• 제목/요약/키워드: oxygen gas sensor

검색결과 97건 처리시간 0.021초

실화가스 흐름에 대한 광역 산소센서의 응답특성 및 이를 이용한 실화감지 (The Response of a Wide-Range Oxygen Sensor to the Flow of Misfired Gas and Its Application for the Misfire Detection)

  • 정영교;최상민;배충식;명차리
    • 한국자동차공학회논문집
    • /
    • 제8권2호
    • /
    • pp.41-49
    • /
    • 2000
  • To understand the signal fluctuation of a wide-range oxygen sensor installed at the exhaust confluence point, when a misfiring is triggered in a cylinder, the steady state and the transient response characteristics of the sensor to the flow of the misfired gas were investigated quantitatively. It was recognized that the steady state output voltage of the sensor increased higher when it contacted the misfired gas even though the fueling condition was the same as the normal combustion case and this characteristic enabled the application of the wide-range oxygen sensor for the misfire detection. The transient response was compared at different engine speeds and it was found that the response speed increased with the engine speed. The signal fluctuation was also estimated quantitatively, using these steady state and transient response of the sensor, and the estimated signal showed satisfactory correlation with the measurements.

  • PDF

마취기용 인공호흡기의 압력 측정값의 보정을 위한 센서 출력의 데이터 처리 (Data processing of sensor output for correction of pressure measurement value of an anesthesia ventilator)

  • 박영준;이종수;김영길
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.1067-1070
    • /
    • 1999
  • Anesthesia gas to pour to patients affects the flow and volume as the pressure difference of an oxygen and an anesthesia gas. An anesthesia gas, being injurious and polluting an environment, must control the pressure of an oxygen gas because of being used by closing up tight. But a pressure sensor to use for measuring an oxygen gas appears other pressure as the characteristic and the error difference of elements to use for implementing an system. A medical machine such as an anesthesia ventilator must be accurate because of using for the person's body. So we intend to implement an system for a sensor pressure measurement not to be change regardless of an environment. This papers is the target that a sensor pressrue measurement to be changed in environment is equal to actual sensor pressure measurement. So an implemented system is using analog filter and digital filter to reduce a noise. And we are using auto-zeroing and calibration to correct a sensor pressure which is changed in environment. Through such a process we increase the accuracy and the confidence of an anesthesia ventilator by controlling the flow of an anesthesia gas.

  • PDF

자동차 배기계용 산소센서 내부유동 특성 평가 (Evaluation of Inner Flow Characteristics of Oxygen Sensor for Vehicle Exhaust System)

  • 한대광;서호철;이정재;강정호;한승호
    • 한국기계가공학회지
    • /
    • 제11권2호
    • /
    • pp.47-54
    • /
    • 2012
  • An oxygen sensor installed in vehicle exhaust systems enables to measure the amount of oxygen in the exhaust gas, in which the measured data are collected and analyzed in ECU(Engine Control Unit). The oxygen sensor is exposed to the high speed exhaust gas at high temperature circumstance, so that protection caps are required not only to protect the susceptible measuring part, but also to provide the real time measurement without time delay. In this study, a new oxygen sensor with one protection cap was proposed, and the CFD analysis was carried out in order to compare the performance characteristics, such as flow speed and ratio of AOA(Age of Air), for the conventional and new oxygen sensor. The numerical results of CFD analysis provided the flow speed of 1.34m/s and the ratio of AOA of 3.43. The similar features obtained from the numerical results showed that the new oxygen sensor guarantees the same performance characteristics of the conventional ones.

다전극 산소 센서를 이용한 고분자 막의 산소 투과도 측정 장치 연구 (A Study on the Apparatus for Measuring Oxygen-Permeability of Membranes with a Multi-Electrode Oxygen Sensor)

  • 정일손;정재칠;김태진
    • 센서학회지
    • /
    • 제21권3호
    • /
    • pp.229-234
    • /
    • 2012
  • The existing permeability measurements based on pressure differential between the polymer membrane that is permeable to measure the amount of oxygen used, but these methods must be kept in a vacuum, and the measurement of the membrane with low permeability in the membrane is too time consuming. In recent years by using electrochemical method polymer membrane currents caused by the amount of oxygen is a measure of how much is used. In this study, apparatus consisting of one anode and six cathodes for multi-oxygen permeability tester used the same number of membranes produced by electrochemical oxygen permeation characteristics. In this study, one silver/silver chloride anode electrochemical method with a hexagonal sensor to put various kinds of polymer membranes with the six oxygen permeability for simultaneous measurement in real-time systems. Six cathodes (Pt), and one of the coil-shaped anode (Ag/AgCl) to form a hexagonal one of the polarographic oxygen sensor in a single measurement system by six sensors. Each sensor for making hexagonal specificity of the sensor to compensate for the conditions obtained in a pure nitrogen gas and pure oxygen gas conditions. With this study, self-developed hexagonal sensor capable of measuring sensors and oxygen permeability tester, for a multi-six different oxygen permeability characteristics of the membrane measured at the same time.

산소 분위기 열처리에 따른 ZnO 나노선의 상온 영역에서의 수소가스 검출 특성 향상 (Enhanced Hydrogen Gas Sensing Properties of ZnO Nanowires Gas Sensor by Heat Treatment under Oxygen Atmosphere)

  • 강우승
    • 한국표면공학회지
    • /
    • 제50권2호
    • /
    • pp.125-130
    • /
    • 2017
  • ZnO nanowires were synthesized and annealed at various temperatures of $500-800^{\circ}C$ in oxygen atmosphere to investigate hydrogen gas sensing properties. The diameter and length of the synthesized ZnO nanowires were approximately 50-100 nm and a few $10s\;{\mu}m$, respectively. $H_2$ gas sensing performance of the ZnO nanowires sensor was measured with electrical resistance changes caused by $H_2$ gas with a concentration of 0.1-2.0%. The response of ZnO nanowires at room temperature to 2.0% $H_2$ gas is found to be two times enhanced by annealing process in $O_2$ atmosphere at $800^{\circ}C$. In the current study, the effect of heat treatment in $O_2$ atmosphere on the gas sensing performance of ZnO nanowires was studied. And the underlying mechanism for the sensing improvement of the ZnO nanowires was also discussed.

Preparation of Ru-C Nano-composite Film by MOCVD and Electrode Properties for Oxygen Gas Sensor

  • Kimura, Teiichi;Goto, Takashi
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.358-359
    • /
    • 2006
  • Ru-C nano-composite films were prepared by MOCVD, and their microstructures and their electrode properties for oxygen gas sensors were investigated. Deposited films contained Ru particles of 5-20 nm in diameter dispersed in amorphous C matrix. The AC conductivities associating to the interface charge transfer between Ru-C composite electrode and YSZ electrolyte were 100-1000 times higher than that of conventional paste-Pt electrodes. The emf values of the oxygen gas concentration cell constructed from the nano-composite electrodes and YSZ electrolyte showed the Nernstian theoretical values at low temperatures around 500 K. The response time of the concentration cell was 900 s at 500 K.

  • PDF

불화물을 이용한 산소센서의 제조및 특성 (Fabrication and Characteristics of Oxygen Gas Sensor using Fluoride Compaunds)

  • 이재현;홍영호;장동근;이병택;김태훈;이덕동
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 1993년도 추계 학술발표 강연 및 논문 개요집
    • /
    • pp.69-71
    • /
    • 1993
  • Fluoride compound potentiometric cell oxygen sensors were fabricated for the measurement of oxygen pressure in the low temperature range (300。K-500。K). The disk type sensors consist of a reference Air(0$_2$):Ag, a solid electrolyte SrF$_2$, and a sensing metel Ag electrode. And the buried reference electrode type sensor have a NiO/Ni reference electrode. The open circuit emf of the cell showed high sensivity to oxygen gas (60mv) at the measuring temperature 20$0^{\circ}C$. Also, The buried reference electrode type sensor showed 30mv from 1% to 10% oxygen pressure range.

  • PDF

${Li_2}{CO_3}-{Li_3}{PO_4}-{Al_2}{O_3}$계의 고체 전해질 및 ${LiMn_2}{O_4}$의 기준전극을 사용한 $CO_2$ 가스센서 (Solid-State $CO_2$ Sensor using ${Li_2}{CO_3}-{Li_3}{PO_4}-{Al_2}{O_3}$ Solid Electrolyte and ${LiMn_2}{O_4}$ as Reference Electrode)

  • 김동현;윤지영;박희찬;김광호
    • 한국세라믹학회지
    • /
    • 제37권8호
    • /
    • pp.817-823
    • /
    • 2000
  • A solid-state electrochemicall cell for sensing CO2 gas was fabricated using a solid electrolyte of Li2CO3-Li3PO4-Al2O3 mixture and a reference electrode of LiMn2O4. The e.m.f. (electromotive force) of sensor showed a good accordance with theoretical Nernst slope (n=2) for CO2 gas concentration range of 100-10000 ppm above 35$0^{\circ}C$. The e.m.f. of sensor was constant regardless of oxygen partial pressure at the high temperature above 0.1 atm. It was, however, a little depended on oxygen partial pressure as the pressure decreased below 0.1 atm. The oxygen-dependency of our sensor gradually disappeared as the operating temperature increased. The sensing behavior of our CO2 sensor was affected by the presence of water vapor, but its effect was small comparing with other sensors.

  • PDF

$MgO-Cr_2O_3-TiO_2$ 산화물의 가스감지 특성 (Gas Sensing Properties of $MgO-Cr_2O_3-TiO_2$ Oxide)

  • 양천회;홍필선;유일증;임병오
    • 한국안전학회지
    • /
    • 제1권1호
    • /
    • pp.21-26
    • /
    • 1986
  • Gas sensing materials for detecting inflammable gas such as alcohol, propane, acetic acid, carbon monoxide, hydrogen were developed by utiliting $MgO-Cr_2O_3-TiO_2$ system. Between 30$0^{\circ}C$ and 50$0^{\circ}C$, reversible chemisorption becomes dominant and the electrical canduction of P-type semiconductive with the gas chemisorption. The ceramic sensor exhibits a high sensitivity to particular reducing gas such as alcohol, whereas propane and butane have little effect on the resistivity. The time response of adsorption is estimated to be about 20 sec. On the other hand, the desorption process, which corresponds to oxidation due to oxygen adsorption, take more than 60 sec. Thus the ceramic sensor can be used as a alcohol sensor in an ambient aunosphere. As the oxygen concentration is increased from 0.1 to 10 precent($10^3-10^6ppm$), the resistance decreases rapidly but stabilizes at higher concentration.

  • PDF

이동식 적외선 가스히터의 배기가스현상에 대한 실험적 연구 (Experimental Study on the Flue Gas Phenomena in Infrared Mobile Heaters)

  • 김영규;류근준
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.119-125
    • /
    • 1996
  • The experimental work is performed to obtain content levels and characteristics of flue gas in infrared mobile heaters for butane gas with varying the chamber size and its room temperature. The results showed that the oxygen depletion sensor device is operated at 18.3% of oxygen content. And the relation of oxygen content and carbon dioxide content in an enclosed space show linear aspect, but the content rate of carbon monoxide occurs at random without the level of oxygen content and carbon dioxide content.

  • PDF