• 제목/요약/키워드: over-current

검색결과 5,914건 처리시간 0.04초

Structure and Vorticity of the Current Observed Across the Western Channel of the Korea Strait in September of 1987-1989

  • Byun, Sang-Kyung;Kaneko, Arata
    • Ocean and Polar Research
    • /
    • 제21권2호
    • /
    • pp.99-108
    • /
    • 1999
  • With sectional data obtained in September of 1987, 1988 and 1989 by quadrireciprocal ADCP measurement and CTD cast, the current structure, volume transport and vorticity in the Western Channel of the Korea Strait were studied. The characteristics of Tsushima Current water persisted throughout the summer especially in the homogeneous water of temperature $14-16^{\circ}C$ located at the depth of 50-100m below seasonal termocline. Thickness and velocity of the homogeneous layer are about 10-170m and 20-60cm/s. and the relative vorticity for this layer is shown to be nearly constant and it is smaller than the planetary vorticity. Potential vorticity of $2.70-7.10{\times}10^{-6}m^{-1}s^{-1}$ is found to be dependent mainly on planetary rather than on the relative vorticities. The Tsushima Current water represented by the homogeneous layer R14-16^{\circ}C$ may keep the potential vorticity at the area of strong current in the Strait. The ADCP current structure is similar to geostrophic current and the core of the current with the speed of 30-50cm/s is situated in the middle layer over the deep trough. With large tidal fluctuation the volume transport has mean value of 1.17sv which was about 40% larger than that of geostrophic calculation.

  • PDF

고조파 전류를 이용한 영구자석형 동기 전동기의 토크 리플 저감 (Torque Ripple Reduction for Permanent Magnet Synchronous Motor using Harmonic Current Injection)

  • 권순오;이정종;이근호;홍정표
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1930-1935
    • /
    • 2009
  • This paper deals with the torque ripple reduction of permanent magnet synchronous motor using harmonic current injection. Torque ripple of electric motor reduces system stability and performances, therefore efforts to reduce torque ripple are exerted in the design process. Torque ripple can be reduced by appropriate pole/slot combination, skew of rotor or stator, design of magnetic circuit, etc. In addition, torque ripple can be also reduced by input voltage and current, and many researches have been conducted to reduce torque ripple for six-step drive. Torque ripple reduction for current vector controlled permanent magnet synchronous motor also have been conducted and verified by investigating back emf wave form. Torque ripple reduction in this paper started from getting torque profile according to input current and electrical angle calculated by FEA, then instantaneous currents at each electrical angles for constant torque are calculated and applied to experiments. Therefore, 0% of torque ripple can be obtained theoretically with harmonic current injection. In order to maximize the effect of torque ripple reduction, a BLDC motor having high harmonic component of back emf is chosen. With sinusoidal current drive, over 100% of torque ripple is obtained initially, then 0.5 % of torque ripple is obtained by FEA using harmonic current injection. The effect is verified by experiment and the presented method can be effectively applicable to Electric Power Steering(EPS).

철심 변류기의 2차 전류 보상 알고리즘의 실시간 구현 및 오차 분석 (Hardware implementation and error analysis of an algorithm for compensating the secondary current of iron-cored current transformers)

  • 강용철;김성수;박종근;강상희;김광호
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.490-500
    • /
    • 1996
  • The conventional method to deal with current transformer (CT) Saturation is over dimensioning of the core so that CTs can carry up to 20 times the rated current without exceeding 10% ratio correction. However, this not only reduces the sensitivity of relays as some errors may still be present in the secondary current when a severe fault occurs, but also increases the CT size. This paper presents an algorithm for compensating the distorted secondary current of iron-cored CTs under CT saturation using the magnetization (flux-current : .lambda.-i) curve and its performance is examined for fault currents encountered on a typical 345[kV] Korean transmission system, under a variety of different system and fault conditions. In addition, the results of hardware implementation of the algorithm using a TMS320C10 digital signal processor are also presented. The proposed algorithm can improve the sensitivity of relays to low level internal faults, maximize the stability of relays for external faults, and reduce the required CT core cross-section significantly. (author). refs., figs.

  • PDF

3권선 변압기 순환전류 추정 알고리즘 (Estimation of a circulating current of a three-phase Y-Y-$\Delta$ transformer)

  • 강용철;이미선;이병은;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.559-560
    • /
    • 2007
  • In the case of the transformers including the delta winding such as a three-phase Y-Y-$\Delta$ transformer, a delta winding current flows in the delta windings. The delta winding current of a three-phase Y-Y-$\Delta$ transformer is decomposed into a non-circulating current and a circulating current. The former can be estimated directly from the line currents, but the latter can not. This paper proposes an estimation method for a circulating current of a Y-Y-$\Delta$ Transformer. A first order differential equation for the circulating current is derived by applying the Kirchhoff's voltage law on the loop of the delta side. The circulating current can be estimated by solving the differential equation. Various test results indicate the algorithm can estimate the circulating current accurately even under over-excitation and magnetic inrush.

  • PDF

PBDG의 자격 전달에 관한 연구 (A Study on the Stimulation Transmit of PBDG)

  • 김동관;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1980-1982
    • /
    • 1999
  • Conductive Langmuir-Blodgett(LB) films have recently attracted much interest from the viewpoint of ultrathin film conductors at the molecular level. The result shows that the Maxwell-displacement-current (MDC) measuring technique is useful in the detection of phase-transitions over the entire range of molecule areas. In this parer, electrical properties of PBDG Langmuir(L) films were investigated using a displacement current measuring technique with pressure stimulation. Displacement current was generated When the Spread volume $150{\mu}{\ell}$ and compression velocity was about 30, 40, 50 mm/min. In the result, it is known that current is generated of higher current peek as compression velocity become faster.

  • PDF

Excimer laser로 재결정화한 LDD구조의 poly-Si TFT 제작 (Fabrication of the LDD Structure poly-Si TFT with Excimer Laser Recrystallization Process)

  • 정준호;박용해
    • 전자공학회논문지A
    • /
    • 제32A권2호
    • /
    • pp.324-331
    • /
    • 1995
  • The leakage current characteristics of the low temperature processed LDD structure poly-Si TFT is analyzed. The excimer laser technology was applied to the recrystallization process of poly-Si film and the maximum processing temperature was retained under 600.deg.C. From the fabricated LDD space 0.3.mu.m to 3$\mu$m, the best on/off current ration could be obtained with the 1.3$\mu$m LDD space. And the threshold voltage did not increase more than 4V over 0.8$\mu$m LDD space. The characteristics of leakage current was compared to non-LDD structure TFT to analyze the mechanism of leakage current. Consequently, it could be concluded that the leakage current is strongly affected by the trap states as well as high electric field between gate and drain.

  • PDF

전류모드제어를 적용한 직류전원장치의 해석 및 보상에 관한 연구 (The Analysis and Compensation of DC to DC Converter with Current Mode Controller)

  • 김철진;김영태;송요창
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권5호
    • /
    • pp.230-237
    • /
    • 2003
  • Current mode control has been used for DC to DC converters for over twenty years. There are many different control schemes which use the inductor current signal in one way or another to control the DC to DC converter. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the guarantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test result. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency fc is early 1/5 of switching frequency, fs, from the experimental result with frequency response analyzer.

지중송전계통에서 시스순환전류 해석 및 저감방안 (Analysis and Reduction Methods of Sheath Circulating Current in Underground Transmission Systems)

  • 정채균;이종범;강지원;장태인
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권11호
    • /
    • pp.537-545
    • /
    • 2001
  • This paper describes the analysis of sheath circulating current and various methods to reduce the large circulating current in case of operating cable system using EMTP/ATPDraw. And also, possible methods are proposed through a detailed analysis regarding cable systems by considering various electrical and environmental factors. It is evaluated that the proposed reduction methods can be effectively applied to reduce the large sheath circulating over current with the minimized electrical problems.

  • PDF

교류가 유도되는 매설배관에서의 교류 부식속도 측정에 관한 연구 (Corrosion Rate of Buried Pipeline by Induced Alternating Current)

  • 송홍석;김영근;이성민;고영태;박용수
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2001년도 추계학술발표회 논문집
    • /
    • pp.45-57
    • /
    • 2001
  • An alternating current (AC) corrosion using coupon has been studied. Coupons were applied in terms of AC voltage from high value to low value through the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion(: below -850mv vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relationship could be obtained statistically, in which AC corrosion rate increased linearly with effective AC current density and its slope was 0.619.

  • PDF

PSCAD/EMTDC를 이용한 불평형 부하에서의 초전도 케이블의 운전특성 해석 (A Operated Characteristic Analysis of HTS Cable in Unbalanced Load Using PSCAD/EMTDC)

  • 이현철;황시돌;이근준
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1713-1719
    • /
    • 2008
  • A high temperature superconducting power cable (HTS power cable) was applied large current capacity by no resistance in normal state. Fault state was risen out of over-current but, it was limited to resistance. This study was modeling equivalence, and unbalanced state analyzed operating characteristic of HTS power cable. The equivalence model was composed superconductor, shield, and former part. This model simulation was appeared conductor and shield current in normal state, but unbalanced state was appeared former current as rise current by resistance. So it need to sufficiently influenced the quench characteristic when the former design.