ANALYSIS OF THE INFLUENCE OF WEATHER ON CONSTRUCTION PRODUCTIVITY RATE FOR SUPER-HIGHRISE BUILDING CONSTRUCTION FRAMEWORK

  • Jae-won Shin;Han-kook Ryu;Moon-seo Park;Hyun-soo Lee
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.1124-1128
    • /
    • 2005
  • The duration of a construction project is not only a key element for taking a new order, but also a strict yardstick to determine certain project successful or not. However, since construction project is basically outdoor job and most of the activities are proceeded out-air, no matter how the schedule plan has been established accurately, actual project proceeds due to the weather condition, beyond anyone's control. In this paper, the functional relationship between work productivity rate and weather elements is suggested by regression analysis. Difference of the relationship and influence of weather due to the seasonal group are also revealed. With these results, by simulating actual weather data and generating weather forecast through historical data, more accurate schedule would be obtained.

  • PDF

Analysis of the Applicability of Aruco Marker-Based Worker Localization in Construction Sites (Aruco 마커 기반 건설 현장 작업자 위치 파악 적용성 분석)

  • Choi, Tae-Hung;Kim, Do-Keun;Jang, Se-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.205-206
    • /
    • 2023
  • This paper presents a new method for indoor localization track workers in construction sites. While GPS and NTRIP are effective for outdoor positioning, they are less accurate when used indoors. To address this issue, the proposed method utilizes Aruco markers to measure the distance between workers and the markers. By collecting data values, the location of each worker can be determined in real-time with high accuracy. This approach has the potential to enhance work efficiency and safety at construction sites, as it provides more precise indoor positioning compared to conventional methods, leading to improved work efficiency.

  • PDF

Evaluation of Airflow Control Capability of Natural Ventilators with Various Dampers (자연환기 벤틸레이터의 댐퍼 형태별 환기량 조절능력 평가)

  • Kim, Tae-Hyeong;Ha, Hyun-Chul;Park, Seung-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.364-374
    • /
    • 2006
  • Natural ventilation technique could be the substitute for or the complement to the local exhaust ventilation system in the sense of protecting work environment. Moreover, it has many strong points ; almost no mechanical parts, no energy use and no noise. If applied appropriately, it could have the very high ventilation rate and save a lot of energy expense. But, it depends on the outdoor environment, especially temperature and wind speed/direction. Predicting the capacity of natural ventilation is not an easy job because it comes from both buoyancy and wind effect. Another problem is too much flow through the ventilator especially in winter time due to too much difference between indoor and outdoor temperature. Thus some ventilators in industries are sealed by door or plastic sheet, resulting in bad work environment. Various types of dampers are used to control the flow rate through ventilators. The capabilities of flow control by damper has not been estimated. In addition, it was not tested whether the damper could obstruct the flow through ventilator when fully opened. To answer these questions, 4 types of dampers were tested by using computational fluid dynamics. 10 different configurations includes no damper, full open and half open. Flow rates were estimated and airflow fields were analysed to clarify the before-mentioned questions. The dual type damper was the best choice for controling the capability of ventilator. In addition, the upward grill type damper was the best for not obstructing the air flow when fully opened.

Development of Outdoor Geological Field Course for Elementary School Using Local Geology - Centers on the Odongdo- (지역 지질을 활용한 초등학교 야외지질학습장의 개발 - 오동도를 중심으로 -)

  • Kim, Hai-Gyoung
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.8 no.2
    • /
    • pp.128-138
    • /
    • 2015
  • The purpose of this study is to examine potential as a geological field course of Odongdo located to the east of Yeosu city, Korea. The total area and the height from the sea level of Odongdo is about 0.13km2 and 42m, respectively. Odongdo area belongs to the Hallyeohaesang National Marine Park, and is famous for rock scenery in the rocky coast and living of rare plants. For this study, diversity of geomorphology and geology was investigated at the sites called as dragon cave, windy area, seal rocks, sunrise viewing platform, second seashore rocks and first seashore rocks along the coast of Odongdo. The results of this study are as follows: A lot of geomorphological and geological resources like sea cliff, sea cave, strata, various sedimentary rocks(conglomerate, sandstone, mudstone), andesite, fault and examples of rock weathering were found in the rocky coast of the study area. These field resources are pertinent to the field work materials for the teaching and learning of geology units in elementary school science. Odongdo is to be recommended as a site of outdoor geological field course for the elementary school students inhabited in Yeosu city and neighborhood area because each site of the rocky coast in this study area has various field work materials and the wide space for observe activities, and is equipped with the facilities as a trail for rock observation.

Protective Measures From Solar Ultraviolet Radiation for Beach Lifeguards in Tuscany (Italy): Shade and Clothing Strategies

  • Daniele Grifoni;Giulio Betti;Andrea Bogi;Lucia Bramanti;Alessandra Chiarugi;Bernardo Gozzini;Marco Morabito;Francesco Picciolo;Francesco Sabatini;Lucia Miligi
    • Safety and Health at Work
    • /
    • v.13 no.4
    • /
    • pp.421-428
    • /
    • 2022
  • Background: The exposure to solar ultraviolet radiation is a significant risk factor generally underestimated by outdoor workers and employers. Several studies have pointed out that occupational solar exposure increased eye and skin diseases with a considerable impact on the lives and productivity of affected workers. The main purpose of this study was to evaluate the effectiveness against ultraviolet radiation of some measures recently undertaken for the protection of lifeguards in a coastal area of Tuscany. Methods: Different shading structures (gazebos and beach umbrella) were tested during a sunny summer's day on a sandy beach by means of two radiometers; the UV protection offered by some T-shirts used by lifeguards was also tested in the laboratory with a spectrophotometer. Results: The analysed shading structures strongly reduced the ultraviolet radiation by up to 90%, however a not always negligible diffuse radiation is also present in the shade, requiring further protective measures (T-shirt, sunglasses, sunscreen, etc.); the tested T-shirts showed a very good-excellent protection according to the Australian/New Zealand standard. Conclusion: Results obtained in this study suggest how the adoption and dissemination of good practices, including those tested, could be particularly effective as a primary prevention for lifeguards who are subjected to very high levels of radiation for long periods.

Performance Analysis of Double-Glazed Flat Plate Solar Collector with Cu-based Solar Thermal Absorber Surfaces

  • Lee, Jeong-Heon;Jeong, Da-Sol;Nam, Yeong-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.157.1-157.1
    • /
    • 2016
  • In this work, we experimentally investigated the solar absorption performance of Cu-based scalable nanostructured surfaces and compared their performance with the conventional TiNOX. We fabricated Cu-based nanostructured surfaces with a controlled chemical oxidation process applicable to a large area or complex geometry. We optimized the process parameters including the chemical compounds, dipping time and process temperature. We conducted both lab-scale and outdoor experiments to characterize the conversion efficiency of each absorber surfaces with single and double glazing setup. Lab-scale experiment was conducted with $50mm{\times}50mm$ absorber sample with 1-sun condition (1kW/m2) using a solar simulator (PEC-L01) with measuring the temperature at the absorber plate, cover glass, air gap and ambient. From the lab-scale experiment, we obtained ${\sim}91^{\circ}C$ and $94^{\circ}C$ for CuO and TiNOX surfaces after 1 hr of solar illumination at single glazing, respectively. To measure the absorber performance at actual operating condition, outdoor experiment was also conducted using $110mm{\times}110mm$ absorber sample. We measured the solar flux with thermopile detector (919P-040-50). From outdoor experiment, we observed ${\sim}123^{\circ}C$ and $131^{\circ}C$ for CuO and TiNOX with 0.6 kW/m2 insolation at double glazing, respectively. We showed that the suggested nanostructured CuO solar absorber has near-equivalent collection efficiency compared with the state-of-the-art TiNOX surfaces even with much simpler manufacturing process that does not require an expensive equipment.

  • PDF

Design for Gwangjang-dong Neighbourhood Park in Gwangjin-gu, Seoul (서울 광진구 광장동 기능 복합적 근린공원 설계)

  • Lee, Gwan-Gyu;Han, Seon-A
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.4 s.117
    • /
    • pp.61-68
    • /
    • 2006
  • A park will soon be developed in an area of Gwangjang-dong, Gwangjin-gu. The place has been a patch of green space for years, isolated by driveways and apartment complexes and abandoned. This article describes plans to infuse the abandoned green space with history, ecology, culture, and sports. The facilities that are to be constructed in and around the green space are positioned to take into account the path of the sun and the location of the curvilinear green space axis. The cultural space is planned as a centerpiece of the park, linked with the sports facilities. The overall framework is arranged in harmony with nearby elementary schools, parks, public facilities, athletic facilities, parking lots, and apartment complexes. The themed circulation route was constructed according to the environmental conditions and the spatial plan. In addition, the historical space is planned to work in close conjunction with the cultural space, and the streets and pedestrian pathways have characters of their own. The established contour lines will be carefully preserved, and an ecological pond will. The facilities, such as the outdoor performance stage, the outdoor art gallery, the Monument of Wind represented by a sail, and the pedestrian bridge in memory of Acha-sansung, are positioned for spatial balance and to provide a nexus. The bamboo forest, designed to foster the experience of sound effects, the architectural thematic plants, and the ecological pond are positioned to connect to each other around the greenspace axis. The main facilities are the outdoor theater, the bamboo forest, the Acha-sansung bridge, the Monument of Wind, the ecological pond, the four-season flower garden, parking lots, playgrounds, circulatory athletic pathways, and the tennis court.

Characteristics of Atmospheric Concentrations of Volatile Organic Compounds and Aldehydes for Near a Shipyard (조선소 주변지역에서 휘발성유기화합물 및 알데히드류의 농도분포 특성)

  • Park, Jeong-Ho;Suh, Jeong-Min;Han, Seong-Jong
    • Journal of Environmental Science International
    • /
    • v.17 no.7
    • /
    • pp.767-774
    • /
    • 2008
  • This study was carried out to evaluate the characteristics of atmospheric concentrations of volatile organic compounds(VOCs) and aldehydes for near a large shipyard. Most of the painting work in marine coating is performed indoor and outdoor. Most of the VOCs are emitted to the atmosphere as the paint is applied and cures. The massive scale of a ship makes it difficult to capture the emissions from outdoor painting. The VOCs are an important health and contributors to photochemical smog. The VOCs and aldehydes samples were collected using adsorbent tube and 2,4-DNPH cartridge, and were determined by an automatic thermal desorption coupled with GC/MS and HPLC-UV analysis, respectively. A total of 16 aromatic VOCs and 12 aldehydes of environmental concern were determined. At indoor coating facilities, the most abundant compound among 16 target VOCs appeared to be m,p-xylene, being followed by o-xylene. But most of the aldehydes were extremely lower concentrations. The atmospheric concentration of VOCs, m,p-xylene concentrations were the highest and the mean value were outdoor workshop 11.323 ppb, residental area 5.134 ppb, and green area 2.137 ppb, respectively. However, the most aldehydes were extremely lower concentrations such as formaldehyde, acetaldehyde and non-detection such as iso-valeraldehyde, n-valeraldehyde and o-tolualdehyde.

A Design and Implementation of Learning System to Support Indoor and Outdoor Field Trips Using RFID Mobile Device (RFID 모바일 기기용 실내.외 체험학습 시스템 설계 및 구현)

  • Yu, Jeong-Su;Baek, Hyeon-Gi
    • Journal of The Korean Association of Information Education
    • /
    • v.14 no.4
    • /
    • pp.527-536
    • /
    • 2010
  • Ubiquitous computing and mobile technologies provide much scope for designing innovative learning experiences that can take place in a variety of indoor and outdoor settings, such as botanical gardens, parks, museums and classrooms. In this paper, we present our own innovative work for bridging indoor and outdoor field-trip learning activities with the support of RFID with reader device on ubiquitous environments. The function of our system is based on strategically located RFID tags placed on objects around settings which are identified using the mobile device installed to an RFID reader. The mobile device reads the RFID tag and sends the learner's request to the field-trip learning system. And learners can be learning activities according to theirs learning levels. We also focus on the use of intelligent agents to customize learning contents for individual learners. The result of our experiment indicates that learner enjoyed learning where mobile devices are used in the system, supporting the learning activities in the context of which they are taking place.

  • PDF

Analysis of Energy Reduction of Free Cooling System with Regions of South Korea (지역별 프리쿨링 시스템의 에너지 절감 분석)

  • Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan;Baek, Seung-Moon;Heo, Jeong-Ho;Kim, Young-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.82-88
    • /
    • 2014
  • Using low outdoor temperature, free cooling system is used in a data center or industrial air-conditioning for energy saving. Because use of IT equipment has increased in some office building recently, there is a growing trend towards using free cooing system. Free cooling system performance is influenced by outdoor temperature. Therefore the performance is different with regions. In this study, performance characteristic of free cooling system is analysed and energy reduction is compared with some regions. Selected regions are 4 cities; including Ulsan analyzed in preceding research, Seoul, ChunCheon and Daejeon. The Aspentech software HYSYS 8.0v was used to conduct the analysis of free cooling system based on temperature per hour of 4 cities in 2013, respectively. The main result is following as. Free cooing system in this study has energy saving effect when outdoor temperature below $7^{\circ}C$. Becuase temperature of Chuncheon is relatively low, using free cooling system can conserve most air-conditioning energy. Energy reduction amount of Seoul is 11%, Chuncheon is 17.5%, Deajeon is 15%, Ulsan is 14%. In case of large scale of air-conditioning, it is reasonable to use free cooling system although the system is used in Seoul.