• Title/Summary/Keyword: ozone destruction

Search Result 81, Processing Time 0.022 seconds

The Conceptions of Pre-service Elementary Teachers about Greenhouse Effect, Ozone Layer Depletion and Acid Rain (온실효과, 오존층 파괴, 산성비에 대한 예비 초등교사들의 개념)

  • 백남권
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.367-373
    • /
    • 2003
  • The focus of this study was to identify and describe environmental preconceptions held by pre-service elementary teachers about three issues : greenhouse effect, ozone layer depletion and acid rain. Two hundred and twenty nine pre-service elementary teachers participated in this study. A 36 question survey was created by one of the authors. The questions focused on the cause, effects, and interactions of three environmental issues greenhouse effect of one layer depletion and acid rain. Pre-service elementary teachers answered the questions on a Likert scale. An analysis of the survey data indicated that the majority of pre-service elementary teachers possess an array of incorrect conceptions about the causes and effects of the greenhouse effect ozone layer depletion, and acid rain. and also many pre-service elementary teachers thought that there were causal relationships among the increase in greenhouse effect, the destruction of ozone layer, and the increase of acid rain.

A Study on the Refrigerant Characteristics of the HFC-l52a, and Azeotrope Mixed with $CF_3 I$ (HFC-152a와 HFC-1523에 $CF_3 I$를 혼합한 공비혼합냉매 특성에 관한 연구)

  • 이종인;하옥남;김재열;이연신;권일욱
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.102-108
    • /
    • 2001
  • To prevent green house effect and destruction of an ozone layer, an ozone destruction potential(OBP) must be zero and a refrigerant for low global warming potential(GWP) is needed. HFC-l34a, in which hydrogen is mixed instead of chlorine is a refrigerant used for automobile conditioners and its destruction potential is ecologically zero. However, it is not consid- ered as a perfect substitutive refrigerant as its GWP is high. It is studied refrigerant mixtures in which HFC-l52a and $CF_3 I$ in HFC-l52a with low GWP and zero ODP are mixed by experimentally and concluded as follows: 1) With the variation of speed of compressor outside temperature and flow rate, 7he heat of evaporator and compressor and coefficient of perfor- mance was varied, and influenced the air conditioner. 2) The pressure of evaporator was decreased with increasing the speed of compressor and the pressure of evaporator with the refrigerant HFC-l52a was higher 24% than that of azotrope refrigerant mixed with $CF_3 I$

  • PDF

Overview of the Current State on Depletion of the Ozone Layer and Health Consequences (오존층파괴와 건강영향)

  • Cho, Yun-Syng
    • Journal of environmental and Sanitary engineering
    • /
    • v.4 no.2 s.7
    • /
    • pp.1-14
    • /
    • 1989
  • There is increasing concern that depletion of the ozone layer may have important health consequences. Each $1\%$ decline in ozone concentration is expected to cause a $2\%$ increase in ultraviolet radiation this in turn has been suggested to lead to up to a $4-6\%$ increase in certain kinds of skin cancer. In Colorado state, malignant melanoma patients increased form 7.4 cases per 100,000 to 12.6 per 100,000 in the general population between 1979 and 1985. In Australia, 4,000 new melanomas are diagnosed each year and 800 people die every year from melanoma. Strong international controls CFCs production are necessary to lower the destruction of ozone in the stratosphere. Only then will the increase in ultraviolet radiation to the skin be halted and the incidence and mortality from melanomas be reduced.

  • PDF

The Conceptions of High School Students about Acid Rain, Ozone Layer, and Greenhouse Effect (산성비, 오존층, 온실 효과에 대한 고등학생들의 개념)

  • Han, Jae-Young;Jeong, Yeong-Seon;Noh, Tae-Hee
    • Journal of The Korean Association For Science Education
    • /
    • v.20 no.3
    • /
    • pp.364-370
    • /
    • 2000
  • In this study, 10th-grade students' conceptions concerning acid rain, ozone layer, and greenhouse effect were investigated. A conception test that asked to explain about the three concepts and the relationships among them was administered to 137 students. Analysis of their responses indicated that students had lack of understanding about the definition of acid rain, the difference between greenhouse effect and global warming, and how to prevent the increase in greenhouse effect. They also confused ozone layer with greenhouse effect. Many students thought that there were causal relationships among the increase of acid rain, the destruction of ozone layer, and the increase in greenhouse effect.

  • PDF

Effects of Ionizing Energy and Ozone Treatments on the Microbial Decontamination and Physicochemical Properties of Aloe Powders and Bee Pollen

  • Yook, Hong-Sun;Chung, Young-Jin;Kim, Jung-Ok;Kwon, Oh-Jin;Kim, Sung;Byun, Myung-Woo
    • Preventive Nutrition and Food Science
    • /
    • v.2 no.2
    • /
    • pp.89-95
    • /
    • 1997
  • The comparative effects of gamma irradiation an ozone treatment on the microbiological and physicochemical qualities were investigated for the improvement of hygienic quality of aloe powder and bee pollen. Gamma irradiation at 7.5~10kGy could reduce total aerobic bacteria, molds and coliforms below detection levels, but ozone treatment up to 18 ppm for 8hr was not sufficient to eliminate the microorganisms from aloe powder and bee pollen. The physicochemical properties such as fatty acid an amino acid compositions, mineral content, TBA value, barbaloin and pigment contents were not significantly changed by gamma irradiation, whereas ozone treatment caused significant changes in fatty acid composition, lipid oxidation and destruction of barbaloin and natural pigments.

  • PDF

Effect of Ozone Injection on Dewaterability and Thickening of Sewage Sludge (하수 슬러지 농축 및 탈수성에 미치는 오존의 영향)

  • Hwang, Kyeoung-Sa;Kim, Moon-Ho;Bae, Yoon-Sun;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.800-808
    • /
    • 2005
  • It is required to propose an alternatives for appropriate sludge treatment owing to persistent construction of sewage treatment plant and increase of sewage sludge quantity. In order to treat sludge more efficiently, the methods which reduce the cost of sludge treatment have been studied such as sludge reduction and conditioning. Especially ozone treatment reduces solid quantity and improves separation of solid-liquid at the same time. Therefore ozone treatment have a positive effect on reduction and stabilization of sludge. So, this study applied ozone to sewage sludge and induced cell destruction of sludge. By comparing with the correlation between thickening and dewatering, and evaluating moisture content and solubilization of cake, this study verificates the effect of process improvement for ozone pre-treatment. In J-STP case, according to ozone dose solid flux increased about 12 times from $1kg/m^2{\cdot}h$ to $12kg/m^2{\cdot}h$. Also this plant were capable to shorten thickening time from 40 minutes to 6~7 minutes. Thus it is expected to reduce volume and retention time of thickener. On pH effect factor, dewatering at pH4 was more than at pH11, $3.05{\times}10^{11}$ and $3.82{\times}10^{11}(m/kg)$. But effect of pH was analogous to ozone, $2.81{\times}10^{11}(m/kg)$. The effect of pH on thickening was similar to law sludge, $0.68(kg/m^2{\cdot}h)$, and the effect of ozone injection on thickening was the biggest, $3.45(kg/m^2{\cdot}h)$. The COD solubilization rate improved from about 5 to 30%. So it is judged that we are able to utilize most solubilized sludge to another sewage treatment plants.

Application of Photocatalytic Reaction Using TiO2 Thin Film (TiO2 박막을 이용한 광촉매반응의 응용)

  • Kim, Yeong-Kwan;Kim, Sung-Ho;Kim, Dong-Hyun
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.249-254
    • /
    • 1997
  • Photocatalytic reaction using $TiO_2$ thin film was applied for the inactivation of coliform bacteria and the degradation of formic acid. UV processes coupled with and without $TiO_2$ were tested for the river water samples. It took 5 and 15 minutes, respectively, to obtain 99% destruction of coliform bacteria in the total coliform test, which demonstrated the effectiveness of the photocatalytic reaction. Complete degradation of formic acid determined by TOC analysis was observed in 20 minutes by ozone/photocatalysis, while formic acid was degraded as little as about 20% during the first 100 minutes by ozone treatment alone. When ozone was supplied to the $TiO_2/UV$ system, however, it provided a synergetic effect for the degradation of formic acid.

  • PDF

A Study on the characteristics and Development of Power supply for ozonizer (오존 발생기용 전원 장치 개발 및 특성에 관한 연구)

  • Kim, Jong-Hae;Bae, Sang-June;Lee, Young-Sik;Jo, Gee-Yeun;Jeong, Seung-Kyun;Lee, Bong-Seop
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2069-2071
    • /
    • 1997
  • The power semiconductor switching devices(PSSD) continuously developed, Power Electronic Technology using PSSD is gradually extended. The high frequency inverter to generate the large power high frequency subject to power electronic technology pursuit various application. Also, in emboss with environmental destruction problem cause the atmosphere and the water pollution to growth of the commercial society, the research in favor of cleansing environmental a pollutant actively proceed. This paper describe study on the ozone generation power supply using the high frequency electric field method and the lamp type ozone generator using photochemistry, one of method of gene-rate ozone.

  • PDF

Effect on the Hydrogen Peroxide in the Ozonation of Ammonia (오존에 의한 암모니아 산화시 과산화수소가 미치는 영향)

  • 박문숙;안재동;노봉오
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • Ammonia is used in the manufacture of fertilizers, refrigerants, stabilizers and many household cleaning agents. These wide applications resulted in ammonia contamination in water. Ammonia can be removed from water by physical, biological, and chemical methods. Ozonation is effictive in the treatment of water with low concentration of ammonia. This study is undertaken to provide kinetic data for the ozonation of ammonia with or without hydrogen peroxide. The results were as follows; The destruction rate of ammonia increased gradually with the influent hydrogen peroxide concentration up to 0.23 mM and inhibited in the range of 0.23~11.4mM, and the maximum removal rate of ammonia achieved at 0.23mM of hydrogen peroxide, and the overall kinetics was first order. The combination effect of hydrogen and ozone to oxide ammonia in aqueous solution was better than ozone alone. The reacted ammonia was converted completely to nitrate ion.

  • PDF

Studies on the Effects of Ozone Gas in Paddy Rice;1. Effects of Ozone Gas on Growth Stage of Rice (수도생육(水稻生育)에 대(對)한 Ozone 가스의 영향(影響)에 관(關)한 연구(硏究);1. Ozone 가스에 대(對)한 수도생육시기별(水稻生育時期別) 영향(影響))

  • Kim, Bok-Young;Cho, Jae-Kyu;Park, Young-Sun
    • Korean Journal of Environmental Agriculture
    • /
    • v.1 no.2
    • /
    • pp.123-128
    • /
    • 1982
  • This study was carried out to investigate the effect of ozone gas on paddy rice at the different growth stage. Seokwang variety of rice plant was exposed to 0.5 ppm ozone gas for 4 hours at rooting, maximum tillering, ear formation and heading stages. after ozone gas fumigation, damage symptom, percentage of destroyed leaf, chlorophyll content and peroxidase activity of rice plant were observed. The results obtained are as follows. 1) Typical symptom of ozone gas damage appeared greyish or reddish brown subtle spots within rice leaf vein. 2) Yield loss by ozone gas exposure at different growth stage was in the order of maximum tillering stage>rooting stage>ear formation stage>heading stage. 3) Chlorophyll damage and leaf destruction was the highest at maximum tillering stage, while damage of leaf and chlorophyll were not found at heading stage. 4) The damage by ozone gas fumigation was higher at the growth stage with higher N content in plant, and N content was decreased after ozone gas exposure.

  • PDF