• 제목/요약/키워드: orthopaedic implants

검색결과 38건 처리시간 0.017초

Safety of Temporary Use of Recycled Autoclaved Femoral Components in Infected Total Knee Arthroplasty: Confirming Sterility Using a Sonication Method

  • Park, Hyung-Jin;Kim, Hee-June;Kim, Shukho;Kim, Seong-Min;Mun, Jong-Uk;Kim, Jungmin;Kyung, Hee-Soo
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.427-432
    • /
    • 2018
  • Background: The purpose of this study was to evaluate the usefulness of sonication technique for microbiological diagnosis and the sterility of the recycled autoclaved femoral components from infected total knee arthroplasty (TKA) using a sonication method. Methods: Nineteen femoral implants explanted from patients with infected TKA were sterilized with a standard autoclave method. Standard culture of the fluid before and after sonication of the sterilized implants was performed to detect pathogenic microorganisms. Additional experiments were performed to evaluate the sterility of the recycled implant by inducing artificial biofilm formation. Methicillin-resistant Staphylococcus aureus (MRSA) was inoculated into 10 implants and sterilization in a standard autoclave was performed, and then the fluid was cultured before and after sonication. Results: Two of the 19 sterilized implants were positive for growth of bacteria after sonication, whereas no growth was detected in the cultured fluid from the sterilized implants before sonication. The bacteria were Staphylococcus species in all two cases. In one of 10 implants inoculated with MRSA, the culture was positive for growth of bacteria both before and after sonication. However, Staphylococcus epidermidis was cultured from both occasions and thus this implant was thought to be contaminated. Conclusions: We found sonication for identification of pathogens could be helpful, but this finding should be interpreted carefully because of the possibility of contamination. Sterilization of an infected femoral implant with an autoclave method could be a good method for using the temporary articulating antibiotic spacer in two-stage revision arthroplasty.

Patient-specific implants in reverse shoulder arthroplasty

  • Emil R Haikal;Mohamad Y. Fares;Joseph A. Abboud
    • Clinics in Shoulder and Elbow
    • /
    • 제27권1호
    • /
    • pp.108-116
    • /
    • 2024
  • Reverse total shoulder arthroplasty (RTSA) is widely popular among shoulder surgeons and patients, and its prevalence has increased dramatically in recent years. With this increased use, the indicated pathologies associated with RTSA are more likely to be encountered, and challenging patient presentations are more likely to be seen. One prominent challenging presentation is RTSA patients with severe glenoid bone loss. Several techniques with varying degrees of invasiveness, including excessive reaming, alternate centerline, bone grafting, and patient-specific implants (PSIs), have been developed to treat patients with this presentation. PSI treatment uses a three-dimensional reconstruction of a computed tomography scan to design a prosthetic implant or component customized to the patient's glenoid morphology, allowing compensation for any significant bone loss. The novelty of this technology implies a paucity of available literature, and although many studies show that PSIs have good potential for solving challenging shoulder problems, some studies have reported questionable and equivocal outcomes. Additional research is needed to explore the indications, outcomes, techniques, and cost-efficiency of this technology to help establish its role in current treatment guidelines and strategies.

Influence of lateralized versus medialized reverse shoulder arthroplasty design on external and internal rotation: a systematic review and meta-analysis

  • Kevin A. Hao;Robert J. Cueto;Christel Gharby;David Freeman;Joseph J. King;Thomas W. Wright;Diana Almader-Douglas;Bradley S. Schoch;Jean-David Werthel
    • Clinics in Shoulder and Elbow
    • /
    • 제27권1호
    • /
    • pp.59-71
    • /
    • 2024
  • Background: Restoration of external (ER) and internal rotation (IR) after Grammont-style reverse shoulder arthroplasty (RSA) is often unreliable. The purpose of this systematic review was to evaluate the influence of RSA medio-lateral offset and subscapularis repair on axial rotation after RSA. Methods: We conducted a systematic review of studies evaluating axial rotation (ER, IR, or both) after RSA with a defined implant design. Medio-lateral implant classification was adopted from Werthel et al. Meta-analysis was conducted using a random-effects model. Results: Thirty-two studies reporting 2,233 RSAs were included (mean patient age, 72.5 years; follow-up, 43 months; 64% female). The subscapularis was repaired in 91% (n=2,032) of shoulders and did not differ based on global implant lateralization (91% for both, P=0.602). On meta-analysis, globally lateralized implants achieved greater postoperative ER (40° [36°-44°] vs. 27° [22°-32°], P<0.001) and postoperative improvement in ER (20° [15°-26°] vs. 10° [5°-15°], P<0.001). Lateralized implants with subscapularis repair or medialized implants without subscapularis repair had significantly greater postoperative ER and postoperative improvement in ER compared to globally medialized implants with subscapularis repair (P<0.001 for both). Mean postoperative IR was reported in 56% (n=18) of studies and achieved the minimum necessary IR in 51% of lateralized (n=325, 5 cohorts) versus 36% (n=177, 5 cohorts) of medialized implants. Conclusions: Lateralized RSA produces superior axial rotation compared to medialized RSA. Lateralized RSA with subscapularis repair and medialized RSA without subscapularis repair provide greater axial rotation compared to medialized RSA with subscapularis repair. Level of evidence: 2A.

Dislocation after Revision Total Hip Arthroplasty: A Comparison between Dual Mobility and Conventional Total Hip Arthroplasty

  • Hyun Sik Shin;Dong-Hong, Kim;Hyung Seok Kim;Hyung Seob Ahn;Yeesuk Kim
    • Hip & pelvis
    • /
    • 제35권4호
    • /
    • pp.233-237
    • /
    • 2023
  • Purpose: The objective of this study was to analyze the results from a cohort of patients who underwent a revision total hip arthroplasty (THA) using a dual mobility cup (DMC) implant. Materials and Methods: A retrospective review of revised THAs was conducted using the database from a single tertiary referral hospital. A total of 91 revision THAs from 91 patients were included in the study. There were 46 male hips and 45 female hips. The mean age was 56.3±14.6 years, and the mean follow-up period was 6.4±5.9 years. In performance of revision THAs, the DMC implants were used in 18 hips (19.8%), and the conventional implants were used in 73 hips (80.2%). Results: During the follow-up period, three dislocations were identified, and the overall dislocation rate was 3.3%. Early dislocation (at one month postoperatively) occurred in one patient, while late dislocation (at a mean of 7.5 years) occurred in two patients. There was no occurrence of dislocation in the DMC group (0%), and three dislocations were detected in the conventional group (4.1%). However, no significant difference in the rate of dislocation was observed between the two groups (P=0.891). Conclusion: Although the rate of dislocation was higher in the conventional group, there were no statistically significant differences between the two groups due to the small number of patients. Nevertheless, we believe that the dual mobility design is advantageous in terms of reducing dislocation rate and can be recommended as an option for a revision THA.

전경골 동맥에서 기시한 가성 동맥류의 코일 색전술: 증례 보고 (Coil Embolization of a Pseudoaneurysm of the Anterior Tibial Artery: A Case Report)

  • 왕태현;조형래;박기봉;김덕희
    • 대한족부족관절학회지
    • /
    • 제20권1호
    • /
    • pp.43-45
    • /
    • 2016
  • Development of a pseudoaneurysm around the ankle is an uncommon complication after surgery. We experienced a case of a pseudoaneurysm, which developed from the anterior tibial artery. A 44-year-old woman had sustained painful swelling of her right ankle after the removal of implants for a distal fibular fracture. The pseudoaneurysm was confirmed by ultrasonography and angiography. The patient was treated with an intervention using a coil and recovered without further complaints. This case report aims to increase the awareness of this complication with review of literature.

Use of custom glenoid components for reverse total shoulder arthroplasty

  • Punyawat Apiwatanakul;Prashant Meshram;Andrew B. Harris;Joel Bervell;Piotr Lukasiewicz;Ridge Maxson;Matthew J. Best;Edward G. McFarland
    • Clinics in Shoulder and Elbow
    • /
    • 제26권4호
    • /
    • pp.343-350
    • /
    • 2023
  • Background: Our purpose was to evaluate a custom reverse total shoulder arthroplasty glenoid baseplate for severe glenoid deficiency, emphasizing the challenges with this approach, including short-term clinical and radiographic outcomes and complications. Methods: This was a single-institution, retrospective series of 29 patients between January 2017 and December 2022 for whom a custom glenoid component was created for extensive glenoid bone loss. Patients were evaluated preoperatively and at intervals for up to 5 years. All received preoperative physical examinations, plain radiographs, and computed tomography (CT). Intra- and postoperative complications are reported. Results: Of 29 patients, delays resulted in only undergoing surgery, and in three of those, the implant did not match the glenoid. For those three, the time from CT scan to implantation averaged 7.6 months (range, 6.1-10.7 months), compared with 5.5 months (range, 2-8.6 months) for those whose implants fit. In patients with at least 2-year follow-up (n=9), no failures occurred. Significant improvements were observed in all patient-reported outcome measures in those nine patients (American Shoulder and Elbow Score, P<0.01; Simple Shoulder Test, P=0.02; Single Assessment Numeric Evaluation, P<0.01; Western Ontario Osteoarthritis of the Shoulder Index, P<0.01). Range of motion improved for forward flexion and abduction (P=0.03 for both) and internal rotation up the back (P=0.02). Pain and satisfaction also improved (P<0.01 for both). Conclusions: Prolonged time (>6 months) from CT scan to device implantation resulted in bone loss that rendered the implants unusable. Satisfactory short-term radiographic and clinical follow-up can be achieved with a well-fitting device. Level of evidence: III.

Bioactivity of Calcium Phosphate Ceramic Coatings on Metallic Implants

  • Kim, Cheol-Sang;Ducheyne, P.
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권1호
    • /
    • pp.5-12
    • /
    • 1990
  • Calcium phosphate ceramics have been applied intensively to orthopaedic and dental implants by virtue of their osteoconductive nature. In an attempt to enhance the bone implant intergrity and Eta utility, these ceramics are deposited onto the porous surface of metallic implants. The coating procedure and the ensuing phase transformations of the ceramic alter the mechanical properties and surface chemistry of the ceramic layers as well as those of the substrate. These structural and compositional differences are directly related to the interaction mechanisms at the surface-active ceramicbone interface. Material and processing induced influences on dissolution, electrokinetic behavior, ceramic-metallic substrate interface and boRe growth enhancement are presented.

  • PDF

3차원 프린팅 기술과 이를 활용한 골종양 수술 (Three Dimensional Printing Technique and Its Application to Bone Tumor Surgery)

  • 강현귀;박종웅;박대우
    • 대한정형외과학회지
    • /
    • 제53권6호
    • /
    • pp.466-477
    • /
    • 2018
  • 정형외과는 인체의 모든 근골격계를 담당하기 때문에 3차원(3-dimensional, 3D) 프린팅 기술을 가장 많이 활용할 수 있는 분야이다. 구체적으로 관절염, 척추, 외상, 기형, 종양 등의 다양한 정형외과 질병에 대해 해부학적 모델, 수술용 가이드, 금속 임플란트, 바이오-세라믹 재건, 보조기 등의 형태로 활용될 수 있다. 특히 정형외과 종양 영역은 환자마다 종양의 발생 위치와 크기가 다양한 데 반하여 사지 보존 수술에 활용할 수 있는 기존의 수술 방법이 제한적이었기 때문에 3D 프린팅 기술의 활용이 매우 절실한 분야였다. 최근에 3D 프린팅 환자 맞춤형 임플란트를 짧은 시간 내에 쉽게 제작할 수 있게 되면서 기존 방법으로 골 재건이 어려웠던 부위에 대해서도 해부학적 재건이 가능하게 되었다. 3D 프린팅 기술을 의료 영역에서 더욱 폭넓게 사용하기 위해서는 디자인, 출력, 검증 과정에 필요한 많은 전문가들과 함께 수평적 위치에서 긴밀히 협력해야 한다. 의료계에서 3D 프린팅을 활용을 선도함으로써 다른 분야의 전문가 양성 및 3D 프린팅 관련 산업의 발달을 촉진시킬 수 있다고 판단한 정부도 규제보다는 활성화에 역점을 두고 적극적으로 지원하고 있는 추세이다. 앞으로 정형외과가 전체 의료계에서 3D 프린팅 기술의 도입과 활용을 선도해 가기를 기대하면서 골종양 수술에서 3D 프린팅 기술을 활용하였던 저자의 경험을 소개하고자 한다.

Novel Hybrid Hydroxyapatite Spacers Ensure Sufficient Bone Bonding in Cervical Laminoplasty

  • Tanaka, Nobuhiro;Nakanishi, Kazuyoshi;Kamei, Naosuke;Nakamae, Toshio;Kotaka, Shinji;Fujimoto, Yoshinori;Ochi, Mitsuo;Adachi, Nobuo
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.1078-1084
    • /
    • 2018
  • Study Design: Prospective observational study. Purpose: This prospective analysis aimed to evaluate the efficacy and bone-bonding rate of hybrid hydroxyapatite (HA) spacers in expansive laminoplasty. Overview of Literature: Various types of spacers or plates have been developed for expansive laminoplasty. Methods: Expansive open-door laminoplasty was performed in 146 patients with cervical myelopathy; 450 hybrid HA spacers and 41 autogenous bone spacers harvested from the spinous processes were grafted into the opened side of each lamina. The patients were followed up using computed tomography (CT), and their bone-bonding rates for hybrid HA and autogenous spacers, bone-fusion rates of the hinges of the laminae, and complications associated with the implants were then examined. Results: Clinical symptoms significantly improved in all patients, and no major complications related to the procedure were noted. The hybrid HA spacers exhibited sufficient bone bonding on postoperative CT. The hinges completely fused in over 95% patients within 1 year of the procedure. Only 4 spacers (0.9%) developed lamina sinking, and most expanded laminae maintained their positions without sinking or floating throughout the follow-up period. Conclusions: Hybrid HA spacers contributed to high bone-fusion rates of the spacers and hinges of the laminae, and no complications were associated with their use. Cervical laminoplasty with these spacers is safe and simple, and it yields sufficient fixation strength while ensuring sufficient bone bonding during the immediate postoperative period.

Variation of Practice in Prophylactic Protocol to Reduce Prosthetic Joint Infection in Primary Hip and Knee Arthroplasty: A National Survey in the United Kingdom

  • James Morris;Lee Hoggett;Sophie Rogers;John Ranson;Andrew Sloan
    • Hip & pelvis
    • /
    • 제35권4호
    • /
    • pp.228-232
    • /
    • 2023
  • Purpose: Prosthetic joint infection (PJI) has an enormous physiological and psychological burden on patients. Surgeons rightly wish to minimise this risk. It has been shown that a standardised, evidence-based approach to perioperative care leads to better patient outcomes. A review of current practice was conducted using a cross-sectional survey among surgeons at multiple centers nationwide. Materials and Methods: An 11-question electronic survey was circulated to hip and knee arthroplasty consultants nationally via the BOA (British Orthopaedic Association) e-newsletter. Results: The respondents included 56 consultants working across 19 different trusts. Thirty-four (60.7%) screen patients for asymptomatic bacteriuria (ASB) preoperatively, with 19 (55.9%) would treating with antibiotics. Fifty-six (100%) screen for methicillin-resistant Staphylococcus aureus and treat if positive. Only 15 (26.8%) screen for methicillin-sensitive S. aureus (MSSA) or empirically eradicate. Zero (0%) routinely catheterize patients perioperatively. Forty-one (73.2%) would give intramuscular or intravenous gentamicin for a perioperative catheterisation. All surgeons use laminar flow theatres. Twenty-six (46.4%) use only an impervious gown, 6 (10.7%) exhaust pipes, and 24 (42.3%) surgical helmet system. Five different antimicrobial prophylaxis regimens are used 9 (16.1%) cefuroxime, 2 (3.6%) flucloxacillin, 19 (33.9%) flucloxacillin and gentamicin, 10 (17.9%) teicoplanin, 16 (28.6%) teicoplanin and gentamicin. Twenty-two (39.3%) routinely give further doses. Conclusion: ASB screening, treatment and intramuscular gentamicin for perioperative catheterisation is routinely practiced despite no supporting evidence base. MSSA screening and treatment is underutilised. Multiple antibiotic regimens exist despite little variation in organisms in PJI. Practice varies between surgeons and centers, we should all be practicing evidence-based medicine.