• Title/Summary/Keyword: over-current

Search Result 5,952, Processing Time 0.042 seconds

Nonlinear Interaction among Wave, Current and Submerged Breakwater (파랑-흐름-잠제의 비선형 상호간섭 해석)

  • Park, Su-Ho;Lee, Jung-Hoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.1037-1048
    • /
    • 2016
  • In this study, nonlinear wave interaction in the presence of a uniform current is studied using numerical model, named CADMAS-SURF which is based on the Navier-Stokes equations coupled with Volume of Fluid for tracking free surface deformation. The original CADMAS-SURF developed for interaction of wave with structure is modified/extended to simulate nonlinear fluid dynamic motions within wave-current coexisting field. The capability of Numerical Wave-Current Tank (NWCT) in this study is validated by comparing with available existing laboratory experiments for both wave-following and wave-opposing current. The numerical results for interaction between wave and current are shown to be in good agreement with experimental data. Then, this study focused on the dynamic motions of the water velocity, surface elevation and vorticity within combined wave-current field in demonstrating complex nonlinear physical phenomena due to interaction between wave and current. In addition, NWCT is applied to simulate a more complex wave-current-structure field for wave propagating over a submerged breakwater associated with current. Detailed discussion including characteristics of velocity and vorticity fields and the relation between free surface and vorticity are given.

Drought forecasting over South Korea based on the teleconnected global climate variables

  • Taesam Lee;Yejin Kong;Sejeong Lee;Taegyun Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.47-47
    • /
    • 2023
  • Drought occurs due to lack of water resources over an extended period and its intensity has been magnified globally by climate change. In recent years, drought over South Korea has also been intensed, and the prediction was inevitable for the water resource management and water industry. Therefore, drought forecasting over South Korea was performed in the current study with the following procedure. First, accumulated spring precipitation(ASP) driven by the 93 weather stations in South Korea was taken with their median. Then, correlation analysis was followed between ASP and Df4m, the differences of two pair of the global winter MSLP. The 37 Df4m variables with high correlations over 0.55 was chosen and sorted into three regions. The selected Df4m variables in the same region showed high similarity, leading the multicollinearity problem. To avoid this problem, a model that performs variable selection and model fitting at once, least absolute shrinkage and selection operator(LASSO) was applied. The LASSO model selected 5 variables which showed a good agreement of the predicted with the observed value, R2=0.72. Other models such as multiple linear regression model and ElasticNet were also performed, but did not present a performance as good as LASSO. Therefore, LASSO model can be an appropriate model to forecast spring drought over South Korea and can be used to mange water resources efficiently.

  • PDF

Enhancement of Power System Transient Stability and Power Quality Using a Novel Solid-state Fault Current Limiter

  • Fereidouni, A.R.;Vahidi, B.;Mehr, T. Hoseini;Doiran, M. Garmroodi
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.474-483
    • /
    • 2011
  • Solid-state fault current limiters (SSFCL) in power systems are alternative devices to limit prospective short circuit currents from reaching lower levels. Fault current limiters (FCL) can be classified into two categories: R-type (resistive) FCLs and L-type (inductive) FCLs. L-type FCL uses an inductor to limit fault level and is more efficient in suppressing voltage drop during a fault. In contrast, R-type FCL is constructed with a resistance and is more effective in consuming the acceleration energy of generators during a fault. Both functions enhance the transient stability of the power system. In the present paper, a novel SSFCL is proposed to enhance power system transient stability and power quality. The proposed SSFCL uses both functions of an L-type and R-type FCL. SSFCL consists of four diodes, one self-turn-off IGCT, a current-limiting by-pass inductor (L), and a variable resistance parallel with an inductor for improvement of power system stability and prevention of over-voltage across SSFCL. The main advantages of the proposed SSFCL are the simplicity of its structure and control, low steady-state impedance, fast response, and the existence of R-type and Ltype impedances during the fault, all of which improve power system stability and power quality. Simulations are accomplished in PSCAD/EMTDC.

The Thermal Characteristics of Partially Disconnected Wire Happened in Plug (플러그 내부에서 발생된 소선 단선에 의한 발열특성)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Lee, Chun-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.104-110
    • /
    • 2011
  • There are over 30[%] of electric fires in Korea happened at wire or wiring devices. For its prevention many safety devices are set up electric equipments. These safety devices are not working in a rated current's condition of electric equipment. But when wire is partially disconnected, electric fire is able to be happened even though current is smaller than a rated current value. This paper studied thermal characteristics and fire ability when wire in plug is partially disconnected. The experiment is progressed a method that inner wire of plug is partially disconnected and after that current that is less than a rated current is flowed. As the result, heating occurred in near of partially disconnected wire makes that outer sheath is melted, plug cover is carbonized, and even sometimes wire is fused. And results of analysis of thermal image of partially disconnected wire happened in plug, it shows a difference to heating distribution and temperature appeared surface of plug depend on a progress of a partially disconnected wire.

Analysis of temperature effects on DC parameters of AlGaAs/GaAs HBT (AlGaAs/GaAs HBT의 DC 파라미터에 미치는 온도영향의 해석)

  • 김득영;박재홍;송정근
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.12
    • /
    • pp.39-46
    • /
    • 1996
  • In AlGaAs/GaAs HBT the temperature dependence of DC parameters was investigated over the temperature range between 95K and 580K. The temperature dependence of DC parameters depends on the relative contribution of each of the current components suc as emitter-injection-current, base-injection-current, bulk recombination current, interface recombination curretn, thermal generation ecurrent and avalanche current due to impact ionization within the collector space charge layer in a specific temperature. In this paper we investigated the temperature effects on DC parameters such as V$_{BE,ON}$ current gain, input and output characteristics, V$_{CE, OFF}$, R$_{E}$, R$_{C}$ and analyzed the origins, and extracted the qualitativ econditions for a stable HBTs against the temperature variation. Finally, in order to keep HBTs stable with respect to the variation of temperature, the valance-band-energy-discontinuity at emitter-base heterojunction should be large enough to enhance the effect of carrier suppression at a relatively high temperature. In addition the recombination centers, especially around collector junction, should be removed and the area of emitter and collector junction should be identical as well.

  • PDF

A Study on the Comparison and Analysis of Leakage Current according to Environmental Variation of EHV insulators(36,000LBS) by Pollution Level (송전용 자기애자(36,000LBS)의 오손 등급별 환경변화에 따른 누설전류 분석 및 비교 연구)

  • Choi I. H.;Choi J. H.;Jung Y. H.;Lee D. I.;Jung G. J.;Shin T. W.;Bang H. K.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.527-529
    • /
    • 2004
  • This paper researched leakage current characteristics of EHW insulators(36,000lbs) to artificially contaminated clay and kaolin through construction of long-periods testing facility. Insulators were contaminated and classified into the ESDD level(B, C and D) under IEC Pub. 60507 standards method. As a result of tests, leakage current of the heavily contaminated D level to clay was approximately 2,260 $[\muA]$, which is contaminated to kaolin was approximately 3,200 $[\muA]$, during initial rainfall. However after raining, leakage current of naturally washed contamination insulators was lower at approximately 300 $[\muA]$. As regular temperature $20^{\circ}C$, leakage current increased greatly in case humidity density was over $72\%$. But, leakage current was not influenced by temperature variation in case of regular $\%$ humidity.

  • PDF

Maximum Torque Control of IPMSM Drive using Optimal Current (최적전류를 이용한 IPMSM 드라이브의 최대토크 제)

  • Baek, Jeong-Woo;Ko, Jae-Sub;Choi, Jung-Sik;Kang, Sung-Jun;Jang, Mi-Geum;Mun, Ju-Hui;Chung, Dong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.57-58
    • /
    • 2010
  • This paper proposes maximum torque control of IPMSM drive using optimal current. This control method is applicable over the entire speed range which considered the limits of the inverter's current and voltage rated value. For each control mode, a condition that determines the optimal d-axis current $i_d$ for maximum torque operation is derived. This paper considers the design and implementation of novel technique of high performance speed control for IPMSM using multi-MFC and ANN controller. Also, this paper proposes maximum control of IPMSM drive using approximation method. This method is decreased the burden of digital signal process(DSP) in calculation of optimal current. This paper proposes the analysis results to verify the effectiveness of the MFC and ANN controller. Also it verifies the validity of maximum torque control of IPMSM drive with optimal current.

  • PDF

Evolution of the Magnetosphere in Response to a Sudden Ring Current Injection

  • Choe, G.S.;Park, Geun-Seok;Lee, Jung-Gi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.100.2-100.2
    • /
    • 2011
  • The dynamical evolution of the Earth's magnetosphere loaded with a transiently enhanced ring current is studied by numerical magnetohydrodynamic (MHD) simulation. Two cases with different values of the primitive ring current are considered. In one case, the initial ring current is strong enough to create a magnetic island in the magnetosphere. The magnetic island readily reconnects with the earth-connected ambient field and is destroyed as the system approaches a steady equilibrium. In the other case, the initial ring current is not so strong, and the initial magnetic field configuration bears no magnetic island, but a wake of bent field lines, which is smoothed out through the relaxing evolution of the magnetosphere. The relaxation time of the magnetosphere is found to be about five to six minutes, over which the ring current is reduced to about a quarter of its initial value. Before reaching a steady state, the magnetosphere is found to undergo an overshooting expansion and a subsequent contraction. Fast and slow magnetosonic waves are identified to play an important role in the relaxation toward equilibrium.

  • PDF

Applicability of Boussinesq Models for Wave Deformation and Wave-Induced Current (파랑변형 및 해빈류에 대한 Boussinesq 모형의 적용성 검토)

  • Cho, Young-Jun;Park, Il-Heum
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.2
    • /
    • pp.185-193
    • /
    • 2010
  • In the present study, wave deformation and wave-induced current were calculated under the regular wave conditions using the Boussinesq model. The model results of the wave deformation showed good agreements with the preceeding laboratory experiments of others. The wave-induced current of the fully developed sea state was calculated. For field application of model, the preceeding field data by others in the real scale of the water area were compared, the numerical result of wave deformation showed a relatively good agreement with the field data. Although the numerical result of wave-induced current was underestimated over the longshore bar developed area, the Boussinesq model is generally suitable to predict the wave-induced current.

A Study on the Influence of Al Alloy Sacrificial Anode Efficiency due to Marine Environmental Variation (해양환경 변화가 알루미늄합금 희생양극의 효율에 미치는 영향에 관한 연구)

  • 김도형
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.2
    • /
    • pp.106-111
    • /
    • 2000
  • Recently it was reported that the life of Al Sacrifical anode is being used in port piers has been significantly shortened compared with the original design life (e.g. average life shortened from 20 years to 13-15 year) Those factors involving these problems mentioned above were seemed to be a quality of anode material and diverse environmental factors such as pH flow rate temperature Dissolved oxygen Chemical oxygen demand and resistivity etcm In this study flow rate and contamination degree(pH) of sea water affecting to sacrificial anode life hve been investigated in terms of electrochemical characteristics of Al alloy sacrificial anode It was known that the lifetime of Al alloy anode was shortened not only by increasing of self-corrosion quantity by varying flow rate of sea water but also by increasing corrosion current density due to the potential difference increment between Al anode and steel structure cathode by varying contamination degree of sea water. Especially when anode current density is from 1mA/cm2 to 3mA/cm2 and flow rate of sea water is under 2m/s anode current efficiency is 90% above However flow rate is over 2m/s anode current efficiency fell down sharply due to erosion corrosion as well as galvanic corrosion.

  • PDF