• 제목/요약/키워드: oral scan

검색결과 282건 처리시간 0.03초

구강점막에 발생한 호지킨림프종의 증례보고 및 문헌고찰 (Hodgkin Lymphoma of the Oral Mucosa : Case report and Literature review)

  • 이은수;;조혜중;;;김영;김옥준
    • 대한구강악안면병리학회지
    • /
    • 제42권6호
    • /
    • pp.175-182
    • /
    • 2018
  • Extranodal intraoral Hodgkin lymphoma is not common. We report the case of a 78-year-old male patient with ulcer of the mandibular oral mucosa that was not cured for about 3 weeks. In biopsy and histopathologic examination, it was found to be extranodal intraoral Hodgkin lymphoma. Early diagnosis of oral lesions led to early detection of lesions of the opposite neck lymph node in an additional PET-CT scan. We report this case and review relevant literature.

하악전돌증에 있어서 전산화단층촬영을 이용한 하악지의 형태학적 평가 (MORPHOLOGICAL EVALUATION OF MANDIBULAR RAMUS IN MANDIBULAR PROGNATHISM BY COMPUTED TOMOGRAPHY)

  • 차두원;장지영;이상한
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권3호
    • /
    • pp.370-375
    • /
    • 2008
  • Sagittal split ramus osteotomy (SSRO) is widely used in treatment of dentofacial deformities. But, many complications can occur including unfavorable fractures during osteotomy. To prevent these complications, it is necessary to understand comprehensively the anatomy of the mandiular ramus. The purpose of this study was to evaluate the morphology of the madibular ramus in manibular prognathism patients by computed tomography comparing with normal control group. The study group consisted of 33 skeletal class III patients (20 males, 13 females) and the control group consisted of the 52 patients without dentofacial deformities (32 males, 20 females). The mean age of study group was 22.0-year old, and that of control group was 37.1-year. For the CT examination, following scan parameters was used: 1mm slice thickness, 0.5 second scan time, 120kV and 100mA/s. The axial scans of the head were made parallel to the mandibular occlusal plane. The anteroposterior length of the ramus, the distance from anterior border of the ramus to lingula, the relative distance from the anterior border of the ramus to lingula compared to the anteroposterior length of the ramus, the thickness of anterior and posterior cortical plate, the thickness of medial cortical plate of the ramus at lingula level, the thickness of cancellous bone of the ramus at lingula level were measured. The skeletal class III mandibular prognathism patients exhibited shorter anteroposterior length of the ramus, thicker anterior and posterior cortical plate, thinner mediolateral cancellous bone thickness. The lingula has a relative stable anteroposterior position in ramus in all groups. There was higher possibility of fusion of medial and lateral cortical plate at lingula level in the mandibular prognathism group. In conclusion, the mandibular prognathism patients have narrow rami with scanty cancellous bone, which means that careful preoperative examination including CT scan can prevent undesirable fractures during osteotomy.

핸드스캐닝 작업 방법에 따라 표준 모델 변형이 작업 정밀도에 미치는 정밀스캔에 관한 연구 (A Study on the Accuracy of Scan by the Standard Model Deformation Depending on the Hand Scanning Method)

  • 신성훈;장성호;송준기;박광식;이희성
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.197-202
    • /
    • 2018
  • 본 연구는 치과분야에서 가장 큰 변화를 가져온 자동화 시스템의 보급화로 CAD/CAM이 사용됨에 따라, 로스트왁스 테크닉 기법 시스템을 대체 하고 있다. 이에 따라 인상재를 이용하여 구강을 채득하는 방법에서 구강스캐너를 활용하여 디지털 데이터로 치과보철물을 제작하고 있다. 그러나 구강스캐너의 스캐닝 방법에 따라 디지털 데이터의 정밀도가 많을 영향을 받고 있는 실정이다. 이에 본 연구의 목적은 구강스캐너 (Intraoral scanner)의 스캔 작업 방법에 따라 나타날 수 있는 왜곡현상 및 데이터 정확도를 평가하고자 한다. 데스탑 3D 모형 스캐너로 임상에서 사용된 석고 모델을 이용하여 표준 스캔 데이터를 만들고 동일한 모델을 사용하여 구강스캐너로 세 가지 다른 방법의(AS그룹, ZS그룹, OS그룹) 스캔 방법으로 구분하여 각 5회씩 그룹별로 스캔 데이터를 만들었고, ZS그룹에서 0.121mm, AS그룹 0.172mm, OS그룹 0.423mm 정확도를 보여 ZS그룹에서 가장 높은 정확도를 보였고, 최대오차 값은 ZS그룹 0.113mm, AS그룹 0.169mm, OS그룹 0.246으로 최대 오차는 ZS그룹이 가장 낮고 OS그룹이 가장 높게 측정되었다. 세 가지의 스캔 방법은 정확도나 재현성에 있어 확실한 차이를 보였으며 임상에서도 역시 의미 있는 결과로 보였다.

구강암 환자에서 경부 임파절 평가에 대한 $^{18}F$-FDG PET(Fluorine 18-Labelled Deoxyglucose Positron Emission Tomography)의 유용성 (DIAGNOSTIC ACCURACY OF $^{18}F$-FDG IN NODAL NEGATIVE ORAL SQUAMOUS CELL CARCINOMA)

  • 최은주;강상훈;김기호;남웅;김형준;차인호
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권6호
    • /
    • pp.597-600
    • /
    • 2007
  • PET is one of the most widely used verification methods for evaluation of metastasis on the lymph nodes of the neck in oral cancer patients. The purpose of this study was to assess the correlation between PET findings and histopathologic findings in patients who had been diagnosed as squamous cell carcinoma and performed neck dissection. Thirty-four necks in 25 patients had been evaluated on pathologic lymph nodes and the data were compared with preoperative PET scan. The sensitivity of PET at the level of the neck was 72.7%, specificity was 60%, and accuracy was 79.2%. Since FDG-PET show high false-positive results, it should be used with other diagnostic tools for evaluation of lymph node metastasis.

COMPARISON OF SHADE CHANGES ACCORDING TO DRY/WET CONDITION OF TEETH USING INTRA-ORAL COLORIMETER

  • Lee, Dong-Hwan;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.314-321
    • /
    • 2005
  • Objectives. The purpose of this study was to compare the shade changes in wet and dry conditions of natural teeth using two different intra-oral colorimeters. Materials and methods. Twenty volunteer subjects have no restorations and fillings in the maxillary central incisors were involved in this clinical study. The color of tooth was measured by two different instruments that were a Shade $Scan^{TM}$ System and a VITA $Easyshade^{(R)}$, Five times consecutive measurements were done for each subject with both instruments. Groups of measurement are an initial wet condition as control, dry in 5 minutes, 15 seconds after re-wetting with saliva, re-wetting after 5minutes and re-wetting after 30 minutes. Using ShadeScan $System^{TM}$, tooth image was captured and converted to the mapping image of Vitapan 3D master. Three main shades were chosen from each subject and calculated the area in Global Lab Image software. Data were analyzed using paired T-Test and Wilcoxon Signed Ranked Test. Using VITA $Easyshade^{(R)}$, color differences($\Delta$E) between measurements were analyzed with one sample T-test. Results. Using ShadeScan $System^{TM}$, there were significant differences between control group and dry(P=.023), dry and re-wetting 15 seconds, 5 minutes, 30 minutes as well(P=.021, P=.017, P=.030) in comparison of primary shade. However, comparing three main shades, there was no significant difference between control and dry(P=.105). Using VITA $Easyshade^{(R)}$, color differences($\Delta$E) between control and dry, dry and re-wetting 30 minutes were statistically different(P=.002, P=.022). Conclusion. Primary shade could be changed in dry and wetting procedure in time, however there was no significant shade changes in overall.

A comparative study to measure the condylar guidance by the radiographic and clinical methods

  • Shreshta, Pragya;Jain, Veena;Bhalla, Ashu;Pruthi, Gunjan
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권3호
    • /
    • pp.153-157
    • /
    • 2012
  • PURPOSE. The study was conducted to compare the radiographic and clinical methods of measuring the horizontal condylar guidance (HCG) values. MATERIALS AND METHODS. The condylar guidance was measured using the radiographic (CT scan) and three clinical methods i.e. the wax protrusive records, Lucia jig record and intraoral central bearing device in 12 patients aged between 20-40 years irrespective of sex. The records were taken and transferred on the semi-adjustable articulator to record the HCG values. The CT scan was taken for 3D reconstruction of the mid facial region. Frankfort horizontal plane (FHP) and a line extending from the superior anterior most point on the glenoid fossa to the most convex point on the apex of articular eminence (AE) was marked on the CT scan. An angle between these two lines was measured on both right and left sides to obtain condylar inclination angle. Three interocclusal protrusive wax and jig records were taken and transferred to the semi adjustable articulator. Three readings were recorded on each side. Similarly the records were taken and transferred to the same articulator using the intra oral central bearing device to record the readings. RESULTS. The statistical analysis showed insignificant differences in the HCG values between the right and left sides [(P=.589 (CT), P=.928 (wax), P=.625 (jig), P=.886 (tracer)]. The clinical methods provided low Pearsons correlation values [(R = 0.423 (wax), R = 0.354 (jig), R = 0.265 (tracer)] for the right as well as the left sides when compared with the CT values. Among the clinical methods, jig and wax method showed strong level of association which is statistically significant while the intra-oral tracer showed weak association with the other two methods. CONCLUSION. The right and left HCG values were almost similar. The CT scan showed higher HCG values than the clinical methods and among the clinical methods, values obtained from all the methods were comparable.

T-scan III® system을 이용한 일부지역 노인의 교합양상과 인지기능의 관련성 (Evaluation of relationship between cognitive function and occlusal status in elderly individuals using the T-scan III® system)

  • 신해은;조민정;최연희;송근배
    • Journal of Korean Academy of Oral Health
    • /
    • 제41권2호
    • /
    • pp.96-101
    • /
    • 2017
  • Objectives: The aim of this study was to investigate the relationship between cognitive function and occlusal status in elderly individuals. Methods: A total of 162 individuals aged 65 years and older, who attended the senior citizen center in Daegu city, were included after consent for participation in the study was obtained. The Korean version of the Mini-Mental State Examination (MMSE-K) was used to evaluate the level of cognitive function. Occlusal status was determined using the T-scan $III^{(R)}$ system. All collected data were analyzed by ${\chi}^2$ test, t-test, one way ANOVA, and linear regression analysis using SPSS version 23.0 for Windows. Results: There was a significant relationship between the cognitive function and the use of dentures. Individuals with posterior occlusal status had higher MMSE-K scores than those with anterior occlusal status. There was a positive correlation between the cognitive function and posterior occlusal force. Conclusions: These results suggest that occlusal status was associated with cognitive function in the elderly individuals. Active national policies to improve occlusal condition in the elderly population are needed.

A comparative study to measure the sagittal condylar inclination using mechanical articulator, virtual articulator and jaw tracking device

  • Liya Ma;Fei Liu;Jiansong Mei;Jiarui Chao;Zhenyu Wang;Jiefei Shen
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권1호
    • /
    • pp.11-21
    • /
    • 2023
  • PURPOSE. To compare the sagittal condylar inclination (SCI) in dentate individuals measured by the different methods with mechanical articulator (MA), virtual articulator (VA), and a jaw tracking device (JTD) system. MATERIALS AND METHODS. A total of 22 healthy dentate participants were enrolled in this study. For MA workflow, the SCI was obtained by a semi-adjustable articulator with protrusive interocclusal records. The SCI was also set on a VA by aligning intraoral scan (IOS) with cone beam computed tomography (CBCT) and facial scan (FS), respectively. These virtual workflows were conducted in a dental design software, namely VAIOS-CBCT and VAIOS-FS. Meanwhile, a JTD system was also utilized to perform the measurement. Intraclass correlation was used to assess the repeatability within workflows. The bilateral SCI values were compared by Wilcoxon matched-pairs signed rank test for each workflow, and Kruskal-Wallis test and post hoc p-value Bonferroni correction were used to compare the differences among four workflows. The agreement of VAIOS-CBCT, VAIOS-FS, and JTD compared with MA was evaluated by Bland-Altman analysis. RESULTS. Intraclass correlation of the SCI revealed a high degree of repeatability for each workflow. There were no significant differences between the left and right sides (P > .05), except for VAIOS-CBCT (P = .028). Significant differences were not found between MA and VAIOS-FS (P > .05). Bland-Altman plots indicated VAIOS-CBCT, VAIOS-FS, and JTD were considered to substitute MA with high 95% limits of agreement. CONCLUSION. The workflow of VAIOS-FS provided an alternative approach to measure the SCI compared with MA.

지연성 운동이상증 환자에서 functionally generated path 술식과 이중스캔법을 이용한 고정성 보철물 제작: 증례 보고 (Fabrication of fixed prosthesis by employing functionally generated path technique and dual scan technique in a tardive dyskinesia patient: a case report)

  • 실파;이두형
    • 대한치과보철학회지
    • /
    • 제61권3호
    • /
    • pp.227-233
    • /
    • 2023
  • 지연성 운동이상증은 도파민 수용체 차단 약물의 장기간 사용으로 인해 발생하는 비자발적 신경학적 운동 장애로 불수의적인 하악의 움직임과 이갈이를 초래하여 과도한 하중이 치아 및 보철물에 위해를 가할 수 있다. 지연성 운동이상증 병력이 있는 40대 남성이 상악 전치부 상실로 인한 보철치료를 위해 내원하였다. #13, 15, 23의 지대치 형성 후 실리콘으로 인상을 채득하고 레진 블록을 밀링하여 임시 보철물을 제작하였다. 시적 과정에서 임시 보철물의 교합면 1/3을 제거하고 교합면에 자가중합 아크릴 레진을 도포하여 환자의 구강에 장착하였다. 레진이 경화되는 동안 하악의 불수의적 움직임으로 대합치에 의한 functionally generated path (FGP)가 레진 표면에서 기록되었다. 수정된 임시 보철물을 제거하여 구내 스캐너로 스캔 후 이중 스캔 방법을 사용하여 임시 보철물의 디자인을 수정하여 최종 보철물을 설계하였다. 최종 보철물은 단일구조 지르코니아로 제작하였다. 본 증례는 FGP 기술과 이중 스캔 방법 이 지연성 운동이상증 환자에서 조화로운 교합을 갖는 고정성 보철물의 제작하는 데 도움이 될 수 있음을 보여준다.

타액선 질환의 조영촬영법과 방사성동위원소 스캔법을 이용한 임상적 연구 (Sialography and Salivary Scan Study of Salivary Diseases)

  • 박윤경;이상래;황의환
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.175-189
    • /
    • 1999
  • The purpose of this study was to established the characteristic radiographic features in salivary gland diseases by means of sialography and scintigraphy. Sialograms and scintigrams with diseases of salivary gland were examined. In this group were 5 salivary stones, 14 sialadenitis, 17 Sjogren's syndromes and 8 benign tumors. The obtained results were as follows; 1. In the configuration of the shape of main duct, those revealed that modified curvilinear and curvilinear types were predominant in Sjogren's syndromes but reverse sigmoid and angular types were in sialolithiasis and sialadenitis combined with sialodochitis. 2. In the configuration of the course of main duct, those revealed that smooth types were predominant in sialadenitis and irregular types were predominant in Sjogren's syndromes and benign tumors and irregular types were seen in all salivary stones and sialadenitis combined with sialodochitis, 3. In the type of intraglandular pattern, those revealed that destructive changes of salivary duct system and parenchyma were severe in sialadenitis and salivary stones and predominantly severe in Sjogren's syndromes. 4. The function of salivary gland was decreased severely in Sjogren's syndrome. and also decrease in salivary stone and sialadenitis. In benign tumor, the uptake of radioisotope was not seen in lesion and the function of salivary gland decreased in its remaining normal parenchyma.

  • PDF