 김종해;배상준;이영식;조기연;정성균;이봉섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2069-2071
    • /
    • 1997
  • The power semiconductor switching devices(PSSD) continuously developed, Power Electronic Technology using PSSD is gradually extended. The high frequency inverter to generate the large power high frequency subject to power electronic technology pursuit various application. Also, in emboss with environmental destruction problem cause the atmosphere and the water pollution to growth of the commercial society, the research in favor of cleansing environmental a pollutant actively proceed. This paper describe study on the ozone generation power supply using the high frequency electric field method and the lamp type ozone generator using photochemistry, one of method of gene-rate ozone.

  • PDF

Application of ozone treatment in cooling water systems for energy and chemical conservation

  • Ataei, Abtin;Mirsaeed, Morteza Ghazi;Choi, Jun-Ki;Lashkarboluki, Reza
    • Advances in environmental research
    • /
    • 제4권3호
    • /
    • pp.155-172
    • /
    • 2015
  • In this study, a complete set of recirculating cooling water system and the required instruments were built in a semi-industrial-scale and a 50 g/h ozone generation plant and a chlorine system were designed for cooling water treatment. Both chlorination and ozonation treatment methods were studied and the results were analyzed during two 45-days periods. The concentrations of ozone and chlorine in recirculating water were constant at 0.1 mg/lit and 0.6 mg/lit, respectively. In ozone treatment, by increasing the concentration cycle to 33%, the total water consumption decreased by 26% while 11.5% higher energy efficiency achieved thanks to a better elimination of bio-films. In case of Carbon Steel, the corrosion rate reached to 0.012 mm/yr and 0.025 mm/yr for the ozonation and chlorination processes, respectively. Furthermore, consumptions of the anti-corrosion and anti-sedimentation materials in the ozone cooling water treatment were reduced about 60% without using any oxidant and non-oxidant biocides. No significant changes in sediment load were seen in ozonation compared to chlorination. The Chemical Oxygen Demand of the blow-down in ozonation method decreased to one-sixth of that in the chlorination method. Moreover, the soluble iron and water turbidity in the ozonation method were reduced by 97.5% and 70%, respectively. Although no anaerobic bacteria were seen in the cooling water at the proper concentration range of ozone and chlorine, the aerobic bacteria in chlorine and ozone treatment methods were 900 and 200 CFU/ml, respectively. The results showed that the payback time for the ozone treatment is about 2.6 years.