• 제목/요약/키워드: outside experiment

검색결과 351건 처리시간 0.029초

MULTI-SCALE THERMAL-HYDRAULIC ANALYSIS OF PWRS USING THE CUPID CODE

  • Yoon, Han Young;Cho, Hyoung Kyu;Lee, Jae Ryong;Park, Ik Kyu;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • 제44권8호
    • /
    • pp.831-846
    • /
    • 2012
  • KAERI has developed a two-phase CFD code, CUPID, for a refined calculation of transient two-phase flows related to nuclear reactor thermal hydraulics, and its numerical models have been verified in previous studies. In this paper, the CUPID code is validated against experiments on the downcomer boiling and moderator flow in a Calandria vessel. Physical models relevant to the validation are discussed. Thereafter, multi-scale thermal hydraulic analyses using the CUPID code are introduced. At first, a component-scale calculation for the passive condensate cooling tank (PCCT) of the PASCAL experiment is linked to the CFD-scale calculation for local boiling heat transfer outside the heat exchanger tube. Next, the Rossendorf coolant mixing (ROCOM) test is analyzed by using the CUPID code, which is implicitly coupled with a system-scale code, MARS.

Analysis of Thermal Distribution for LCD-TV Using Numerical Simulation and Experiment (수치해석 및 실험에 의한 LCD-TV의 열분포 분석)

  • Kim, Yoon-Seok;Lee, Jeoung-Gwen;Chung, Du-Hwan;Ko, Han-Seo
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.302-307
    • /
    • 2003
  • Demand of the LCD-TV is remarkably increasing with development of the LCD technology in these days. Thus, this research has analyzed thermal problems such as heat transfer characteristics inside and outside the LCD-TV using numerical simulation and experiments. The simulated results have been compared with the experimental results using an infrared (IR) camera and T-type thermocouples. The optimal design of structure has been proposed to improve the thermal efficiency of radiation from the comparison.

  • PDF

Performance Analysis of Heat Pump System for Greenhouse Cooling (온실 냉방을 위한 히트펌프의 성능 분석)

  • 윤용철;서원명;이석건
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • 제43권6호
    • /
    • pp.120-126
    • /
    • 2001
  • This experiment was carried out to analyse on the cooling and dehumidifying effects of greenhouse by air-to-water heat pump system employing the air as cooling source. following results were obtained ; 1. The coefficients of performance (COP) of heat pump itself and total heat pump system were approximately 2.71~2.88 and 1.99~2.22, respectively. 2. The night-time cooling load of experimental greenhouse was 64.9 MJ/h, and the heat absorbed (cooling load) from heat pump system was 816.3~1,004.6 MJ/day. 3. The dehumidified moisture amount from experimental greenhouse was 7.0~15.0 kg/h. 4. The night time temperature of experimental greenhouse cooled by heat pump system could be maintained 4~6$^{\circ}C$ lower than that of control greenhouse which was almost equal to outside air temperature.

  • PDF

Analysis of Environmental Factors in Pleurotus eryngii Cultivation House(III) -Based on Panel Type Structure- (새송이버섯 재배사의 환경인자 계측(III) -영구재배사를 중심으로-)

  • Suh, Won-Myung;Yoon, Yong-Cheol
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.187-192
    • /
    • 2005
  • Pleurotus eryngii(King oyster) is one of the most promising mushrooms being produced on the domestic farms. The quality as well as quantity of Eryngii is sensitively affected by micro climate factors. To safely produce high-quality Eryngii all the year round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. This study was carried out at the commercial mushroom cultivation houses to find out reasonable range of each environmental factor and yield together with economic and safe structures influencing on the optimal productivity of Eryngii. This experiment was conducted from Nov. 10, 2004 to Aug. 27, 2005 in Eryngii. cultivation houses. The environmental factors measured for this study were inside/outside temperature, relative humidity and $CO_2$ concentration in Pleurotus eryngii medium. In addition, the yield and quality of mushroom were made investigation. But the optimal productivity will be evaluated by considering the quality and quantity of mushroom production, energy requirements, facility construction and management cost, etc.

  • PDF

A measurement of piston surface temperature by using instantaneous temperature measuring probe (순간온도 계측 프로브를 사용한 피스턴 표면 온도측정)

  • 이성열;이영조
    • Journal of the korean Society of Automotive Engineers
    • /
    • 제12권6호
    • /
    • pp.60-66
    • /
    • 1990
  • In order to measure the piston surface temperature and heat flux, autors have developed the measuring system with an instantaneous temperature probe. Such the instantaneous temperature probes were embodied into the top of piston for measurement and L-link system, designed to fit the test engine, extracts the thermocouple wires from the piston outside of engine employing a mechanical linkage. Then the instantaneous surface temperature was measured to calculate the heat flux flowing into the top surface of piston in a spark ignition engine. As a result, the following phenomena have been obtained through the study. 1) It is found that the time response and durability of temperature probe with a thin film thickness 10um and mechanical linkage with thermocouple wire extraction is sufficient at this experiment. 2) For the quantitative effect of variation in engine speed, the temperature swing and heat flux on the top of piston increase with increasing the engine speed. 3) It is proved that the temperature swing and heat flux decrease with distance from spark plug.

  • PDF

Detection of partial Discharge in the Metal Clad Switchgear Using the Electromagnetic Technique (전자파 측정기법을 이용한 폐쇄 배전반내 부분방전 검출)

  • Seo, In-Chul;Kim, Jae-Chul;Kim, Young-No;Jeon, Young-Jae
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.403-405
    • /
    • 2001
  • This paper presents the detection method of partial discharge in metal clad switchgear(MCS) using electromagnetic technique. Two antennas are located in the inside and outside of the MCS, and electromagnetic waves detected by these antennas are analyzed and compared by FFT method in order to identify an insulation abnormality. As a result of the experiment by the proposed method, we show the detection possibility for partial discharge in the MCS. The proposed method is expected to apply to insulation condition observation and an accident prevention in the MCS effectively.

  • PDF

Hydraulic Model Experiment on the Circulation in Sagami Bay, Japan (III) -The Time-Varying States of the Flow Pattern and Water Exchange in Barotropic Rotating Model-

  • Choo Hyo-Sang;Sugimoto Takasige
    • Fisheries and Aquatic Sciences
    • /
    • 제1권2호
    • /
    • pp.260-268
    • /
    • 1998
  • A flow pattern and water exchange in Sagami Bay is examined using a barotropic hydraulic model. In the model experiments, the volume transports of the Kuroshio Through Flow were changed with time. The results of the model experiments show that when the volume transport is increased with time, water mass and vorticity are transferred to the inner part of the bay by wakes from the western part of the bay. In the case of decrease, as the wakes are ceased, the inner cyclonic circulation water is discharged to the outside of the bay by its southward extension through the Oshima eastern channel. It is found that the water exchange by the short-term variation of volume transport in time is about 20% of all the bay water.

  • PDF

Application Study on the Outdoor Air Temperature Prediction Control for Continuous Floor Heating System (연속바닥난방시스템에 대한 외기예측제어적용 연구)

  • 태춘섭;조성환;이충구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제13권9호
    • /
    • pp.836-844
    • /
    • 2001
  • For the radiant floor heating system, the possibility of suboptimal prediction control was investigated by computer simulation and experiment. For this study, TRANSYS program was used and an experimental facility consisting of two rooms (3$\times$4.4$\times$2.8m) was built. The facility enabled simultaneous comparison of two different control strategies which implemented in a separate room. Results showed that outdoor air temperature prediction control was superior to the conventional outdoor air temperature compensation control for radiant floor heating system. However, more research for fine prediction of outside air temperature was required in the future.

  • PDF

Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct (열회수장치에 의한 열교환 성능 분석(농업시설))

  • 서원명;강종국;윤용철;김정섭
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.333-339
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas funnel connected to combustion chamber of greenhouse heating system. The experiment heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas funnel, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amount by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air pipes and exhaust air passages crossing the pipes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through funnels.

  • PDF

Experimental Investigation of Wedge Slamming Impact (쐐기 슬래밍에 관한 실험적 연구)

  • Di, Ren;Ahn, Gang-Su;Kwon, Sun-Hong
    • Journal of Ocean Engineering and Technology
    • /
    • 제29권2호
    • /
    • pp.163-168
    • /
    • 2015
  • This paper presents the results of experimental work on the wedge slamming impact problem. An experiment was done with a wedge model. The deadrise angle of the wedge was $4^{\circ}$. The model was made in two parts: the outside part was made of a 5-mm-thick steel plate that could be assumed to be a rigid body, and the inside part was made of a thin SUS plate that could be assumed to be an elastic body. Thin SUS plate thicknesses of 2 mm and 3 mm were used to determine the effect of plate rigidity. The drop height was varied from 0.25 m to 1 m to determine the effect of a large deformation.