• Title/Summary/Keyword: oral implant

Search Result 1,709, Processing Time 0.081 seconds

Factors associated with the survival and marginal bone loss of dental implants: a 5-year retrospective study (임플란트의 생존과 변연골 소실에 영향을 미치는 인자들)

  • Song, Eul-Rak;Lee, Jae-Kwan;Um, Heung-Sik;Park, Se-Hwan;Chang, Beom-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.280-292
    • /
    • 2016
  • Purpose: The purpose of this study was to compare the long-term survival rate and peri-implant marginal bone loss related to multiple risk factors including the clinician's experience. Materials and Methods: Four hundred twenty implants in 146 patients, who had involved a supportive periodontal therapy program every 3 to 6 months and had follow up data for at least 5 years, were selected as the study group. Peri-implant marginal bone loss, data of demographic, implant and surgical characteristics were collected from peri-apical radiographs and chart review. Implant survival was regarded as the remaining with radiographic marginal bone level in excess of 50% of the fixture length for any reason. Results: The cumulative survival rate after 5 years of loading was 94.9%. In binary logistic regression analysis, smoking status (P = 0.033) and presence of spontaneous cover screw exposure (P < 0.001) were significantly related to 5-year survival of implants. In stepwise multiple regression analysis, smoking status (P < 0.001), type of abutment connection (P < 0.001) and implant surface (P = 0.033) were significantly related to peri-implant marginal bone level. And the year of resident was not statistically related to 5-year implant survival in simple logistic regression analysis (P = 0.171). Conclusion: Smoking status, spontaneous cover screw exposure, type of abutment connection and implant surface might influence the implant success. There was no significant correlation between the year of resident and implant failure.

The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography

  • Kang, Se-Ryong;Bok, Sung-Chul;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.116-127
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. Methods: We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. Results: SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (P<0.01) while SPF demonstrated significant negative correlations with other microstructural parameters (Tb.Sp, Tb.Pf, and SMI) using micro-CT and CBCT (P<0.01). Conclusions: There was an increase in implant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses.

FINITE ELEMENT ANALYSIS OF CYLINDER TYPE IMPLANT PLACED INTO REGENERATED BONE WITH TYPE IV BONE QUALITY (IV형의 골질로 재생된 골내에 식립된 원통형 임플란트의 유한요소법적 연구)

  • Kim, Byung-Ock;Hong, Kug-Sun;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.331-338
    • /
    • 2004
  • Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.

Soft tissue consideration in oral rehabilitation using implant in a patient after oral tumor resection (구강종양 골절제 환자의 임플란트 수복 시 연조직에 대한 고려사항)

  • Lee, Young-Hoon;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.458-466
    • /
    • 2017
  • After the resection of oral tumor, defected maxillofacial structure caused functional difficulties including phonetics, mastication and esthetic aspects. In this cases, implant retained prosthesis can contribute to the functional enhancement. Regardless of the success rate in grafted bone, however, the soft tissue usually had a shape which was susceptible to inflammation. Moreover, infected graft bone presented rapid destruction. For success of the prosthetic treatment, adequate soft tissue treatment and frequent recall check are the essential factors to the successful implant prognosis.

Vertical distraction osteogenesis of a reconstructed mandible with a free vascularized fibula flap: a report of two cases

  • Saito, Naoaki;Funayama, Akinori;Arai, Yoshiaki;Suda, Daisuke;Takata, Yoshiyuki;Kobayashi, Tadaharu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.32.1-32.8
    • /
    • 2018
  • Background: The free vascularized fibula flap presents many advantages such as sufficient length of the bony segment, good vascularization, better quality of the bone, and a long vascular pedicle, but it is also associated with some disadvantages with regard to prosthetic rehabilitation because of its limited height. Improvement in bone height is necessary for ideal dental implant treatment of reconstructed mandibles. Case presentation: For two squamous cell carcinoma patients, mandibular bone reconstruction was performed secondarily with the peroneal flap after tumor resection. Since the bone height was insufficient at the time of implant treatment, occlusion reconstruction by dental implant was performed after vertical distraction osteogenesis. Conclusions: Vertical distraction osteogenesis is a suitable treatment option for alveolar ridge deficiency resulting from fibula transplantation for mandibular reconstruction following tumor surgery.

The relationships between panoramic indices and dental implant failure (파노라마방사선사진 지수와 임플란트 실패와의 관계에 관한 연구)

  • Cho Hyun-Jung;Yi Won-Jin;Heo Min-Suk;An Chang-Hyeon;Lee Jin-Koo;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.25-30
    • /
    • 2004
  • Purpose: Several panoramic indices have been suggested to assess bone quality from the morphology and width of mandibular cortex on panoramic radiography. The purpose of this study was to compare dental implant failure group with control group in panoramic mandibular index (PMI), mandibular cortical index (MCI), and gonion index (GI) and to determine the effect of these panoramic indices on dental implant failure. Materials and Methods: A case-control study was designed. Test group (n=42) consisted of the patients who had their implants extracted because of peri-implantitis. Control group (n=139) consisted of the patients who retained their implants over one year without any pathologic changes and had been followed up periodically. They had dental implants installed in their mandibles without bone augmentation surgery from 1991 to 2001. The following measures were collected for each patients: 1) PMI, MCI, and GI were measured twice at one-week interval on preoperative panoramic views; and 2) age, sex, implant length, implant type, installed location, occluding dentition state, and complication were investigated from the chart record. Results: The PMI showed moderate level of repeatability. The intra-observer agreement of MCI and GI were good. There was statistically significant difference in PMI between two groups. There were significant different patterns of distribution of MCI and GI between two groups. Among the panoramic indices, PMI and MCI showed significant correlation with dental implant failure. Conclusion: Panoramic indices can be used as reference data in estimating bone quality of edentulous patients who are to have implants installed in their mandibles.

  • PDF

Comparative Study on Osseointegration of Calcium Metaphosphate (CMP) Coated Implant to RBM Implant in the Femur of Rabbits (가토의 대퇴부에 Calcium Metaphosphate로 코팅된 임플란트 매식후 골유착에 관한 비교 연구)

  • Kang, Young-Joo;Kim, Ki-Hyun;Lee, Jae-Yeol;Lee, Ju-Min;Ahn, Sang-Wook;Song, Jin-Woo;Jung, Eu-Gene;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.511-520
    • /
    • 2010
  • Purpose: This study was conducted in order to compare the efficacy of osseointegration of three different calcium metaphosphate (CMP) coated implants in the rabbit's femur. Materials and Methods: Twenty four rabbits and three different type of CMP coated implants and RBM implants were used in this study. The animals were divided into 4 groups on the basis of implant surface characteristics. Two implants were installed into the condyle of femur of each rabbits. The animals were sacrificed at 2 and 4 weeks after installation. The undecalcified specimens were prepared for histological, radiological examination and histomorphometric analysis of implant-bone contact ratios (BIC) and bone area ratio (BA). Results: Two implants were failed to osseointegrate and implant success rate was 95.2%. There were not any significant inflammatory response in all groups. Fluorescent image at 4 weeks shows that remodeling is slower in RBM group than CMP group. CMP III showed more active remodeling than CMP I, II. In histomorphologic analysis, BIC ratio at 2 weeks was lower than 4 weeks. Conclusion: The results suggest that the ratios of CMP coated implants were higher than that of RBM control group but there is no significantly difference between RBM group and CMP group. In conclusion, CMP coated implant had more clinical availability than RBM implants.

Evaluation of Effect of Silvernanoparticle Treated Implant on Bone Formation (은나노 처리된 임플란트의 골조직 형성에 미치는 효과 평가)

  • Kim, Sin-Guen;Yoon, Youn-Jin;Lee, Young-Man;Lee, Tae-Sun;Choi, Dong-Won;Song, Yun-Jung;Park, Jun-Woo;Choi, Dong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.4
    • /
    • pp.233-238
    • /
    • 2012
  • Purpose: To evaluate the effect of silvernanopartilce treated implants on the bone formation and osseointegration. Methods: Silvernanoparticle was produced using an anodic oxidation method. The size of silvernanoparticle ranged from 3.5 nm to 5.9 nm. To check the effect of the capability of osseointegration of silvernanoparticle coated Implant, 32 implants (16 piece of Implant treated with nanoparticle, and 16 piece of Implant was not treated for control) were placed at both the tibia of 8 New Zealand white rabbits. After 4 weeks, 4 rabbits were sacrificed and the removal torque was measured for comparison of the osseointagration ability. Further, 4 rabbits were sacrificed and sliced samples were made. H&E stain was done for microscopic finding. Results: The removal torque of the experimental group was $102.37{\pm}30.54$ N/cm, and the control group was $73.30{\pm}19.97$ N/cm. It was statistically significant (P<0.001). Microscopic finding also shows extinguish results in silvernanoparticle treated implants. Bone formation rate of the experimental group was 43.94% and the control group was 7.58%. It was observed to be statistically significant (P=0.017). Bone to implant contact rate of the experimental group was 58.09%, and the control group was 19.43%. It was found with statistical significance (P<0.001). Conclusion: The silvernanopartilce treated implant shows a better capability of bone regeneration and osseointegration than the non-treated one. Technology to produce smaller particles would make silver more useful and safer.

Bone density around the fixture after function of implant molar prosthesis using CBCT (임플란트 보철 기능후 고정체 주변 콘빔CT 골밀도 평가)

  • Jung, Jae-Hyun;Hwang, In-Taik;Jung, Byung-Hyun;Kim, Jae-Duk;Kang, Dong-Wan
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose : The purpose of this study was to examine the significance of increased bone density according to whether bone grafts were applied using demographic data with Cone Beam Computed Tomography (CBCT) and to compare the bone densities between before and after implant prosthesis using the Hounsfield index. Materials and Methods : Thirty-six randomly selected computed tomography (CT) scans were used for the analysis. The same sites were evaluated digitally using the Hounsfield scale with V-Implant $2.0^{TM}$, and the results were compared with maxillary posterior bone graft. Statistical data analysis was carried out to determine the correlation between the recorded Hounsfield unit (HU) of the bone graft and implant prosthesis using a Mann-Whitney U test and Wilcoxon Matched-pairs test. Results : The bone grafted maxillary posterior teeth showed an increase in the mean values from-157 HU to 387 HU, whereas non-grafted maxillary posterior teeth showed an increase from 62 HU to 342 HU. After implantation, the grafted and non-grafted groups showed significantly higher bone density than before implantation. However, the grafted group showed significantly more changes than the non-grafted group. Conclusion : Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density (Hounsfield scale) and bone grafts in the maxillary molar area.

Retrospective Clinical Study on the Survival Rate and the Evaluation of Marginal Bone Resorption on SNUCONE AF+II® Implants

  • Kim, Panjun;Jung, Myungjin;Jeong, Jihye;Choi, Sungyu;Hur, Sunghwi;Lee, Seulki
    • Journal of Korean Dental Science
    • /
    • v.13 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • Purpose: This study analyzes the clinical results of SNUCONE AF+II® (SNUCONE Implant) implants placed in the edentulous region to determine the implant survival rate and the marginal bone healing pattern in the healing process. Materials and Methods: Two hundred forty implants placed in 131 patients with SNUCONE AF+II® implant system from January 1, 2014 to December 31, 2014 at Cheongju Hankook General Hospital were followed up for 5 years. Result: We evaluated 240 SNUCONE AF+II® implants of 131 patients from January 1, 2014 to December 31, 2014 at Cheongju Hankook General Hospital, and the results are as following: 1) Three implants were failed out of 240 implants of 131 patients and the survival rate was 98.75%. 2) The marginal bone resorption was 0.95±1.84 mm for 4 years after prosthesis placement, showing favorable result. Conclusion: Although long-term cumulative evaluations and studies should be performed in the future, SNUCONE AF+II® implants show high cumulative survival and low marginal bone resorption according to the results of this study, which believed to give outstanding result in various dental implant procedure.