• Title/Summary/Keyword: orthogonal components

Search Result 174, Processing Time 0.022 seconds

Analysis on Electric Field Based on Three Dimensional Atmospheric Electric Field Apparatus

  • Xing, Hong-yan;He, Gui-xian;Ji, Xin-yuan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1697-1704
    • /
    • 2018
  • As a key component of lighting location system (LLS) for lightning warning, the atmospheric electric field measuring is required to have high accuracy. The Conventional methods of the existent electric field measurement meter can only detect the vertical component of the atmospheric electric field, which cannot acquire the realistic electric field in the thunderstorm. This paper proposed a three dimensional (3D) electric field system for atmospheric electric field measurement, which is capable of three orthogonal directions in X, Y, Z, measuring. By analyzing the relationship between the electric field and the relative permittivity of ground surface, the permittivity is calculated, and an efficiency 3D measurement model is derived. On this basis, a three-dimensional electric field sensor and a permittivity sensor are adopted to detect the spatial electric field. Moreover, the elevation and azimuth of the detected target are calculated, which reveal the location information of the target. Experimental results show that the proposed 3D electric field meter has satisfactory sensitivity to the three components of electric field. Additionally, several observation results in the fair and thunderstorm weather have been presented.

Stator Flux Oriented Sensorless Vector Control with Phase/Gain Compensated LPF for Induction Motor (유도전동기를 위한 위상/이득 보상 LPF를 가지는 고정자 자속 기준 센서리스 벡터 제어)

  • Park Seung-Yub;Kim Sam-Young
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.4
    • /
    • pp.201-207
    • /
    • 2005
  • This paper has investigated the sensorless vector control method of induction motor based on the stator flux oriented voltage equation and the digital low pass filter (LPF) with compensator of phase/gain. The Proposed vector control method is easy to decide the stator reference voltages and control of motor, since it is based on stator flux vector But this method has sensitive structure to excessive sensor noise and PWM pulsating components of stator currents because the measured stator currents are directly used to compensate the internal resistive voltage drop at the determination of stator reference voltages. To eliminate the noise sensitive of proposed vector drive, this paper propose the digital LPF with compensator of phase/gain base on orthogonal property of stator current vector in stationary $\alpha$, $\beta$ reference frame. The proposed methods have been simulated and implemented on a sensorless vector drive for 750W three-phase induction motor. The simulation and experimental results demonstrate effectiveness of the proposed methods.

Development of Stereoscopic PIV Measurement Technique and Its Application to Wake behind an Axial Fan (Stereoscopic PIV 기법의 개발과 이를 이용한 축류 홴 후류의 유동해석)

  • Yun, Jeong-Hwan;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.362-373
    • /
    • 2002
  • A stereoscopic PIV (SPIV) measurement system based on the translation configuration was developed and applied to the flow behind a forward-swept axial-fan. Measurement of three orthogonal velocity components is essential for flow analysis of three-dimensional flows such as flow around a fan or propeller. In this study, the translation configuration was adopted to calculate the out-of-plane velocity component from 2-D PIV data obtained from two CCD cameras. The error caused by the out-of-plane motion was estimated by direct comparison of the 2-D PIV and 3-D SPIV results that measured from the particle images captured simultaneously. The comparison shows that the error ratio is relatively high in the region of higher out-of-plane motion near the axial fan blade. The turbulence intensity measured by the 2-D PIV method is bigger by about 5.8% in maximum compared with that of the 3-D SPIV method. The phase-averaged velocity field results show that the wake behind an axial fan has a periodic flow structure with respect to the blade phase and the characteristic flow structure is shifted downstream in the next phase.

Bus Clamping PWM Based Hysteresis Current Controlled VSI Fed Induction Motor Drive with Nearly Constant Switching Frequency

  • Peter, Joseph;Mohammed Shafi, KP;Ramchand, Rijil
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1523-1534
    • /
    • 2017
  • A Current Error Space Phasor (CESP) based hysteresis controller with online computation of the boundary for two-level inverter fed Induction Motor (IM) drives is presented in this paper. The stator voltages estimated along the ${\alpha}$-and ${\beta}$-axes and the orthogonal current error components of the motor are used in the online computation of the hysteresis boundary. All of the inherent benefits of space phasor based hysteresis controllers such as its quick dynamic response and nearby voltage vector switching are present in the proposed scheme with the added benefit of suppressing switching frequency variations. The similarity in the frequency spectrum of the phase voltage obtained at the output of the inverter using the proposed scheme and Bus Clamping Pulse Width Modulation (BCPWM) based drive is justified with the help of extensive MATLAB SIMULINK simulations. The controller is experimentally verified with a three phase, 2.2 kW IM drive for steady state and transient conditions and the obtained results match the simulation results.

Fabry-Perot Filter Constructed with Anisotropic Space Layer and Isotropic Mirrors

  • Qi, Hongji;Hou, Yongqiang;Yi, Kui;Shao, Jianda
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.33-37
    • /
    • 2013
  • In this study a new design concept of the Fabry-Perot filter, constructed with an anisotropic space layer and a couple of isotropic mirrors, was proposed based on the Maxwell equations and the characteristic matrix method. The single- and double-cavity Fabry-Perot filters were designed, and their optical properties were investigated with a developed software package. In addition, the dependence of the transmittance and phase shift for two orthogonal polarization states on the column angle of the anisotropic space layer and the incidence angle were discussed. We demonstrated that the polarization state of electromagnetic waves and phase shifts can be modulated by exploiting an anisotropic space layer in a polarization F-P filter. Birefringence of the anisotropic space layer provided a sophisticated phase modulation with varied incidence angles over a broad range, resulting in a wide-angle phase shift. This new concept would be useful for designing optical components with isotropic and anisotropic materials.

Optimization of Hot Water Extraction for Enhancing Antioxidative Activity from Auricularia auricula Using Taguchi Approach (Taguchi 법에 의한 흑목이버섯의 항산화활성 증진을 위한 열수추출 최적화)

  • Kim, Hyeon-Min;Hur, Won;Lee, Shin-Young
    • Food Engineering Progress
    • /
    • v.15 no.3
    • /
    • pp.221-229
    • /
    • 2011
  • Optimization study of the hot water extraction for enhancing antioxidative activity from Auricularia auricula was performed by Taguchi approach using orthogonal matrix $L_9(3^4)$ method. The correlation between DPPH radical scavenging activity and the components of samples extracted from different extraction conditions were also analyzed. The correlation coefficient between DPPH radical scavenging activity and melanin content of A. auricula were 0.93, indicating 'good correlation'. The optimum extraction conditions was obtained at the extraction time of 1 hr. temperature of $85^{\circ}C$, solid: water ratio of 1: 40(w/v) and frequency of 2 times. Under these conditions, values of maximum DPPH free radical scavenging activity and melanin contents of A. auricula were $67.21{\pm}2.17$ and $52.94{\pm}2.10 mg/g$, respectively. Melanin content of 1.6 times and DPPH free radical scavenging effect of 130% were enhanced by optimization.

Performance of Time-averaging Channel Estimator for OFDM System of Terrestrial Broadcasting Channel (지상파 방송 채널에서 OFDM 시스템의 시간 평균 채널 추정기의 성능)

  • 문재경;오길남;박재홍;하영호;김수중
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.1
    • /
    • pp.44-53
    • /
    • 1999
  • In this paper, we propose a pilot based time-averaging channel estimation method and analyze error performances for efficient transmission of OFDM(Orthogonal Frequency Division Multiplexing) in multipath fading environment. Frequency domain channel estimations have been used in OFDM systems to compensate signal distortions due to fading on each subcarrier. The frequency domain estimation scheme uses scattered pilot to estimate channel response by simple interpolation. This implies that the estimated channel response includes signal distortions due to the noise. In this paper, we propose time-averaged channel estimation method to remove the distortion by noise. The proposed scheme can effectively remove noise components by taking time-average of the estimated channel response after estimating frequency domain channel. The computer simulations were performed to evaluate the performance of the proposed channel estimator. For the Rician channel, we compared the performance of the proposed method to that of a conventional one using channel estimation by gaussian interpolation when SER(Symbol Error Rate) = $10^{-4}$, and compared to perfect channel estimation case. The proposed method showed differences of 0.07 dB, 0.6 dB compared to perfect channel estimation and improvements of 1.7 dB, 1.9 dB for 16 QAM, 64 QAM respectively compared to conventional method.

  • PDF

Nutrient-derived Dietary Patterns and Risk of Colorectal Cancer: a Factor Analysis in Uruguay

  • Stefani, Eduardo De;Ronco, Alvaro L.;Boffetta, Paolo;Deneo-Pellegrini, Hugo;Correa, Pelayo;Acosta, Gisele;Mendilaharsu, Maria
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.1
    • /
    • pp.231-235
    • /
    • 2012
  • In order to explore the role of nutrients and bioactive related substances in colorectal cancer, we conducted a case-control in Uruguay, which is the country with the highest production of beef in the world. Six hundred and eleven (611) cases afflicted with colorectal cancer and 1,362 controls drawn from the same hospitals in the same time period were analyzed through unconditional multiple logistic regression. This base population was submitted to a principal components factor analysis and three factors were retained. They were labeled as the meat-based, plant-based, and carbohydrates patterns. They were rotated using orthogonal varimax method. The highest risk was positively associated with the meat-based pattern (OR for the highest quartile versus the lowest one 1.63, 95 % CI 1.22-2.18, P value for trend = 0.001), whereas the plant-based pattern was strongly protective (OR 0.60, 95 % CI 0.45-0.81, P value for trend <0.0001. The carbohydrates pattern was only positively associated with colon cancer risk (OR 1.46, 95 % CI 1.02-2.09). The meat-based pattern was rich in saturated fat, animal protein, cholesterol, and phosphorus, nutrients originated in red meat. Since herocyclic amines are formed in the well-done red meat through the action of amino acids and creatine, it is suggestive that this pattern could be an important etiologic agent for colorectal cancer.

A numerical simulation on the effect of hole geometry for film cooling flow (홀 형상이 막 냉각 유동에 미치는 효과에 대한 수치 해석적 연구)

  • Lee, Jeong-Hui;Choe, Yeong-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.7
    • /
    • pp.849-861
    • /
    • 1997
  • In this study, the effect of hole geometry of the cooling system on the flow and temperature field was numerically calculated. The finite volume method was employed to discretize the governing equation based on the non-orthogonal coordinate with non-staggered variable arrangement. The standard k-.epsilon. turbulence model was used and also the predicted results were compared with the experimental data to validate numerical modeling. The predicted results showed good agreement in all cases. To analyze the effect of the discharge coefficient for slots of different length to width, the inlet chamfering and radiusing holes were considered. The discharge coefficient was increased with increment of the chamfering ratio, radiusing ratio and slot length to width and also the effect of radiusing showed better result than chamfering in all cases. In order to analyze the difference between the predicted results with plenum region and without plenum region, the velocity profiles of jet exit region for a various flow conditions were calculated. The normal velocity components of jet exit showed big difference for the low slot length to width and high blowing rate cases. To analyze the flow phenomena injected from a row of inclined holes in a real turbine blade, three dimensional flow and temperature distribution of the region including plenum, hole and cross stream with flow conditions were numerically calculated. The results have shown three-dimensional flow characteristics, such as the development of counter rotating vortices, jetting effect and low momentum region within the hole in addition to counter rotating vortex structure in the cross stream.

A Tuned Liquid Mass Damper(TLMD) for Controlling Bi-directional Responses of a Building Structure (건축구조물의 2방향 진동제어를 위한 동조액체질량감쇠기)

  • Heo, Jae-Sung;Park, Eun-Churn;Lee, Sang-Hyun;Lee, Sung-Kyung;Kim, Hong-Jin;Cho, Bong-Ho;Jo, Ji-Seong;Kim, Dong-Young;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.3
    • /
    • pp.345-355
    • /
    • 2008
  • This paper presents a design of a tuned liquid mass damper(TLMD) for controlling bi-directional response of high-rise building structure subjected to windload. The proposed damper behaves as a tuned mass damper(TMD) of which mass is regarded as the mass of a tuned liquid column damper(TLCD) and the case wall of the TLCD itself in one direction and the TLCD in the other direction. Because the proposed device has coupled design parameter along two orthogonal directions, it is very important to select designing components by optimal fine tuning. In the designing TLMD, for easy maintenance, the rubber-bearing with small springs was applied in TMD direction. In this study, the Songdo New City Tower 1A in Korea, which has been designed and constructed two TLCDs in order to control bi-directional response, was chosen as the model building structure. The results of rotation test proved the effectiveness of bi-directional behavior of TLMD.