• Title/Summary/Keyword: orthodontics

Search Result 2,701, Processing Time 0.026 seconds

Effect of bite force on orthodontic mini-implants in the molar region: Finite element analysis

  • Lee, Hyeon-Jung;Lee, Kyung-Sook;Kim, Min-Ji;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.43 no.5
    • /
    • pp.218-224
    • /
    • 2013
  • Objective: To examine the effect of bite force on the displacement and stress distribution of orthodontic mini-implants (OMIs) in the molar region according to placement site, insertion angle, and loading direction. Methods: Five finite element models were created using micro-computed tomography (microCT) images of the maxilla and mandible. OMIs were placed at one maxillary and two mandibular positions: between the maxillary second premolar and first molar, between the mandibular second premolar and first molar, and between the mandibular first and second molars. The OMIs were inserted at angles of $45^{\circ}$ and $90^{\circ}$ to the buccal surface of the cortical bone. A bite force of 25 kg was applied to the 10 occlusal contact points of the second premolar, first molar, and second molar. The loading directions were $0^{\circ}$, $5^{\circ}$, and $10^{\circ}$ to the long axis of the tooth. Results: With regard to placement site, the displacement and stress were greatest for the OMI placed between the mandibular first molar and second molar, and smallest for the OMI placed between the maxillary second premolar and first molar. In the mandibular molar region, the angled OMI showed slightly less displacement than the OMI placed at $90^{\circ}$. The maximum Von Mises stress increased with the inclination of the loading direction. Conclusions: These results suggest that placement of OMIs between the second premolar and first molar at $45^{\circ}$ to the cortical bone reduces the effect of bite force on OMIs.

Effect of carbonated water manufactured by a soda carbonator on etched or sealed enamel

  • Ryu, Hyo-kyung;Kim, Yong-do;Heo, Sung-su;Kim, Sang-cheol
    • The korean journal of orthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-56
    • /
    • 2018
  • Objective: The purpose of this study was to determine the effects of carbonated water on etched or sealed enamel according to the carbonation level and the presence of calcium ions. Methods: Carbonated water with different carbonation levels was manufactured by a soda carbonator. Seventy-five premolar teeth were randomly divided into a control group and 4 experimental groups in accordance with the carbonation level and the presence of calcium ions in the test solutions. After specimen preparation of the Unexposed, Etched, and Sealed enamel subgroups, all the specimens were submerged in each test solution for 15 minutes three times a day during 7 days. Microhardness tests on the Unexposed and Etched enamel subgroups were performed with 10 specimens from each group. Scanning electron microscopy (SEM) tests on the Unexposed, Etched, and Sealed enamel subgroups were performed with 5 specimens from each group. Microhardness changes in different groups were statistically compared using paired t-tests, the Wilcoxon signed rank test, and the Kruskal-Wallis test. Results: The microhardness changes were significantly different between the groups (p = 0.000). The microhardness changes in all experimental groups except Group 3 (low-level carbonated water with calcium ions) were significantly greater than those in the Control group. SEM showed that etched areas of the specimen were affected by carbonated water and the magnitude of destruction varied between groups. Adhesive material was partially removed in groups exposed to carbonated water. Conclusions: Carbonated water has negative effects on etched or sealed enamel, resulting in decreased microhardness and removal of the adhesive material.

Accuracy of three-dimensional cephalograms generated using a biplanar imaging system

  • Park, Ha-Yeon;Lee, Jae-Seo;Cho, Jin-Hyoung;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • The korean journal of orthodontics
    • /
    • v.48 no.5
    • /
    • pp.292-303
    • /
    • 2018
  • Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on cone-beam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D $Ceph^{TM}$ program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D $ceph_{biplanar}$), conventional radiography (3D $ceph_{conv}$), and CBCT (3D $ceph_{cbct}$). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland-Altman plotting. Results: There were no statistically significant differences between the 3D $ceph_{biplanar}$ and 3D $ceph_{cbct}$ measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D $ceph_{cbct}$ and 3D $ceph_{conv}$ measurements. However, the values obtained from 3D $ceph_{conv}$ showed larger deviations than those obtained from 3D $ceph_{biplanar}$. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

Comparison study on peference and perception in changed profile between dentists and lay people (측모에 대한 치과의사와 일반인의 인지도와 선호도에 관한 비교 연구)

  • Yim, S.J.;Lee, K.H.;Kook Y.A.;Mo, S.S.;Yang, M.S.;Kang Y.K.
    • The Journal of the Korean dental association
    • /
    • v.44 no.12 s.451
    • /
    • pp.816-829
    • /
    • 2006
  • The purpose of this study was to determine the level of perception and preference between dentists and lay people to altered facial profile. The assessors consisted of 40 dentists and 54 lay people, the survey was performed using questionnaire asking the order of perception and preference. The profiles presented in the questionnaire were based on the profile of one man and one woman, each morphed according to anterior or posterior direction of maxilla and mandible. The results were as follows. 1. In antero-posterior change of man and woman s profile, both dentists and lay people were sensitive to relatively skeletal profile (convex profile) changes than skeletal profile (concave profile) changes. 2. At least dentists needed to be perceived a 2 mm change in convex profile and a 3 mm change in concave profile and lay people needed to be perceived a 2 mm change in convex profile and a 3 mm change in concave profile for profile view. 3. Dentists are more sensitive in perception of man s profile change than lay people, but there is no significant differences between dentists and lay people in sensitivity of detection for woman s profile changes . 4. It seems that there is a general concordance between dentists and lay people in there perception of man s and woman s facial profile. This information might be clinician in comprehensive perception and preference of dentists and lay people to altered facial profile.

  • PDF

Reliability study of 6-axis model surgery simulator for orthognathic surgery (6축 모형수술 시뮬레이터의 정확도에 관한 연구)

  • Jeon, Jae-Ho;Lee, Hyung-Chul;Ji, Hyun-Jin;Jeon, Yeong-Jin;Kim, Yong-Il;Son, Woo-Sung;Park, Soo-Byung;Kim, Sung-Sik;Whang, Dae-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.1
    • /
    • pp.23-27
    • /
    • 2010
  • The purpose of this study was to evaluate the reliability of 6-axis model surgery simulator (6AMSS) for orthognathic surgery. A rectangular parallelepiped plastic block was assembled to model-mounting plate of 6AMSS. Left-right (X), anterior-posterior (Y), up-down (Z) translation and pitching (${\phi}X$), rolling (${\phi}Y$) and yawing (${\phi}Z$) rotation was planned and performed using 6AMSS. The actual translation and rotation were measured with dial gauge and precisional protractor, respectively. Comparison between the planned and actual movements of plastic block for each variable were made using paired t- test. Statistical analysis for X, Y, Z, ${\phi}X$, ${\phi}Y$ and ${\phi}Z$ movement have shown no significant differences between planned and actual movement (P > 0.05). This indicate that model surgery performed with the aid of the 6AMSS is accurate in 3D translation and rotation. The 6AMSS is practically useful for accurate fabrication of surgical splint for orthognathic surgery.

Accuracy of inter-arch measurements performed on digital models generated using two types of intraoral scanners: Ex vivo study

  • Yoo, Jo-Kwang;Kang, Yoon-Koo;Lee, Su-Jung;Kim, Seong-Hun;Moon, Cheol-Hyun
    • The Journal of the Korean dental association
    • /
    • v.58 no.4
    • /
    • pp.194-205
    • /
    • 2020
  • Objective: The purpose of this study was to evaluate the accuracy of the inter-arch relationship of digital models generated using two types of intraoral scanners. Methods: In total, 34 plaster model samples were used. Two corresponding digital models were created using two types of intraoral scanners. A total of 15 variables were measured. The plaster model was directly measured using a digital caliper, while the digital models were measured using a software. The accuracy of the measurements was evaluated using repeated measures analysis of variance and the Friedman test. Results: Among the 15 measurements, 6 measurements[Overjet, Overbite, DZ_11-41 (Distance between the gingival zenith of maxillary right central incisor and mandibular right central incisor), DZ_16-46 (Distance between the gingival zenith of maxillary right first molar and mandibular right first molar), DZ_13-33 (Distance between the gingival zenith of maxillary right canine and mandibular left canine), and DZ_23-43 (Distance between the gingival zenith of maxillary left canine and mandibular right canine)]showed statistically significant differences, with DZ_23-43 showing the largest difference of 0.18 mm. The other measurements showed no statistically significant differences. Conclusions: Regardless of the type of scanner used for preparation, digital models can be used as clinically acceptable alternatives to conventional plaster models.

  • PDF

Departments of Dental Technology An improvement plan of Curriculum - Focus on students who being in college - (치기공과 교육과정의 개선 방안 - 재학생을 중심으로 -)

  • Bae, Bong-Jin;Lee, Hwa-Sik;Park, Myung-Ho
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.49-64
    • /
    • 2007
  • This research collected the curriculum for Dental Technology from a total of 20 schools -3-year colleges and 4-year colleges- all in Korea. And we analyzed the average credits of subjects from students. As a result of this analysis, we get the conclusion below: 1. In a distribution which students answered about each subjects; Seminar, Dental morphology I II, Dental morphology practice I II, and Dental devices & instruments don't have many credits and mostly have a converged tendency in high points, according to the arithmetic mean of the major basis subjects. 2. In an analysis of the correlation which is based on the distinction of sex: Complete denture prosthodontics I II III, Dental orthodontics I II, Dental orthodontics practice I II, and Dental orthodontics & practice III have a meaningful difference. ($\rho$< 0.05 ) 3. In an analysis of the correlation which is based on an age The major basis subjects -Introduction to dental technology, Dental esthetic, and Dental casting procedure-, and the major application subjects -Crown and bridge prosthodontics practice, Complete denture prosthodontics, Dental orthodontics, Dental orthodontics practice, and Operative dentistry laboratory technology- have meaningful difference. ($\rho$< 0.05 ) 4. In a correlation coefficient between subjects; The correlation coefficient of the major application subjects is higher than the major basis subjects. According to the student - t, we found that the level of significance is $\rho$< 0.001, which is meaningful. We feel the lack of a limitation which we didn't survey all students who are major in Department of Dental Technology. And we also feel that we'd better to consider not only students who being in college but also graduated students.

  • PDF

Orthodontic Traction of Impacted Tooth (매복된 치아의 교정적 견인을 통한 치험예)

  • Kim, Kyung-Ho;Choy, Kwang-Chul;Lee, Ji-Yeon;Kang, Chang-Soo
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.991-999
    • /
    • 1998
  • Tooth impaction may lead to malocclusion, root resolution, cyst or aberrant changes in adjacent teeth. Clinical and radiographic examinations are used to locate the impaction, and appropriate treatment plans must be made to relocate the impacted tooth. When surgically exposing the impacted tooth, periodontal considerations to conserve maximum amount of soft and hard tissue are used. Oral hygiene instructions are emphasized to maintain sound periodontal health. Securing enough space for the impacted tooth and proper anchorage is important. Proper use of force and mechanics is crucial to prevent such complications as root resolution. Various patterns of orthodontic traction may be employed as situation permits. Most impaction cases can be managed with orthodontic traction to restore function and esthetics, provided that early detection and proper diagnosis and treatment planning are made.

  • PDF

Relationship of Dental Crowding to Tooth Size and Arch Width (치아 크키와 치열궁 폭경이 치아밀집에 미치는 영향)

  • Hwang, Hyeon-Shik;Kim, Jeong-Tae;Cho, Jin-Hyoung;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.34 no.6 s.107
    • /
    • pp.488-496
    • /
    • 2004
  • The purpose of the present study was to investigate the relationship of dental crowding to tooth size and arch dimension in Korean subjects. Two groups of dental casts with Class I molar relationship, were selected on the basis of crowding. One group, consisting of 82 pairs of study cast (29 males and 53 females), exhibited at least 7 millimeters of crowding in each arch. A second group, consisting of 82 sets of study cast (37 males and 45 females), exhibited normal occlusion with little or no crowding. Mesiodistal tooth diameters, and buccal and lingual dental arch widths were measured and compared between the crowding and normal occlusion groups. Significant differences were observed between the two groups not only in arch widths but also in tooth sizes. The results of the present study suggest that both extraction and expansion can be used as a treatment approach for the crowding cases.

Incisor inclination indicator for anterior torque control during retraction in lingual orthodontic treatment (설측교정치료에 있어서 전치부 후방 견인시 토오크 조절을 위한 incisor inclination indicator)

  • Hong, Ryoon-Ki;Kim, Tae-Gun;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.34 no.6 s.107
    • /
    • pp.544-554
    • /
    • 2004
  • A device called incisor inclination indicator to control the axial inclinations of the incisors in the diagnostic setup is introduced. It is used to control the retraction of the maxillary and mandibular incisors. In this article, we describe the use of the incisor inclination indicator to prescribe adequate torque into the anterior lingual brackets and evaluate the results of treatment in a bimaxillary dentoalveolar protrusion case that underwent orthodontic treatment with the pretorqued anterior lingual brackets. Retraction of the maxillary and mandibular incisors was achieved with careful control of the axial inclination. It is indicated that the use of the incisor inclination indicator is an effective adjunctive laboratory procedure for anterior torque control during retraction in lingual orthodontic treatment.