• 제목/요약/키워드: orthodontics

검색결과 2,695건 처리시간 0.028초

Accuracy of artificial intelligence-assisted landmark identification in serial lateral cephalograms of Class III patients who underwent orthodontic treatment and two-jaw orthognathic surgery

  • Hong, Mihee;Kim, Inhwan;Cho, Jin-Hyoung;Kang, Kyung-Hwa;Kim, Minji;Kim, Su-Jung;Kim, Yoon-Ji;Sung, Sang-Jin;Kim, Young Ho;Lim, Sung-Hoon;Kim, Namkug;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제52권4호
    • /
    • pp.287-297
    • /
    • 2022
  • Objective: To investigate the pattern of accuracy change in artificial intelligence-assisted landmark identification (LI) using a convolutional neural network (CNN) algorithm in serial lateral cephalograms (Lat-cephs) of Class III (C-III) patients who underwent two-jaw orthognathic surgery. Methods: A total of 3,188 Lat-cephs of C-III patients were allocated into the training and validation sets (3,004 Lat-cephs of 751 patients) and test set (184 Lat-cephs of 46 patients; subdivided into the genioplasty and non-genioplasty groups, n = 23 per group) for LI. Each C-III patient in the test set had four Lat-cephs: initial (T0), pre-surgery (T1, presence of orthodontic brackets [OBs]), post-surgery (T2, presence of OBs and surgical plates and screws [S-PS]), and debonding (T3, presence of S-PS and fixed retainers [FR]). After mean errors of 20 landmarks between human gold standard and the CNN model were calculated, statistical analysis was performed. Results: The total mean error was 1.17 mm without significant difference among the four time-points (T0, 1.20 mm; T1, 1.14 mm; T2, 1.18 mm; T3, 1.15 mm). In comparison of two time-points ([T0, T1] vs. [T2, T3]), ANS, A point, and B point showed an increase in error (p < 0.01, 0.05, 0.01, respectively), while Mx6D and Md6D showeda decrease in error (all p < 0.01). No difference in errors existed at B point, Pogonion, Menton, Md1C, and Md1R between the genioplasty and non-genioplasty groups. Conclusions: The CNN model can be used for LI in serial Lat-cephs despite the presence of OB, S-PS, FR, genioplasty, and bone remodeling.

En-masse retraction with a preformed nickel-titanium and stainless steel archwire assembly and temporary skeletal anchorage devices without posterior bonding

  • Jee, Jeong-Hyun;Ahn, Hyo-Won;Seo, Kyung-Won;Kim, Seong-Hun;Kook, Yoon-Ah;Chung, Kyu-Rhim;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제44권5호
    • /
    • pp.236-245
    • /
    • 2014
  • Objective: To evaluate the therapeutic effects of a preformed assembly of nickel-titanium (NiTi) and stainless steel (SS) archwires (preformed C-wire) combined with temporary skeletal anchorage devices (TSADs) as the sole source of anchorage and to compare these effects with those of a SS version of C-wire (conventional C-wire) for en-masse retraction. Methods: Thirty-one adult female patients with skeletal Class I or II dentoalveolar protrusion, mild-to-moderate anterior crowding (3.0-6.0 mm), and stable Class I posterior occlusion were divided into conventional (n = 15) and preformed (n = 16) C-wire groups. All subjects underwent first premolar extractions and en-masse retraction with preadjusted edgewise anterior brackets, the assigned C-wire, and maxillary C-tubes or C-implants; bonded mesh-tube appliances were used in the mandibular dentition. Differences in pretreatment and post-retraction measurements of skeletal, dental, and soft-tissue cephalometric variables were statistically analyzed. Results: Both groups showed full retraction of the maxillary anterior teeth by controlled tipping and space closure without altered posterior occlusion. However, the preformed C-wire group had a shorter retraction period (by 3.2 months). Furthermore, the maxillary molars in this group showed no significant mesialization, mesial tipping, or extrusion; some mesialization and mesial tipping occurred in the conventional C-wire group. Conclusions: Preformed C-wires combined with maxillary TSADs enable simultaneous leveling and space closure from the beginning of the treatment without maxillary posterior bonding. This allows for faster treatment of dentoalveolar protrusion without unwanted side effects, when compared with conventional C-wire, evidencing its clinical expediency.

Effect of fangchinoline on root resorption during rat orthodontic tooth movement

  • Bao, Xingfu;Hu, Min;Zhang, Yi;Machibya, Ferdinand;Zhang, Ying;Jiang, Huan;Yu, Dongsheng
    • 대한치과교정학회지
    • /
    • 제42권3호
    • /
    • pp.138-143
    • /
    • 2012
  • Objective: To evaluate the short-term effect of fangchinoline, an anti-inflammatory drug widely used in Asia, on root resorption that is associated with orthodontic tooth movement. Methods: Twenty-four Wistar rats were randomly divided into 6 groups. Mesial forces of 0, 50, or 100 g were applied to the maxillary first molar of the rats in each group for 14 days by activating nickel-titanium closed-coil springs. One-half of the rats receiving each of these treatments also received injections of 200 ${\mu}L$ fangchinoline every 2 days. Finally, movement of the maxillary first molars was measured using digitized radiographs. The molars were extracted and the surfaces of the root resorption craters were recorded using a scanning electron microscope. The distance the molars moved and resorption-area ratio was measured, and results were analyzed using 2-way ANOVA tests. Results: There were no statistical differences in the distances the first molars moved under 50 or 100 g force, regardless of treatment with fangchinoline. However, the resorption area ratios were significantly smaller in those rats that were treated with both tension and fangchinoline than in those rats treated by tension alone. Conclusions: Fangchinoline reduced the resorption area ratio in rats and is therefore an important means of alleviating root resorption.

Evaluation of the relationship between upper incisor exposure and cephalometric variables in Korean young adults

  • Han, Sung-Hoon;Lee, Eon-Hwa;Cho, Jin-Hyoung;Chae, Jong-Moon;Kim, Sang-Cheol;Chang, Na-Young;Kang, Kyung-Hwa
    • 대한치과교정학회지
    • /
    • 제43권5호
    • /
    • pp.225-234
    • /
    • 2013
  • Objective: The purpose of this study was to classify Korean young adults into 3 groups on the basis of upper incisor exposure rates (UIERs) and to compare the skeletal, dental, and soft tissue variables. Methods: Samples were obtained from 127 students at the College of Dentistry, Wonkwang University in South Korea. Facial photographs of frontal posed smiles and lateral cephalograms of the subjects were taken. The subjects were divided into 3 groups on the basis of UIERs and 20 measurements were compared among the 3 groups. The correlations between the variables were determined. Results: Male and female subjects showed significant differences in the group distribution. Male subjects showed higher frequencies of low smiles, and female subjects showed higher frequencies of high smiles. The vertical height of the anterior alveolar process of the maxilla directly correlated with the UIER. However, the UIER showed no significant correlation with the vertical height of the anterior basal bone or the inclination of the upper incisor axis. In female subjects, the upper central incisor clinical crown length showed an inverse correlation with the UIER. However, this variable showed no significant correlation with the UIER in male subjects. Conclusions: The UIER was directly correlated with the levator muscle activity of the upper lip and inversely correlated with the upper lip thickness, yet there was no correlation between the UIER and upper lip length at rest.

Comparison between fiber-reinforced polymers and stainless steel orthodontic retainers

  • Lucchese, Alessandra;Manuelli, Maurizio;Ciuffreda, Claudio;Albertini, Paolo;Gherlone, Enrico;Perillo, Letizia
    • 대한치과교정학회지
    • /
    • 제48권2호
    • /
    • pp.107-112
    • /
    • 2018
  • Objective: The aim of this study was to examine the properties of fiber-reinforced composite and stainless steel twisted retainers for orthodontic retention. Methods: Three different span lengths (5.0, 8.0, and 14.0 mm) of fiber-reinforced composite were investigated. The three fiber-reinforced composite retainer groups were subdivided according to the storage condition (dry and wet), resulting in a total of six groups. Each stainless steel and fiber-reinforced composite group was comprised of six specimens. The three-point bending flexural test was conducted using a universal testing machine. ANOVA was used to assess differences in the maximum load and maximum stress according to the span length, material, and storage condition. Post-hoc comparisons were performed if necessary. Results: The maximum stress and maximum load were significantly (p < 0.001) associated with the span length, material, and storage condition. The significant interaction between the material and span length (p < 0.001) indicated the differential effects of the material for each span length on the maximum stress and maximum load, with the difference between materials being the highest for the maximum span length. Conclusions: Our findings suggest that fiber-reinforced composite retainers may be an effective alternative for orthodontic retention in patients with esthetic concerns or allergy to conventional stainless steel wires.