• 제목/요약/키워드: organic fouling

검색결과 191건 처리시간 0.027초

Mixed matrix membranes for dye removal

  • Evrim Celik-Madenli;Dilara Kesiktas
    • Membrane and Water Treatment
    • /
    • 제14권4호
    • /
    • pp.175-180
    • /
    • 2023
  • Mixed matrix membranes (MMMs) can be a promising alternative for the solution of dye removal from coloured effluents. Polymeric membranes are widely used due to their good film-forming ability, flexibility, separation properties, and cost. However, they have low mechanical, chemical, and thermal resistances. Moreover, the fouling of polymeric membranes is high because of their hydrophobic nature. Hence, there is an increasing interest in organic-inorganic hybrid membranes as a new-generation membrane material. It has been shown that carbon nanotubes have the potential to increase the material properties of polymers with their low density, high strength, hardness, and exceptional aspect ratio. In this work, carbon nanotubes blended MMMs were prepared and methyl orange removal efficiency of them was investigated. Compared to the bare membranes, MMMs showed not only increased hydrophilicity, water content, and pure water flux but also increased methyl orange rejection and flux recovery

하수의 고도처리를 위한 저비용 저에너지의 대체 막을 조합한 생물반응기의 개발 (Advanced Wastewater Treatment using Bioreactor Combined with Alternative Membrane)

  • 김동하
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.25-30
    • /
    • 2005
  • In order to decrease the high costs of membrane process, we have tried to develop two alternatives to membrane; a cartridge type filter and a metal membrane were tested for the high permeation flux with low cost and low energy. This research mainly focused on three points; 1) operation with high permeation flux by using of a cartridge type filter and a metal membrane, 2) removals of the filterable organic materials (FOC) by pretreatments for the membrane fouling control, and 3) advanced wastewater treatment by SMBR process with intermittent aeration and high MLSS. An Intermittently aerated membrane bioreactor using a submerged micro filter (cartridge type) was applied in laboratory scale for the advanced wastewater treatment. To minimize membrane fouling, intermittent aeration was applied inside of the filter with $3.0kg_f/cm^2$. The experiments was conducted for 6 months with three different HRTs (8, 10, 12 hr) and high MLSS of 6,000 and 10,000mg/L. The filtration process could be operated up to 50 days with permeation flux of 500LMH. Regardless of the operating conditions, more than 95% of COD, BOD and SS were removed. Fast and complete nitrification was accomplished, and denitrification was appeared to be the rate-limiting step. More than 75% T-N could be removed due to the endogenous denitrification. T-P removal efficiency was increased to 80% under the condition of MLSS 10,000mg/L.

축전식 탈염공정을 이용한 하수중의 용존염 제거특성 연구 (The removal characteristics of dissolved solid in wastewater during a capacitive deionization process)

  • 신경숙;이태우;차재환;임윤대;박승국;강경석;송의열
    • 상하수도학회지
    • /
    • 제28권2호
    • /
    • pp.151-160
    • /
    • 2014
  • Capacitive deionization(CDI) has many advantages over other desalination technologies due to its low energy consumption, less environmental pollution and relative low fouling potential. The objectives of this study are evaluate the performance of CDI which can be used for dissolved salts removal from sewage. To identify ion selectivity of nitrate and phosphate in multiionic solutions and adsorption/desorption performance related to applied potential, a series of laboratory scale experiments were conducted using a CDI unit cell with activated carbon electrodes. The CDI process was able to achieve more than 75 % TDS and $NO_3{^-}$, $NH_4{^+}$ removals, while phosphate removal was 60.8 % and is inversely related in initial TDS and $HCO_3{^-}$ concentration. In continuous operation, increasing the inner cell pressure and reduction of TDS removal ability were investigated which are caused by inorganic scaling and biofouling. However a relative mild cleaning solution(5 % of citric acid for calcium scaling and 500 mg/L of NaOCl for organic fouling) restored the electrochemical adsorption capacity of the CDI unit to its initial level.

복류수를 이용한 한외여과공정의 장기운전 평가 (Long Term Evaluation of UF Membrane process using River-bed Water)

  • 김충환;임재림;강석형;김수한
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.429-436
    • /
    • 2008
  • Membrane system has been increasingly considered as a safe and cost-effective water treatment process especially in case of small scale water works. This research is a basis of membrane application in water works through a long period test with obtaining operation skills and evaluation of water quality and cost competitiveness. For the research, the UF membrane system was installed in small water treatment plant that uses river-bed water as raw water. The system was consisted of 2 stage membrane and operated in constant flow mode (Flux: 1.5, 1.0, 0.9, 0.6). In each different flux condition, TMP trends were showed better results at lower flux condition. And through the high flux condition test, it is certified that membrane system could deal with breakdown of one stage. Water quality of permeate was satisfied the water quality standards especially turbidity. To know what mainly causes fouling on membrane, the test by membrane with several cleaning agents and EDX analysis have done in lab. Through the tests, ferrous concentration in raw water, backwashing water and membrane surface etc. was high and it causes fouling inside and outside of membrane. So acid cleaning using organic acid such as oxalic acid is necessary in Chemical in Place (CIP). At the economical aspect the electrical cost of membrane system is higher than that of slow sand filtration but labor cost can be reduced by automation. However, the use of labor should be determined considering effectiveness and stability of operation. Because during the operation, there are several breakdown such as electrical shock by lightning, water drop in summer, etc.

정수처리용 응집.한외여과 혼성공정에서 응집 효과에 관한 연구 (Effect of Coagulation in Coagulation/Ultrafiltration Hybrid System in Water Treatment Process)

  • 문성용;이상협;김승현;윤조희
    • 대한환경공학회지
    • /
    • 제27권8호
    • /
    • pp.837-843
    • /
    • 2005
  • 한외여과 공정의 전처리 공정으로 응집을 적용하였으며, 막여과 공정에 미치는 응집공정의 영향을 평가하였다. 예상되는 응집 효과는 수질 개선, 막오염 저감 및 역세척 효율 향상 등이며, 응집 한외여과 막여과 공정을 연속운전을 통해 조사하였다. 이때 적용된 응집제는 황산반토, PACS, 염화제2철이다. 연구 결과 응집을 통해 처리수 수질을 크게 향상 시킬 수 있었으며, 현탁물질 보다는 유기물 제거율에 높은 효과가 있었고, 최대 30.6%의 제거율 향상을 나타내었다. 막오염 저감에 있어서는 세 종류의 응집제 모두 뚜렷한 효과를 관찰할 수 있었으며, 특히 장기운전에 TA어서 PACS가 가장 효과적이었다. 역세척 효율은 철염응집제가 가장 효과적이었으며, 적정 응집제 주입량에 가까울수록 효율이 향상되는 것으로 나타났다.

탄소섬유 한외여과막 및 광촉매 코팅 폴리프로필렌 구의 혼성 수처리: 물 역세척 시 유기물의 영향 (Hybrid Water Treatment of Carbon Fiber Ultrafiltration Membrane and Polypropylene Beads Coated Photocatalyst: Effect of Organic Materials in Water Back-flushing)

  • 박진용;김미향
    • 멤브레인
    • /
    • 제22권6호
    • /
    • pp.415-423
    • /
    • 2012
  • 탄소섬유 한외여과막 및 광촉매 혼성 수처리를 위해 관형 여과막 외부와 원통형 막 모듈 내부 사이 공간에 광촉매를 충전하였다. 광촉매는 PP (polypropylene) 구에 이산화티타늄 분말을 플라즈마 화학증착 공정으로 코팅한 것이다. 휴믹산과 카올린 모사용액을 대상으로 막오염을 최소화하기 위해 10분 주기로 10초 동안 물 역세척을 시행하였다. 기존 결과와 동일하게 휴믹산을 10 mg/L부터 2 mg/L로 변화시킴에 따라, 막오염에 의한 저항 ($R_f$)이 감소하여 2 mg/L에서 최대 총여과부피 ($V_T$)를 얻었다. 탁도와 휴믹산의 처리효율은 각각 97.1%와 74.2% 이상으로 휴믹산 농도의 영향을 받지 않았다. 그러나 기존 결과에서는 휴믹산의 농도가 증가할수록 휴믹산의 처리효율이 다소 증가하는 경향을 나타냈다.

탄소섬유 정밀여과막 및 광촉매 혼성 수처리 공정에서 물 역세척 조건의 영향 (Effect of Water Back-flushing Condition in Hybrid Water Treatment Process of Carbon Fiber Microfiltration Membrane and Photocatalyst)

  • 박진용;조광희
    • 멤브레인
    • /
    • 제22권3호
    • /
    • pp.216-223
    • /
    • 2012
  • 본 연구에서는 정수처리용 탄소섬유 정밀여과막 및 광촉매의 혼성공정에서 물 역세척 주기(FT) 변화의 영향을 알아보고, 알루미나 한외여과막을 사용한 기존의 결과와 비교하였다. 물 역세척 시간(BT)는 10초로 고정한 채, FT를 2~10분으로 변화시키면서, 그 영향을 180분 운전 후 막오염에 의한 저항($R_f$), 투과선속(J)과 총여과부피($V_T$) 측면에서 고찰하였다. FT가 감소할수록, $R_f$는 감소하고 J는 증가하여 알루미나 한외여과막을 사용한 기존의 결과와 동일하였다. 탁도의 처리효율은 99.2% 이상으로 높게 나타났으며, FT 변화에 의한 영향이 보이지 않아 기존의 결과와는 달랐다. 한편, 유기물의 처리효율은 NBF 조건에서 65.6%로 가장 낮았으며 FT가 감소할수록 증가하여 기존의 결과와 역시 다른 현상을 보였다. 이런 차이를 보인 것은 세라믹 분리막의 재질의 차이로 인한 막오염 현상이 다른 기작을 보이기 때문인 것으로 판단된다.

폴리설펀 한외여과막공정에서 오존의 영향 (Effect of Ozonation on Cross-flow Filtration of Polysulfone Ultrafiltration Membrane)

  • 박영규
    • 멤브레인
    • /
    • 제11권4호
    • /
    • pp.179-189
    • /
    • 2001
  • 폴리설폰 한외여과막 분리막공정을 이용하여 투과유속 상에서의 오존의 효과를 고찰하였다. 처음에는 조제한 페놀용액을 이용해 오존의 농도 10-45 mg/l·min을 가한 후에 분리막내에 막오염 제거를 목적으로 시도하였으며 이후에는 오존과 분리막이 혼합된 연속공정에서 폐수처리를 위해 오존에 의한 통일효과를 고찰하기 위해 시도하였다. 전처리 방법으로는 펜톤 산화법을 이용하여 화학응집을 시도하였고 그 결과 폐수내 용존유기물 제거에 효과가 있는 것으로 나타났다. 실험결과 오존을 이용하게 되면 투과유속이 10% 이상 증가한다는 사실이 조제수와 폐수에 공히 같게 나타났으며 오존과 과산화수소를 이용한 고도처리에서도 투과유속증가에 더욱 효과적이었다. 특히 오존을 이용한 처리수에서는 투과압력이 12% 이상 낮아지는 효과가 나타났으며 분리막 공정에 오존처리는 막오염을 거의 제거하기보다는 막오염을 제한적으로 막는 효과를 얻었다.

  • PDF

침지형 막분리 활성오니법에 있어서 생물대사성분의 거동 (Behavior of Soluble Microbial Products in a Submerged Membrane Separation Activated Sludge Process)

  • 차기철;이동열;심진기;이영무;유익근;안승호
    • 대한환경공학회지
    • /
    • 제22권5호
    • /
    • pp.959-970
    • /
    • 2000
  • 본 연구는 실험실 규모의 침지형 막분리 활성오니법을 이용하여 생물 대사 성분이 막투과 유속에 미치는 영향에 대해 고찰하였다. SMP와 분리막의 fouling과의 관계를 살펴보기 위해 연속 실험과 회분 실험으로 나누어 운전하였다. 합성 폐수로는 단일 탄소원으로서 phenol을 사용하였다. 생물 반응조의 체류 시간과 MLSS농도는 각각 12hr과 9.000mgVSS/L로 유지하였다. 연속 장치에 있어서 회분 여과 실험을 통해 SMP농도가 증가할수록 막투과 유속은 감소하였고, cake와 gel층이 형성을 증가시켰다. Cake의 저항은 $2.9{\sim}4.0{\times}10^{10}$으로 측정되어 다른 여과 저항보다 막투과 유속의 감소에 중요한 영향을 나타냈다. 회분 페놀 분해 실험에서 SMP종들 중에 $SMP_{nd}$$SMP_{e}$가 난분해성 고분자 물질로서 막투과 감소에 중요한 역할을 하였다. 또한, SMP농도는 막투과 유속의 감소에 대한 HRT의 증가로서 생물 반응조 내에 축적되었다.

  • PDF

탄소 한외여과막 및 광촉매 코팅 폴리프로필렌 구의 혼성 수처리: 물 역세척 시 유기물 및 광산화, 흡착의 영향 (Hybrid Water Treatment of Carbon Ultrafiltration Membrane and Polypropylene Beads Coated with Photocatalyst: Effect of Organic Materials, Photo-oxidation, and Adsorption in Water Back-flushing)

  • 박진용;정충호
    • 멤브레인
    • /
    • 제22권5호
    • /
    • pp.359-368
    • /
    • 2012
  • 탄소 한외여과막 및 광촉매 혼성 수처리를 위해 관형 여과막 외부와 원통형 막 모듈 내부 사이 공간에 광촉매를 충전하였다. 광촉매는 PP (polypropylene) 구에 이산화티타늄 분말을 플라즈마 화학증착 공정으로 코팅한 것이다. 휴믹산과 카올린 모사용액을 대상으로 막오염을 최소화하기 위해 10분 주기로 10초 동안 물 역세척을 시행하였다. 기존 결과와 동일하게 휴믹산을 10 mg/L부터 2 mg/L로 변화시킴에 따라, 막오염에 의한 저항($R_f$)이 감소하여 2 mg/L에서 최대 총여과부피 ($V_T$)를 얻었다. 탁도와 휴믹산의 처리효율은 각각 98.9%와 88.7% 이상이었다. UF 및 UF + $TiO_2$, UF + $TiO_2$ + UV 공정의 처리 분율 결과, 광촉매 흡착과 광산화에 의해 탁도는 거의 처리되지 않았으나, 광촉매 흡착 및 광산화에 의한 휴믹산 처리 분율은 각각 2.5%, 12.3%이었다. 기존 결과와 비교하면, 분리막의 재질과 기공의 크기에 따라 광촉매 흡착과 광산화에 의한 휴믹산의 처리 분율이 다르게 나타났다. 공정이 단순화될수록 180분 운전 후 막오염 저항($R_{f,180}$)은 증가하였고, 최종 투과선속($J_{180}$)은 소폭 감소하였다.