• 제목/요약/키워드: out gas

검색결과 4,021건 처리시간 0.029초

LP가스 폭발로부터 화재로의 천이에 관한 연구 (A Study on the Explosion to Fire Transition Phenomena of Liquidfied Petroleum Gas)

  • 오규형;이춘하
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.107-113
    • /
    • 1993
  • Small rectangular explosion chamber of its size 25cmX25cmX32cm with a circular bursting diaphram at the top was used to study the mechanism of gas explosion to fire transition phenomena, the process of ignition of solid combustibles during a gas explosion. To visulize the explosion to fire transition phenomena, transparent acryl window and high speed camera system were used. The test piece of solid combustible in this experiments was a 5cm$\times$5cm square sheet of newspaper which was placed in the explosion chamber filled with a LPG-air mixture. The mixture was ignited by an electric spark at the center of the chamber. Explosion to fire transition phenomena and the behavior of out flow and in flow of gas through the opening yielded by bursting the diaphram was visualized with shlieren system and without shlieren system. Diameter of a bursting dlaphram at the top of the explosion chamber was varied 5cm, 10cm, and 15cm, and the position of test piece were varied with 6 point. Explosion pressure was measured with strain type pressure transducer, and the weight difference of the test piece before and after each experimental run was measured. By comparing the weight difference of solid combustibles before and after the experiment and the behavior of out flow and inflow of gas after explosion, it was found that the possibility of ignition was depends on the LPG-air mixture concentration and the exposure period of test piece to the burnt gas. Test result of this experiments it was found that the main factor of this phenomena are that heat transfer to the test piece, and the pyrolysis reaction of test piece. Based on the results, the mechanism of the explosion to fire transition phenomena were inferred ; gas explosion- heat transfer to solid combustibiles ; pyrolysis reaction of solid combutibles : air inflow ; mixing of the pyroly gas with air ignition.

  • PDF

Electrical breakdown properties in neon gas mixed with xenon

  • Han S. Uhm;Park, Eun H.;Guansup Cho;Ki W. Whang
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제4권4호
    • /
    • pp.112-121
    • /
    • 2000
  • The paper investigates electrical discharge properties in neon gas mixed with xenon. The breakdown temperature T$\sub$b/ and voltage V$\sub$b/ are obtained in terms of the gas mixture ratio X. It is shown that the breakdown voltage decreases, reaches the minimum value at X=0.02 and then increases again, as the mixture ratio X increases from zero to unity. Therefore, mixing the neon gas with a few percent of xenon is the most beneficial to reduce the breakdown voltage. Plasma density at breakdown in neon gas mixed with xenon is described in terms of the gas mixture ratio. The optimum value of mixture ratio for highest plasma density is found to be Xm=0.03. A preliminary experiment of AC-PDP is carried out for neon gas mixed with a few percent of xenon to verify some of the theoretical models. The experimental data agree qualitatively well with theoretical predictions.

  • PDF

고온 배기가스의 산소농도가 배기가스이용 확산화염의 $NO_{x}$ 발생에 미치는 영향 (The Effect of Oxygen Concentration in Hot Exhaust Gas on the $NO_{x}$ Emission of Diffusion Flame in Exhaust Gas)

  • 손화승;장시웅;최동수;김호영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.115-120
    • /
    • 2001
  • The present study examined the possibility of $NO_{x}$ reduction in the high temperature industrial furnaces. duct burner of gas turbine cogeneration and two-stage gas turbine combustor. The experimental study was carried out for the diffusion flame of second stage combustor with the variations of oxygen concentration and supplying rate of hot exhaust gas from first stage combustor. It also examined the flammability range and $NO_{x}$ formation of the second stage combustor in which the fuel is supplying into the mixture of oxygen hot exhaust gas from first stage combustor. The results show that the enrichment of oxygen and increase of exhaust gas lead to increase the $NO_{x}$ up to 50 ppm with 23% $O_{2}$ condition.

  • PDF

분무실 밀도 변화가 충돌 디젤분무 특성에 미치는 영향 (The Effect of Ambient Gas Density on the Development of Impinging Diesel Spray)

  • 김종현;이봉수;구자예
    • 한국분무공학회지
    • /
    • 제4권2호
    • /
    • pp.40-46
    • /
    • 1999
  • Experimental investigation of unsteady impinging diesel spray on the flat plate have been carried out using high speed camera and Malvern system. The density ratios of ambient gas to diesel fuel were varied using $N_2$ and Ar gas in the case of 14.9, 21.2, 28.4, 35.1, 40.4, and 50.1. With the increase of gas density ratio, the radial penetration is decreased due to the resistance of the ambient gas. With the increase of the gas density ratio and the distance between nozzle tip and flat plate, the height of spray is increased due to the entrance and circulation. With the increase of gas density ratio, SMD is decreased on the nearby position at the center of flat plate, but SMD is increased on the far position. As the distance between nozzle tip and flat plate is increased, SMD is always decreased.

  • PDF

LNG 연료를 이용한 가스 터빈 연소기의 연소유동 해석 (Analysis of Combustion Flow of LNG-Fueled Gas Turbine Swirl Burner)

  • 김태호;강기하;최정열;김성철
    • 한국연소학회지
    • /
    • 제13권3호
    • /
    • pp.33-40
    • /
    • 2008
  • Two- and Three- dimensional numerical simulations are carried out to understand the combustion characteristics of LNG-fueled gas turbine combustor for power generation using imported and domestic natural gases. Reacting flow characteristics of the swirl stabilized natural gas combustor were understood from the numerical results with the flow conditions selected from the gas turbine operation data. The thermal influences of different natural gases were very small and the fuel composition and flow rate were considered to be tuned well. The flow structures of the recirculation and combustion region was understood from the comparison of the two- and three-dimensional results. The complexity of the three-dimensional swirl flows inside the gas turbine combustor with multiple swirlers was understood those resulting from the interactions of the stage and pilot burners.

  • PDF

다공성 매질 내에서 메탄 하이드레이트의 분해에 의한 2 상 유동 해석 (Simulation of Two Phase Flow in Porous Media After Disso of Methane Hydrates)

  • 장동근;김남진;이재용;김종보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.241-246
    • /
    • 2000
  • Gas hydrates are solid solutions when water molecules are linked through hydrogen bondin create host lattice cavities that can enclose a large variety of guest gas molecules. The natural hydrate crystal may exist at low temperature above the normal freezing point of water and pressure greater than about 30 bars. A lot of quantities of natural gas hydrates exists in the ear many production schemes are being studied. In the present investigation, depressurization method considered to predict the production of gas and the simulation of the two phase flow - gas and - in porous media is being carried out. The simulation show about the fluid flow in porous have a variety of applications in industry. Results provide the appearance of gas and water prod the pressure profile, the saturation of gas/ water/ hydrates profiles and the location of the pl front.

  • PDF

무선센서네트워크 기반 공기질 측정을 위한 비분산적외선 복합가스측정시스템 (NDIR Multi-Gas Measurement System for Air Quality based on Wireless Sensor Network)

  • 백승현;이준영;정상우;박홍배
    • 대한임베디드공학회논문지
    • /
    • 제11권5호
    • /
    • pp.299-304
    • /
    • 2016
  • As public interest in air quality and environment problem is increasing, many researches are being carried out the gas measurement system. Especially, Non-dispersive infrared (NDIR) measurements using Beer-Lambert gas sensing principle with very high selectivity and long life time are noted for reliable method. It is possible to detect various gases such as carbon dioxide (CO2), carbon monoxide (CO), and nitrogen dioxide (NO2), but many researches are mostly concentrated on CO2 sensor. The multi-gas measuring instrument is high price and unwieldy, therefore it is not suitable for wide area required numerous instrument. So we study the NDIR multi-gas measurement system for air quality based on wireless sensor network, and experiment the realized measurement system.

로타리 압축기의 가스맥동에 관한 연구 (A Study on the Gas Pulsation in a Rotary Compressor)

  • 김현진
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.648-655
    • /
    • 2002
  • For a discharge system of rotary compressor, analytical investigation on the discharge gas pulsation has been carried out. With the aid of four pole theory, acoustic impedance of the discharge system composed of muffler and cavities on both sides of motor with gas passages between them can be calculated using discrete acoustic elements described by transfer matrices, yielding the relationship between discharge mass flow rate and gas pulsation at the discharge port. This method of predicting the gas pulsation was validated by measurement data. Effects of change in discharge muffler geometries on the gas pulsation also were investigated, demonstrating that this method can be used for muffler design.

가정용 LP가스 조정기 차단안전장치의 개발 (Development of a Shut-off Device of LP Gas Regulator for Home Use)

  • 김영규;김필종;권부길;박교식;김지윤
    • 한국가스학회지
    • /
    • 제10권3호
    • /
    • pp.54-59
    • /
    • 2006
  • 가정용 LPG 가스시설에 사용되고 있는 압력조정기에서 체결된 호스가 분리되거나 또는 고의로 절단하여 발생하는 가스사고 및 고의사고를 예방하기 위해서 조정기 출구에 차단기능을 갖는 안전장치를 개발하였다. 본 연구를 통하여 개발된 차단안전장치의 작동성과 현장 적용여부를 확인하기 위하여 조정기의 설치상태에 따른 시험과, 가정집에서의 현장시험을 실시하였다. 시험결과 입구압력 $0.07{\sim}1.56MPa$의 조건에서 조정기의 설치상태와는 무관하게 호스길이 5 m이내에서 차단되었고, 차단유량은 수직상향, 수평, 수직하향의 순서로 높게 나타났다. 또한 가정집에 설치하여 5개월 시험한 결과, 가스레인지나 보일러를 사용하는데 있어 문제점은 없는 것으로 나타났다. 개발된 조정기 차단안전장치가 상용화되어 보급된다면 호스분리나 절단에 따른 사고를 대폭적으로 예방하는데 크게 기여할 수 있을 것으로 기대된다.

  • PDF

수소타운 정압기실 내 수소 누출 특성 연구 (A Study on Characteristics of Hydrogen Leakage in Hydrogen Town Governor Room)

  • 남태호;김동환;이정운;이승국;이연재
    • 한국수소및신에너지학회논문집
    • /
    • 제27권6호
    • /
    • pp.685-692
    • /
    • 2016
  • Hydrogen will be a future eco-friendly energy source that can replace current fossil fuels However when hydrogen gas leaks and people inhale a lot of hydrogen gases, they can have fatal effects fell into comas. Therefore, we need to develop a safety technology and related guidelines for reducing risks of hydrogen leakage. In this regard, we carried out demonstration tests assuming a situation of hydrogen leakage. Before the experiments, we analyze the standards for governor facilities to check vent positions and sensor positions. Then, we select four types of ventilation structures and proceeds with the experiments of hydrogen leakage at 1 LPM and 1.5 LPM. Based on the experimental results, we propose the direction on optimization of vent positions and sensor positions in the hydrogen leakage situation.