• 제목/요약/키워드: oral imaging system

검색결과 154건 처리시간 0.022초

Accuracy of various imaging methods for detecting misfit at the tooth-restoration interface in posterior teeth

  • Francio, Luciano Andrei;Silva, Fernanda Evangelista;Valerio, Claudia Scigliano;Cardoso, Claudia Assuncao e Alves;Jansen, Wellington Correa;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.87-96
    • /
    • 2018
  • Purpose: The present study aimed to evaluate which of the following imaging methods best assessed misfit at the tooth-restoration interface: (1) bitewing radiographs, both conventional and digital, performed using a photostimulable phosphor plate (PSP) and a charge-coupled device (CCD) system; (2) panoramic radiographs, both conventional and digital; and (3) cone-beam computed tomography (CBCT). Materials and Methods: Forty healthy human molars with class I cavities were selected and divided into 4 groups according to the restoration that was applied: composite resin, composite resin with liner material to simulate misfit, dental amalgam, and dental amalgam with liner material to simulate misfit. Radiography and tomography were performed using the various imaging methods, and the resulting images were analyzed by 2 calibrated radiologists. The true presence or absence of misfit corresponding to an area of radiolucency in regions subjacent to the esthetic and metal restorations was validated with microscopy. The data were analyzed using a receiver operating characteristic (ROC) curve, and the scores were compared using the Cohen kappa coefficient. Results: For bitewing images, the digital systems (CCD and PSP) showed a higher area under the ROC curve (AUROC) for the evaluation of resin restorations, while the conventional images exhibited a larger AUROC for the evaluation of amalgam restorations. Conventional and digital panoramic radiographs did not yield good results for the evaluation of resin and amalgam restorations (P<.05). CBCT images exhibited good results for resin restorations(P>.05), but showed no discriminatory ability for amalgam restorations(P<.05). Conclusion: Bitewing radiographs (conventional or digital) should be the method of choice when assessing dental restoration misfit.

Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

  • Lee Ji-Un;Kwon Ki-Jeong;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • 제34권4호
    • /
    • pp.185-190
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Materials and Methods: Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. Results: The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities (P<0.05). The kappa value of inter-observer agreement was 0.42 (range: 0.28-0.60) and intra-observer agreement was 0.57 (range: 0.44-0.75). Conclusion : There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  • PDF

Linear accuracy of cone-beam computed tomography and a 3-dimensional facial scanning system: An anthropomorphic phantom study

  • Oh, Song Hee;Kang, Ju Hee;Seo, Yu-Kyeong;Lee, Sae Rom;Choi, Hwa-Young;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.111-119
    • /
    • 2018
  • Purpose: This study was conducted to evaluate the accuracy of linear measurements of 3-dimensional (3D) images generated by cone-beam computed tomography (CBCT) and facial scanning systems, and to assess the effect of scanning parameters, such as CBCT exposure settings, on image quality. Materials and Methods: CBCT and facial scanning images of an anthropomorphic phantom showing 13 soft-tissue anatomical landmarks were used in the study. The distances between the anatomical landmarks on the phantom were measured to obtain a reference for evaluating the accuracy of the 3D facial soft-tissue images. The distances between the 3D image landmarks were measured using a 3D distance measurement tool. The effect of scanning parameters on CBCT image quality was evaluated by visually comparing images acquired under different exposure conditions, but at a constant threshold. Results: Comparison of the repeated direct phantom and image-based measurements revealed good reproducibility. There were no significant differences between the direct phantom and image-based measurements of the CBCT surface volume-rendered images. Five of the 15 measurements of the 3D facial scans were found to be significantly different from their corresponding direct phantom measurements(P<.05). The quality of the CBCT surface volume-rendered images acquired at a constant threshold varied across different exposure conditions. Conclusion: These results proved that existing 3D imaging techniques were satisfactorily accurate for clinical applications, and that optimizing the variables that affected image quality, such as the exposure parameters, was critical for image acquisition.

Assessment of the role of cone beam computed sialography in diagnosing salivary gland lesions

  • Abdel-Wahed, Nagla'a;Amer, Maha E.;Abo-Taleb, Noha Saleh Mahmoud
    • Imaging Science in Dentistry
    • /
    • 제43권1호
    • /
    • pp.17-23
    • /
    • 2013
  • Purpose: The purpose of this study was to assess cone-beam computed (CBCT) sialography imaging in the detection of different changes associated with lesions of salivary glands. Materials and Methods: This study consisted of 8 cases with signs and symptoms from salivary gland lesions. Conventional sialography using digital panoramic and lateral oblique radiographs and CBCT sialography were performed for each subject. The radiographs were evaluated by 3 radiologists independently of each other. The results were compared between conventional sialography and CBCT sialography in the evaluation of various lesions associated with the salivary glands. Results: There was an agreement between the radiologists in interpreting the lesions that affected salivary glands with both techniques. The detection of the presence of stones or filling defects, stenosis, ductal evagination, dilatation, and space occupying lesions was 83% for conventional sialography compared with CBCT sialography. CBCT sialography was superior to conventional sialography in revealing stones, stenosis, and strictures, especially in the second and third order branches. Conclusion: It would be advisable to perform CBCT sialography in cases of obstructive salivary gland diseases for better demonstration of the ductal system of the gland.

성인의 악하부에 발생한 낭성 림프관종 (Cystic lymphangioma in the submandibular triangle in the adult)

  • 김은경;한원정;김상준
    • Imaging Science in Dentistry
    • /
    • 제31권3호
    • /
    • pp.175-179
    • /
    • 2001
  • Cystic lymphangioma is an uncommon benign developmental tumor of the lymphatic system, seen rarely in adults. A 23-year-old man visited DKUDH complaining of the painless swelling in the right submandibular area. It was reported that swelling had increased since 5 months ago. Clinically, fltriangle uctuant and mobile mass was palpated at the right submandibular area. CT scan showed a large, well-defined, homogenous low density mass, measuring 5.0 × 2.5 × 4.0 cm. T1W MRI scan demonstrated a large, multiseptated homogenous low signal mass with septum and rim enhancement. Proton-density and T2W MRI scan showed mass of high signal intensity. MRI scan was able to delineate better the enhanced multi septation and extent of the lesion. Histopathologically, a lobulated cystic mass lined by a layer of flattened endothelium was observed.

  • PDF

Digital Imaging Fiber-Optic Trans-Illumination을 이용한 초기우식의 탐지 (EARLY CARIES DETECTION WITH DIGITAL IMAGING FIBER-OPTIC TRANS-ILLUMINATION)

  • 이준석;김종수;유승훈
    • 대한장애인치과학회지
    • /
    • 제3권2호
    • /
    • pp.87-90
    • /
    • 2007
  • $DIFOTI^{(R)}$ 가시광선 파장을 이용하여 방사선 노출 없이도 실시간으로 교합면, 인접면, 평활면 우식, 재발성 우식 및 치아 파절이나 불소증 등을 효과적으로 진단할 수 있는 영상 장비이다. 시진 및 방사선 사진에 비해 치아 우식 탐지에 있어서 민감도가 매우 높은 것으로 나타나고 있으며, 이를 통해 치아의 탈회를 조기 진단하여 보다 보존적인 치료가 가능하리라 사료된다.

  • PDF

Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans

  • Shokri, Abbas;Ramezani, Leila;Bidgoli, Mohsen;Akbarzadeh, Mahdi;Ghazikhanlu-Sani, Karim;Fallahi-Sichani, Hamed
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.31-39
    • /
    • 2018
  • Purpose: This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from cone-beam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods: A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values(MGVs) of each cylinder were calculated in each imaging protocol. Results: In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes(P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion: The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

Fast temporal detection of intracellular hydrogen peroxide by HyPer

  • Yang, Yu-Mi;Lee, Sung Jun;Shin, Dong Min
    • International Journal of Oral Biology
    • /
    • 제38권4호
    • /
    • pp.169-173
    • /
    • 2013
  • HyPer is the genetically encoded biosensor of intracellular hydrogen peroxide ($H_2O_2$), the most stable of the reactive oxygen species (ROS) generated by living cells. HyPer has a high sensitivity and specificity for detecting intracellular $H_2O_2$ by confocal laser microscopy. However, it was not known whether high speed ratiometric imaging of $H_2O_2$ by HyPer is possible. We thus investigated the sensitivity of HyPer in detecting changes to the intracellular $H_2O_2$ levels in HEK293 and PC12 cells using a microfluorometer imaging system. Increase in the HyPer ratio were clearly evident on stimulations of more than $100{\mu}M$ $H_2O_2$ and fast changes in the HyPer ratio were observed on ratiometric fluorescent images after $H_2O_2$ treatment. These results suggest that HyPer is a potent biosensor of the fast temporal production of intracellular $H_2O_2$.

Radiographic evaluation of the maxillary sinus prior to dental implant therapy: A comparison between two-dimensional and three-dimensional radiographic imaging

  • Tadinada, Aditya;Fung, Karen;Thacker, Sejal;Mahdian, Mina;Jadhav, Aniket;Schincaglia, Gian Pietro
    • Imaging Science in Dentistry
    • /
    • 제45권3호
    • /
    • pp.169-174
    • /
    • 2015
  • Purpose: This study was performed to evaluate the diagnostic efficacy of panoramic radiography and cone-beam computed tomography (CBCT) in detecting sinus pathology. Materials and Methods: This study was based on a retrospective evaluation of patients who had undergone both a panoramic radiograph and a CBCT exam. A total of 100 maxillary sinuses were evaluated. Four examiners with various levels of expertise evaluated the images using a five-point scoring system. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic efficacy of the two modalities. The image analysis was repeated twice, with at least two weeks between the evaluation sessions. Interobserver reliability was assessed using Cronbach's alpha, and intraobserver reliability was assessed using Cohen's kappa. Results: Maxillary sinus pathology was detected in 72% of the patients. High interobserver and intraobserver reliability were observed for both imaging modalities and among the four examiners. Statistical analyses using ROC curves demonstrated that the CBCT images had a larger area under the curve (0.940) than the panoramic radiographs (0.579). Conclusion: Three-dimensional evaluation of the sinus with CBCT was significantly more reliable in detecting pathology than panoramic imaging.

Magnetic resonance imaging study of incidental findings in the paranasal sinuses and ostiomeatal complex

  • Yousefi, Faezeh;Mollabashi, Mina;Shokri, Abbas;Tavakoli, Emad;Farhadian, Maryam;Tavakoli, Ali
    • Imaging Science in Dentistry
    • /
    • 제52권1호
    • /
    • pp.11-18
    • /
    • 2022
  • Purpose: This study aimed to assess incidental abnormal findings in the paranasal sinuses and anatomical variations of the ostiomeatal complex (OMC) on magnetic resonance imaging (MRI) scans. Materials and Methods: MRI scans of 616 patients (mean age, 44.0±19.4 years) were evaluated. Prior to obtaining the MRI scans, a checklist of patients' clinical symptoms was filled out after obtaining their consent. The Lund-Mackay classification was used to assess the paranasal sinuses and OMC. The prevalence of abnormal findings and their associations with patients' age, sex, and subjective symptoms were analyzed by the chi-square test, independent-sample t-test, and analysis of variance. The level of significance was set at 0.05. Results: Abnormal findings in the paranasal sinuses were detected in 32.0% of patients, with a significantly higher prevalence in males (P<0.05), but no significant association with age (P>0.05). Epithelial thickening and retention cyst were the most common abnormal findings in the paranasal sinuses. According to the Lund-Mackay classification, 93% of the study population had normal sinuses (score<4). Concha bullosa and paradoxical concha were detected in 15.3% and 3.4%, respectively, with no significant association with the presence of septal deviation or Lund-Mackay classification (P>0.05). Conclusion: Considering the relatively high prevalence of abnormal findings in the paranasal sinuses, it appears that clinical symptoms alone are not sufficient to diagnose sinusitis. A more accurate strategy would be to assess radiographic images of the paranasal sinuses and use a classification system. Sinusitis should be suspected in patients receiving a high score in this classification.