• 제목/요약/키워드: ozone consumption

검색결과 70건 처리시간 0.02초

오존을 이용한 하수슬러지의 감량화와 안정화 (Reduction and Stabilization of Sewage Sludge by Ozonation)

  • 이창근;황은주;강성재;빈정인;이병헌
    • 한국물환경학회지
    • /
    • 제20권3호
    • /
    • pp.290-295
    • /
    • 2004
  • In this study, ozone was adopted for the reduction and stabilization of waste sludge from the municipal sewage treatment plant. The waste sludge used in the experiments was primary sludge, excess sludge and a mixture of the two. The sludge cells and flocs were disrupted by ozonation resulting in the reduction of TSS and VSS concentrations. In the case of the primary sludge with a concentration of 20 gTS/L, the TSS and VSS concentrations were reduced 28%, 33% and the TCOD concentration was reduced 20% respectively. The consumption of ozone was $0.18gO_3/gSS$. In the case of the excess sludge with a concentration of 7.5 gTS/L, the TSS and VSS concentrations were reduced 37%, 41%, and the TCOD concentration was reduced 19% respectively. The consumption of ozone was $0.33gO_3/gSS$. In the case of the mixed sludge of 9.3 gTS/L, the TSS and VSS concentrations were reduced by 45%, 53%, and the TCOD was reduced 26% respectively. The desirable consumption of ozone was $0.27gO_3/gSS$. As ozonation proceeded, the level of SCOD increased due to the release of intracellular materials. However TCOD was reduced due to mineralization resulting from the transformation of organic materials to inorganic materials.

DOF 공정에 의한 정수처리 효과 (Effect of Drinking Water Treatment by DOF(Dissolved Ozone Flotation) System)

  • 이병호;송원철
    • 대한환경공학회지
    • /
    • 제30권7호
    • /
    • pp.743-750
    • /
    • 2008
  • 본 연구에서는 용존오존부상법(Dissolved Ozone Flotation; DOF)을 이용한 정수처리 효과를 파악하기 위하여 적정 오존 주입 농도와 오존 주입 농도별 처리 특성에 대해서 연구하였으며, 또한 용존공기부상법(Dissolved Air Flotation; DAF) 및 중력식 침전법(Conventional Gravity Sedimentation; CGS)과 DOF의 처리 성능을 비교하였다. 최적 오존 주입 농도를 산정하기 위한 실험에서 최적 오존 주입농도는 2.7 mg/L로 나타났으며, 오존 주입 농도가 증가할수록 탁도 및 KMnO$_4$ 소모량, UV$_{254}$ 흡수도, TOC 등과 같은 제거효율이 낮아지는 것으로 나타났다. DOF와 DAF, CGS의 처리성능을 비교한 결과 오존 주입 농도 2.7 mg/L로 운전한 DOF시스템의 탁도 제거효율은 88.9%, 유기물질 항목의 경우 KMnO$_4$ 소모량은 62.9%, TOC 47%, 그리고 UV$_{254}$ 흡수도 77.3% 그리고 THMFP 제거율의 경우 51.6%로 다른 두 공정보다 높거나 비슷하게 나타났다. 따라서 응집 부상 공정과 오존 산화 공정이 하나의 반응기에서 일어나는 DOF 시스템은 정수처리시설의 소유부지 감소와 기존 CGS 시스템에서 처리가 어려운 조류 및 용존성 유기물질의 제거를 통해 소독부산물의 생성을 감소시킴으로 향후 고도정수처리시스템으로 적용 가능성이 충분한 것으로 판단된다.

고전압 전극 두께와 집진판 간격에 따른 전기집진기의 미세먼지 집진효율 및 오존발생 특성 (Characteristics of particulate matter collection efficiency and ozone emission rate of an electrostatic precipitator by thickness of high-voltage electrode and distance of collection plates)

  • 이재인;우상희;김종범;이승복;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.171-180
    • /
    • 2018
  • To optimize the shape of the electrostatic precipitator for the removal of particulate matter in subway environments, the wind-tunnel experiments were carried out to characterize collection efficiency and ozone emission rate. As a standardized parameter, power consumption divided by the square of flow velocity, was increased, the $PM_{10}$ collection efficiency increased. If the standardized parameter is higher than 1.0 due to high power consumption or low flow velocity, increase in thickness of electrodes from 1 to 2 mm, or increase in distance of collection plates from 5 to 10 cm did not change the $PM_{10}$ collection efficiency much. Increase in thickness of high-voltage electrodes, however, can cause decrease in $PM_{10}$ collection efficiency by 28% for low power consumption and high flow velocity. The ozone emission rate decreased as distance of collection plates became wider, because the ozone emission rate per unit channel was constant, and the number of collection channels decreased as the distance of collection plates increased. When the distance of collection plates was narrow, the ozone emission rate increased with the increase of the thickness of electrodes, but the difference was negligible when the distance of collection plates was wide. It was found that the electrostatic precipitator having a thin high-voltage electrodes and a narrow distance of collection plates is advantageous. However, to increase the thickness of high-voltage electrodes, or to increase the distance of collection plates is needed, it is necessary to increase the applied voltage or reduce the flow rate to compensate reduction of the collection efficiency.

낙동강 상수원수의 오존처리 효과 I. 회분식 오존처리에 의한 수처리효과 (Effect of Ozone Treatment for Nakdong River Raw Water I. Efficiency of Water Treatment by Conducting Batch Test of Ozonation Experiments)

  • 조주식;임영성;이홍재;허종수
    • 한국환경과학회지
    • /
    • 제10권6호
    • /
    • pp.393-399
    • /
    • 2001
  • This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation. for raw water, Nakdong River was used. By conducting batch ozonation test, the following results were obtained. when ozone dosage of 5mg/$\ell$was used, preozonation of raw water reduced turbidity, KMnO$_4$consumption, DOC(dissolved organic carbon), UV254 absorbance, THMFP(trihalomethane formation potential) as much as 3.9NTU, 5.5mg/$\ell$, 1.15mg/$\ell$, 0.112 and 0.065mg/$\ell$, respectively. In case of postozonation of sand filtered water, water quality was also improved with decrease in turbidity, KMnO$_4$consumption, DOC, UV254 absorbance and THMFP at the amount of 0.08NTU, 2.6mg/$\ell$, 0.88mg/$\ell$, 0.042 and 0.018mg/$\ell$, respectively. On the other hand, contents of dissolved oxygen increased at the level of 1.3mg/$\ell$ after preozonation process and 1.0mg/$\ell$ after postozonation process. The effect of ozone dosage was higher than that of its contact time for the removal of the pollutants.

  • PDF

Application of ozone treatment in cooling water systems for energy and chemical conservation

  • Ataei, Abtin;Mirsaeed, Morteza Ghazi;Choi, Jun-Ki;Lashkarboluki, Reza
    • Advances in environmental research
    • /
    • 제4권3호
    • /
    • pp.155-172
    • /
    • 2015
  • In this study, a complete set of recirculating cooling water system and the required instruments were built in a semi-industrial-scale and a 50 g/h ozone generation plant and a chlorine system were designed for cooling water treatment. Both chlorination and ozonation treatment methods were studied and the results were analyzed during two 45-days periods. The concentrations of ozone and chlorine in recirculating water were constant at 0.1 mg/lit and 0.6 mg/lit, respectively. In ozone treatment, by increasing the concentration cycle to 33%, the total water consumption decreased by 26% while 11.5% higher energy efficiency achieved thanks to a better elimination of bio-films. In case of Carbon Steel, the corrosion rate reached to 0.012 mm/yr and 0.025 mm/yr for the ozonation and chlorination processes, respectively. Furthermore, consumptions of the anti-corrosion and anti-sedimentation materials in the ozone cooling water treatment were reduced about 60% without using any oxidant and non-oxidant biocides. No significant changes in sediment load were seen in ozonation compared to chlorination. The Chemical Oxygen Demand of the blow-down in ozonation method decreased to one-sixth of that in the chlorination method. Moreover, the soluble iron and water turbidity in the ozonation method were reduced by 97.5% and 70%, respectively. Although no anaerobic bacteria were seen in the cooling water at the proper concentration range of ozone and chlorine, the aerobic bacteria in chlorine and ozone treatment methods were 900 and 200 CFU/ml, respectively. The results showed that the payback time for the ozone treatment is about 2.6 years.

저온 플라즈마와 활성슬러지 복합 공정에서 체류시간 변화가 악취 저감 및 슬러지 가용화에 미치는 영향 (Effects of Retention Time on the Simultaneous of Odor Removal and Sludge Solubilization Using a Non-Thermal Plasma System)

  • 남궁형규;황현정;송지현
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.815-824
    • /
    • 2011
  • In this study, a non-thermal plasma system was employed to simultaneously remove odorous compounds and organic sludge. The system consisted of two reactors; the first one was the non-thermal plasma reactor where ozone was produced by the plasma reaction and the ozone oxidized hydrogen sulfide, the model odorous compound, and then the ozone-laden gas stream was introduced to the second reactor where wasted sludge was disintegrated and solubilized by ozone oxidation. In this study, the gas retention time (GRT) and the hydraulic retention time (HRT) were changed in the two-reactor system, and the effects of GRT and HRT on reduction efficiencies of odor and sludge were determined. As the GRT increased, the ozone concentration increased resulting in an increasing efficiency of hydrogen sulfide removal. However, the overall ozone loading rate to the second sludge reactor was the same at any GRT, which resulted in an insignificant change in sludge reduction rate. When HRTs in the sludge reactor were 1, 2, 4 hours, the sludge reduction rates were approximately 30% during the four-hour operation, while the rate increased to 70% at the HRT of 6 hours. Nevertheless, at HRTs greater than 4 hours, the solubilization efficiency was not proportionally increased with increasing specific input energy, indicating that an appropriate sludge retention time needs to be applied to achieve effective solubilization efficiencies at a minimal power consumption for the non-thermal plasma reaction.

Ozone에 의한 유류오염토양 복원 연구 (II) : 토양 컬럼상에서의 오존 산화 (Ozone-Enhanced Remediation of Diesel-Contaminated Soil (II): A Column Study)

  • 최희철;유도윤;임형남;김광수
    • 대한환경공학회지
    • /
    • 제22권10호
    • /
    • pp.1825-1832
    • /
    • 2000
  • 유류화합물(디젤)로 오염된 불포화층 토양에 대한 현장오존복원공정의 기초연구로, 토양조건에 따른 오존의 이동과 분해, 디젤과의 반응경향을 조사하였다. 건조상태에서 유기물을 제거한 모래와 glass beads 충진컬럼에서 기상 오존의 분해를 조사한 결과 일차반응으로 가정시 반응 속도상수값(k)이 각각 $9.9{\times}10^{-3}s{^{-1}}$$4.3{\times}10^{-4}s{^{-1}}$로 나타나 모래의 경우 철 (Fe), 망간(Mn) 성분 등의 촉매작용으로 25배 가량 반감기가 짧은 것을 확인할 수 있었다. 디젤로 오염시킨 현장 토양과 모래를 컬럼에 충진하여 동일조건하에서 오존주입시 토양입자의 크기와 유 무기물의 함량 차에 의한 오존이동상에 지체효과 및 소모량의 차이를 관찰하였고, 50mL/min의 유속에서 공기만을 주입시 DRO(diesel range organic) 기준 초기 디젤총량($800{\pm}50mg/kg$)의 30%가 제거된데 비해 오존을 6mg/min으로 16시간 주입한 결과 각각 80% 이상이 제거되었다. 오존주입시간에 따라 컬럼의 유출 입부에 잔류하는 TPH(total petroleum hydrocarbon)와 DRO 중 aliphatic계열 8개 물질들의 농도를 비교/분석한 결과, 낮은 탄소수 물질들로의 전환과정을 거쳐 유체의 흐름에 따라 컬럼 밖으로 이동됨을 확인하였고, 토양내 수분함량은 오염 토양복원에 오존을 적용시 중요한 인자임을 확인하였다.

  • PDF

A Design Technology of Ceramic Tube for High Efficiency Ozone

  • Cho, Kook-Hee;Kim, Young-Bae;Lee, Dong-Hoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권3호
    • /
    • pp.77-80
    • /
    • 2003
  • An innovative ozonizer has been developed using a high frequency, surface discharge and a high purity Ti-Si-AI ceramic catalyst as a dielectric component. Using a type of thin film, a thin cylindrical compound ceramic catalyst layer was adhered to the outside surface of its inner electrode. An alternating current (AC) exciting voltage with frequencies from 0.6 KHz to 1.0 KHz and peak-to-peak voltages of 4-6 ㎸ was applied between the electrodes to produce a stable high-frequency silent discharge. A substantial reduction of the exciting voltage was also enabled by means of a thin Ti-Si-Al ceramic catalyst tube. As a result, the ozonizer can effortlessly obtain the required ozone concentration (50-60 g/$m^2$ for oxygen) and high ozone efficiency consumption power (180 g/kWh for oxygen) with-out the assistance of any particular methods. For purposes of this experiment, oxygen gas temperature was set at 2$0^{\circ}C$, with an inner reactor pressure of 1.6 atm at 600 Hz and a flow rate of 2 l/min.

잉여슬러지 가용화를 위한 마이크로버블 오존 이용에 관한 연구 (A Study on the Solubilisation of Excess Sludge using Microbubble Ozone)

  • 이순화;정계주;권진하;이세한
    • 대한환경공학회지
    • /
    • 제32권4호
    • /
    • pp.325-332
    • /
    • 2010
  • 본 연구에서는 오존을 이용한 잉여슬러지의 가용화 실험을 실시하였다. 오존의 접촉효율을 높이기 위해 마이크로버블화된 오존(이하 마이크로버블 오존이라 함)을 이용하였으며, 생성된 마이크로버블 오존의 사이즈는 평균 직경 30 ${\mu}m$ 정도였고, 40 ${\mu}m$ 이하가 전체의 약 90% 정도를 나타내었다. 마이크로버블 오존을 이용한 슬러지 처리에 있어서는 슬러지 농도에 상관없이 오존주입율을 0.34 g $O_3/g$ SS 이하로 주입할 경우, 폐오존의 발생 없이 오존소모율이 100%인 것으로 조사되었다. 각 농도별 슬러지 처리에 있어서 슬러지의 초기 SS 농도를 6,447 mg/L, 5,557 mg/L, 3,180 mg/L, 1,092 mg/L 및 515mg/L로 하였을 경우, 동일한 오존주입율에 있어서 초기 SS의 농도가 증가할수록 제거되는 SS량이 증가하는 경향을 나타내어, 오존의 산화효율을 높이기 위해서는 초기 SS의 농도가 높은 슬러지를 처리하는 것이 효과적이었다. 한편, 슬러지의 복합 처리로서 산과 알칼리 그리고 오존처리를 검토한 결과, 오존의 전처리로서 산처리를 이용하는 것이 알칼리처리에 비해 효과적이었으며, 슬러지에 주입하는 황산의 농도를 0.01 N로 하고, 오존주입율 0.05 g $O_3/g$ SS로 처리한 경우, 제거된 SS의 양은 153.9 g으로 오존단독처리시 81.2 g에 비해 1.9배의 많은 양이 제거되었다.

수영장 욕조수의 소독방법에 따른 THMs 발생 특성 (The Characteristics of THMs Production by Different Disinfection Methods in Swimming Pools Water)

  • 이진;하광태;조경덕
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.171-178
    • /
    • 2006
  • The objectives of this study were to investigate the formation of trihalomethanes(THMs) and to compare the concentration level of THMs of swimming pools water by different disinfection methods such as chlorine, ozone-chlorine, and salt brine electrolysis generator (SBEG). The concentration of chloroform was the highest in the chlorine system, and the SBEG was the highest in the production of bromodichloromethane (BDCM), dibromochloromethane (DBCM) and bromoform. The average concentration of total trihalomethanes (TTHMs) in three disinfection systems were $64.5{\pm}27.4mg/l(SBEG),\;43.8{\pm}22.3mg/l(chlorine)$, and $30.6{\pm}16.1mg/l(ozone-chlorine)$, respectively. In chlorine and ozone-chlorine disinfection system, chloroform concentration was highest, followed by BDCN, then DBCM. In the SBEG, TTHMs was composed of 42% of chloroform, 28.9% of bromoform, 15.1% of BDCM and 14% of DBCM, respectively. The strongest correlation was obtained in the levels of chloroform and TTHMs in chlorine, and ozone-chlorine disinfection systems from both indoor and outdoor swimming pools ($r=0.989{\sim}0.999$, p<0.01). In the SBEG, the levels of BDCM and TTHMs showed a good correlation (r=0.913, p<0.01). In chlorine and ozone-chlorine disinfection systems at indoor swimming pools, pH, TOC and $KMnO_4$ consumption showed strong correlation with chloroform and TTHMs concentrations (p<0.01). In the SBEG, pH and TOC were also strongly correlated with chloroform (p<0.01). pH and TTHMs were correlated as well (p<0.05).