• 제목/요약/키워드: ozone generation rate

검색결과 66건 처리시간 0.025초

Al2O3 유전체를 이용한 산소/공기 원료에 따른 오존발생기의 특성 (A Characteristic Analysis of Ozone Generator Using the Al2O3 Ceramic Dielectric According to Gas Type(O2/Air))

  • 박현미;송현직;박원주;이광식
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.76-81
    • /
    • 2014
  • The ozone generation is commonly made with silent discharge method using quartz glass dielectric. In this paper, using $Al_2O_3$ dielectric to instead of the traditional quartz glass dielectric to improve the system efficiency is presented. The dielectric was manufactured as tube shape (Internal diameter${\times}$ Outside diameter: $11{\times}15mm$) using 99% $Al_2O_3$ ceramic. The characteristics of dielectric discharge and ozone generation were studied of experiments with variation of discharge power, discharge electrode space and rate of flow for supplied gas ($O_2$/Air). As the experimental results, in the same discharge space, the ozone concentration continuously increased with input power increasing, and ozone yield increased until saturation happened. Also, the expended power increased with discharge space extended due to discharge power increased. In additional, the ozone concentration of oxygen ozone was higher than air that was observed when using oxygen ozone in proposed experiments.

방사선 치료 시 치료실 내에서 발생하는 오존에 관한 고찰 (Consideration about Ozone Generation in the Treatment Room While Treating a Patient)

  • 곽용국;윤일규;이제희;유숙현
    • 대한방사선치료학회지
    • /
    • 제21권2호
    • /
    • pp.75-82
    • /
    • 2009
  • 목 적: 방사선 치료 시 치료실 내에서 발생하는 오존량을 측정하여 오존 발생으로 인한 오염 정도를 알아보고자 한다. 대상 및 방법: 선형가속기(Clinac 21EX, Varian, USA)와 오존 측정기(series-200, aeroQual, New Zealand)를 이용하여 water phantom (Wellhofer, IBA, Germany)에 방사선을 조사하여 MU, 선량율, 선원-표면간 거리(SSD), 조사야, 에너지, 경과 시간에 따라 발생되는 오존량을 측정 분석하였으며, 실제 환자치료 시 치료실 내에 오존 측정기를 위치하여 일일 오존 변화량을 측정하였다. 결 과: 방사선 발생 중 생성되는 오존의 오염도는 에너지에 따른 영향을 크게 받지 않지만 대체로 광자선보다 전자선 조사 시(0.016~0.028 ppm/hr) 많이 발생하였다. 또한, Dose-Rate가 높을수록(0.016~0.025 ppm/hr), SSD가 멀어지고(0.018~0.030 ppm/hr), 조사야가 넓어지고(0.016~0.025 ppm/hr), MU가 많을수록(0.018~0.046 ppm/hr) 오존 농도가 높아졌다. 시간 경과에 따른 오존의 감소량은 방사선을 조사한 후 10분이 경과된 후부터 background 농도(0.016 ppm/hr)로 변화하였다. 그리고 방사선 치료실 내의 일일 발생하는 오존의 농도는 실내의 오존 허용기준인 0.1 ppm/hr (측정 평균 0.06 ppm/8 hr) 이하이지만, 냄새에 민감한 환자들이 감지할 수 있는 수준인 0.02 ppm/hr 이상의 농도(최대: 0.038 ppm/hr)를 포함하는 것을 확인할 수 있었다. 결 론: 일정한 조건의 변화에 따른 오존 농도를 통하여 실제 치료실 내 오존 발생량은 환자나 작업종사자에 대해 유해한 작용을 미치는 수준은 아니었다. 흔히 오존을 해로운 기체라고 생각하지만 방사선 치료 시 발생되는 미량의 치료실 내 오존은 오히려 병원성 세균이나 바이러스 살균 등의 공기 정화 작용을 함으로써 치료실 내 이로운 오존의 역할을 할 것이라 사료된다.

  • PDF

도깨비봉형 오존발생장치이 펄스커로나 방전에 의한 오존 발생 특성 (High Efficiency Ozone Generation Using a Pyramid-Project-Embossed Rod-to-Cylinder Electrode and a Pulse Corona Discharge)

  • 문재덕;이근택
    • 대한전기학회논문지
    • /
    • 제38권8호
    • /
    • pp.650-657
    • /
    • 1989
  • The conversion efficiency of an ozone generator can be significantly improved by modifying the discharge electrode of a helical strip line rod-to-cylinder type ozone generator to a pyramid-project-embossed rod, and by using a pulse corona discharge. Parametric studies have been carried out to obtain optimum values of peak pulse voltage, pulse forming capacitance, feeder cable and ozone generator capacitance, interelectrode spacing and corona tip density of ozone generator, and feed air flow rate and temperature. The generated ozone concentration was very dependent upon the value of pulse forming capacitance, feeder cable and ozone generator capacitance, and corona tip density. Maximum conversion efficiency was obtained with a pulse forming capacitance of about 500pF, 75pF matched feeder cable and ozone generator, and a corona tip density of 16mm. When operated at optimum values, ozone yield of 79, 99, 80 g/KWh for the different interelectrode type ozone generators tested were obtained, which are approximately 30% higher than that of an industrial ozone generator.

  • PDF

3상 전압을 사용한 중첩방전형 오존발생기의 오존생성 및 방전잡음특성 (The Ozone Generation and Discharge Noise Characteristics of Superposed Discharge Noise Characteristics of Superposed Discharge Type Ozonizer Using Three-Phase Voltage)

  • 전병준;송현직;김영훈;최상태;이광식
    • 조명전기설비학회논문지
    • /
    • 제14권2호
    • /
    • pp.59-67
    • /
    • 2000
  • 본 논문에서는 단목무성방전과 3상 전압을 사용한 중첩무성방전을 인가할 수 있는 오존발생기를 설계.제작하였다. 오존발생기는 3개의 전극(중심천극, 내부천극 및 외부전극)과 2개의 방전갭(중심전극과 내부전극 사이의 갭 및 내부전극과 외부전극 사이의 갭)으로 구성되어 있으며, 단목무성방전과 3상 중접방전이 인가되는 방식에 따라 오존화 가스가 생성된다. 이때 방전전력과 원료가스($O_2$)의 유량의 변화에 따른 오존생성특성을 연구한 결과, 단독무성방전의 경우, 최대 2300[ppm], 570[mg/h] 및 745[g/kWh]의 오존생성특성을 얻을 수 있었으며,3상 전압을 인가한 경우에는 5039[ppm], 1773[mg/h] 및 851[g/kWh]을 각각 얻을 수 있었다. 따라서 3상 중첩무성방전 이 단독무성방전에 비하여 오존생성특성올 향상시킬 수 있음을 확인하였다.

  • PDF

평판형 오존발생장치의 오존생성특성에 관한 연구 (A study on ozone generation characteristics in a Plate Type Ozonizer System)

  • 이상근;이동욱;문경수;박중협;전병준;송현직;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.205-208
    • /
    • 2000
  • In this paper, a plate type ozonizer has been designed and manufactured to minimize the size of ozonizer. This ozonizer have following benefits: convenience of shift and installation maximize space utility. Therefore, ozone generation characteristics have been investigated by varying flow rate, supplied power and gap spacing of plate electrodes.

  • PDF

붕소가 도핑된 다이아몬드전극을 이용한 오존발생기의 전기화학적 특성 (Eletrochemical Characteristics of Ozone Generator using Boron-doped Diamond Electrode)

  • 오원균;김규식;;;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.585-588
    • /
    • 2001
  • Thin. Boron-doped conducting diamond films are expected to be excellent electrodes for industrial electrolysis. Boron-doped conducting diamond films were used as anode for generating ozone gas by electrolysis of acidic solution. In this work, we have studied ozone generating system using Boron-doped Diamond electrode. Electrochemical cell and ozone generating system were designed for decreasing the temperature of the system. which was elevated during the reaction. by circulation of electrolyte in the system. In order to determine the ozone generation properties of diamond electrode. experimental conditions, electrolyte concentration, temperature, flow rate and reaction time were varied diversely. As a result, we could confirm that ozone gas was generated successfully and the performance of diamond electrode was stable while $PbO_2$ electrode was disintegrated. Actually we are found that ozone amount increased by lowering the temperature of electrolyte.

  • PDF

붕소가 도핑된 다이아몬드전극을 이용한 오존발생기의 전기화학적 특성 (Eletrochemical Characteristics of Ozone Generator using Boron-doped Diamond Electrode)

  • 오원균;김규식;;;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.585-588
    • /
    • 2001
  • Thin, Boron-doped conducting diamond films are expected to be excellent electrodes for industrial electrolysis. Boron-doped conducting diamond films were used as anode for generating ozone gas by electrolysis of acidic solution. In this work, we have studied ozone generating system using Boron-doped Diamond electrode. Electrochemical cell and ozone generating system were designed for decreasing the temperature of the system, which was elevated during the reaction. by circulation of electrolyte in the system. In order to determine the ozone generation properties of diamond electrode, experimental conditions, electrolyte concentration, temperature, flow rate and reaction time were varied diversely. As a result, we could confirm that ozone gas was generated successfully and the performance of diamond electrode was stable while PbO$_2$ electrode was disintegrated. Actually we are found that ozone amount increased by lowering the temperature of electrolyte.

  • PDF

입력가스의 유량변화와 첨가가스에 따른 고농도 오존발생특성 (High Concentration Ozone Generation Characteristics by Variation of Additional Gases and Flow Rates of Inlet Gas)

  • 박승록;이대희
    • 조명전기설비학회논문지
    • /
    • 제16권6호
    • /
    • pp.95-101
    • /
    • 2002
  • 고농도의 오존발생에 영향을 주는 많은 변수들이 존재한다. 이러한 변수들은 오존발생장치 설계시 매우 중요한 요소가 되고 설계전에 반드시 고려되어야 할 것들이다. 오존발생장치 설계 후에도 고농도 오존발생에 크게 영향을 주는 주변변수들이 있다. 본 연구에서는 오존발생에 영향을 주는 많은 주변변수들중에서 입력산소가스의 유량과 여기에 첨가되는 첨가가스가 고농도의 오존발생에 미치는 영향을 조사하였다. 결과적으로, 입력산소가스의 유량을0.75[LPM]~2.00[LPM]으로 변화시키면서 오존농도를 측정한 결과 1.25[LPM]에서 71145[ppm]의 최대오존발생량을 보여주었다. 입력산소가스에 첨가되는 질소가스의 유량을 0.0[vol%]~6.4[vol%]으로 변화시켜가면서 발생되는 오존농도를 측정한 결과 첨가되는 질소가스량이 0.8[vol%]인 경우 최대 73135[ppm]의 오존을 얻을 수 있었다. 이것은 순수산소만을 입력가스로 사용했을 때보다 최대오존발생량이 3[%]가량 증가한 결과이다. 입력산소가스에 첨가되는 아르곤가스의 유량을 0.0[vol%]~6.4[vol%]으로 변화시켜가면서 발생되는 오존농도를 측정한 결과 첨가되는 아르곤가스량이 0.8[vol%]인 경우 최대 67288[ppm]의 오존을 얻을 수 있었다.

고주파전원형 오존발생기의 방전 캡 변화 특성 (Characteristics of Ozonizer with Variation of Vaccum in Internal Electrode)

  • 이창호;전병준;이상근;송현직;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.381-385
    • /
    • 2003
  • In this paper, a co-axial type ozonizer varied with discharge gap was designed and manufactured for investigating $\circled1$ discharge characteristics with variation of output voltage power supply, flow rate and gap $\circled2$ ozone generation characteristics with variation of flow rate, gap and discharge power. pure oxygen was used as process gas of the co-axial type ozonizer. In this paper, a double cylindrical type superposed silent discharge type ozonizer which internal electrode can be produced a vacuum has been designed and manufactured. Discharge and ozone generation characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of internal electrode.

  • PDF

오존 접촉 반응기의 용존 오존 농도 및 페놀 분해에 미치는 운전변수의 영향 (Effects of Operating Parameters on Dissolved Ozone and Phenol Degradation in Ozone Contact Reactor)

  • 정재우;박정욱;이춘식
    • 대한환경공학회지
    • /
    • 제32권3호
    • /
    • pp.241-247
    • /
    • 2010
  • 오존 접촉 반응기에서 용존 오존 농도 및 페놀 제거에 미치는 운전변수의 영향에 대해 실험실 규모 실험을 수행하였다. 반응기로 가스상 오존이 공급되고 일정한 시간이 경과한 후에 용존 오존 농도는 포화 농도에 도달하였으며 포화 농도의 크기는 운전 변수에 의해 영향을 받는 것으로 나타났다. 수용액내의 오존은 높은 pH 조건에서 불안정하므로 용존 오존 농도는 용액의 초기 pH값이 증가함에 따라 감소하였다. 일정한 유량의 기체가 반응기로 공급되는 조건에서 가스상 오존 농도의 크기는 용존 오존의 포화농도에 중요한 영향을 미치며 일정한 농도의 가스상 오존이 공급될 때 가스 유량은 용존 오존이 포화되는 속도에 영향을 주는 것으로 관찰되었다. 페놀 제거에 미치는 운전변수의 영향은 각 운전변수가 용존 오존 농도에 미치는 영향과 밀접하게 관련되어 있는 것으로 나타났다. 용존 오존은 높은 pH 조건에서 빠르게 분해되어 페놀과의 반응성이 높은 자유라디칼을 생성시키므로 pH가 증가함에 따라 페놀 제거가 향상되었다. 동일한 pH 조건에서 가스상 오존 농도 및 가스 공급량의 증가는 용존 오존을 증가시킴으로써 페놀 분해를 증진시키는 것으로 나타났다. 메탄올의 주입은 OH 라디칼을 소비시켜 페놀 분해를 방해하는 것으로 관찰되었다.