Objective: To assess the efficacy of cervical open-door laminoplasty by hydroxyapatite implant insertion between the lamina and the lateral mass without suturing. Methods: All patients who underwent cervical open-door laminoplasty with C2/C7 undermining and insertion of hydroxyapatite implants from C3 to C6 were retrospectively evaluated for surgical time and neurological outcomes according to the Japanese Orthopaedic Association (JOA) score. To assess the alignment of the cervical spine and postoperative cervical pain, the C2-7 angle and a visual analogue scale score were used, respectively. Results: The population consisted of 102 women and 222 men ranging in age from 32 to 90 years. The average surgical time was 86 minutes. Fourteen of 1,296 hydroxyapatite implants were kept in place with sutures due to a weak restoration force of the hinge during surgery. No hydroxyapatite implant dislocation was detected on cervical computed tomography at 1 year after surgery. The average JOA score was $10.2{\pm}2.5$ before surgery and $14.6{\pm}2.8$ at 1 year after surgery. The average recovery rate was 61.8%. The average C2-7 angle at the neutral position was $7.1^{\circ}{\pm}6.2^{\circ}$ before surgery and $6.5^{\circ}{\pm}6.3^{\circ}$ at 1 year after surgery. Conclusion: This method enabled us to achieve minimal exposure of the lateral mass, prevention of lateral mass injury and dural injury, and a shorter surgical time while maintaining acceptable surgical outcomes. The idea that firm suture fixation is needed to prevent spacer deviation during cervical open-door laminoplasty may need to be revisited.
Purpose: It is very important to evaluate and fix coronoid process fractures because they are a critical element for a stable, effective elbow function. The lateral view of the elbow joint is used for a radiographic evaluation of the coronoid but an understanding of the fracture pattern is often difficult because of overlap of the radial head and obliquity of the fracture line. We developed the coronoid view, which is a new radiograph for an evaluation of the coronoid process fracture, and discuss its advantages for a postoperative follow-up. Materials and Methods: The coronoid view was designed for an evaluation of the anteromedial fragment of the coronoid process. After the patient sat on his side, the shoulder was abducted $45^{\circ}$ and the elbow was flexed $90^{\circ}$. The X-ray beam was shot perpendicular to the table. Since shoulder was abducted $45^{\circ}$ the fracture line of the coronoid process can be parallel to the X-ray beam, and the radial head can be cleared. Conclusion: The coronoid view can be a good alternative radiograph for an evaluation of a coronoid process fracture because the beam is parallel to the fracture line. The coronoid view can be particularly useful in postoperative patient follow-up where computed tomography is impractical due to metal implants and cost.
The Co-Cr alloys have clinical histories in dental and orthopaedic implants, and recently in cardiovascular stent applications because the alloys exhibit a high elastic modulus and radiopacity. In order to improve mechanical property of the Co-Cr alloys, electropolishing is employed as the final process. Electropolishing, an anodic dissolution process in the transpassive state, is sensitively affected by process conditions such as current density, machining time, electrode gap. In this study, the effect of heat treatment conditions on surface roughness and inclusion analysis is investigated in Co-Cr alloy (L605). The most smooth surface of Co-Cr alloy is obtained when electropolishing is performed at 15-20 V for 15-30 sec with a electrode gap of 3.5 mm.
The Co-Cr alloys have clinical histories as dental and orthopaedic implants, and recently as cardiovascular stent applications because they exhibit a high elastic modulus and radiopacity. In order to improve their mechanical and corrosion resistance, electropolishing is employed as the final process. Electropolishing, an anodic dissolution process in the transpassive state, is sensitively affected by process conditions such as current density, machining time, and electrode gap. In this study, the effect of the electropolishing conditions on surface roughness and corrosion resistance is investigated for Co-Cr alloys (L605). The most smooth surface is obtained when electropolishing is performed at 15-20 V for 15-30 sec with a electrode gap of 3.5 mm. It is found out that electropolishing reduces corrosion rate about one-tenth as much.
Although current surgical techniques have reduced the incidence of malunion, it is still observed because of the complexity of the fracture or associated injuries. Osteotomy is needed when the amount of malunion is expected to result in an overload of cartilage and instability of the joint. Preoperative planning is essential when performing an osteotomy for malunion. Inadequate planning can result in serious complications, such as iatrogenic malalignment, intraoperative fracture, postoperative recurrence of deformity, or soft tissue injuries. In addition, a poor functional result can occur secondary to poor patient selection. This review article includes the surgical indications and planning to correct malunion. Various methods of corrective osteotomy are described according to the kinds of plane and fixation implants.
Lee, Young-Kyun;Choi, Ji Hye;Won, Heejae;Koo, Kyung-Hoi
Journal of the Korean Orthopaedic Association
/
v.54
no.5
/
pp.377-383
/
2019
The biomechanics study of the hip is aims to understand and explore the dynamic principles of weight transfer through the hip joint. This basic science knowledge can be applied in a variety of areas, including degenerative joint diseases and hip replacement arthroplasty. In particular, understanding of the biomechanics of the hip has led to the development of materials, design and fixation of implants, and it can be applied in various areas, such as the selection of surgical methods and the location of the implant. Moreover, it is essential to have good knowledge of the biomechanics of the hip to achieve better clinical results for patients. Therefore, this paper introduces the basic knowledge and biomechanical characteristics of a normal hip and hip replacement arthroplasty, which are needed to approach the biomechanics of the hip.
Ahmed Mohamed Desouky;Ahmed Naeem Atiyya;Mohamed Elbishbishi;Marwa Mohamed El Sawy
Anatomy and Cell Biology
/
v.56
no.1
/
pp.39-45
/
2023
Fixation of radial head fracture with minimally invasive posterior approach remains a significant challenge. The aim of this study was to determine the feasibility of trans-anconeus posterior elbow approach and to observe lateral ulnar collateral ligament (LUCL) in extended elbows. This cadaveric study was performed in twenty upper limbs of fresh fixed adult male cadavers. An oblique incision was made in the middle segment of anconeus until the lateral ligament complex and the joint capsule had been revealed. A deep dissection was explored to observe the anatomical relationship of the LUCL to the anconeus. Measurements of the LUCL were recorded while the elbow was fully extended. The mean distance between the edge of the radial head and the proximal insertion of the LUCL was 13.3 mm (11.5-16.2 mm); the mean distance between the edge of the radial head and the distal insertion of the LUCL was 20.9 mm (19.2-23.4 mm); the distance between the edge of the radial head and the distal edge of the annular ligament was 11.2 mm (8.22-11.7 mm). By estimate correlation of the previous measurements, the direct and accessible way to expose the posterolateral articular capsule of the elbow joint was through a window in medial 2/3 of the middle segment of anconeus muscle. These trans-anconeus approach is useful. It provides good visualization, facilitates applying the implants, and lessens the risk of radial nerve injury. Awareness of the anatomy is mandatory to avoid injury of LUCL.
The Journal of the Korean bone and joint tumor society
/
v.8
no.1
/
pp.1-11
/
2002
Purpose : We evaluated the radiological and functional results of prosthetic reconstruction for locally aggressive benign and malignant tumor in the lower extremity. Materials and Methods : Eighty eight patients were followed up for an average 76 months(22~174). We examined the survival rate of prosthesis, and evaluated the final result by MSTS functional score and ISOLS radiological implants evaluation system. They were statistically analyzed according to the age(<20 year vs. ${\geq}$20 year), fixation methods, amount of bony resection, chemotherapy, local recurrence, and presence of metastasis. Results : The 5 year prosthetic survival rates were 100% in the proximal femur, 83.3% in the distal femur, 81.9% in the proximal tibia. Mean total functional scores were 73.3%, 72%, 68.7%, respectively. In distal femur, the non-chemotherapeutic group was superior in the prosthetic survival rate. Recurrence or metastasis affected the functions in the distal femur and proximal tibia. In the radiological evaluation of the distal femur, older patients over 20 years of age and with cement fixation were superior in bone remodeling(p<0.05). Postoperative infection and radiological loosening were the main causes of the prosthetic failure. Conclusion : The prosthetic reconstruction in the lower extremity led to good clinical and radiological results. Amount of bony resection, chemotherapy, recurrence and metastasis seemed to influence the prosthetic survival, and long-term follow-up will be necessary to investigate more significant prognostic factors.
Park, Po-Young;Kim, Young-Ki;Bahk, Jong-Yoon;Park, Joung-Man;Koh, Phil-Ok;Chang, Hong-Hee;Lee, Hee-Chun;Lee, Hyo-Jong;Yeon, Seong-Chan
Journal of Veterinary Clinics
/
v.24
no.2
/
pp.182-191
/
2007
Bioabsorbable devices have been utilized and experimented in many aspects of orthopaedic surgery. Depending upon their constituent polymers, these materials can be tailored to provide sufficient rigidity to allow bone healing, retain mechanical strength for certain period of time, and then eventually begin to undergo degradation. The objective of this study was to estimate extent in which Poly-L-latic acid (PLLA) implants had bioabsorbability and biocompatibility with bone and soft tissue in dogs and also to develop bioabsorbable, biocompatible materials with the appropriate strength and degradation characteristics to allow for regular clinical use for treating orthopedic problems in humans as well as animals. Eighteen dogs were used as experimental animals and were inserted two types of PLLA implants. PLLA rods were inserted into subcutaneous tissue of back or the abdomen wall. And the rods were tested for material properties including viscosity, molecular weight, melting point, melting temperature, crystallinity, flexural strength, and flexural modulus over time. PLLA screws were inserted through cortical bone into bone marrow in the femur of the dogs and stainless steel screw was inserted in the same femur. Radiographs were taken after surgery to observe locations of screw. Histological variations including cortical bone response, muscular response, bone marrow response were analyzed over the time for 62weeks. The physical properties of PLLA rods had delicate balances between mechanical, thermal and viscoelastic factors. PLLA screws did not induce any harmful effects and clinical complications on bone and soft tissue for degradation period. These results suggest that PLLA implants could be suitable for clinical use.
The Journal of the Korean bone and joint tumor society
/
v.17
no.1
/
pp.36-43
/
2011
Purpose: This study was designed to verify intermediate-term functional and radiological results of limb salvage operation using endoprosthetic replacement system ($MUTARS^{(R)}$) used in patients with a malignant bone tumor. Materials and Methods: Thirty one cases which used $MUTARS^{(R)}$ tumor prosthesis were reviewed. The mean age of the patients was 49.2 years and the mean follow up was 39.8 months. We retrospectively reviewed complications, and evaluated functionally and radiologically by Enneking functional score, ISOLS radiological implants evaluation system at last follow-up. Results: 3 patients had died of disease, distant metastasis was seen in 4 patients and local recurrence was seen in 1 patients. Complications were developed in 12 patients. (infection 6, leg length discrepancy 2, aseptic loosening 2, periprosthetic femoral fracture 1, screw loosening 1) Mean value of total functional scores were 81.2% in proximal femur, 77.4% in distal femur, 78.1% in proximal tibia, and 80.2% in proximal humerus. The overall radiological result was relatively satisfactory. Conclusion: Our results suggest limb salvage with the $MUTARS^{(R)}$ endoprosthesis is successful with good functional and radiological results. But we should be careful with complications such as infection.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.