Fabrication of Ni substrates with [001]-axes tilted textures for depostion of YBCO superconductor (YBCO 초전도체 증착을 위한 [001]-축이 기울어진 Ni 기판의 제작)

  • Kim, Ho-Sup;Lee, Jae-Seoung;Youm, Do-Jun
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.95-98
    • /
    • 1999
  • The crystalline alignment of Ni substrates textured by RABiTS have a probability distribution in the surface plane. This makes it difficult to obtain a high quality of textures over all the range of a long Ni tape. In order to improve the textures of Ni tape, we have investigated a new method of texturing. We obtained non-cube textured Ni tapes by rolling and annealing a high purity Ni. In these tapes, the [001]-axes were tilted around the rolling direction, and the [100]-axes were parallel to the rolling direction. The average grain size was several cm$^2$. We deposited buffer layer (CeO$^2$/YSZ/CeO$^2$) and YBCO on those tapes. We found out that a YBCO film with grows normal with respect to the surface and this feature is independent of the tilting angles of the Ni [001]-axes.

  • PDF

Mechanical Property of Cabon Nanofiber/Polypropylene Composites by Melt-mixing Process (압출공정에 의한 탄소나노섬유/폴리프로필렌 복합재료의 기계적 특성)

  • Byeon, Jun-Hyeong;Lee, Sang-Gwan;Eom, Mun-Gwan;Min, Gyeong-Sik;Song, Jae-Eun;Lee, Chang-Hun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.125-128
    • /
    • 2005
  • The dispersion of carbon nanofiber (CNF) was carried out by solution blending, mechanical mixing, and sonication. CNFs at levels of 5-50% fiber weight content were mixed with polypropylene (PP) powder, and then were melt-mixed using a twin-screw extruder. For the further alignment of fibers, extruded rods were stacked uni-directionally in the mold cavity for the compression molding. For the evaluation of mechanical properties of nanocomposites, tension, in-plane shear, and flexural tests were conducted. CNF/PP composites clearly showed reinforcing effect in the longitudinal direction. The tensile modulus and strength have improved by 100% and 40%, respectively for 50 % fiber weight content, and the flexural modulus and strength have increased by 120% and 25%, respectively for the same fiber weight content. The shear modulus showed 65% increase, but the strength dropped sharply by 40%. However, the property enhancement was not significant due to the poor adhesion between fiber and matrix. In the transverse direction, the tensile, flexural, and shear strength decreased as more fibers were added.

  • PDF

Radiographic Comparison of Cranial Tibial Wedge Osteotomy versus Tibial Plateau Leveling Osteotomy: A Cadaveric Study

  • Lee, Jiyoon;Kim, Dongwook;Oh, Hyejong;Lee, Sungin;Choi, Seok Hwa;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.39 no.3
    • /
    • pp.93-99
    • /
    • 2022
  • The present study was performed to compare cranial tibial wedge osteotomy (CTWO) and tibial plateau leveling osteotomy (TPLO) through radiographic evaluation. The experiment was conducted with five cadaver dogs [mean (± SD) weight, 32.9 ± 4.1 kg; mean (± SD) age, 6 ± 2 years; three males and two females] euthanized for reasons unrelated to this study. The cadaver dogs consisted of German Shepherd (n = 3), Belgian Malinois (n = 1), and mixed breed (n = 1). CTWO and TPLO were carried out by the standard surgical method. Radiographic evaluation was performed by comparing several factors, including the flexion and extension angles, the anatomical mechanical axis angle (AMA-angle), tibial length, patellar height measurement using the Labelle-Laurin method, mechanical medial proximal tibial angle (mMPTA), mechanical medial distal tibial angle (mMDTA), and frontal plane alignment (FPA). Both the CTWO and the TPLO groups showed significantly increased flexion angles after surgery. Only the CTWO group had significantly increased extension angle. Although both groups showed significant decreases in the AMA-angle, the mechanical axis moved cranially against the anatomical axis only in the CTWO group. The patellar height was significantly lowered in the CTWO group. No significant differences were found in mMPTA, mMDTA, or FPA. In conclusion, radiographic comparison revealed more changes in CTWO group than in TPLO group.

Developing Expert System for Recovering the Original Form of Ancient Relics Based on Computer Graphics and Image Processing (컴퓨터 그래픽스 및 영상처리를 이용한 문화 원형 복원 전문가시스템 개발)

  • Moon, Ho-Seok;Sohn, Myung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.6 s.44
    • /
    • pp.269-277
    • /
    • 2006
  • We propose a new expert system for recovering the broken fragments of relics into an original form using computer graphics and image processing. This paper presents a system with an application to tombstones objects of flat plane with letters carved in for assembling the fragments by placing their respective fragments in the right position. The matching process contains three sub-processes: aligning the front and letters of an object, identifying the matching directions, and determining the detailed matching positions. We apply least squares fitting, vector inner product, and geometric and RGB errors to the matching process. It turned out that 2-D translations via fragments-alignment enable us to save the computational load significantly. Based on experimental results from the damaged cultural fragments, the performance of the proposed method is illustrated.

  • PDF

A Study on the Magnetic Anisotrpy and Magnetoresistive Characteristics of NiFe/Cu/Co Trilayers (NiFe/Cu/Co 삼층막의 자기이방성과 자기저항 특성에 관한 연구)

  • 김형준;이병일;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.5
    • /
    • pp.323-328
    • /
    • 1996
  • NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$) trilayers were formed on the $4^{\circ}$ tilt-cut Si(111) substrate by rf magnetron sputtering method. With a Cu($50\;{\AA}$) underlayer, NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$) trilayers developed in-plane magnebc anisotropy and in-plane perpendicular alignment of easy axes in two magnetic components of NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$) trilayers has been found. The easy axis of Co layer consisbng of NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$) trilayers turned out to be along $4^{\circ}$ tilt Si <112> direcbon and that of NiFe layer along Si <110> direction. [NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$)]/Cu($50\;{\AA}$)/Si(111, $4^{\circ}$ tiIt-cut) trilayers showed about 2.2 % MR ratio at room temperature and large plateau in MR curves, which are more improved MR characteristics than those in [NiFe($60\;{\AA}$)/Cu($60\;{\AA}$)/Co($30\;{\AA}$)]/Cu($50\;{\AA}$)/glass trilayers with no appreciable magnetic anisotropy.

  • PDF

Measurement of Tensile Properties for Thin Aluminium Film by Using White Light Interferometer (백색광간섭계를 이용한 알루미늄 박막의 인장 물성 측정)

  • Kim, Sang-Kyo;Oh, Chung-Seog;Lee, Hak-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 2010
  • Thin films play an important role in many technological applications including microelectronic devices, magnetic storage media, MEMS and surface coatings. It is well known that a thin film's material properties can be very different from the corresponding bulk properties and thus there has been a strong need for the development of a reliable test method to measure the mechanical properties of a thin film. We have developed an alternative and convenient test method to overcome the limitations of previous membrane deflection experiment and uniaxial tensile test by adopting a white light interferometer having sub-nanometer out-of-plane displacement resolution. The freestanding aluminium specimens are tested to verity the effectiveness of the test method developed and get the tensile properties. The specimens are 0.5 rum wide, $1{\mu}m$ thick and fabricated through MEMS processes including sputtering. 1 to 5 specimens are fabricated on Si dies. The membrane deflection experiments are carried out by using a homemade tester consisted of a motor-driven loading tip, a load cell, and 6 DOF alignment stages. The test system is compact enough to set it up beneath a commercial white light interferometric microscope. The white light fringes are utilized to align a specimen with the tester. The Young's modulus and yield point stress of the aluminium film are 62 GPa and 247 MPa, respectively.