• Title/Summary/Keyword: outflow load

Search Result 53, Processing Time 0.036 seconds

A Study on the Application of Micro Hydro Power Generator at the Water Treatment Plant (정수장 마이크로 소수력 발전기 적용에 대한 연구)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Kim, Il-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.67-72
    • /
    • 2014
  • Inflow or outflow from the water treatment plant and the sewage water has potential energy. If this potential energy can be converted into electrical energy by water turbine generator, it can help to save energy because of the high capacity utilization. So recently, micro hydro power plant is reviewed in the water treatment facility. If generation capacity is low, induction generator is primarily used. If output capacity is low, generated power is supplied to the inside load. Induction generator can cause voltage drop by the inrush current at a start-up and requires reactive power for magnetization. In this study, we analyzed the flow of power and voltage variation against inrush current that occurs when the induction generator starts under the terms that loads of linear and non-linear of the water purification plant are used. Analysis results are that the voltage drop is within an allowable range and the power factor is slightly reduced by the need of reactive power.

Characteristics of Non-Point Pollutant Runoff in Highland Field Fields through Long-term Monitoring (장기 모니터링을 통한 고랭지 밭 지역의 비점오염물질 유출특성)

  • Lee, Su In;Shin, Jae Young;Shin, Min Hwan;Ju, So-Hui;Seo, Ji Yeon;Park, Woon Ji;Lee, Jae Young;Choi, Joong Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.4
    • /
    • pp.85-96
    • /
    • 2017
  • In this research, I performed rainfall monitoring by selecting the spot which can represent high altitude cool farm region in recent 3 years, and tried to understand the characteristic of outflow of non-point pollutants coming from high altitude cool farm region. As a result, it was shown that reducing rainfall runoff in highland farm area can reduce non-point pollution load and should consider priority to reduce runoff through management resources when selecting abatement method. Additionally, it is judged that reduction method related to base run-off should be selected by performing research on material motion of TN.

Evaluation of Application to Pre-Developed Delivery Load Equation at Upper Watershed of the Daechung Reservoir (대청호 상류유역의 기 개발된 유달부하량 산정식의 적용성 평가)

  • Lee, Jun-Bae;Kim, Kap-Soon;Lee, Kyu-Seung;Yoon, Young-Sam;Lim, Byung-Jin;Jung, Jae-Woon
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.1
    • /
    • pp.16-23
    • /
    • 2012
  • BACKGROUND: To improve the Daechung reservoir water quality, a quantitative estimation of the delivery load from upper watershed need to be conducted prior to others. To do so, an intensive monitoring is necessary because of the complexity and uncertainty of the delivery load from uppper watershed. However, intensive monitoring need to invest much time, cost, and effort. So, many researcher have developed an equation to estimate the delivery loads. But, relatively little research has been conducted on the applicability of pre-developed equation using other sites. Therefore, the objective of this study was to evaluate application of the equation for BOD, T-N and T-P delivery load. METHODS AND RESULTS: To verify the applicability of the equation, the following equation was used; Delivery loads(kg/day)=generated pollutant loads${\times}(1-{\alpha}){\times}$(daily outflow/${\beta})^{\gamma}$. The equations could be calculated the daily delivery loads of streams without any data of water quality, only with the data of daily runoff of study sites. The equations were applied to Youngdogcheon, Chogangcheon, Bocheongcheon, Sookcheon to examine its applicability using monitoring data. The results showed that the estimated delivery loads were in a good agreement with the observed data and indicated reasonable applicability of the equations. CONCLUSION(s): Overall, the equations were satisfactory in estimation of delivery loads at upper watershed of the Daechung reservoir. Therefore, the equations could be contributed to better water quality management in the Daechung reservoir.

Development of a constant pressure feed system using a constant pressure proportional control mode (정압비례제어방식을 적용한 정압급수장치의 개발)

  • 김주명;김광열;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.1026-1031
    • /
    • 2003
  • Automatic feed pumps are operated and stopped by a pressure switch. Thus, because of repeated operations and stops of the pumps according to fluctuations of water volume, operation with constant rate and pressure is impossible. Moreover, because of repeated running of the pump, keeping up of constant pressure is impossible and damage and energy loss are weak points of the pimps. To make up for defects of an automatic feed pump, this paper designed and made a static pressure feed system which was composed of a feed water control valve, a flow sensor and a control system. The valve device plays an important part in reducing load of pumps by constant water supply regardless of outflow of water. Outflow of water is determined by infrared diode of the flow sensor. The control system is made of a 8 bit micro-processor and the pump was controled by a specific control algorithm. With the constant pressure feed system, discharge pressure was kept at fixed pressure, accurate operations and stops were smoothly accomplished and the pump was operated with constant pressure. Thus, the constant pressure feed system can be considered as an advanced system which made up for the weak points in the current automatic feed systems.

Characteristics of Nitrogen and Phosphorous Loadings from a Paddy Field Area (광역논에서의 질소와 인의 오염부하량 특성)

  • 김진수;오승영;김규성
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.527-532
    • /
    • 1998
  • The inflow and outflow loads of T-N and T-P from a paddy field area during the irrigation period were investigated. For the concentration of T-N and T-P, surface water in paddies showed highest among irrigation water, drainage water and percolation water. For T-N, the average concentration of drainage water is higher than that of irrigation water before middle of June but is lower since. It is shown that the L(load)-Q (discharge) equation of T-N has high correlation for irrigation water, but the L-Q equation of T-P has high correlation for drainage water.

  • PDF

Failure Risk Evaluation to Flood for Irrigation Reservoirs (농업용 저수지의 홍수 취약성 지수 개발)

  • Jang, Min-Won;Choi, Jin-Yong;Lee, Jun-Goo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.135-138
    • /
    • 2005
  • This study began to establish a risk evaluation method for irrigation reservoirs under the overtopping failure mode. To define the risk, reliability analysis was performed using time series of reservoir flood inflow and spillway outflow. The former was defined as a load and the latter was the resistance component. The method results in failure probability, which is calculated by convolution multiplication between probability distribution functions of both components. The proposed method was applied to 3 reservoir sites and each failure probability was determined as 0.0012, 0.00001, and 0.000001 respectively.

  • PDF

Combustion Chamber Shape Effects on Flame Temperatgure and KL Value in a Diesel Engine (디젤엔진에서 연소실 형상이 화영온도 및 KL치에 미치는 영향)

  • 이선봉;이태원;하종률
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.99-106
    • /
    • 1999
  • The present study deals with the effect of combustion chamber shape on in-cylinder soot oxidation characteristics of a D.I . diesel engine. The analysed combustion chambers were a toroidal and a reentrant with a projection(Complex). The two-color method was used to measure in-cylinder flame temperature and KL value which is approximately proportional to the soot amount along the optical path. In addition, heat release rate was calculated from the in-cylinder pressure data. From these investigations , the soot oxidation of the reentrant and the complex which were strengthen squish flows went worse in late combustion period under heavy-load operation compared to that of the toroidal at retarded fuel injection timing . It might be the cause of the flame holding that squish lip depress the outflow of flame from the bowl to the entire combustion space.

  • PDF

A Case Study on RFID-PPS(Radio Frequency IDentification-Pallet Pool System) (RFID-PPS (Radio Frequency IDentification-Pallet Pool System) 사례연구)

  • 안종윤;양광모;진향찬;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.303-307
    • /
    • 2004
  • Is not used by consistency transport at transport of freight nothing but is using Pallet only by pedestal when work palletized unit load or materials handling when keep simplicity receptacle which fill raw material or product in factory in our country. Therefore, pallet that is most important function of Pallet is not empled circulation to end consumer from manufacturing plant which is circulation process whole path being done and factory. It is real condition stopping only in extremely determinate part process use of warehouse back. Additionally, it is possible to figure out the flow of all the materials loaded on the RFID pallet; product, material, raw material immediately, so that epoch-making management is possible and it contributes to the reduction of logistics cost because there are little loss or outflow of pallet. The materials flow is getting speedy and inventory is decreasing in the logistics process, and also bad inventory and loss problems are prevented. As a result, not only logistics cost of company but also national logistics cost is decreased. Thus it contributes to the strength of national competitiveness.

  • PDF

Estimation of Flow Loads Characteristics each Sub-watershed for TMDL (TMDL 적용을 위한 소유역별 유출부하 특성 분석)

  • Kim, Joo-Hun;Kim, Kyung-Tak;Lee, Jin-Won
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.443-453
    • /
    • 2011
  • This research aims at suggesting the mitigation measures of decreasing pollution by analyzing land cover characteristics according to subwatershed, and non-pollutant load characteristics occurring in each subwatershed. Mushim-cheon is selected as a research area, and HyGIS-SWAT is used as a water quality model. This research analyzed outflow load characteristics by classifying land cover, which has over 50% classified items, into a city area, a farmland area and a forest area. The result shows that the yearly occurrence load quantity represents a farmland area, a forest area and a city area in order. In subwatershed-2, occurrence load quantity is analyzed by setting up a buffer zone in the center of stream, and by changing a farmland area into a natural grass land. Therefore, a farmland area in a subwatershed changes 36.6% into 27.9% and 15.3% comparing to previous land cover change. In the analysis of sediment loads occurrence quantity and nutritive salt load occurrence quantity in subwatershed-2, sediment loads occurrence quantity decreases 52% to about 47%, and nutritive salt load decreases 49% and 34% in compare with previous change. Hereafter, this research will set up the mitigation measures scenario, and find out which is more effective for the mitigation measures.

A Study on the Inflowing Pollution Load and Material Budgets in Hampyeong Bay (함평만의 유입오염부하량 및 물질수지에 관한 연구)

  • Kim, Jong-Gu;Jang, Hyo-Sang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • In this paper, an analysis of the inflowing pollution load of the rivers in Hampyeong bay showed the average organic matter pollution loads of BOD, COD, and TOC to be 79.7 kg-BOD/day, 144.06 kg-COD/day, and 93.0 kg-TOC/day, respectively. The inflowing organic matter pollution load was the heaviest in Sonbul dike, followed by Jupo bridge and Yangman complex. With regard to season, the load characteristics were outstanding in July, the rainy period in the summer. The average inflowing pollution loads of nutrients were 20.9 kg-DIN/day, 17.1 kg-DIP/day, 148 kg-TN/day, and 37.4 kg-TP/day A comparison of the inflowing nutrients loads for each river showed the load to be the heaviest in Yangman complex, followed by Baegok bridge and Jupo bridge. In the experiment on the material budgets of Hampyeong bridge conducted using a box model, the detention time of fresh water was found to be 52.4 days, with the bay displaying the characteristics of a so dissolved inorganic nitrogen (DIN) in the nutrients material budgets, ${\Delta}DIN$ values were found to be negative, indicating the tendency of consumption and open sea leak by photosynthesis to be higher than the nitrogen that flowed in. As for dissolved inorganic phosphorus (DIP), ${\Delta}DIP$ showed positive values, indicating a tendency for accumulation as the supply through organic matter decomposition, elution load of sediments, and inflowing load of the river turned out to be higher than the consumption by phytoplankton and outflow to open sea.