• Title/Summary/Keyword: organic pollutants

Search Result 790, Processing Time 0.026 seconds

Removal Methods of Paint Pollutants on the Stone Cultural Heritage using Poultices (습포제를 이용한 석조문화재의 페인트 오염물 제거기법 연구)

  • Lee, Joo-Wan;Ham, Chul-Hee;Kim, Sa-Dug;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.25 no.4
    • /
    • pp.421-430
    • /
    • 2009
  • This research was carried out focusing on the urgent treatment and related studies for paint scribbling on Samjeondobi Monument (Historic Sites No. 101) in 2007. Before the preliminary test, the paint lacquer used on the surface of Samjeondobi Monument was analyzed. The paint lacquer turned out to be the paint lacquer spray composed of $Pb_3O_4$ used for the red pigment in the market. It was proved that the poultice used with the organic solvent was the best way to remove the paint pollutants following the preliminary test for the removal of paint pollutants which was performed with various removal methods by the laser, etc. However, the removing the paint pollutants was found in difficulty in contrast to the preliminary tests because the paint on the spot was hardened so rapidly over time that there was difference from the situation of the laboratory. For that problem, the poultice method with ethylene dichloride of main component from Remover (goods in the market) was the most efficient, therefore the pollutants were removed with the solution of alkyds resin and nitrocellulose and the rest part was removed by the $Laponite^{(R)}$ RD.

  • PDF

Principle and Application of Composting for Soils Contaminated with Hazardous Organic Pollutants (오염토양 정화를 위한 콤포스팅 기술의 원리와 적용에 관한 고찰)

  • Park, Joon-Seok;Lee, Noh-Sup;In, Byung-Hoon;Namkoong, Wan;Hwang, Eui-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.3
    • /
    • pp.77-87
    • /
    • 2001
  • Composting is a cost-effective and environmentally-sound technology to treat soils contaminated with hazardous organic pollutants. Pollutants to be treated are as follows: explosives, phenolic compounds, PAHs, petroleum hydrocarbons, pesticides, and etc. Composting systems are windrow, static pile, and in-vessel. Design and operational parameters of composting are aeration modes, temperature, moisture content, nutrient supplement, amendment added, and etc. Appropriate oxygen concentration of composting for contaminated soils are 5~15%, while some compounds are degraded well at the low $O_2$ concentration of 2~5%. The most diverse microorganisms live in the temperature of $25{\sim}40^{\circ}$. 50~90% of the soil field capacity is the moisture content not to make a problem in composting. Assuming a bacterial chemical equation is $C_{60}H_{87}O_{23}N_{12}P$, theoretical C : N : P from bacterial chemical portion is approximately 20 : 5 : 1. It should be noted that the ratio does not apply to the total organic carbon measured in a waste because not all carbon metabolized by bacteria is synthesized to new cellular material. Initial C/N ratio of 25~40 is optimum. It is more economical to recycle soils or composts than to add commercial microbes.

  • PDF

Characteristics of Inflow Water Quality Variations and Pollutants Transport in Imha Reservoir during a Rainfall Event (강우시 임하호 유입수 수질변동과 오염물질의 공간적 이동 특성)

  • Lee, Heung Soo;Shin, Myung Jong;Yoon, Sung Wan;Chung, Se Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.97-106
    • /
    • 2013
  • The temporal and spatial variations of water quality in a stratified reservoir are fully dependent on the characteristics of inflow loading from its watershed and the transport regimes of pollutants after entering the reservoir. Because of the meteorological and hydrological conditions in Korea, the pollutants loading to reservoirs are mostly occur during rainfall events. Therefore it is important to understand the characteristics of pollutants loading from upstream rivers and their spatial propagation through the stratified reservoir during the rainfall events. The objectives of this study were to characterize the water quality variations in upstream rivers of Imha Reservoir during a rainfall event, and the transport and spatial variations of pollutants in the reservoir through extensive field monitoring and laboratory analysis. The results showed that the event mean concentration (EMC) of SS, BOD, $COD_{Mn}$, T-N, T-P, $PO_4-P$ are 8.6 ~ 362.1, 2.5 ~ 5.1, 1.5 ~ 5.1, 1.1 ~ 1.9, 8.3 ~ 57.1, 5.6 ~ 25.7 times greater than the mean concentrations of these parameters during non-rainfall period. The turbidity and SS data showed good linear correlations, but the relationships between flow and SS showed large variations because of hysteresis effect during rising and falling periods of the flood. The ratio of POC to TOC were 12.6 ~ 14.7% during the non-rainfall periods, but increased up to 28.2 ~ 41.7% during the flood event. The turbid flood flow formed underflow and interflow after entering the reservoir, and delivered a great amount of non-point pollutants such as labile and refractory organic matters and nutrients to the metalimnion layer of reservoir, which is just above the thermocline. Spatially, the lateral variations of most water quality parameters were marginal but the vertical variations were significant.

Comparative Study on Biological Pretreatment Processes for Biologically Stable Drinking Water (생물처리를 이용한 상수원수의 전처리공정에 관한 비교연구)

  • 우달식;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.4
    • /
    • pp.69-76
    • /
    • 1996
  • Biological process have the potential to remove pollutants such as biodegradable organic fraction, $NH_3-N$, ABS, etc. that may be partially removed by conventional water treatment. This study was performed to evaluate four different processes of biological pretreatment as Biological Fluidized Bed(BFB), Biological Filter(BF), Rotating Biological Contactor(RBC) and Honey Comb(HC). In a given condition it proved out that BFB and BF are prospective biological pretreatment processes because they were the most effective on the removal of organic matter and ammonia. Preozonation of raw water for biological processes increased in biodegradable organic fraction about 10-40% with 0.425-0.85 mg $O_3/mg$ DOC.

  • PDF

Analysis of the Discharge Characteristics of Non-point Pollutants from the Interception Facilities according to Rainfall Conditions (강우조건에 따른 차집시설에서의 비점오염물질 유출특성분석)

  • Lin, Zi-Yu;Eun, Beomjin;Heo, Jeong Sook;Choi, I Song;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • This study was carried out to understand the water quality characteristics of the initial stormwater runoff and the origin of soluble pollutants according to various rainfall conditions from a non-point source reducing facility. The water sample from this study was collected among 10 collection facilities in the G-drainage area. Specifically, five of the collection points including #1, #5, #8, #9, and #10 were reported with unknown water inflow even during non-rain conditions. The leakage characteristics of non-point pollutants from the collection facilities were then able to identify accordingly. The water quality characteristics of the stormwater runoff from the collection facilities were strongly affected by the amounts of rainfalls. The average concentrations of EC, BOD, TOC, and TN during non-rain were found to be higher than their concentrations during rain; on the other hand, the average concentrations of DO were found to be lower than its concentrations during rain. In addition, the distribution of organic components existing in the effluent of collection facilities were identified based on the dissolved organic matter analysis. In summary, the stormwater runoff was highly affected by pollutants flowing from the surrounding environment, and the amounts of hard-to-decompose humic substances were greatly increased in the collection facilities due to rain.

Evaluation of pesticide residue analysis of dieldrin in soil using a high resolution gas chromatograph/mass spectrometer (HR-GC/MS)

  • Hwang, Jae-Bok;Park, Tae-Seon
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.4
    • /
    • pp.634-640
    • /
    • 2016
  • The objective of this study was to evaluate the effectiveness of using HR-GC/MS for the rapid screening of dieldrin residues in soils. Persistent organic pollutants (POPs) of organochlorine pesticides such as dieldrin, were analyzed in sedimentary rock and granite rock collected from greenhouses, Niigata, Japan. Dieldrin remains in Japanese farming soils, more than 40 years after their use as insecticides was prohibited. The averages in soil moisture ranged from 2.79% to 7.20% in soils derived from sedimentary rock and from 25.59% to 31.40% in soils derived from granite rock. Mean concentrations of dieldrin residues in sedimentary rock and granite rock were $39.7ng\;g^{-1}$ and $40.51ng\;g^{-1}$, respectively. Dieldrin residue was detected at a slightly higher concentration in granite rock than sedimentary rock samples. There was no consistency between the two soils or between surface and subsurface soils. The coefficients of variation of the two soils were 10.6% and 8.7%, respectively. These results suggest that our high-resolution mass spectrometry detector (HR-GC/MS) is effective at analyzing residual organochlorine pesticides in soil. In order to increase the precision and sensitivity for chemical analysis of POPs, high-resolution gas chromatography coupled with a HR-GC/MS is highly recommended.

Comparison of the Concentration of Ambient Volatile Organic Compounds at an Ulsan Industrial Site in 1997 and 1998 (울산 공단 대기에서 측정한 휘발성 유기화합물의 1997년과 1998년 결과 비교)

  • 나광삼;김용표;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.567-574
    • /
    • 1999
  • Volatile organic Compounds(VOC) were measured at an industrial site in Ulsan in 1997 and 1998. Twenty-four hour integrated ambient air samples were collected in 6 L SUMMA canisters during the periods of June 3 to 8, 1997 and June 12 to 17, 1998. The daily mean concentrations of the total $C_2-C_9$ VOC in 1998 were about one third of those in 1997. This decrease of VOC levels may be attributable to the measures to control the emissions of VOC and the decrease of the plant operation. The decrease in the concentrations of oxygenated hydrocarbons and alkenes, especially, contributed to the decrease of the total VOC concentrations in 1998. Lowever concentrations of alkenes compared to aromatics in 1998 were due to the decrease of ethylene and propylene. In the present study, methanol (12.0 ppb) was the most abundant species, followed by acetone (10.1 ppb), propane (6.0 ppb), and vinyl chloride (5.9 ppb). The total concentrations of hazardous air pollutants (HAPs) in 1998 were reduced compared to those in 1997. However, this decrease is due to the drastic decrease of the concentration of methanol. Except methanol, the concentrations of HAPs have not varied much. It is suspected that the VOC control strategy for the Ulsan industrial area has been successful for reducing the total VOC levels but might not be effective in reducing the concentrations of HAPs.

  • PDF