• Title/Summary/Keyword: orthodontics

Search Result 2,703, Processing Time 0.022 seconds

Assessment of metal artifacts in three-dimensional dental surface models derived by cone-beam computed tomography

  • Nabha, Wael;Hong, Young-Min;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.44 no.5
    • /
    • pp.229-235
    • /
    • 2014
  • Objective: The aim of this study was to assess artifacts induced by metallic restorations in three-dimensional (3D) dental surface models derived by cone-beam computed tomography (CBCT). Methods: Fifteen specimens, each with four extracted human premolars and molars embedded in a plaster block, were scanned by CBCT before and after the cavitated second premolars were restored with dental amalgam. Five consecutive surface models of each specimen were created according to increasing restoration size: no restoration (control) and small occlusal, large occlusal, disto-occlusal, and mesio-occluso-distal restorations. After registering each restored model with the control model, maximum linear discrepancy, area, and intensity of the artifacts were measured and compared. Results: Artifacts developed mostly on the buccal and lingual surfaces. They occurred not only on the second premolar but also on the first premolar and first molar. The parametric values increased significantly with increasing restoration size. Conclusions: Metallic restorations induce considerable artifacts in 3D dental surface models. Artifact reduction should be taken into consideration for a proper diagnosis and treatment planning when using 3D surface model derived by CBCT in dentofacial deformity patients.

Biologic stability of plasma ion-implanted miniscrews

  • Cho, Young-Chae;Cha, Jung-Yul;Hwang, Chung-Ju;Park, Young-Chel;Jung, Han-Sung;Yu, Hyung-Seog
    • The korean journal of orthodontics
    • /
    • v.43 no.3
    • /
    • pp.120-126
    • /
    • 2013
  • Objective: To gain basic information regarding the biologic stability of plasma ion-implanted miniscrews and their potential clinical applications. Methods: Sixteen plasma ion-implanted and 16 sandblasted and acid-etched (SLA) miniscrews were bilaterally inserted in the mandibles of 4 beagles (2 miniscrews of each type per quadrant). Then, 250 - 300 gm of force from Ni-Ti coil springs was applied for 2 different periods: 12 weeks on one side and 3 weeks contralaterally. Thereafter, the animals were sacrificed and mandibular specimens including the miniscrews were collected. The insertion torque and mobility were compared between the groups. The bone-implant contact and bone volume ratio were calculated within 800 mm of the miniscrews and compared between the loading periods. The number of osteoblasts was also quantified. The measurements were expressed as percentages and analyzed by independent t-tests (p < 0.05). Results: No significant differences in any of the analyzed parameters were noted between the groups. Conclusions: The preliminary findings indicate that plasma ion-implanted miniscrews have similar biologic characteristics to SLA miniscrews in terms of insertion torque, mobility, bone-implant contact rate, and bone volume rate.

Clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement: A preliminary study

  • Yun, Dalsun;Choi, Dong-Soon;Jang, Insan;Cha, Bong-Kuen
    • The korean journal of orthodontics
    • /
    • v.48 no.4
    • /
    • pp.262-267
    • /
    • 2018
  • The aim of this study was to test the clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement. The maxillary dentitions of eight patients with fixed orthodontic appliances were scanned using an intraoral scanner at the beginning of treatment (T0), and at 1 month (T1), 2 months (T2), 3 months (T3), and 4 months (T4) after T0. The serial digital models were superimposed on the palatal surface as a reference area, and the linear and angular changes of the central incisors, canines, and first molars were evaluated. The intraclass correlation coefficient and method errors showed that this method was clinically acceptable. Various types of orthodontic tooth movements, including minute movements, could be observed every month. The intraoral scanner and digital superimposition technique enabled the serial evaluation of orthodontic tooth movement without taking serial impressions and/or acquiring radiographs.

A Longitudinal Study on Craniofacial Skeleton Growth Change in Koreans with Normal Occlusion (한국인의 두개안면골 성장변화에 관한 누년적 연구)

  • Park, Kyung-Duk;Sung, Jae-Hyun;Jeong, Dong-Myung;Song, Jae-Kee
    • Journal of the Korean Data and Information Science Society
    • /
    • v.7 no.1
    • /
    • pp.137-144
    • /
    • 1996
  • It is important to investigate the growth aspects of craniofacial skeleton in the orthodontics. The purpose of this study is to find the factors, which have a great influence on the growth aspects of craniofacial skeleton, and to evalute the control values of each factor in order to construct orthodontics diagnostic and planning.

  • PDF

THE USE OF POSTEROANTERIOR CEPHALOGRAM IN ORTHODONTICS (교정에서의 정모 두부 방사선 규격 사진의 이용)

  • Kim, Young Joon;Rhu, Young Kyu
    • The korean journal of orthodontics
    • /
    • v.19 no.2
    • /
    • pp.165-175
    • /
    • 1989
  • In evaluation of some area within the craniofacial complex posteroanterior cephalogram together with lateral cephalogram is used for assessment of the exact existence and posture by grasping 3-dimensional concept. The usages of posteroanterior cephalogram in orthodontics are following; 1. The use during diagnosis and treatment planning 1) Assessment of the area and amount of facial asymmetry. 2) Assessment of therapeutic position for diagnosis and treatment 2. The Assessment of success in orthodontic mechanics If we use posteroanterior cephalogram together with lateral cephalogram adequately and simultaneously we can establish the exact diagnosis and appropriate treatment planning.

  • PDF

Midfacial distraction osteogenesis of Crouzon syndrome with RED(Rigid External Distraction) system (RED(Rigid External Distraction) system을 이용한 Crouzon syndrome환자의 distraction osteogenesis)

  • Lee, Yang-Ku;Choi, Jeong-Ho;Kim, Seok-Hwa;Baek, Seung-Hak;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.32 no.3 s.92
    • /
    • pp.175-183
    • /
    • 2002
  • Crouzon syndrome Is one of the craniofacial syndromes characterized by craniosynostosis, midfacial hypolpasia and ocular proptosis. Distraction osteogenesis is becoming Important technique to treat craniofacial dyplaisa. It has nuy advantages compared with standard orthognathic surgery. Maxillary distraction osteogenesis after Le Fort III osteotomy with the RED system presents successful maxillary protraction to Crouzon syndrome patient with severe maxillary deficiency. It also allows remarkable improvement of facial esthetics and respiratory functions.

Comparison of retention characteristics of Essix and Hawley retainers

  • Demir, Abdullah;Babacan, Hasan;Nalcaci, Ruhi;Topcuoglu, Tolga
    • The korean journal of orthodontics
    • /
    • v.42 no.5
    • /
    • pp.255-262
    • /
    • 2012
  • Objective: We aimed to compare the retention characteristics of Essix and Hawley retainers. Methods: Adolescents undergoing fixed appliance treatment at 2 centers were recruited for this study. Twenty-two patients (16 women and 6 men) wore Essix retainers (Essix group) while 20 (14 women and 6 men) wore Hawley retainers (Hawley group). The mean retention time was 1 year, and the mean follow-up recall time for both groups was 2 years. Two qualified dental examiners evaluated the blind patient data. Maxillary and mandibular dental casts and lateral cephalograms were analyzed at 4 stages: pretreatment (T1), post-treatment (T2), post-retention (T3), and follow-up (T4). Results: The results revealed that Essix appliances were more efficient in retaining the anterior teeth in the mandible during a 1-year retention period. The irregularity index increased in both arches in both groups after a 2-year post-retention period. The mandibular arch lengths increased during treatment and tended to return to their original value after retention in both groups; however, these changes were statistically significant only in the Hawley group. Cephalometric variables did not show any significant differences. Conclusions: The retention characteristics of both Essix and Hawley retainers are similar.

Immediate changes in the mandibular dentition after maxillary molar distalization using headgear

  • Kang, Sung-Ja;Kim, Hyun-Hee;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • The korean journal of orthodontics
    • /
    • v.47 no.2
    • /
    • pp.142-147
    • /
    • 2017
  • The purpose of this study was to investigate immediate changes in the mandibular dentition after maxillary molar distalization using headgear in non-growing patients. Sixteen patients (mean age, $18.9{\pm}2.0$ years) with Class II molar relationship and crowding were included in the present study. To correct the molar relationship, headgear was used for maxillary molar distalization. Cone-beam computed tomography-generated half-cephalograms (CG Cephs) and dental casts were used to evaluate dental changes for each subject before and immediately after molar distalization using headgear. The mean duration that subjects wore the headgear was 6.3 months. CG Cephs showed that the first maxillary molars were distalized $4.2{\pm}1.6\;mm$ with $9.7^{\circ}{\pm}6.1^{\circ}$ of distal angulation. The intercanine, interpremolar, and intermolar widths of the mandible increased after maxillary molar distalization. The present study's results suggest that maxillary molar distalization using headgear induces a spontaneous response in the untreated mandibular dentition of non-growing patients.

New approach of maxillary protraction using modified C-palatal plates in Class III patients

  • Kook, Yoon-Ah;Bayome, Mohamed;Park, Jae Hyun;Kim, Ki Beom;Kim, Seong-Hun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.45 no.4
    • /
    • pp.209-214
    • /
    • 2015
  • Maxillary protraction is the conventional treatment for growing Class III patients with maxillary deficiency, but it has undesirable dental effects. The purpose of this report is to introduce an alternative modality of maxillary protraction in patients with dentoskeletal Class III malocclusion using a modified C-palatal plate connected with elastics to a face mask. This method improved skeletal measurements, corrected overjet, and slightly improved the profile. The patients may require definitive treatment in adolescence or adulthood. The modified C-palatal plate enables nonsurgical maxillary advancement with maximal skeletal effects and minimal dental side effects.

Effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength and bond failure mode of metallic orthodontic brackets

  • Bonetti, Giulio Alessandri;Parenti, Serena Incerti;Ippolito, Daniela Rita;Gatto, Maria Rosaria;Checchi, Luigi
    • The korean journal of orthodontics
    • /
    • v.44 no.1
    • /
    • pp.44-49
    • /
    • 2014
  • Objective: To evaluate the effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength (SBS) and bond failure mode of metallic orthodontic brackets. Methods: Adhesive pre-coated metallic brackets were bonded to 72 extracted human premolars embedded in autopolymerizing acrylic resin. The teeth were randomly divided into 3 groups (n = 24 each) to undergo no treatment (control group) or ultrasonic instrumentation with a scaler-tip angulation of $45^{\circ}$ ($45^{\circ}$-angulation group) or $0^{\circ}$ ($0^{\circ}$-angulation group). SBS was tested in a universal testing machine, and adhesive remnant index (ARI) scores were recorded. The Kruskal-Wallis test and Mann-Whitney U-test were used for statistical analysis. Results: The control group had a significantly higher mean SBS value than the treated groups, which showed no significant differences in their mean SBS values. The ARI scores were not significantly different among the groups. Conclusions: Ultrasonic instrumentation around the bracket base reduces the SBS of metallic orthodontic brackets, emphasizing the need for caution during professional oral hygiene procedures in orthodontic patients. The scaler-tip angulation does not influence the SBS reduction and bond failure mode of such brackets.