• 제목/요약/키워드: oral exposure

검색결과 615건 처리시간 0.027초

Prevalence of dental implant positioning errors: A cross-sectional study

  • Gabriel, Rizzo;Mayara Colpo, Prado;Lilian, Rigo
    • Imaging Science in Dentistry
    • /
    • 제52권4호
    • /
    • pp.343-350
    • /
    • 2022
  • Purpose: This study evaluated the prevalence of dental implant positioning errors and the most frequently affected oral regions. Materials and Methods: A sample was obtained of CBCT images of 590 dental implants from 230 individuals who underwent diagnosis at a radiology center using cone-beam computed tomography from 2017 to 2020. The following variables were considered: thread exposure, violation of the minimum distance between 2 adjacent implants and between the implant and tooth, and implant contact with anatomical structures. Descriptive data analysis and the Pearson chi-square test(P<0.05) were performed to compare findings according to mouth regions. Results: Most (74.4%) of the 590 implants were poorly positioned, with the posterior region of the maxilla being the region most frequently affected by errors. Among the variables analyzed, the most prevalent was thread exposure (54.7%), followed by implant contact with anatomical structures, violation of the recommended distance between 2 implants and violation of the recommended distance between the implant and teeth. Thread exposure was significantly associated with the anterior region of the mandible (P<0.05). The anterior region of the maxilla was associated with violation of the recommended tooth-implant distance (P<0.05) and the recommended distance between 2 adjacent implants(P<0.05). Implant contact with anatomical structures was significantly more likely to occur in the posterior region of the maxilla (P<0.05). Conclusion: Many implants were poorly positioned in the posterior region of the maxilla. Thread exposure was particularly frequent and was significantly associated with the anterior region of the mandible.

악교정 수술 후 감각소실에 관한연구 (NEUROSENSORY DEFICIT AFTER ORTHOGNATHIC SURGERY)

  • 류성호;조영철;손장호;성일용;장현호;김재승
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권6호
    • /
    • pp.482-487
    • /
    • 2004
  • Aims: This study was designed to determine the incidence of altered sensation in patients undergoing orthognathic surgery. Method: Seventy two patients who underwent orthognathic surgery between January, 1999 and December, 1999 constituted the study group. Seven patients were excluded because of lack of follow up. Sixty five patients were followed using objective and subjective neurologic testing during the period immediately following operation, 1 month, 2 months, 6 months, and 1 year postoperatively. Age ranged from 17 to 38 years, with a mean of 24.5 years. Male patients were 21, female 44. Twenty eight bilateral sagittal splitting ramus osteotomy(BSSRO) of mandible were performed, 35 BSSRO with genioplasty, 2 genioplasties. Information on the degree of intraoperative nerve encounter was obtained from the surgical reports in 47 patients and was divided into the following three categories: (1) the nerve was not encountered in 23 patients; (2) the nerve was exposed in 11 patients; (3) the nerve was exposed and repositioned from the proximal segment in 13 patients. Results: Four patients reported altered nerve sensation of lower lip and/or chin(6.2%) at final follow up. Two patients underwent BSSRO and the other two patients BSSRO with genioplasty. Three of the patients underwent nerve exposure during the operation. Conclusion: We suggest that the nerve exposure during the operation might be partly responsible for nerve dysfunction after orthognathic surgery.

Effect of Oral Administration of DiakurTM (a Glucose and Electrolytes Additive) on Growth and Some Physiological Responses in Broilers Reared in a High Temperature Environment

  • Takahashi, Kazuaki;Akiba, Yukio
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제15권9호
    • /
    • pp.1341-1347
    • /
    • 2002
  • An experiment was conducted to determine effects of oral administration of $Diakur^{TM}$ (an additive of glucose and electrolytes for young calves) on growth performance and some physiological responses in male broilers reared in a high temperature. A 2 by 3 factorial arrangement test of 2 temperatures (24 and $36^{\circ}C$) and 3 levels of oral administration of the glucose and electrolytes additive, $Diakur^{TM}$, (0, 150 and 300 mg/day/100 gBW) were applied in the experiment. Male broiler chicks (2 weeks of age) were assigned to six groups and received dietary and temperature treatments for 7 days. The additive of glucose and electrolytes was suspended with water and intubated into crop twice a day (08:00 and 17:00). Oral administration of the additive prevented decreases in food intake and growth rates in broilers due to exposure of the hot environment. Oral administration of the additive also improved a lowered electrolyte ($Na^+$ + $K^+$ - $Cl^-$) balance in plasma, low mitogenic response of blood mononuclear cell and an increase in glucose concentration due to exposure to the high environmental temperature. Oral administration of the additive increased rectal temperature regardless of environmental temperatures. On the other hand, blood pH, $pCO_2$ and $HCO_3$ - concentration, and plasma creatine kinase activity were not affected by the oral administration. The results suggested that oral administration of the glucose and electrolytes additive, $Diakur^{TM}$ during heat stress did not only prevent decrease in growth performance, but also normalized some physiological and immunological responses in male broilers.

Positioning errors and quality assessment in panoramic radiography

  • Dhillon, Manu;Raju, Srinivasa M.;Verma, Sankalp;Tomar, Divya;Mohan, Raviprakash S.;Lakhanpal, Manisha;Krishnamoorthy, Bhuvana
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.207-212
    • /
    • 2012
  • Purpose: This study was performed to determine the relative frequency of positioning errors, to identify those errors directly responsible for diagnostically inadequate images, and to assess the quality of panoramic radiographs in a sample of records collected from a dental college. Materials and Methods: This study consisted of 1,782 panoramic radiographs obtained from the Department of Oral and Maxillofacial Radiology. The positioning errors of the radiographs were assessed and categorized into nine groups: the chin tipped high, chin tipped low, a slumped position, the patient positioned forward, the patient positioned backward, failure to position the tongue against the palate, patient movement during exposure, the head tilted, and the head turned to one side. The quality of the radiographs was further judged as being 'excellent', 'diagnostically acceptable', or 'unacceptable'. Results: Out of 1,782 radiographs, 196 (11%) were error free and 1,586 (89%) were present with positioning errors. The most common error observed was the failure to position the tongue against the palate (55.7%) and the least commonly experienced error was patient movement during exposure (1.6%). Only 11% of the radiographs were excellent, 64.1% were diagnostically acceptable, and 24.9% were unacceptable. Conclusion: The positioning errors found on panoramic radiographs were relatively common in our study. The quality of panoramic radiographs could be improved by careful attention to patient positioning.

방사선조사가 백서 협점막에 미치는 영향에 관한 전자현미경적 연구 (AN ELECTRON MICROSCOPIC STUDY ON THE EFFECTS OF IRRADIATION ON THE BUCCAL MUCOSA OF RAT)

  • 최승규;이상래
    • 치과방사선
    • /
    • 제17권1호
    • /
    • pp.7-20
    • /
    • 1987
  • The author studied the acute reaction of cobalt-60 irradiation to buccal mucosa in rats and difference of the effects of single versus fractionated exposure. 195 Sprague Dowley strain rats, weighing about 120gm, were used in this experiment. 3 rats served as controls and the remaining 192 rats were divided into six groups of 32 rats each. Experimental group Ⅰ, Ⅱ, Ⅲ were received a single dose of 15Gy, 16.5Gy, 18Gy and group Ⅳ, Ⅴ, Ⅵ were received two equal sized fractionated dose of 9Gy, 9.75Gy, 10.5Gy at 4 hour intervals, respectively. The experimental groups were irradiated with cobalt-60 teletherapy unit, Picker model 4M 60 (Field size, 12x5 cm, SSD, 50㎝, Dose rate, 222cGy/min, Depth, 1㎝). The animals were sacrificed at 1, 2, 3, 6, 12 hours, 1, 3, 7 days after irradiation and the changes of the irradiated buccal mucosa were observed by electron and light microscopy. The results were as follows: 1. A single exposure was more damaging than fractionated exposure, and as the radiation dose increased, the changes of cell organelles became faster, but the healing of radiation-induced damage in fractionated exposure was faster than in single exposure. 2. The radiation-induced changes of the basal cells were the most prominent in 18Gy-single exposure group, and the least in 18Gy-fractionated exposure group. 3. Electron-microscopically, there appeared nuclear changes, swelling of mitochondria and rough endoplasmic reticulum, decrease of free ribosome, presence of vesicles, widening of intercellular space, and loss of basal lamina. The early remarkable changes were partly loss of nuclear membrane and swelling of mitochondria. 4. Light-microscopically, derangement and pyknosis of basal cells, hydropic changes of spinous cells, enlargement of granular cells, indistinctness of basement membrane, and proliferation of epithelium were observed.

  • PDF

Medication-Related Osteonecrosis of the Jaw Associated with Palatal Bone and Soft Tissue Trauma: A Case Report

  • Singh, Harpreet;Saleh, Wafaa;Cha, Seunghee;Katz, Joseph;Ruprecht, Axel
    • Journal of Oral Medicine and Pain
    • /
    • 제44권1호
    • /
    • pp.31-34
    • /
    • 2019
  • The aim of this case report is to present a case of 68-year-old male with a history of multiple myeloma and the intravenous use of Zometa (zoledronic acid) who had developed medication-related osteonecrosis of the jaw (MRONJ) following a hot pizza burn to the palate. Clinical and radiographic findings revealed grade 1 MRONJ of the right side of the hard palate. Soft tissue trauma and delayed epithelialization may be associated with some cases of MRONJ. Patients on anti-resorptive medications or anti-angiogenic drugs should be informed of the risk of bone exposure and subsequent MRONJ secondary to physical/chemical insults to the bone and soft tissue in the oral cavity.

Digora$\textregistered$에서 정량영상의 특성에 대한 평가 (The Assessment on the Characteristics of Quantitative Image in Digora$\textregistered$)

  • 김재덕
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.397-405
    • /
    • 1999
  • Purpose: To clarify the usefulness and the limitation of Digora system/sup (R)/ by evaluating the physical characteristics as the quantitative image on Image Plate(Ip). Materials and Methods: Radiograms were taken by Heliodent MD(Siemens Co.. Germany) with the image plate for adult. Cu-step wedge as reference material. and three pieces of dry mandibular bone. Image analysis was performed by single color enhancement. density measurement with histogram. The relationship between the exposure conditions and the distribution of the pixel values of the image. the variation of pixel values of each step of Cu-step wedge at two different area and Cu-equivalent value of three pieces of dry mandibular bone measure by the conversion equation. Results: There was no linear relationship between the exposure condition and the average pixel value of the image. of which the distribution was not even. The pixel value differences between the center portion and the periphery were ranged from 60 to 70 in vertical plane and from 15 to 26 in horizontal plane. Two plot profile formed at two different areas of the Cu-step wedge were different. The measured Cu-equivalent values showed the discrepancy among the times of measurement. Conclusion: As above results. Image Plate(Ip) of Digora system/sup (R)/ showed the limitation as the quantitative image. The physical property of IP was expected to need to be compensated for the quantitative evaluation of the bone or others

  • PDF

Micro-CT analysis of LPS-induced Alveolar Bone Loss in Diabetic Mice

  • Park, Hae-Ryoung;Park, Byung-Ju
    • International Journal of Oral Biology
    • /
    • 제37권3호
    • /
    • pp.85-90
    • /
    • 2012
  • Periodontal disease induces an increased incidence of tooth loss, particularly in cases with an associated loss of alveolar bone and periodontal ligaments. In this study, alveolar bone loss was detected by micro-computed tomography (CT) following exposure to E. coli lipopolysaccharide (LPS) in a streptozotocin (STZ)-induced diabetic mouse model. A 10 mg/ml dosage of E. coli LPS was applied between the first, second and third molars of the mice three times a week for 10 weeks. The loss of periodontal ligaments and alveolar processes was then evaluated by micro-CT using two and three dimensional microstructure morphometric parameters. In the diabetic mice, E. coli LPS induced the destruction of periodontal ligaments and loss of alveolar process spaces. The distances between periodontal ligaments were significantly widened in the STZ-LPS group compared with the untreated STZ group. The 10 mg/ml exposure to E. coli LPS in the STZ mice also resulted in a significant decrease in the alveolar bone volume fraction. The results of our study suggest that alveolar bone loss can be readily detected by volumetric micro-CT analysis as an increase in the distance between periodontal ligaments and in the alveolar process length.

방사선사진용 디지털 영상시스템의 정량적 평가에 관한 실험적 연구 (EXPERIMENTAL STUDY ON QUANTITATIVE EVALUATION OF FILM-BASED DIGITAL IMAGING SYSTEM)

  • 조형희;김은경
    • 치과방사선
    • /
    • 제24권1호
    • /
    • pp.137-147
    • /
    • 1994
  • A digital imaging system using Machintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quickcapture Frame Grabber Board was evaluated for quantitative analysis of standardized periapical film with aluminum step wedge. The results were as follows: 1. Correlation between Al thickness and gray level was high-positively associated(r²=0.99, p<0.001). 2. Correlation between measured weight of experimental lesion and estimated relative lesion volume by digital subtracted radiography was also high-positively associated (r²=0.98, p<0.001). 3. As exposure time was increased, mean gray level was decreased(p<0.01) and slope of regression line between Al thickness and gray level was also decreased (p<0.01). And when the exposure time was shorter than 0.2 second, the value of r² was relatively low. On the basis of the above results, it is considered that this digital imaging system using a Macintosh Ⅱ ci computer & a high resolution CCD monochrome camera will be useful in evaluating digitized image from standardized periapical film quantitatively.

  • PDF

Cytotoxicity of Impregnated Dental Gingival Retraction Cord Extracts in Immortalized Human Oral Fibroblasts and Keratinocytes in vitro

  • Myung-Jin Lee;Song-Yi Yang
    • 한국재료학회지
    • /
    • 제33권4호
    • /
    • pp.130-134
    • /
    • 2023
  • This study evaluated cell viability and cytokine release in immortalized human oral fibroblasts (hTERT-hNOFs) and keratinocytes (IHOK) exposed to a dental-impregnated gingival retraction cord. To prepare the extracts, dental gingival retraction cords impregnated with aluminum chloride hexahydrate were immersed in a cell culture medium for 24 h at 37 ℃. hTERT-hNOFs and IHOK were cultured for 24 h. The cell culture medium was removed and extracts of the dental gingival retraction cords were added. After incubation with the extract solution, cell viability was evaluated using an MTT assay. The levels of the cytokines IL-1α and IL-8 were measured in the supernatants of each cell type. The cell viability after exposure to the extract solution for 10 min exceeded 70 % in both cell types. The ET50 values for hTERT-hNOF and IHOK were 35.75 and 28.98 min, respectively. For IHOK, the IL-1α level was (5.35 ± 5.22) pg/mL at 10 min, (3.58 ± 5.38) pg/mL at 20 min, and (2.85 ± 4.28) pg/mL at 60 min of exposure (p > 0.05). The IL-8 level in IHOK was (67.16 ± 18.70) pg/mL at 10 min, (78.36 ± 7.50) pg/mL at 20 min, and (111.9 ± 26.10) pg/mL at 60 min of exposure (p > 0.05). Cytokine release was not observed from hTERT-hNOFs. Based on these results, cell viability and cytokine release were confirmed in cells exposed to the impregnated gingival retraction cord. In addition, the application of the extracts to hTERT-hNOF and IHOK during the actual contact time and determination of ET50 may be beneficial for evaluating the biocompatibility of dental-impregnated gingival retraction cords.